Patient-specific finite element models of bone are built by tracing an anatomical structure on a CT scan, turning the traced surface into a mesh of small tetrahedra, and solving for stress under load. Surgical conclusions then rest on single numbers from that solve. One example is whether stress on a vertebral endplate under a spinal fusion cage stays below the roughly 60 MPa limit associated with cage sinking into bone. Two experts never trace a bone identically, and yet every published pipeline in this area uses one tracing as if it were the true geometry. We propose to measure how much this disagreement changes the clinical output, and to explain where the change comes from. The tool is a one-time adjoint computation: a single extra finite element solve that tells, for each point on the bone surface, how much the output would change if the surface moved outward there. Multiplying this surface map by the observed spread between annotators gives a map of mechanically consequential disagreement. It predicts the output variance without re-solving for every tracing, and it tells annotators which few square millimetres of boundary are worth arguing about.
The claim is that geometric agreement scores such as Dice overlap or Hausdorff distance say little about mechanical agreement, because both human disagreement and mechanical sensitivity are concentrated in small regions: endplate rims, articular margins, fracture edges. Their overlap, not their separate sizes, sets the uncertainty in predicted stress. If this is right, spending a fixed budget of expert adjudication time on the high-overlap regions should shrink the spread in predicted stress far more than spending it where annotators simply disagree most.
Core Claim and Mechanism
Let $Q$ be a scalar clinical output, such as a smoothed maximum of von Mises stress over the endplate contact region. Let $v_r(x)$ be the signed normal distance at surface point $x$ between annotator $r$'s surface and a reference surface. Let $s(x)$ be the shape derivative of $Q$, meaning the change in $Q$ per unit outward normal motion of the boundary at $x$, obtained from one adjoint solve. To first order,
$$ Q_r \approx Q_0 + \int_{\Gamma} s(x)\, v_r(x)\, dA, \qquad \operatorname{Var}(Q) \approx \int_{\Gamma}\!\int_{\Gamma} s(x)\, C(x,x')\, s(x')\, dA\, dA', $$
where $\Gamma$ is the reference surface, $Q_0$ the output on it, and $C$ the across-annotator covariance of $v_r$. The first-order form follows from linearizing the solution with respect to boundary position. The integrand $s(x)\,v_r(x)$ is the map we care about.
This framing departs from four lines of prior work. The first is the standard clinical pipeline. Tibial impact models (L. Liu et al.), lumbar fusion models (Guo et al.), calcaneal fixation models (Different Internal Fixation Methods for Sanders Type II and III Calcaneal Fractures) and pelvic prosthesis models (Zhou et al.) all segment once and solve once. These papers motivate the work: their conclusions sit close to thresholds whose robustness to tracing was never checked. Guo et al. report osteoporotic unilateral-screw endplate stress of 69.18 MPa in flexion against a 60 MPa limit, a margin of about 9 MPa.
The second is the Statistical Finite Element Method (Girolami et al.), which places a Bayesian prior over the solution to absorb forcing and model error using displacement sensors. It keeps the domain fixed and needs in-body sensors that clinical bone cannot have. We instead treat the domain boundary itself as the uncertain quantity.
The third is multi-rater segmentation modelling. The variational model of Liu et al. and Pionono (Schmidt et al.), which gives each annotator a learned bias and inconsistency in a latent space, supply the idea that disagreement has structure. Both, however, stop at overlap scores.
The fourth is the Diagnosis-First framework (Wu et al.), which weights annotators by what helps a downstream classifier. It is the closest conceptual relative. Our downstream task is instead a physical field, and our weighting comes from an analytic sensitivity rather than a trained network, so no labels of mechanical "correctness" are needed.
Research Program
Multi-rater bone set. Existing bone benchmarks such as VerSe, CTSpine1K and PENGWIN 2024 provide one label per structure. We will therefore collect independent tracings. Five annotators, ranging from radiology resident to musculoskeletal radiologist, will each trace L4–L5 motion segments from about 30 VerSe and CTSpine1K scans, stratified by bone density as estimated from Hounsfield units. The same annotators will trace about 15 PENGWIN pelvic fracture cases. We add two "machine observers": an nnU-Net trained on CTSpine1K, and a VerSe-style pipeline. These capture the domain-shift disagreement that CTSpine1K documents.
Finite element models. Each tracing is meshed automatically with a fixed, scripted smoothing protocol, so that differences between meshes come from the tracings and not from hand repair. Bone modulus is mapped from Hounsfield units as in L. Liu et al. We then reproduce Guo et al.'s loading on an oblique lateral fusion construct with bilateral and unilateral screws. The outputs are endplate stress, the probability of exceeding 60 MPa, and segment stiffness. For the pelvic cases, the output is fragment interface stress under 700 N walking load, matching the calcaneal study's load level.
Sensitivity maps. The adjoint shape derivative is computed once per case on the reference surface. Surface correspondence across tracings, which gives $v_r$, comes from closest-point projection along normals.
Analyses. We will test whether first-order prediction of each annotator's output matches the full re-solve, and where it breaks. Breakdown is expected at fracture lines, where annotators disagree about topology (whether a crack separates fragments). We will also test whether Dice and HD95 predict output discrepancy at all. Finally, we will test whether sensitivity-weighted adjudication beats the alternatives.
Baselines
The naive reference point is current practice: one annotator's tracing, one solve, and no uncertainty reported. We will quantify how often the threshold verdict flips if a different annotator's tracing is used. No reported result was found on Lacuna for finite element output variance under inter-observer segmentation variability in bone, so this first number is itself a contribution.
The reference standard is brute-force solving on every observed tracing. It is the ground truth for variance and for flip rates, and it is run on identical meshing and solver settings. The linearized estimate beats nothing here. Instead it must match this reference: rank correlation above 0.9 between predicted and solved per-annotator outputs on spine cases would count as success.
The strongest competitor for predicting spread is isotropic boundary perturbation. This means dilating and eroding the consensus mask by ±1 voxel, or adding random smooth normal displacements with matched average magnitude. It is the cheap sensitivity analysis a biomechanics reviewer would run, and it uses the same adjoint map. It is run with the same displacement budget, so the only difference is spatial structure. We beat it if real annotator covariance predicts solved variance with at least half the error.
The strongest competitor for guiding adjudication is uncertainty-driven review, which sends annotators to the regions of largest disagreement, as a Pionono or ensemble variance map would suggest. The strongest segmentation numbers in the file (VerSe 2020 winner at 91.72% Dice; Pionono at κ = 0.758 on Gleason 2019) are overlap scores. None reports mechanical outcomes, so the competitor's mechanical performance must be measured here.
Three regions will be adjudicated, each under the same annotator time budget of a fixed surface area re-traced by consensus:
- the top regions ranked by disagreement alone;
- the top regions ranked by sensitivity alone (an ablation isolating the rater-covariance ingredient);
- the top regions ranked by their product.
We beat the competitor if product-ranked adjudication reduces output standard deviation and flip rate significantly more than disagreement-ranked adjudication, using paired comparisons across cases.
Why not just…?
Why not just run the finite element solve on every annotator's tracing? For measuring spread with five annotators, this works, and we use it as the reference. It is a real threat to any claim that linearization is needed merely for speed. What brute force does not give is attribution: it reports that outputs differ, not which boundary region caused the difference. It therefore cannot direct adjudication or tell annotation protocols where to require care. The linearized map does both, and the adjudication experiment tests whether that attribution is actionable.
Why not just perturb the boundary uniformly by a voxel or two? If disagreement were spatially uniform, this would suffice, and our covariance term would add nothing. The experiment above decides the question directly. There is reason to expect it to fail. PENGWIN documents that experts disagree specifically at fracture lines, and localized geometric changes produce outsized mechanical effects: inferior-leaf meniscal resection cuts load bearing by 42.2% while superior-leaf resection barely matters (Xue et al.).
Why not just train a fast mesh surrogate and Monte Carlo sample annotator styles? A mesh convolutional network predicts surface fields in under 5 s with normalized error at or below 1.6% (Suk et al.). That result was on synthetic artery meshes, however, and a surrogate needs thousands of training solves per anatomy while still giving no attribution. We include it as a secondary comparison on spine cases, trained on perturbed geometries. If it matches brute force as well as linearization does, it becomes a sampling tool for Pionono-generated tracings rather than a replacement for the sensitivity map.
Why not just fuse tracings with majority vote or STAPLE and solve once? Consensus gives a single answer and hides whether that answer is robust. Smoothing across offset boundaries can also blunt the rims where stress concentrates. We will report where the consensus output falls within the annotator spread. If it sits near the median with small spread in all cases, the problem is minor and we will say so.
Proposed Experiments and Decisive Checks
The first decisive check is whether the problem exists: on spine cases, what fraction of the ±60 MPa verdicts flip across annotators, and how does this fraction depend on bone density? Near-zero flips and output spread under 5% would largely end the project. The second check is whether Dice and HD95 fail to track output discrepancy, measured by rank correlation across annotator pairs; the proposal predicts weak correlation. The third is validity of the first-order approximation, reported separately for intact vertebrae and for fracture cases, where we expect it to fail and will say so. The fourth, and the one that decides practical value, is the matched-budget adjudication comparison. Product-ranked review must beat disagreement-ranked review in both residual output standard deviation and flip rate. If sensitivity alone does as well, the lesson becomes simpler and still useful: annotate carefully where the adjoint says the mechanics are sensitive, regardless of who disagrees.
References
- Biomechanical and Injury Tolerance Analysis of Tibial Movement Under Different Postures and Impact Loads
- Biomechanical evaluation of oblique lateral interbody fusion with various fixation methods for degenerative lumbar scoliosis: a finite element analysis considering different bone densities
- Different Internal Fixation Methods for Sanders Type <scp>II</scp> and <scp>III</scp> Calcaneal Fractures: A 5‐Year Retrospective Study and Finite Element Analysis
- Improving the Stability of a Hemipelvic Prosthesis Based on Bone Mineral Density Screw Channel and Prosthesis Optimization Design
- The Statistical Finite Element Method
- Variational inference for quantifying inter-observer variability in segmentation of anatomical structures
- Probabilistic Modeling of Inter- and Intra-observer Variability in Medical Image Segmentation
- Calibrate the Inter-Observer Segmentation Uncertainty via Diagnosis-First Principle
- VerSe: A Vertebrae labelling and segmentation benchmark for multi-detector CT images
- CTSpine1K: A Large-Scale Dataset for Spinal Vertebrae Segmentation in Computed Tomography
- Benchmark of Segmentation Techniques for Pelvic Fracture in CT and X-Ray: Summary of the PENGWIN 2024 Challenge
- Biomechanical effects of the medial meniscus horizontal tear and the resection strategy on the rabbit knee joint under resting state: finite element analysis
- Mesh Convolutional Neural Networks for Wall Shear Stress Estimation in 3D Artery Models