Introduction
The aerospace industry is rapidly transitioning toward the "More Electrical Aircraft" (MEA) paradigm, replacing traditional hydraulic and pneumatic systems with high-power-density electrical actuators. These systems increasingly utilize wide bandgap (WBG) inverters, such as Silicon Carbide (SiC), to achieve efficiency and weight targets. However, SiC inverters introduce extremely fast voltage rise times (high $dv/dt$), placing unprecedented electrical stress on motor insulation. At cruising altitudes, where atmospheric pressure can drop to 20 kPa (150 mbar), these stresses often trigger Partial Discharges (PD)—localized dielectric breakdowns that can rapidly degrade organic insulation. Current standards, specifically IEC 60034-18-41, are primarily designed for ground-level industrial applications and fail to account for these low-pressure aerospace environments. This paper proposes critical modifications to the standard to ensure PD-free operation in MEA motors.
Methodology
The study employs a multi-faceted approach combining experimental characterization, mathematical modeling, and electrostatic simulations:
- Experimental Characterization: "Twisted pair" models of winding wires were tested under AC sinusoidal and surge voltages. PD Inception Voltage (PDIV) was measured across varying temperatures and pressures, comparing non-impregnated wires with those treated with various resins.
- Modeling and Simulation: A mathematical model was used to scale PDIV based on air number density (pressure and temperature). Finite Element Method (FEM) simulations evaluated the performance of different wire enamel thicknesses (Grades 2 and 3) under low-pressure conditions.
- Standard Adaptation: The authors recalculated "Enhancement Factors" (EF) within the IEC 60034-18-41 framework, using a Reference Operating Condition (ROC) of 150 mbar and 140°C derived from the IAGOS aircraft database.
Key Findings and Results
The Impact of Low Pressure and Temperature
Experimental data reveals a dramatic reduction in insulation performance at altitude. The model predicts that PDIV at the ROC (150 mbar, 140°C) is approximately 56% lower than at standard ground-level conditions. Statistical analysis of the PD parameters shows how different voltage waveforms impact the inception and extinction levels.
The Role of Impregnating Resins
A critical insight involves the behavior of impregnating resins. While resins typically improve PDIV at room temperature, their performance can degrade significantly at high temperatures. In some cases, the PDIV of an impregnated twisted pair at 140°C falls below that of a bare, non-impregnated wire. This underscores the necessity of rigorous screening before selecting resins for aerospace applications.
Insulation Thickness and Aging
Counter-intuitively, increasing insulation thickness (e.g., moving from Grade 2 to Grade 3 enamel) offers diminishing returns at low pressures. At 150 mbar, the voltage drop across the air gap dominates, and upgrading to Grade 3 wire only provides a marginal ~8.7% improvement in PDIV. Conversely, the impact of thermal aging—which typically thins the enamel—is less severe at altitude for the same reason.
Proposed Standard Modifications
To adapt IEC 60034-18-41 for MEA, the authors propose:
- New Pressure/Temperature Factor ($EF_{P,T}$): A value of 1.8 is suggested to account for the harsh ROC.
- Revised Aging Factor ($EF_{Aging}$): A reduction from the standard 1.2 to a value closer to 1.0, reflecting the reduced sensitivity to enamel thickness at low pressures.
Conclusion
Designing for the low-pressure environment of the "sky" inherently ensures safety at ground level. However, relying solely on insulation thickness is inefficient for MEA. Future designs should consider active $dv/dt$ filtering or optimized winding geometries, such as hairpin technology, to mitigate high-frequency stresses while maintaining power density.