A hospital that wants a segmentation model for a new MRI protocol usually has two ingredients: a pile of scans from an older, well-studied modality such as CT or contrast-enhanced T1 MRI, and a small number of radiologist hours. Published work picks one way to spend those hours and never compares it with the others. The cross-modality adaptation literature spends all of it drawing dense outlines on the source modality and leaves the new modality unlabeled. Scribble-based adaptation spends it on dense source outlines plus rough strokes in the new modality. Slice-selection work spends it all on the target modality alone. These are different points on a single budget line, but nobody has drawn the line.
We propose to measure that line directly. We will trace the "annotation allocation frontier": segmentation accuracy on the new (target) modality as a function of how a fixed amount of expert time is split between source and target scans, and between dense masks and cheap scribbles. Our central claim is that the best split is predictable from one cheap quantity: how badly a source-trained model does on the target modality before any adaptation. When that source-only gap is large, as in cardiac bSSFP to T2 or ceT1 to hrT2, a small number of target scribbles should beat far more source masks at equal cost. When the gap is small, as in CT across scanner vendors, dense source labels should keep winning. If the claim holds, a practitioner could decide how to spend annotation money before spending most of it.
Why this question, and what already exists
The evidence that the question matters is scattered across papers that each sit at one allocation point. CrossMoDA 2021 benchmarks the "all dense labels on the source" regime: 105 fully segmented ceT1 volumes and unlabeled hrT2. Its best team reaches a median Dice of 88.4% on vestibular schwannoma, against 92.5% for full target supervision. Scribble-based Domain Adaptation via Co-segmentation adds scribbles covering about 1% of each target T2 volume on top of 150 dense T1-c masks. It reports 83.4% Dice, above the 81.6% of a model fully supervised on its target scans. That result is the strongest hint that target scribbles are unusually valuable, but it comes from one binary tumor and one allocation. How to select slices for annotation studies budget-constrained annotation within a single modality. AMOS shows that joint CT+MRI training adds 2.14% mDice for MRI and that unseen MRI scanners cause drops of over 20%. None of these papers asks what the same hours would have bought if spent differently. That is our contribution: a controlled comparison across allocations, rather than a new network.
Two further lines of work set the difficulty of the task. On one side, Gradient-Map-Guided Adaptive Domain Generalization reports that a source-only model gets 4.9% average Dice from bSSFP to T2, so the gap can be close to total. It also reports that its gradient-map representation plus test-time adaptation recovers 85.4%, but only with dense source masks. On the other side, Learning to Segment Medical Images with Scribble-Supervision Alone shows scribbles alone lose only 2.9% Dice on ACDC and 4.5% on prostate MRI relative to full masks. Together these suggest cheap labels are nearly as informative as dense ones within a modality, while dense labels can be nearly useless across a large modality gap. The frontier we propose to measure is where those two facts meet.
Core Claim
Let $B$ be the total expert time. Let $n_s^{d}, n_s^{w}, n_t^{d}, n_t^{w}$ be the numbers of source and target scans given dense (d) or scribble (w) labels. Let $c^{d}$ and $c^{w}$ be the expert minutes per scan for each label type. We study
$$ \max_{n_s^{d},n_s^{w},n_t^{d},n_t^{w}} \; \mathrm{Dice}_t \quad \text{s.t.} \quad c^{d}(n_s^{d}+n_t^{d}) + c^{w}(n_s^{w}+n_t^{w}) \le B, $$
where $\mathrm{Dice}_t$ is accuracy on held-out, densely labeled target scans. The hypothesis is that the share of budget the optimum places on target scribbles rises monotonically with the source-only gap $g = 1 - \mathrm{Dice}_t(\text{source-only})$. We also expect it to be largely insensitive to the cost ratio $c^{d}/c^{w}$ over a plausible range. Neither the file nor any cited paper reports annotation times. We therefore will not assume a ratio. We will measure it in a small timing study and report every frontier across a sweep of ratios, so the conclusion does not depend on one guessed number.
Research Program
All allocations are trained with one fixed learner, so differences reflect the labels and not the algorithm. The learner is deliberately simple and strong. It uses a standard 3D U-Net, which AMOS found beat Swin-UNetr (89.04% vs 86.32% mDice on CT). It trains on source and target scans together with a partial cross-entropy loss that ignores unlabeled voxels, so dense masks, scribbles and unlabeled scans all fit in one objective. It adds unpaired image-to-image translation of source scans into target appearance, following the recipe of the top CrossMoDA teams. It adds style augmentation in the spirit of Style Data Augmentation. Finally it runs one round of confidence-filtered self-training on unlabeled target scans. Every allocation gets the same tuning budget and compute.
We will simulate scribbles and sparse slices from existing dense masks. This is standard practice but a known weakness, because synthetic scribbles are cleaner than human ones. To check it, a radiologist will draw real scribbles on a subset of 20 target scans; we will time that annotation and retrain the key allocations with the real strokes. The same session will time dense slice-by-slice outlining, which gives the measured cost ratio.
The analysis has three parts. First, we map the frontier on each benchmark by training a grid of allocations at three total budgets. Second, we fit the relationship between the source-only gap $g$ and the optimal target share, then test whether a rule fitted on two benchmarks predicts the best allocation on the third. Third, we check whether the gap can be estimated cheaply: from translated-source Dice on five densely labeled target scans, or without any target labels from disagreement between augmented predictions. A planning rule is only useful if it costs less than the annotation it saves.
Datasets
We choose benchmarks where both modalities carry dense masks, so any allocation can be simulated and scored. MS-CMRSeg provides bSSFP, LGE and T2 cardiac MRI for 45 patients, giving a large-gap regime. AMOS provides 500 CT and 100 MRI scans with 15 organs. CT to MRI is a large-gap multi-class setting, and CT across vendors is the small-gap control. For vestibular schwannoma we use the T1-c to T2 setup of Scribble-based Domain Adaptation via Co-segmentation, which has 50 densely labeled T2 test scans. If dense T2 training masks are not available, that benchmark contributes only its native allocation points rather than a full grid. On AMOS we will note that its MRI set is small (100 scans), which limits the budget range we can explore on the target side.
Baselines
The naive reference point is a model trained on dense source masks and applied to the target with no adaptation. On MS-CMRSeg bSSFP to T2, Gradient-Map-Guided Adaptive Domain Generalization reports 4.9% average Dice for this setting. Any allocation must beat it by a wide margin to be interesting.
The strongest existing method for the "all budget on source" regime is the translation, segmentation and self-training pipeline that won CrossMoDA 2021, with 88.4% median Dice on vestibular schwannoma and 85.7% on cochleas. On cardiac MRI the strongest reported single-source result is GMR with test-time adaptation at 85.4% average Dice on bSSFP to T2. We will reimplement the CrossMoDA-style pipeline and GMR+PITTA on our splits, using the same backbone and the same tuning budget as our learner. We will report their numbers next to the published ones so reimplementation gaps are visible. An allocation "beats" these baselines if, at equal measured expert time, it gives higher target Dice with non-overlapping bootstrap intervals over test scans, and does so for at least the middle of the cost-ratio sweep.
For the "scribbles in target" regime, the reference is the co-segmentation method of Scribble-based Domain Adaptation via Co-segmentation at 83.4% Dice on its T2 test set. We will run it where its dataset-level graph is tractable. On 15-organ AMOS it may not be tractable, and we will report that directly.
For the "all budget on target" regime, the reference is dense annotation of selected target slices following How to select slices for annotation. Two ablations isolate the key ingredient, which is using the source modality at all. The first reruns every mixed allocation with the source scans removed. The second keeps the source scans but drops translation and style augmentation. Together they show whether the source data helps through shared anatomy or only through appearance matching.
Why not just…?
Why not just spend the whole budget densely annotating target slices? This is the most serious threat. If the target cohort is large and the modality gap is severe, source data may add little once some target labels exist. The ablations that remove the source scans test this directly. If target-only matches every mixed allocation across all three benchmarks, the answer to our question is "ignore the source." That would still be a useful, clean result. It would contradict how the cross-modality adaptation field frames its problem.
Why not just use the CrossMoDA recipe with dense source masks, which already gets within about 4% of full supervision? That 4% gap was measured with 105 dense source volumes, a large expert cost that is never charged in the comparison. The co-segmentation result of 83.4% against 81.6% suggests a far smaller spend on target scribbles closes a similar gap. Our frontier puts both on the same time axis and settles which is cheaper per point of Dice.
Why not just prompt a foundation model such as SAM with boxes? Prompts are expert time too, and we will charge them to the budget. ESP-MedSAM reports interference between conflicting modalities and is validated only on 2D images. We include a slice-wise box-prompt arm on the target modality, costed by measured prompting time. It shows whether per-scan prompting beats spending the same time on training labels.
Why not just use heavy style augmentation and skip target labels? Augmentation is already inside our learner, so any benefit it brings is shared by every allocation. Style Data Augmentation itself reports failure on myocardial scar. We will report LGE scar-adjacent structures separately to see whether target labels matter most exactly where appearance, not shape, carries the signal.
Decisive Checks
The main test is whether the fitted gap-to-allocation rule predicts the best split on a benchmark it was not fitted on. We will call it a success if the predicted allocation lands within 1 Dice point of the best allocation in the grid. We call it a failure if the optimum ignores the gap, for example if the best target share is the same on CT-to-CT and bSSFP-to-T2. A second check reruns the key allocations with real human scribbles: if the ranking of allocations flips, the simulated frontier cannot be trusted. A third check reports expected calibration error for each allocation. Calibration here means whether the model's stated confidence matches how often it is actually right. Improved post-hoc probability calibration reports errors of 15–17% out of domain. If target scribbles improve Dice but leave calibration equally poor, the planning rule needs a caveat before clinical use.
References
- CrossMoDA 2021 challenge: Benchmark of Cross-Modality Domain Adaptation techniques for Vestibular Schwnannoma and Cochlea Segmentation
- Scribble-Based Domain Adaptation via Co-segmentation
- How to select slices for annotation to train best-performing deep learning segmentation models for cross-sectional medical images?
- AMOS: A Large-Scale Abdominal Multi-Organ Benchmark for Versatile Medical Image Segmentation
- Gradient-Map-Guided Adaptive Domain Generalization for Cross Modality MRI Segmentation
- Learning to Segment Medical Images with Scribble-Supervision Alone
- Style Data Augmentation for Robust Segmentation of Multi-modality Cardiac MRI
- ESP-MedSAM: Efficient Self-Prompting SAM for Universal Domain-Generalized Medical Image Segmentation
- Improved Post-hoc Probability Calibration for Out-of-Domain MRI Segmentation