Diffusion and functional MRI are acquired with echo planar imaging (EPI), a fast scan in which small magnetic-field imperfections near air–bone interfaces, such as the sinuses and skull base, shift tissue by millimetres along a single image axis, the phase-encoding direction. When several radiologists outline the same structure on these images, they disagree. Current methods for learning from several annotators treat all of that disagreement as a matter of human judgement about where a faint edge lies. We argue that in EPI, part of the disagreement is geometric. The edge is displaced, stretched, or piled up along one known axis by an amount that the physics of the field can partly predict. Readers who handle that warped or partly corrected edge differently disagree for reasons that have nothing to do with perception.
We propose a segmentation model that represents both sources explicitly. The first source is a probability distribution over the one-dimensional displacement field along the phase-encoding axis, learned from paired opposite-direction scans. The second is a compact per-rater style variable. Both act on a single 3D anatomical prediction. Because the displacement is one-dimensional and smooth, drawing many plausible 3D segmentations costs one network pass plus cheap resampling. Ensembles cost several full 3D passes, and the QUBIQ challenge identified that cost as the reason uncertainty estimates degrade in 3D. The central empirical question is falsifiable. Is inter-rater boundary variance in EPI stretched along the phase-encoding axis, and does it grow where the field is worst? If it is not, the idea is wrong.
Core Claim
We make three claims. First, on EPI-derived images, the spread of expert boundaries is anisotropic. It is larger along the phase-encoding axis than along the readout axis. This excess is concentrated where the model's predicted displacement uncertainty is high. Second, a model that samples segmentations as
$$S_{r,k} = \mathcal{W}_{d_k}\big(f_\theta(x, z_r)\big), \qquad d_k \sim \mathcal{N}\big(\mu_\phi(x), \sigma^2_\phi(x)\big)$$
reproduces the multi-rater distribution better than rater-only models, at equal compute. In this equation, $x$ is the acquired single-direction EPI volume. The function $f_\theta$ is a 3D segmentation network that works in undistorted anatomical space. The variable $z_r$ is a low-dimensional latent code for rater $r$. The field $d_k$ is a sampled displacement along the phase-encoding axis, with mean $\mu_\phi$ and variance $\sigma^2_\phi$ predicted voxel-wise. The operator $\mathcal{W}_{d}$ forward-warps a mask into acquired space, including the Jacobian intensity term that models pileup. Third, the variance can be split. Across a paired opposite-direction acquisition, the geometric part should flip sign while the rater part should not. This gives a direct experimental test of the decomposition that requires no simulated ground truth.
This is different from the closest work. EPINR fits a continuous implicit-function displacement along the phase-encoding axis for single-direction correction. The 2.5D single-direction corrector predicts a displacement map from three b0 slices plus T1w guidance. Both return a single deterministic field and are scored on whole-image similarity, and neither segments anything. Pionono and OMBA-UNet model rater styles but assume geometrically faithful 2D images. From Registration Uncertainty to Segmentation Uncertainty turns registration uncertainty into label uncertainty, but it does so on cardiac cine MRI, which has no field distortion, and against a single reference label. We join the geometric uncertainty to the multi-rater distribution, and we test the join with an opposite-direction experiment that none of these papers could run.
Research Program
The displacement branch is trained on the Human Connectome Project (HCP) 1200 data, which contains opposite phase-encoding pairs. A TOPUP-style field estimated from both directions serves as the target. Given only one direction and the T1w scan, the network predicts a mean and a variance for the displacement. It follows the input design of the 2.5D corrector but widens the through-slice receptive field with a low-resolution 3D branch. FD-Net names the lack of through-slice modelling as a limitation of slice-wise correction, and the 3D branch addresses that. The variance is fit with the β-weighted Gaussian likelihood used by From Registration Uncertainty to Segmentation Uncertainty. That paper supplies the method. It also motivates the design, because it showed that image-similarity measures barely predict boundary error, so we do not score the displacement branch on image similarity. We add the mass-preserving Jacobian and bending-energy regularisers from EPINR, since that work shows that similarity alone produces unphysical folds.
The segmentation branch is a 3D U-Net conditioned on the rater code. We use a Pionono-style Gaussian latent per rater, so parameter count and inference cost stay fixed as the number of raters grows. OMBA-UNet's multi-decoder design grows with rater count, and the file reports its inference at 0.34 s against 0.02 s for a plain U-Net. Rater masks are drawn in acquired space, as clinicians draw them on single-direction scans. The loss therefore compares warped samples against each rater's mask. To keep the rater bias and the geometric shift from absorbing each other, the displacement branch is pretrained and then frozen. The opposite-direction subset provides the identifiability check described above.
New data are required. We found no multi-rater annotations on EPI in the file, so there is no reported result found on Lacuna for multi-rater segmentation on EPI data. We will annotate about 40 HCP subjects with 4–5 raters. The main target set consists of low-contrast structures next to susceptibility hot spots, namely the temporal pole, orbitofrontal cortex, and brainstem boundaries on b0 and mean-diffusion images. The ventricles, which have high contrast and lie far from air interfaces, serve as a control where the geometric term should matter little. For 15 subjects, the same raters also annotate the opposite-direction image. A second, controlled benchmark takes T1w-derived labels and applies measured HCP fields, so the true displacement is known. We will validate the rater branch alone on the 3D QUBIQ tasks (prostate, brain, kidney, pancreas). These tasks have no EPI distortion, so there the displacement term should be switched off and the model must stay competitive.
Baselines
The naive reference is a single 3D nnU-Net-style network trained on the majority-vote mask of the uncorrected single-direction image. Its output uncertainty is the softmax. It shows what a standard pipeline gets and is expected to be poorly calibrated to rater spread. A stronger decoupled pipeline first corrects distortion with the 2.5D single-direction network and then trains the same 3D network. In the single-direction setting, that corrector reports a 53% reduction in displacement-map RMSE relative to Synb0 on NIMH-HV. A TOPUP-corrected variant, using both directions, serves as an oracle-correction upper reference.
The strongest competitor for predicting the rater distribution is a deep ensemble of 3D networks, each trained on individual rater masks. QUBIQ found that ensembles of deterministic models often beat variational models, and its top teams reached average Dice of 0.80–0.85. We will give the ensemble the same total GPU-hours for training and match inference compute. We will also report the ensemble at its natural size of five members, together with memory use. The rater-modelling baselines are a 3D Pionono-style model, which is our model without the displacement term, and OMBA-UNet adapted to 3D where memory allows. Each gets the same hyperparameter search budget of 20 trials, on the same corrected or uncorrected inputs. For reference, Pionono reports κ = 0.758 on Gleason 2019, but that is histopathology and is not directly comparable.
Two ablations isolate the key ingredient. The first sets σ to zero, which leaves a deterministic correction plus rater codes. The second replaces the learned, spatially varying σ with random smooth phase-encoding warps whose average magnitude matches the learned σ. That turns the method into physics-agnostic test-time augmentation. To count as a win, the model must beat the matched ensemble on Generalised Energy Distance and on staged Q-Dice on the EPI annotation set, with a confidence interval over subjects that excludes zero. It must do so at roughly one network pass, and it must beat the random-warp ablation specifically in the high-field regions.
Why not just…?
Why not just correct distortion first and then model raters? This is a real threat. If single-direction correction leaves little geometric error, the displacement term adds nothing, and the σ=0 ablation will tie our model. Two pieces of evidence argue against dismissing geometry. EPINR reports that similarity-driven correction does not guarantee correct local deformation. The file also notes a remaining gap between single-direction and two-direction correction. The decisive evidence will be the comparison with the TOPUP-corrected oracle. If our method's advantage vanishes once correction uses both directions, then the gain comes from residual correction error. That is still useful, because most clinical data are single-direction, but the claim would narrow to that setting and we would report it that way.
Why not just use a deep ensemble? QUBIQ shows that ensembles are hard to beat on quality. Its argument against them is computational, since 3D ensembles strain memory. We therefore compare at matched compute and also at full ensemble size. If a five-member ensemble matches us on Generalised Energy Distance, our contribution reduces to cost, and we would state that. We also expect ensembles to spread boundaries isotropically. The directional-variance analysis tests whether that makes them miss the phase-encoding-axis structure of real disagreement.
Why not just add random phase-encoding warps at test time? This is the simplest version of the idea, and the random-warp ablation tests it directly. The physics predicts displacement uncertainty that is concentrated at air–tissue interfaces rather than uniform. If matched random warps perform as well near the skull base as learned σ does, then the learned field model is unnecessary and we would say so.
Proposed Experiments
The first experiment decides whether the premise holds. On the new annotations, we decompose the inter-rater boundary spread into its phase-encoding and readout components by measuring surface-distance variance along each axis. We then regress the phase-encoding excess on the TOPUP field gradient. We expect a clear excess near the sinuses and petrous bone, and none at the ventricle control. If there is no anisotropy, the geometric hypothesis fails before any modelling.
The second is the opposite-direction test. On the 15 subjects with both directions, the geometric component predicted by the model should reverse sign between the two images, while each rater's systematic bias should not. We measure agreement with a signed-displacement correlation between the prediction and the observed shift of the rater contours.
The third tests calibration. On the simulated benchmark, where the true displacement is known, we check whether the predicted σ covers the true residual error at nominal rates. On real data, we correlate the predicted uncertainty with rater disagreement. The registration-uncertainty paper's r = 0.583 against single-label error is a loose reference point.
The fourth is the main comparison. All baselines are scored on the EPI multi-rater set using Generalised Energy Distance, staged Q-Dice, and per-rater Dice. We also report inference time and peak memory against the ensemble, and include the QUBIQ 3D check to confirm that the rater branch does not lose ground where no distortion exists.
References
- EPI Distortion Correction without Opposite Phase Encodings with Unsupervised INR-Based Deformable Registration
- Susceptibility Distortion Correction of Diffusion MRI with a single Phase-Encoding Direction
- Probabilistic Modeling of Inter- and Intra-observer Variability in Medical Image Segmentation
- Inter-Rater Uncertainty Quantification in Medical Image Segmentation via Rater-Specific Bayesian Neural Networks
- From Registration Uncertainty to Segmentation Uncertainty
- FD‐Net: An unsupervised deep forward‐distortion model for susceptibility artifact correction in EPI
- QUBIQ: Uncertainty Quantification for Biomedical Image Segmentation Challenge