Correction to: Noninvasive Intracranial Pressure Assessment in Acute Liver Failure

Venkatakrishna Rajajee, Craig A. Williamson, Robert J. Fontana, Anthony J. Courey, Parag G. PatilNeurocritical 2018 · DOI · OpenAlex

Introduction

This article serves as a formal correction to the previously published study, "Noninvasive Intracranial Pressure Assessment in Acute Liver Failure." The original publication contained a critical typographical error in the mathematical model used to estimate cerebral perfusion pressure (CPPe) and omitted a key methodological reference. This correction ensures the technical accuracy of the noninvasive monitoring framework proposed for patients with acute liver failure.

The Mathematical Correction

The primary focus of this rectification is the formula for calculating estimated Cerebral Perfusion Pressure (CPPe). In the original manuscript, a numerical constant was inadvertently omitted during the final production stages.

The corrected formula is as follows:

$$CPPe = MAP \times (EDV/TAPV) + 14$$

In this model, MAP typically represents Mean Arterial Pressure, EDV represents End-Diastolic Velocity, and TAPV represents Time-Averaged Peak Velocity. The addition of the constant +14 is essential for aligning noninvasive estimates with invasive "gold standard" measurements. In physiological modeling, such constants often serve as empirical offsets or represent baseline physiological pressures required for accurate regression.

Methodological Update

In addition to the formula correction, the authors have updated the methodology section to include a citation for Soldatos et al. (2008). This reference provides foundational support for the use of optic nerve sonography—specifically the measurement of optic nerve sheath diameter (ONSD)—as a diagnostic tool for identifying increased intracranial pressure in adult brain injury. This technique was a core component of the original study's noninvasive assessment protocol.

Clinical Significance

The omission of the "+14" constant in the original publication resulted in a systematic underestimation of CPPe by 14 mmHg. In the context of neurocritical care, where the target range for CPP is typically narrow (often 60–70 mmHg), an error of this magnitude is clinically significant. Accurate calculation is vital for clinicians and researchers who may be applying this noninvasive model to manage patients at risk for cerebral edema.

Conclusion

This correction restores the mathematical and methodological integrity of the original research. Researchers and clinicians utilizing these noninvasive assessment techniques must ensure they employ the updated formula to avoid significant errors in data interpretation and patient assessment.

Summary updated

BibTeX
@inproceedings{rajajee2018correction,
  author = {Venkatakrishna Rajajee and Craig A. Williamson and Robert J. Fontana and Anthony J. Courey and Parag G. Patil},
  title = {{Correction to: Noninvasive Intracranial Pressure Assessment in Acute Liver Failure}},
  booktitle = {Neurocritical},
  year = {2018},
  doi = {10.1007/s12028-018-0634-5},
}
Figure