Abstract
To address the challenge of being unable to observe damage in the main branch area with existing reinforcement methods, a new method of relocating the slotted ring flange was proposed. Through full-scale axial reciprocating loading tests, a comparative analysis of two damage modes—the standard ring flange corner plate and the slotted ring flange relocation reinforcement—was conducted. The study also investigated the axial hysteresis performance of the slotted ring flange's X-shaped nodes.
Introduction
In steel tube trusses, particularly double-layer Vierendeel trusses, X-shaped nodes are critical points of stress. Traditional reinforcement involves welding external ring plates over these joints to prevent failure. However, these plates typically cover the "main-branch" weld area, creating a "blind spot" where cracks can form and grow undetected until catastrophic failure occurs. This research proposes a novel "upward-moved" slotted ring plate reinforcement that maintains structural integrity while allowing for direct visual monitoring of the critical weld zone.
Methods and Specimen Design
The experimental program involved full-scale testing of four specimens to evaluate the impact of the new reinforcement geometry. The specimens included two unreinforced reference joints (URX-70B and URX-100B) and two reinforced joints: CPX-70-A (standard ring plate) and CPX-70-B (novel upward-moved slotted ring plate).
The joints were subjected to axial reciprocating loading using an MTS-100 kN servo actuator to simulate seismic forces. Displacement was tracked using YWC-50 sensors, and stress distribution was monitored via strain gauges and rosettes.
Key Insights
Enhanced Inspectability
The primary breakthrough of the CPX-70-B design is the 40mm upward shift of the reinforcement plate. This gap successfully exposed the weld zone, allowing researchers to detect minor cracks at the weld root as early as the second level of displacement loading. In the standard CPX-70-A model, such damage would have remained hidden from visual inspection.
Structural Performance and Ductility
Despite the modification for visibility, the structural performance remained robust. All tested joints exhibited a plastic rotation angle exceeding 0.04 radians, surpassing the 0.03-radian threshold for strong plastic deformation capacity. Furthermore, the "concave-convex" deformation observed in the reinforcement plate of the CPX-70-B specimen serves as a secondary visual warning sign of structural distress in real-world applications.
Results
The reinforced nodes (CPX series) demonstrated significantly larger hysteresis loop areas compared to unreinforced nodes, indicating superior energy dissipation. The loops were "full," suggesting stable performance without significant pinching or sudden damage. The joints also showed excellent tensile-compression symmetry, performing consistently under both push and pull forces. While reinforcement slightly reduced the equivalent viscous damping coefficient compared to unreinforced nodes, it provided much-needed stabilization, preventing the sharp decline in energy dissipation seen in unreinforced specimens after initial loading.
Conclusion
The upward-moved slotted ring plate offers a viable solution for reinforcing X-shaped steel tube joints while ensuring "inspectability." This design balances seismic performance with the practical need for structural health monitoring. Future research should focus on parametric studies to optimize the height and thickness of the plates and explore the application of this principle to other joint geometries such as T, Y, or K-shaped nodes.