NeurIPS 2026Coming to NeurIPS?Explore papers, orals & directions

Subtract the Known Switch: Detecting Partial Discharges Under Silicon-Carbide Inverter Noise

Electric motors in aircraft are now driven by silicon-carbide (SiC) inverters. These switch hundreds of volts in a few nanoseconds, and every switching edge sends a steep voltage wave down the cable. At the motor terminals the wave reflects and overshoots, sometimes to nearly twice the bus voltage. That overshoot can start partial discharges: tiny sparks in air gaps inside the winding insulation that slowly destroy it. The sensor needed to watch for these sparks, an electrical current or radio-frequency probe, is swamped by the same switching edges that cause them. At cruise-altitude pressures the sparks also turn weak and diffuse. The one sensor that sees them cleanly, an ultraviolet photon counter, needs a line of sight that a sealed stator slot never gives.

This note borrows a habit from rare-event physics, where tiny signals are pulled out of large backgrounds: model the background first, and label the signal with an independent calibration channel. The proposal rests on one asymmetry. In a dark-matter detector the background arrives at random. In an inverter it is caused by a gate command we issue ourselves, at a known time and a known operating point. We therefore propose to learn a conditional predictor of each switching transient's electrical waveform from the gate command, load current, bus voltage, temperature and pressure. Discharges are then detected in what remains after subtraction. Labels come from an optical UV counter used only during training, the way germanium experiments use calibration sources. After training, the detector runs on the electrical channel alone.

Core Claim

In a single high-frequency current transformer (HFCT) channel on a SiC-driven winding, a discriminator that works on the residual after conditional background prediction will detect low-pressure "Townsend" discharges that fixed filtering, thresholding and unconditioned waveform classifiers miss. A Townsend discharge is the slow, low-amplitude avalanche regime found near 50–150 mbar. The detection target is a partial discharge inception voltage (PDIV) curve, measured electrically, that tracks the optically measured curve across pressure. The key ingredient is conditioning on the known cause of the background. It is not a bigger classifier. If an unconditioned network does as well, the claim is false.

Why this gap is real

The physics sets up the problem. Pastura et al. build a coupled converter–cable–machine model plus a turn-level ladder model. It predicts internal turn voltages within 2–5% and shows that stress piles onto the first few entry turns. Lusuardi et al. show that PDIV is set by the peak overshoot voltage, not by rise time (7–150 ns) or switching frequency (up to 100 kHz), and that it follows a Paschen curve with a minimum near 50–70 mbar. They also report that HFCT and UHF antenna signals fade into inverter noise as discharges shift from sharp streamers to Townsend avalanches, while optical counting improves. They work around this with optics rather than solving it electrically. Rumi et al. report a PDIV drop of about 56% at 150 mbar and 140°C. They also show that thicker enamel buys only about 8.7%, so monitoring cannot be replaced by more insulation.

Two papers offer methods to adapt. Hsu et al. classify discharge pulses on 50 Hz power lines with a temporal convolutional network and global average pooling. Their background is removable with a Butterworth high-pass filter, which is not true of nanosecond switching edges. Holl et al. compress germanium detector waveforms with an autoencoder and classify them with a 141-parameter network, labelled by calibration peaks. They get 90% background rejection at 90% signal acceptance. Their calibration-driven labelling is the template we adapt.

Neither Hsu nor Holl models a background whose shape is predictable from a known cause. In the SiC setting, that predictability is the most useful fact available. The time-structure analogy with delayed-charge-recovery tails in Arnquist et al. is also informative. There, a slow tail after a fast edge identified a population that amplitude cuts missed. Townsend discharges are a slow, weak feature riding on a fast edge in the same way.

Research Program

We build three things.

The first is a labelled testbed. It is a vacuum cell holding twisted enamelled pairs, in the style of Lusuardi et al., driven by a SiC half-bridge with adjustable rise time and cable length so that reflection overshoot varies. It sweeps pressure from 1 bar to 5 mbar and temperature to 140°C. The cell carries an HFCT, a UHF antenna and a photomultiplier UV counter, all on a common digitizer.

The second is the background model. Let $x_k(t)$ be the HFCT waveform in a window after switching edge $k$, and let $c_k$ be the known conditions of that edge: edge direction, commanded dead time, load current, bus voltage, temperature, pressure and the few preceding edges. A small network $f_\theta$ predicts the expected waveform. It is trained only on edges recorded below PDIV, which the Lusuardi finding makes a clean, discharge-free background set, because inception depends on peak voltage alone. The residual is

$$r_k(t) = x_k(t) - f_\theta(c_k)(t),$$

and every downstream decision uses $r_k$ together with the model's own predicted uncertainty.

The third is the discriminator. A compact classifier in the Holl style takes the residual, its latent encoding and the predicted variance. It is trained on edges above PDIV, with each edge labelled by whether the UV counter records photons in coincidence with it. The optical channel plays the role that the thorium calibration peaks play in germanium experiments. Like those peaks, it brings a domain-shift problem: an open twisted pair is not a closed stator slot.

To measure that shift, we move to a motorette, a short test section of stator with entry-turn windings. It is driven through a cable whose overshoot is predicted by the coupled Pastura-style model. One entry-turn slot gets a fibre-coupled UV window for evaluation labels only. A calibrated charge injector adds known-magnitude synthetic discharges onto real switching waveforms, which gives ground truth on the fully sealed slots as well.

Baselines

The naive reference is what practitioners do today: a high-pass or band-pass filter followed by amplitude thresholding, with the threshold tuned on the same below-PDIV data to meet each false-alarm budget.

The strongest learned competitor is the temporal convolutional network with global average pooling from Hsu et al., retrained on our raw HFCT windows. It reports a Kaggle private-leaderboard Matthews correlation coefficient (MCC) of 0.704 on the VSB Power Line Fault Detection dataset, with validation MCC falling from 0.817 to 0.616 when pooling is removed. We first reproduce roughly that level on VSB to confirm the implementation. The second learned competitor is the Holl autoencoder plus small classifier trained on raw waveforms without conditioning. Its reported 90% rejection at 90% acceptance is on germanium DEP/FEP data, not on power electronics. We found no reported result on Lacuna for electrical partial-discharge discrimination under SiC switching at reduced pressure.

The simplest conditional competitor is template subtraction: average the below-PDIV waveforms in binned operating-point cells and subtract the matching template. The optical counter is reported as an upper-bound reference, not as a competitor.

Every learned method gets the same training edges, the same optical labels, the same hyperparameter search budget in trials and the same inference compute cap. That cap is sized for an FPGA-class edge device, in the spirit of real-time sPHENIX work.

The proposal counts as beating the baselines if, at a fixed false-alarm rate per switching edge, its detection efficiency for optically confirmed discharges exceeds the best baseline in the 50–150 mbar band. The comparison uses confidence intervals from held-out pressure and temperature runs. Its electrically measured PDIV must also stay within 10% of the optical PDIV across pressure. That 10% figure is the accuracy Lusuardi et al. report for their gas-density model.

Three ablations isolate the ingredients. The first removes the conditioning $c_k$ while keeping the architecture. The second replaces optical labels with a one-class residual anomaly score. The third replaces the network $f_\theta$ with binned templates.

Why not just…?

Why not just gate out a time window around each switching edge? Discharges start at the peak of the reflection overshoot, which Lusuardi et al. tie to inception. That peak sits inside the ringing that follows the edge, so a gate that removes the edge also removes the signal. We test this directly by plotting when optically confirmed discharges occur relative to the gate command.

Why not just subtract an averaged switching template? This is the real threat, and the proposal is built around it. If binned templates reach the same efficiency, the contribution shrinks to "template subtraction works," which is still useful and would be reported as such. We expect a learned conditional model to win on two counts. It should handle continuous load current, temperature drift and edge-history effects that fixed bins blur. It also supplies a per-edge variance, which keeps faint Townsend residuals from being buried under template mismatch. The template-versus-network ablation settles the question.

Why not just use optical UV sensing, or suppress the transients with snubbers? Optics cannot see into closed slots or shielded cables, which is where Pastura et al. locate the worst stress. Snubbers and TVS clamps, as in Zhao et al., limit spikes but give no view of insulation aging. They also leave cable-reflection overshoot in place. Slowing the gate costs switching loss, as Li notes. The motorette experiment with a sealed slot measures what electrical sensing can recover where optics cannot reach.

Why not just train a bigger unconditioned classifier like Hsu's? It may learn the operating-point dependence implicitly. If it does, the conditioning ablation will show no gap and the core claim fails. We expect it to struggle when transferred to unseen pressures and cable lengths, because the switching waveform changes with them and the network has no input telling it why.

Proposed Experiments

The decisive check is to measure a PDIV-versus-pressure curve from 1 bar to 5 mbar using HFCT alone. Each method's curve is compared against the optical curve, with particular attention to whether the Paschen minimum near 50–70 mbar is recovered and whether the curve sits about 56% lower at 150 mbar and 140°C. The prediction is that baselines drift high in the Townsend band, because they miss weak discharges and so infer late inception. The residual method should track the optical curve.

A second check is a transfer test. Train on twisted pairs at one cable length and rise time, then evaluate on held-out lengths, rise times from 7 to 150 ns and the motorette. Report efficiency at a fixed false alarm on the windowed slot, and injected-charge detection thresholds in picocoulombs on the sealed slots.

A third check tests the physics prior. We replace part of $f_\theta$ with the coupled converter–cable–machine simulation and learn only its correction. The question is whether physics-informed prediction lowers the amount of below-PDIV data needed.

Failure modes will be reported plainly. If the electrically measured PDIV cannot come within 10% of the optical curve below 150 mbar for any method, the likely conclusion is that single-channel electrical sensing is fundamentally limited in the Townsend regime.