Dynamic contrast-enhanced MRI (DCE-MRI) images the breast several times as an injected contrast agent washes into and out of tissue. Each scan is a full 3D volume, so a study is a short 4D movie. Two kinds of signal in that movie matter clinically. One is how fast each region brightens and fades. The other is how the fine-grained, "sub-visual" texture of the tissue changes as contrast fills small, leaky tumor vessels. Sub-visual texture means statistical patterns in voxel intensities that radiologists cannot see by eye. Today these signals are handled separately. Deep 3D networks stack the phases as fixed input channels, and radiomics pipelines compute handcrafted texture descriptors per phase and then fight scanner variability. Both break when hospitals use different numbers of phases at different times, which is exactly what large pooled datasets contain.
We propose a 3D encoder that reads the phases one at a time and carries a memory of the tissue from one phase to the next. That memory decays according to the real elapsed time between scans. At each step the encoder takes in how local texture has changed relative to the pre-contrast scan, rather than raw texture. The central bet is that scanner-specific texture, such as noise patterns and reconstruction artifacts, stays roughly constant within one imaging session and cancels when texture is compared against the patient's own baseline. Contrast-driven texture change, the microvascular signal, survives that comparison. If the bet holds, texture stops being the unstable feature that hurt earlier multi-feature models and becomes a feature that transfers across sites. The recurrent, time-aware design also handles any number of phases at any spacing, with memory cost that does not grow with sequence length.
Core Claim
Our claim has two parts, and each can be tested independently. The first is that self-referenced texture change, meaning local second-order intensity statistics at phase $k$ minus the same statistics at pre-contrast, generalizes across scanners better than absolute texture. The second is that a recurrent state whose update accounts for real acquisition gaps uses variable-length, irregularly timed phase sequences better than the two current alternatives. One alternative stacks phases as channels with timestamp conditioning. The other attends from each phase to the baseline pairwise.
The setting matters for honesty. Breast DCE-MRI has roughly 4–7 phases, so the familiar failure of 3D convolutions beyond about 24 frames (Making a Case for 3D Convolutions for Object Segmentation in Videos) is not the binding constraint here. The binding temporal constraint is irregular timing and a varying number of phases across sites. A fixed-input-width convolutional stack handles that badly, and a recurrence handles it naturally. We therefore do not motivate the method by sequence length.
Prior Work and Positioning
Three groups of papers bear on this proposal: work that combines recurrence with radiomics, work that models time with 3D volumes, and work that uses texture with mixed results.
MUGI-MRI (MUGI-MRI) is the closest bridge between recurrence and radiomics. It extracts handcrafted radiomics per phase from a manual region of interest, harmonizes them with ComBat, and runs an LSTM across the 7 phases. Its ablation shows that replacing the LSTM with an order-blind MLP lowers performance. That result motivates us, because it suggests phase order carries information. Its design also constrains us. MUGI-MRI has no learned volumetric features, it assumes fixed uniform phases, and it was tested on 166 lesions.
TSESNet (TSESNet) works on full 4D volumes but relates each post-contrast volume to the baseline through pairwise attention, with no state carried between phases. The acquisition-time-informed nnU-Net of Acquisition Time-Informed Breast Tumor Segmentation is the most direct competitor. It recognizes the protocol-timing problem and injects continuous timestamps through feature-wise linear modulation, a learned per-channel scale and shift driven by time. That treats time as a static conditioning signal rather than as a sequence of state transitions. We keep its insight that real timestamps matter, but use them to govern how memory evolves.
On texture, the evidence is mixed. Texture radiomics clearly helps in static settings: the osteoporosis rad-score of ST-Unet reaches AUC 0.97 versus 0.74 for density. Yet CineMyoPS reports that adding raw texture to motion and anatomy features degraded segmentation, and Peng et al. found image-only radiomics near chance (AUROC about 0.55) for chemotherapy response. We read this as a problem with absolute texture under domain shift rather than with texture itself, and the self-referencing hypothesis is a direct, falsifiable answer to that reading.
For the recurrent step itself, we borrow from video work showing that residual-stabilized hidden states carry long context cheaply (Revisiting Temporal Modeling for Video Super-resolution; Recurring the Transformer for Video Action Recognition). We also borrow the 3D depthwise-convolution state-space block of UlikeMamba as an alternative cell. Mamba4D's (Mamba4D) split between within-frame spatial modeling and across-frame temporal modeling is the template for our split between a shared 3D encoder and a temporal state. Mamba4D, however, operates on point clouds, which discard the voxel intensities we need.
Research Program
The model has three parts. A shared 3D encoder $E$ is applied to every phase volume $V_k$. A learned local texture operator $\phi$ computes, at a coarse feature resolution, local means, variances, and directional co-occurrence-like correlations of encoder features within small 3D neighborhoods. A convolutional recurrent cell then carries a state $h_k$ at each feature-map location. The texture input at phase $k$ is the self-referenced change
$$s_k = \phi(V_k) - \phi(V_0),$$
where $V_0$ is the pre-contrast volume. The state update is gated by the true time gap $\Delta t_k$ in seconds since the previous phase:
$$h_k = e^{-\Delta t_k/\tau} \odot h_{k-1} + \mathrm{Cell}\big(E(V_k), s_k, h_{k-1}, \Delta t_k\big),$$
where $\tau$ is a learned per-channel decay time and $\odot$ is elementwise product. Decay governed by the actual gap means a site that waits 90 s between phases and a site that waits 60 s produce different, physically ordered memories, rather than both being treated as "one step."
A decoder reads the final state, plus skip connections from the encoder, to produce a tumor mask. A small pooled head on the same state supports lesion-level classification. Memory is constant in the number of phases because only $h_{k-1}$ and the current volume are held. We will start with a convolutional GRU cell and swap in a 3D-depthwise state-space cell only if the GRU is the bottleneck.
The analysis program targets the self-referencing hypothesis directly. For each site we will measure how much $\phi(V_0)$ alone predicts site identity, compared with how much $s_k$ predicts it, using a linear probe. If the hypothesis is right, site information should drop sharply in $s_k$ while tumor information is retained.
Baselines
The naive reference is a vanilla nnU-Net on channel-stacked phases with no time information. On the Yunnan external cohort this setup reaches Dice 0.736, as reported by Acquisition Time-Informed Breast Tumor Segmentation.
The strongest existing method is the time-informed nnU-Net from the same paper. It reports Dice 0.774 on MAMA-MIA, Dice 0.473 on the hardest 10% of cases, and Dice 0.762 zero-shot on Yunnan. We will rerun it from released code if available, or reimplement it otherwise, on exactly our splits and preprocessing, with the same GPU budget and nnU-Net's own automatic configuration. Our model gets the same number of training epochs and no extra hyperparameter search beyond the decay initialization. Beating it means a gain in mean Dice on held-out sites, and in hardest-10% Dice, that is larger than the variation across random seeds. Gains on cases with nonstandard phase counts would be the most telling.
We will also run TSESNet's pairwise-to-baseline attention, the closest "relate each phase to $V_0$" design. Its reported BTS Dice of 78.95% is on a different dataset, so only our rerun is comparable. For the classification task we will run a radiomics pipeline in the style of MUGI-MRI, with ComBat-harmonized per-phase features and an LSTM.
Two ablations isolate the key ingredients. The first keeps recurrence but feeds absolute texture $\phi(V_k)$ instead of $s_k$. It tests whether self-referencing, not just texture, matters. The second removes recurrence entirely and gives the time-informed nnU-Net the precomputed $s_k$ maps as extra input channels. It tests whether the recurrent, gap-aware state adds anything once the texture-change signal is present. A third variant replaces the gap-dependent decay with a fixed per-step decay, to isolate the use of real timestamps.
Why not just…?
Why not just stack phases as channels and add timestamps, as the time-informed nnU-Net already does? This is the real threat, and we think it may match us on data that follow a standard protocol. Its weakness is structural: input width is fixed, so sites with fewer or more phases must be padded, truncated, or resampled. Timestamp conditioning also cannot encode the order in which signal rises and falls, which MUGI-MRI's LSTM-versus-MLP ablation suggests is informative. The phase-subset and protocol-shift tests below settle this directly. If the channel-stacked model with phase-dropout augmentation degrades no more than ours, the recurrence is not justified and we will report that.
Why not just use subtraction images or precomputed pharmacokinetic maps? Subtraction keeps one contrast snapshot and discards the wash-in and wash-out shape, as TSESNet argues. Offline kinetic parameters helped radiomics in Peng et al. but were outperformed there by a deep model. We will include a peak-minus-baseline subtraction input to the nnU-Net baseline so this alternative is measured rather than dismissed.
Why not just harmonize absolute radiomics with ComBat, as MUGI-MRI does? ComBat needs site labels and enough samples per site at training time, and it does nothing for a new, unseen site. Self-referencing needs neither, because each patient serves as their own reference. The absolute-texture ablation, with and without ComBat, will show whether harmonization alone closes the gap.
Proposed Experiments
The main benchmark is MAMA-MIA (1,473 cases from ISPY1, ISPY2, and DUKE), which pools heterogeneous protocols. We will evaluate with leave-one-source-out training: train on two sources and test on the third. For zero-shot transfer we use the Yunnan external cohort, plus the BC-MRI-SEG setting. In that setting, BC-MRI-SEG reports SegResNet falling from supervised Dice 0.75 to 0.31 zero-shot on DUKE, and SwinUNETR reaching 0.28. Those numbers define how severe the collapse we aim to reduce is, though we will compare only against our own reruns on identical splits. Metrics are Dice, hardest-10% Dice, and 95th-percentile Hausdorff distance, reported with seed variance and paired tests across cases.
The decisive experiment is a protocol-perturbation test. Models trained on full sequences are evaluated on the same test cases with phases removed, with timestamps jittered within clinically plausible ranges, and with only early or only late phases. A gap-aware recurrent model should degrade smoothly; channel-stacked models should degrade sharply or need retraining.
The second decisive check is the site-identity probe on $s_k$ versus $\phi(V_k)$. It must show reduced site information. If it does not, the texture claim fails regardless of Dice.
As a secondary task, where outcome labels distributed with the ISPY source collections can be matched to MAMA-MIA cases, we will predict response to chemotherapy from the pooled state. We compare against the MUGI-style radiomics LSTM. We found no reported result on Lacuna for pCR prediction on the ISPY cohorts, so this comparison will rest only on our own reruns.
The project fails cleanly if the time-informed nnU-Net given $s_k$ channels matches the full model under protocol perturbation. In that case the contribution reduces to the self-referenced texture input, and that is still worth reporting.
References
- Making a Case for 3D Convolutions for Object Segmentation in Videos
- MUGI-MRI: Enhancing Breast Cancer Classification through Multiplex Graph Neural Networks in DCE-MRI
- TSESNet: Temporal-Spatial Enhanced Breast Tumor Segmentation in DCE-MRI Using Feature Perception and Separability
- Acquisition Time-Informed Breast Tumor Segmentation from Dynamic Contrast-Enhanced MRI
- Hybrid transformer convolutional neural network-based radiomics models for osteoporosis screening in routine CT
- CineMyoPS: Segmenting Myocardial Pathologies From Cine Cardiac MR
- Pretreatment DCE-MRI-Based Deep Learning Outperforms Radiomics Analysis in Predicting Pathologic Complete Response to Neoadjuvant Chemotherapy in Breast Cancer
- Revisiting Temporal Modeling for Video Super-resolution
- Recurring the Transformer for Video Action Recognition
- A Comprehensive Analysis of Mamba for 3D Volumetric Medical Image Segmentation
- Mamba4D: Efficient 4D Point Cloud Video Understanding with Disentangled Spatial-Temporal State Space Models
- BC-MRI-SEG: A Breast Cancer MRI Tumor Segmentation Benchmark