Historic districts and traditional villages are asked to modernize their energy use without changing how they look. Simulation studies show this is physically possible: internal insulation and lighting upgrades in a Shanghai historic district can cut heating demand by nearly half while leaving street facades untouched. No study in this literature asks whether a household would actually choose the compliant retrofit. In practice, residents often install cheap, rule-breaking alternatives instead: cement patches, sheet-metal sunshades, exposed plastic piping. They do this because that is what they can afford. Heritage protection then fails through thousands of small private decisions, not through one bad planning choice.
This note proposes measuring that failure directly. For each building, we compute the compliance gap: how much better off the owner is, in discounted money terms, by taking the cheapest non-compliant modernization rather than the best heritage-compliant one. The gap tells a city which buildings will defect from preservation rules unless subsidized, how large each subsidy must be, and which statutory restrictions cost the most relative to what they protect. The gap can then be set against the grid-level value of retrofits, which is known to be large but is never charged to anyone. That comparison answers whether the public, rather than the household, should pay for the difference.
Core Claim
Economic viability for heritage retrofits is judged against the wrong reference point. The natural comparison is "retrofit versus do nothing." The relevant comparison is "compliant retrofit versus the cheap non-compliant modification the resident would otherwise make." We claim that using this counterfactual changes which buildings look viable and which need support. It also changes how large the needed support is, enough that subsidy targeting based on energy savings alone, or on simple payback against doing nothing, will be measurably wrong.
Formally, for building $b$ let $\mathrm{NPV}_b(a)$ be the owner's net present value of action $a$: discounted bill savings plus valued comfort, minus upfront cost and maintenance, over a fixed horizon. Let $C_b$ be the set of actions the building's statutory tier allows, and $N_b$ the set of cheap industrial modifications residents are observed to make. The compliance gap is
$$ G_b = \max_{a \in N_b} \mathrm{NPV}_b(a) \;-\; \max_{a \in C_b} \mathrm{NPV}_b(a), $$
so a positive $G_b$ means the owner gains by breaking the rules, and $G_b$ is the minimum subsidy that removes that incentive. Separately, let $V_b$ be the avoided bulk-system cost (peak capacity, fuel) attributable to the compliant retrofit. Buildings with $V_b > G_b$ are cases where a public transfer is justified on energy-system grounds alone, before any cultural value is counted.
Where This Sits in Prior Work
The proposal is motivated by two papers that each stop where the other begins. Integrating heritage conservation into urban building energy modelling for retrofit decision-making in historic districts builds a district energy model of Shanghai's Wukang Road (1,047 buildings). It sorts buildings into four statutory tiers, from untouchable to unrestricted, and simulates tier-permitted retrofits in EnergyPlus. It reports heating reductions of up to 44.86%, cooling reductions of 31.28%, and electricity reductions of 23.66%, but it reports no costs at all. Cost-effective planning of decarbonized power-gas infrastructure to meet the challenges of heating electrification shows the opposite half. Envelope retrofits avoid about 8.5 GW of peak growth and give the lowest bulk-system cost, but the authors state that household-level envelope costs are not fully accounted for. We reuse the first paper's tier structure and simulation pipeline as our physical model. We reuse the second paper's logic of system-level value to define $V_b$. What we add is the private cost side and the non-compliant counterfactual, which neither paper has.
Two field studies supply the behavioral premise. Analysis of Traditional Village Architecture Style and Research on Protection and Utilization Strategies: A Case Study of Niba Village in Zhuoni County documents residents self-installing solar heaters, metal sunshades and plastic piping in a protected settlement, and recommends subsidies without sizing them. Research on the health performance improvement strategy of traditional dwellings in southern Henan Province under the concept of healthy building surveys 34 villages. It finds about 70% of residents using air conditioning in summer, and it proposes "low-cost" internal insulation, 4000K lighting and 0.4 m² high side windows without any cost figures. These papers establish that defection to cheap modifications is real and that compliant options exist. Our model turns their qualitative recommendations into priced actions.
Other work constrains the design rather than motivating it. Visual camouflage of equipment, as in the Palace Museum (On the Public Space Creating of the Museum in the Case of the Palace Museum), and generated facade styles (CGAN-Assisted Renovation of the Styles and Features of Street Facades—A Case Study of the Wuyi Area in Fujian, China) address appearance but carry no thermal or cost model. We treat them as actions with a cost and no energy benefit, not as solutions. The broader viability literature, for example a vision-guided sprayer reporting a 46.3% pesticide reduction with no cost accounting (Zhitao He et al.), is the pattern we are trying not to repeat.
Research Program
The work has three components.
Priced action library. For each tier we build a menu of discrete actions. The compliant menu includes:
- internal insulation, using a moisture-permeable heritage-grade material with its own price as well as a generic material for "Other" buildings;
- lighting retrofits;
- shaded high-side vents;
- camouflaged equipment housings.
The non-compliant menu mirrors what the Niba study observes: external foam or cement render, sheet-metal shading, and exposed external units and piping.
Costs come from contractor quotes and material price lists that we collect in the two study regions, since the file contains no cost data. Each action carries an upfront cost, a maintenance cost and a lifetime.
Per-building evaluation. The district model follows the Wukang Road pipeline: footprints from map services, heights from shadow inversion, and tier assignment. Wall and opening areas set both heat loss and insulation cost. We therefore estimate opening ratios from street imagery with a facade-parsing network in the style of Building Facade Parsing R-CNN, which reports 53.8% mIoU on distorted RobotCar images, rather than relying on archetype defaults.
Running EnergyPlus over every action combination for 1,047 buildings is expensive. We will therefore fit a fast surrogate (a regression model that predicts EnergyPlus outputs from building and action features) and audit it on held-out full simulations. The phytoremediation study's near-perfect fit ($R^2 = 0.9998$ in Optimizing Sustainable Phytoextraction of Lead from Contaminated Soil Using Response Surface Methodology (RSM) and Artificial Neural Network (ANN)) is a warning, not a model. We will report surrogate error on held-out buildings, not on training points.
Behavior, discounting and system value. Occupant response is modeled as a bounded range: at one end residents take all savings as lower bills, and at the other they take all savings as more comfort at the same bill. This addresses the rebound effect that the Wukang Road model omits. Household discount rates differ by setting: higher, credit-constrained rates for elderly rural households and market rates for urban owners. The system value $V_b$ is computed by pricing each building's change in peak demand and annual energy at marginal capacity and energy costs. This borrows the structure of the power-gas planning study but makes no claim to rerun its New England model.
The outputs are $G_b$ and $V_b$ for every building, tier-level shadow prices, and subsidy schedules. A tier's shadow price is the total change in gap if that tier were relaxed by one step, for example letting "Retained Historical" buildings add internal insulation.
Baselines
The naive reference point is doing nothing: current energy use, current bills, and no subsidy. Every intervention is scored against it. It is also the counterfactual that standard viability analysis implicitly uses, so it is the reference our core claim argues against.
The strongest existing physical result is the Wukang Road tiered retrofit, which reports 44.86% heating, 31.28% cooling and 23.66% electricity reductions (Integrating heritage conservation into urban building energy modelling for retrofit decision-making in historic districts). For any economic metric (payback, NPV, required subsidy) in heritage districts there is no reported result found on Lacuna. We will reproduce the tiered energy reductions within our pipeline as a fidelity check before adding economics. A reproduction far from these figures would mean our physical model, not our economics, is driving the conclusions.
The strongest competitor on the actual question is the post-hoc spreadsheet. It takes tier-permitted energy savings, multiplies them by generic unit costs and tariffs, and computes simple payback against doing nothing. It uses no heritage material premium, no non-compliant counterfactual and no behavior range. It will be run on exactly the same buildings, simulations and cost database as our method, so the only differences are the modeling choices. Our method beats it if subsidy allocations based on $G_b$ achieve meaningfully more compliant retrofits per unit of public budget, judged against the full model as reference.
The test for that is a field check. We need the full model to predict actual defection better than the spreadsheet's payback does. If so, the full model earns the right to serve as the reference.
A second policy baseline is a uniform per-square-meter subsidy of the same total budget. This is what the Niba study's "repair subsidies" would plausibly become in practice.
Three ablations isolate the key ingredients. The first removes the non-compliant counterfactual, computing the gap against doing nothing. The second removes the heritage-grade material premium. The third fixes occupancy at static assumptions. If removing the counterfactual leaves building rankings and subsidy sizes essentially unchanged, the central claim is wrong.
Why not just…?
Why not just attach unit costs to the existing tiered simulation and compute payback? This is the serious threat. For urban buildings where non-compliant alternatives are banned and enforced, it may give the same answer as our model. Our model differs only where the cheap alternative is actually available to residents. We will test this by comparing the two methods' building rankings, using rank correlation. We will also compare which buildings fall above a fixed subsidy line under each method. If the two methods agree closely in both settings, we will say so and recommend the spreadsheet. We expect disagreement mainly in villages, where enforcement is weak and the observed defection in the Niba study shows the counterfactual is live.
Why not just digitize and let physical buildings be? Virtual access protects artifacts in museums and grottoes, as the reviews of VR in heritage protection and the Dunhuang tourism analysis (On the Economic Sustainable Development Approaches and Prospects of Cultural Heritage) describe. Our setting is lived-in housing, where 70% of surveyed rural residents already run air conditioning (southern Henan study). Digitization changes neither those bills nor the incentive to modify the house cheaply. This alternative does not address the question.
Why not just let owners use cheap materials behind cosmetic covers? We do not dismiss this; we include it as an action. Cosmetic housings and generated facade designs (CGAN-Assisted Renovation) are priced in the compliant menu where regulators would accept them. If "cheap materials plus cover" turns out to close most gaps at low cost, the model will show it as the optimal compliant action. That would be a useful policy finding, not a failure of the method.
Why not just apply standard commercial retrofit economics with no tiers? We run this tier-free optimization as an upper bound on savings. The difference between it and the tier-constrained result is exactly the total cost of the heritage rules. It cannot be the recommendation, because external insulation on protected facades is not permitted under the Wukang Road tier rules. Its value lies in the comparison it provides.
Proposed Experiments and Decisive Checks
Urban district. We rebuild a Wukang-Road-scale district model and reproduce the tiered energy reductions. We then compute $G_b$, $V_b$ and tier shadow prices under a grid of discount rates and behavior assumptions.
Village setting. We use the southern Henan dwelling types and the Niba-style modification menu. Costs come from local quotes, and fuel and electricity use is anchored to the survey's reported cooling behavior.
The surrogate is accepted only if its error on held-out buildings leaves gap rankings stable compared with full EnergyPlus runs on a random audit sample. The facade-parsing ablation compares archetype-default opening ratios with image-derived ones. It reports whether cost estimates and rankings move. If they do not, the vision step is dropped.
Three checks decide the project. First, the counterfactual ablation must change subsidy targeting materially. If it does not, the core claim fails.
Second, in one surveyed village we record which households have already made non-compliant modifications, by field inspection. We then test whether $G_b$ predicts those modifications better than simple payback against doing nothing. This is the only check that tests the model against real behavior rather than against itself.
Third, we report the share of buildings with $V_b > G_b$, the cases where grid savings alone would pay for compliance. A large share would give planners a funding argument that does not depend on assigning a monetary value to heritage. A small share would show that preservation in these places must be justified on cultural grounds, and that energy savings cannot carry the cost.
References
- Integrating heritage conservation into urban building energy modelling for retrofit decision-making in historic districts
- Cost-effective Planning of Decarbonized Power-Gas Infrastructure to Meet the Challenges of Heating Electrification
- Analysis of Traditional Village Architecture Style and Research on Protection and Utilization Strategies: A Case Study of Niba Village in Zhuoni County
- Research on the health performance improvement strategy of traditional dwellings in southern Henan Province under the concept of healthy building
- On the Public Space Creating of the Museum in the Case of the Palace Museum
- CGAN-Assisted Renovation of the Styles and Features of Street Facades—A Case Study of the Wuyi Area in Fujian, China
- Design and Experiment of Variable-Spray System Based on Deep Learning
- Building Facade Parsing R-CNN
- Optimizing Sustainable Phytoextraction of Lead from Contaminated Soil Using Response Surface Methodology (RSM) and Artificial Neural Network (ANN)
- Review on Virtual Reality Technology in Cultural Heritage Protection
- On the Economic Sustainable Development Approaches and Prospects of Cultural Heritage—”Cultural Heritage Mogao Grottoes for Economic Development of Dunhuang through Cultural Tourism Cooperation” as an Example