Correction to: Wearable gait analysis systems: ready to be used by medical practitioners in geriatric wards?

Malte Ollenschläger, Felix Kluge, Matthias Müller-Schulz, R. Püllen, Claudia Möller, Jochen Klucken, Bjoern M. EskofierEuropean 2022 · DOI · OpenAlex

Abstract

This document serves as a formal correction to the article "Wearable gait analysis systems: ready to be used by medical practitioners in geriatric wards?" originally published in European Geriatric Medicine. The correction rectifies a layout error where the visual overview of the sensor hardware (Figure 1) and the statistical validation of distance-tracking accuracy (Figure 2) were interchanged in the initial publication.

Introduction

Gait analysis is a vital diagnostic tool in geriatric medicine, serving as a predictor for fall risks and neurological decline. While traditional laboratory-based systems offer high precision, their cost and lack of mobility often preclude routine use in clinical wards. Wearable technology offers a promising alternative. This correction ensures the accurate presentation of the hardware setup and the validation data essential for clinicians to evaluate the system's readiness for geriatric care.

System Hardware and Interface

The wearable system is designed for seamless integration into clinical workflows. The hardware consists of two shoe-mounted Inertial Measurement Units (IMUs) attached to the instep. These sensors capture high-frequency movement data during standard clinical tests, such as the "4 x 10 m Walk Test" and the "2-Minute Walk Test" (2MWT). A tablet-based application provides a user-friendly interface for practitioners to manage tests and view results in real-time.

Figure 1: The wearable gait analysis system, including instep-mounted IMU sensors and the tablet-based practitioner interface.

Validation and Results

The reliability of the wearable system was established by comparing its automated distance measurements against manual annotations, the clinical "gold standard." The validation data for the 2MWT demonstrates a very strong positive correlation between the system's estimates and manual observations.

Figure 2: Correlation between estimated distance from the wearable system and manually annotated distance (r = 0.89, p < 0.001).

Quantitative analysis yielded a Pearson correlation coefficient ($r$) of 0.89 with high statistical significance ($p < 0.001$). The tight clustering of data points along the identity line indicates that the algorithm effectively filters the irregular gait patterns often seen in geriatric patients to produce reliable distance metrics.

Conclusion

The correction of these figures is critical for maintaining the technical integrity of the research. By accurately associating the hardware description with Figure 1 and the performance metrics with Figure 2, this document clarifies the system's design and its proven accuracy. The high correlation with manual methods suggests that this wearable solution is a viable tool for medical practitioners in geriatric wards.

Summary updated