During infection, neutrophils — the immune system's most abundant circulating white cells — eject their own DNA as web-like scaffolds called neutrophil extracellular traps (NETs), which ensnare microbes. In stroke and sepsis the same webs turn hostile: they physically trap red cells and platelets, expose tissue factor, and drive a clotting feedback loop that plugs the finest vessels Yang et al., Xin Gao et al.. A persistent puzzle in this literature is that apparently identical NET burdens devastate some microvascular regions while sparing others, and existing studies treat the microvascular bed as a black box (Sepsis review). Computer architects solved a structurally identical problem decades ago. In a supercomputer's communication fabric, the key design variable is the network diameter — the maximum number of switch-to-switch hops between any two nodes. Diameter-2 and diameter-3 topologies such as Slim Fly and Dragonfly keep traffic spread across many paths, while high-diameter meshes with few alternate routes develop persistent, self-reinforcing stalls Blach et al., Jha et al..
My claim is that capillary beds are, in graph terms, precisely the architecture that interconnect engineers designed away. Murray's-law bifurcation — each parent vessel splitting into two daughters — forces nearly every junction to degree 3, and physical space forbids the long-range shortcuts that give Slim Fly or Dragonfly their small diameter. Microvascular graphs should therefore be high-diameter, poorly expanding meshes (a graph is a good expander when every small group of nodes has many edges leaving it, i.e., no narrow bottlenecks), which is exactly the regime where a single occluded link backs up its entire upstream subtree. If true, then network topology — not NET quantity — should predict which beds collapse under immunothrombosis and whether degrading NETs with DNase actually restores perfusion. This is testable entirely in silico today, because Mathys et al. can extract vascular graphs from brain microscopy and synthesize them at scale, and Shit et al. can solve flow on such graphs.
Core Claim
Three falsifiable statements. First, microvascular graphs extracted from real and synthetic tissue sit far from the expanders that interconnect theory prizes: their diameter grows with size rather than staying at 2 or 3, and their spectral and edge expansion are small. Second, when NET deposition is modeled as progressive occlusion of vessel edges with a local positive-feedback loop (occlusion → stasis → more deposition, mirroring the tissue-factor–thrombin–platelet relay Xin Gao et al.), the fraction of tissue that loses perfusion is predicted by topological metrics — expansion and path diversity — more accurately than by NET burden alone. Third, DNase I, which cleaves the DNA backbone of NETs Shuai Liu et al., acts as stochastic edge re-insertion, and its efficacy is topology-dependent: in poorly expanding beds, randomly clearing occluded edges fails while clearing the same number of topologically critical edges restores flow.
Research Program
The first workstream is a topological census of microvascular graphs. Using the extraction pipeline of Mathys et al. — a two-stage network that predicts bifurcation nodes and then vessel adjacency, pre-trained on Murray's-law synthetic scans — I will build a corpus spanning their 100,000 homogeneous and over 1,000,000 varied synthetic scans, the 10 manually labeled two-photon microscopy scans of mouse brain, and the 50 synthetic vessel trees (about 1,700 nodes and 1,600 edges each) used by Shit et al.. On each graph I will compute diameter, degree distribution, spectral gap, and empirical edge expansion, and place the results on a spectrum between engineered diameter-2/diameter-3 fabrics Blach et al., Jha et al. and a 3D torus. One methodological honesty note: the expansion guarantees of Dinitz et al., who proved that graphs near the Moore bound for their degree and diameter are near-Ramanujan expanders, hold only for near-maximal graphs; capillary graphs are sub-maximal, irregular, and degree-3, so I will measure expansion empirically rather than apply their theorems — their framework supplies the vocabulary, not the bound, in this regime.
The second workstream is a dynamic occlusion simulator. The flow core follows Shit et al.: vessels are edges with Poiseuille conductance, junctions conserve mass, and a message-passing network — a neural model where each vessel iteratively exchanges information with its neighbors — predicts pressures. I extend it with time-stepped edge degradation. Each vessel segment $e$ carries an occlusion factor $\omega_e(t) \in [0,1]$ that multiplies its conductance,
$$g_e(t) = \frac{\pi r_e^4}{8\mu\, l_e}\,\omega_e(t),$$
where $r_e$ and $l_e$ are vessel radius and length and $\mu$ is viscosity. NET deposition events decrease $\omega_e$ stochastically, with a rate that rises for segments near already-stalled segments — encoding the procoagulant feedback loop that Xin Gao et al. demonstrated empirically (platelet microvesicles carrying HMGB1 trigger NETosis; NET-exposed tissue factor drives thrombin; thrombin recruits more NETs). When $\omega_e$ reaches zero, the edge is deleted. The simulator logs, per segment, an analog of the Percent Time Stalled metric that Jha et al. used to diagnose congestion on production supercomputers:
$$\mathrm{PTS}_e = \frac{1}{T}\int_0^T \mathbf{1}\!\left[|q_e(t)| < \epsilon\right]dt,$$
the fraction of the simulation window during which flow $q_e$ through segment $e$ is negligible. This is the no-reflow phenomenon of stroke biology, given a number.
The third workstream treats therapy as graph surgery. DNase I is modeled as raising $\omega_e$ on occluded edges — but incompletely, since Shuai Liu et al. showed DNase clears NET-DNA while leaving citrullinated histone H3 and elastase concentrations intact in tissue, so restored edges retain elevated resistance. Anti-TF antibodies attenuate the feedback rate, mirroring the combined DNase-plus-anti-TF intervention that reduced thrombin generation by approximately 69% in Xin Gao et al.. The scientific payoff is an in-silico screen over clearing rules — random edges, topologically targeted edges, global partial clearing — crossed with the topology of the underlying bed.
Baselines
The naive reference point is uniform random occlusion with no feedback, plus a burden-only predictor: a regression from the fraction of occluded edges (or simulated NET-DNA level) to perfusion outcome. This is the implicit model in most biological papers, which report NET markers and organ injury separately (Shuai Liu et al.); it is the strongest competitor for the prediction claim because it is exactly the variable clinicians can measure. It will be given the same graphs, the same event budgets, and the same Monte Carlo replays as every topological predictor. Beating it means topological metrics (expansion, diameter-to-sink, path diversity) predict perfusion collapse with materially higher AUC at matched burden — I pre-register a target of at least 0.15 AUC across replays, with burden held fixed by construction.
The strongest existing method for the simulation claim is Graflow Shit et al., the message-passing neural blood-flow solver, run in a naive dynamic mode: re-solve from scratch after each occlusion event. It reported a roughly 15% reduction in simulation time relative to a constrained L-BFGS numerical solver on the same 50 synthetic vessel trees, whose L-BFGS baseline took approximately 12 minutes per solve on a Quadro P6000 GPU. That cost is the wall: a cascade screen needs thousands of events across many replays and seeds, and 12-minute (or even 15%-discounted) per-snapshot solves do not scale; my amortized time-stepped core trains once per graph family and rolls out continuously. Fairness conditions: same vessel graphs, identical occlusion schedules and seeds, the same tuning budget (grid over feedback strength and event rates for both), and Graflow's re-solve mode gets the identical hardware. Beating it means matching its snapshot flow fields within tolerance while producing the dynamic quantities it cannot express — PTS trajectories, time-to-collapse, and recovery under edge re-insertion. A sequential 1D Poiseuille resistor solver with time-varying resistances serves as the numerical ground truth on subsampled trajectories and is also reported as a baseline in its own right.
The key-ingredient ablation is topological, not architectural: the identical simulator, identical event dynamics, run on three versions of each graph — native, pruned (delete collateral edges to raise diameter), and augmented (insert shunt edges in the spirit of the jumpers and dilation that Garnier et al. used to contract graph diameter). If collapse tracks the induced diameter and expansion rather than the event process, topology is causal and not merely correlated.
Why not just…?
Why not just run full 3D CFD with a multiphase clot model? Because the scale is wrong by orders of magnitude. Garnier et al. report that finite-volume Navier–Stokes on a single ~250,000-node aneurysm mesh takes hours on a 64-core cluster, and their graph transformer achieved a 200x speedup with over 93% wall-shear-stress accuracy on unseen geometries — and that is for one macroscopic artery with homogeneous Newtonian blood. A capillary bed screen needs thousands of stochastic replays with discrete NET meshes in individual vessels; CFD is not a contender at this scale, which is why graph abstraction exists in the first place.
Why not just use a 1D Poiseuille resistor network with time-varying resistances? This is the real threat, and I will not argue around it: such a solver can run every experiment above, and I include it as a baseline and ground-truth checker rather than pretending it away. Two honest responses. First, the scientific contribution is not the solver but the topological characterization and the PTS-style metrics — the resistor solver produces outcomes, not the explanatory variables, and my central prediction (topology beats burden) is tested on top of it either way; if the resistor baseline does everything at feasible cost, the paper still stands on the census and prediction findings. Second, cost genuinely bites: the reported L-BFGS solve time of roughly 12 minutes per 1,700-node graph Shit et al. makes the Monte Carlo therapy screen impractical, and an amortized neural core is what makes the screen tractable at all. The experiments are designed so that this question is settled empirically, not rhetorically.
Why not just do more wet-lab biology — PAD4 knockouts, intravital microscopy, DNase trials? Because the open question is global, not molecular. Wet-lab studies have already worked out the mechanism in exquisite local detail — LPS induces NETs only through platelet intermediaries Shuai Liu et al., PF4 and HMGB1 drive autophagy-dependent NETosis Jin et al., Xin Gao et al. — yet with cohorts of 45 patients and 45 controls and narrow imaging windows, they cannot observe why identical burdens infarct one region and spare another, and they cannot measure path availability across an entire bed. The model's value is that it converts this into a testable prediction: high-expansion, collateral-rich beds should resist occlusion, a claim intravital microscopy can then check region by region.
Why not just segment perfused versus non-perfused tissue with a standard CNN? Because connectivity, not voxels, is the object of study. Mathys et al. showed that a model trained only on their real scans achieved an edge-prediction F1 of just 0.067, while synthetic pre-training plus fine-tuning on 5 real scans raised it from 0.496 to 0.626 — and that voxel-level segmentation without graph structure produces fragmented vessels unsuitable for any flow simulation downstream. The graph is the point.
Proposed Experiments and Decisive Checks
Experiment one is the census: diameter, spectral gap, and empirical edge expansion across the Mathys synthetic corpora, the 10 real scans, and the 50 Graflow vessel trees, benchmarked against Slim Fly (diameter exactly 2 Blach et al.) and Dragonfly (diameter 3 Jha et al.) at matched node counts. The decisive check is whether microvascular diameter scales with size while expansion stays near mesh-level, confirming the architectural claim. Experiment two is the collapse screen on the 50 vessel trees plus a sampled synthetic set: at matched occlusion-event budgets, measure perfused tissue fraction and time-to-collapse across replays, then compare predictors. The decisive check is the AUC gap between topological and burden-only predictors, pre-registered at 0.15. Experiment three is therapy: DNase-modeled edge re-insertion under random, targeted, and global-clearing rules, crossed with expansion terciles of the underlying graphs. The decisive check is an interaction — targeted clearing should beat random clearing by a widening margin as bed expansion falls, which is the graph-theoretic restatement of why DNase helps some beds and not others Shuai Liu et al., Zhou et al.. Experiment four is the causal ablation on pruned and shunt-augmented graphs described above. Validation against biology must be directional rather than numerical: the file reports that DNase plus anti-TF reduced thrombin generation by approximately 69% in Xin Gao et al., and that NET markers remain elevated in COVID-19 survivors up to six months post-discharge Hocini; no reported result found on Lacuna for absolute perfusion-recovery percentages in the DNase animal models, so the simulator's therapeutic predictions are checked for pattern (incomplete recovery under DNase alone, amplification when combined with feedback attenuation, persistence of residual resistance), not for matched constants. If topology fails to beat burden in experiment two, the proposal's claim is wrong and I will say so; the census and simulator would still constitute the first quantitative bridge between interconnect congestion theory and immunothrombosis, but the predictive program would be dead.
References
- New Insights into Neutrophil Extracellular Traps: Mechanisms of Formation and Role in Inflammation
- Neutrophil extracellular traps mediated by platelet microvesicles promote thrombosis and brain injury in acute ischemic stroke
- Immunothrombosis in Sepsis: Cellular Crosstalk, Molecular Triggers, and Therapeutic Opportunities—A Review
- A High-Performance Design, Implementation, Deployment, and Evaluation of The Slim Fly Network
- A Study of Network Congestion in Two Supercomputing High-Speed Interconnects
- Synthetic Data for Blood Vessel Network Extraction
- Graflow: Neural Blood Flow Solver for Vascular Graph
- Neutrophil extracellular traps are indirectly triggered by lipopolysaccharide and contribute to acute lung injury
- Large Low-Diameter Graphs are Good Expanders
- Graph Deep Learning for Intracranial Aneurysm Blood Flow Simulation and Risk Assessment
- Neutrophil extracellular traps promote thrombogenicity in cerebral venous sinus thrombosis
- Neutrophil extracellular traps contribute to the pathogenesis of acid-aspiration-induced ALI/ARDS
- Neutrophil Activation and Immune Thrombosis Profiles Persist in Convalescent COVID-19