Training one segmentation model on both CT and MRI should help the scarcer MRI data borrow strength from abundant CT. In practice the gain is small and uneven. The AMOS abdominal benchmark reports only a +2.14% mean Dice gain for MRI from joint CT+MRI training, and a drop of over 20% on MRI scanners not seen in training (AMOS). We argue that part of the problem is that joint training shares everything. Some organs look structurally alike across the two modalities and benefit from shared parameters. Others, often the small and irregular ones such as the adrenal glands, relate to their neighbours differently in CT and MRI, and forcing them to share should cause harm. We propose to measure, organ by organ and without any paired scans, how much the two modalities disagree about each organ. We would then tie a shared latent factor only for the organs that agree and give the others private, modality-specific factors.
The measurement is borrowed from collective matrix factorization, a family of methods that factor several related data tables at once while tying the factors of entities the tables have in common. The mechanism that lets this work across feature spaces that do not line up is to share the relationships between groups rather than the coordinates themselves, as in the shared central association matrix of Transfer Learning with Graph Co-Regularization. Relationships between organs can be computed inside each modality's own feature space, so they can be compared across modalities even when the CT and MRI encoders produce features of different sizes. The reason to gate the sharing comes from theory. Towards a Theoretical Understanding of Negative Transfer in Collective Matrix Factorization proves that when truly different factor subspaces are forced to be equal, two things happen. First, a bias appears that no amount of extra data can remove. Second, the estimation rate collapses from $1/|\omega|$ to $1/|\omega|^{1/d}$, where $|\omega|$ is the number of observations and $d$ is the dimension of the space of candidate subspaces.
Core Claim
In a model with a separate encoder per modality, the harm or benefit of sharing an organ's latent factor across modalities can be predicted before training finishes. The predictor is a per-organ discordance score computed from within-modality relational structure. Gating the sharing on this score should beat three alternatives on held-out-scanner MRI: full sharing, no sharing, and learned gates. The gain should be largest on small organs.
The testable consequence of the negative-transfer theory is a crossover. As labeled MRI data grows, the MRI-only model should overtake the fully shared model on high-discordance organs, because the bias from wrong sharing does not shrink with data. On low-discordance organs, sharing should stay ahead.
Research Program
The model has one encoder per modality, $E_{CT}$ and $E_{MR}$. Their stems may differ in architecture and feature width, so the input feature spaces are genuinely heterogeneous. Each encoder maps voxels into a $k$-dimensional latent space. Organ logits come from a factor matrix whose rows are organ factors:
$$W_m = W + G\,\Delta_m,$$
Here $W$ is the shared organ-factor matrix (15 organs × $k$), $\Delta_m$ is a private correction for modality $m$, and $G$ is a diagonal 0/1 gate over organs. When $G_{oo}=0$, organ $o$ is fully tied across modalities. When $G_{oo}=1$, organ $o$ is free to diverge. Following DIVA, which showed that giving nuisance variation its own latent subspace keeps it out of the class-relevant factors, we also reserve a small residual latent block per modality that the decoder may use but the organ factors may not.
The gate is set from a discordance score. We first train each encoder briefly on its own labeled data, CT-only or MRI-only. For each modality $m$ we then compute organ prototype features and a row-normalized organ-by-organ affinity matrix $R_m$ (15 × 15) in that modality's own feature space. The discordance of organ $o$ is
$$\delta_o = 1 - \mathrm{corr}\big(R_{CT}[o,:],\, R_{MR}[o,:]\big),$$
which is the disagreement between how organ $o$ relates to every other organ in CT and in MRI. This score needs no paired patients, no keypoints and no bridge domain. That is the key contrast with Latent Space Bridging, which needs synchronized paired data; with Keypoint-Guided Optimal Transport, which needs annotated anchor pairs; and with Concept Tuning and Fusing, which needs paired radiology and pathology for every patient. It plays the role that discordance analysis plays in Deep Collective Matrix Tri-Factorization, where it flags conflicting relational structure. That work applied it only to text and knowledge graphs. We use it to decide what to share. Organs above a threshold, chosen on a validation split, receive private factors, and the model is then trained jointly.
The contribution has two parts. The first is a diagnostic: does $\delta_o$ predict the per-organ gain from joint training? The second is the gated model. If the diagnostic fails, the method has no justification, and we would report that.
Baselines
The naive reference is a 3D-UNet trained on MRI alone. AMOS found this architecture stronger than Swin-UNetr on CT, with 89.04% versus 86.32% mean Dice. The file gives no absolute MRI mean Dice for it, so there is no reported result found on Lacuna for AMOS MRI-only absolute mDice, and we will produce our own number.
The strongest existing reference is joint CT+MRI training. AMOS reports that it improves MRI mean Dice by +2.14%. We run it in two forms. One is AMOS-style joint training with a single shared network. The other is our architecture with every gate closed ($G=0$), meaning separate encoders with fully tied organ factors. The second form isolates the effect of sharing from the effect of having modality-specific encoders.
We also run U-Harmony (U-Harmony), which harmonizes feature statistics and routes inputs through domain prototypes. It reported DSC gains of 1.6–3.4% and was within 1.3% of an oracle on multi-site brain MRI. There is no reported result found on Lacuna for U-Harmony on AMOS, so we reimplement it.
Two further baselines complete the set. A DIVA-style model splits the latent into domain, class and residual parts but shares everything else. A sequential baseline fine-tunes a CT-pretrained model on MRI.
The ablation that isolates our key ingredient has three arms. In the first, the gate is on for every organ, which gives no sharing. In the second, the gate is set for a random subset of organs of the same size as the discordance-selected subset. In the third, the gate is a continuous per-organ parameter learned end to end.
All methods share the same data splits, the same 3D-UNet backbone family, identical augmentation, the same GPU-hour budget, and the same number of hyperparameter trials on a validation split drawn from the training scanners. Beating the strongest competitor means two things. The mean Dice on held-out-scanner MRI must be higher than both the fully tied model and U-Harmony across three seeds. The per-organ gains must concentrate on organs the score flagged as high-discordance.
Why not just…?
Why not just train jointly and let the network sort it out? Joint training is the default, and AMOS shows it helps MRI only modestly, by +2.14%, while leaving a drop of over 20% on unseen scanners. The negative-transfer theory predicts that full sharing of a mismatched factor carries a bias that more data cannot remove. The closed-gate run tests this directly. If full sharing matches gated sharing on every organ at every MRI data size, the claim is false.
Why not just learn the gates end to end? This is the real threat. A learned per-organ gate could discover the same structure, and U-Harmony's prototype gating is close to this idea. Our bet is that with 5–20 labeled MRI volumes a learned gate overfits or opens everywhere, while a score computed before joint training is more stable. The learned-gate arm settles this. If it matches our method, the contribution shrinks to the diagnostic, which would still explain why those gates open. We would say so plainly.
Why not just fine-tune a CT model on MRI, or harmonize intensities first? Fine-tuning shares everything at initialization and then lets everything drift, so it cannot protect the organs that do agree across modalities. Harmonization such as U-Harmony aligns feature statistics but still ties every organ's factors. Both are run as baselines under matched budgets. The per-organ breakdown will show whether either approach already captures the gain on small, high-discordance organs.
Proposed Experiments
The main benchmark is AMOS: 500 CT and 100 MRI scans, 15 organs, two centers and eight scanners. We hold out every MRI scan from one scanner, or from two if scanner counts permit, as the test set. We vary the number of labeled training MRI volumes over 5, 20 and all remaining scans, and always use all CT. The metrics are mean Dice and per-organ Dice, with separate reporting for adrenal glands, esophagus, gallbladder and duodenum.
The first decisive check is the diagnostic. Across the 15 organs, we compute the rank correlation between $\delta_o$, measured before joint training, and the per-organ Dice change from full sharing relative to MRI-only. The check passes only if the correlation is clearly negative and stable across seeds and across held-out scanners.
The second decisive check is the crossover predicted by the theory. On high-discordance organs, the MRI-only model should close in on and then overtake the fully tied model as labeled MRI grows. On low-discordance organs it should not.
The third check is the head-to-head comparison of gated, random-gated, learned-gated, fully tied, U-Harmony and DIVA-style models on held-out-scanner MRI.
A secondary testbed has naturally heterogeneous input channels: brain lesion segmentation across UCSF-BMSR, BrainMetShare and BraTS-METS 2023, as used by U-Harmony. There, sites are treated as having different available sequence sets, and the "entities" are lesion and tissue classes rather than organs. We do not use this testbed to claim a win over U-Harmony's reported DSC gains, because it has only a few classes. We use it to see whether discordance still predicts transfer when the mismatch between feature spaces comes from missing MRI sequences rather than from a different imaging physics.
References
- AMOS: A Large-Scale Abdominal Multi-Organ Benchmark for Versatile Medical Image Segmentation
- Transfer Learning with Graph Co-Regularization
- Towards a Theoretical Understanding of Negative Transfer in Collective Matrix Factorization
- DIVA: Domain Invariant Variational Autoencoders
- Heterogeneous-Modal Unsupervised Domain Adaptation via Latent Space Bridging
- Keypoint-Guided Optimal Transport with Applications in Heterogeneous Domain Adaptation
- Bridging Radiology and Pathology Foundation Models via Concept-Based Multimodal Co-Adaptation
- Multi-way Clustering and Discordance Analysis through Deep Collective Matrix Tri-Factorization
- U-Harmony: Enhancing Joint Training for Segmentation Models with Universal Harmonization