Low-dose CT protocols that record only a few dozen projection angles leave much of each image undetermined by the measurements. A reconstruction algorithm fills the gap: classical solvers blur it, learned networks and diffusion models (generators that learn to turn random noise into realistic images step by step) paint in plausible texture. Prognostic radiomics, meanwhile, builds survival models by having a sparsity-inducing regression (LASSO Cox) pick a handful of texture features out of thousands. Put the two together and there is a concrete failure: the regression can pick exactly the textures the reconstructor invented, because invented texture is cleaner, more consistent, and more correlated with cohort-level structure than real tissue texture. The resulting signature looks good internally and collapses at another hospital that uses a different reconstructor or view count.
We propose to measure, for every candidate feature and every patient, how much of that feature the measurements actually pin down. We do this by reconstructing the same sparse sinogram many ways, all consistent with the data: posterior samples from a diffusion prior, null-space-constrained network outputs, and regularized iterative solutions. The ratio of within-patient spread (across reconstructions of identical data) to between-patient spread becomes a per-feature penalty weight in the LASSO Cox objective. Features the data cannot determine are shrunk hard, and features the data fix are left nearly free. Expensive posterior sampling is needed only once, at feature-selection time. At deployment a single fast feed-forward reconstruction is used, so the pipeline still runs in real time. We test whether this keeps survival discrimination and selected-feature identity stable across view counts, reconstructors, and an external institution.
Core Claim
Reproducibility filtering in radiomics asks whether a feature survives a change of scanner or a test-retest repeat. Under sparse-view reconstruction that is the wrong question. The relevant quantity is how much a feature varies among images that are equally consistent with one patient's measurements. That variance can be estimated per patient from the measurements alone, without repeat scans. Our claim is that using it as a soft, adaptive LASSO penalty yields Cox signatures whose external C-index degrades less as views drop from 360 to roughly 20. It should also yield signatures whose selected features overlap more across reconstructors than either plain LASSO or a hard ICC pre-filter. Concretely, with standardized feature $j$, let $V_j$ be its average within-patient variance across data-consistent reconstructions and $B_j$ its between-patient variance on the deployed reconstructor. We minimize
$$-\ell(\beta) + \lambda \sum_{j=1}^{p} \left(1 + \gamma \frac{V_j}{B_j}\right) |\beta_j|,$$
where $\ell$ is the Cox log-partial likelihood, $\beta_j$ the coefficient of feature $j$, $\lambda$ the overall penalty strength, and $\gamma \ge 0$ how strongly measurement-undetermined features are discouraged. Setting $\gamma = 0$ recovers ordinary LASSO Cox, which gives the cleanest ablation of the key ingredient.
Where This Sits
Three lines of work motivate the gap. When are Diffusion Priors Helpful in Sparse Reconstruction? A Study with Sparse-View CT sweeps 4 to 360 views on 935 thoracic scans. It finds diffusion priors dominate below about 25 views, plateau at 10–15, and lose to TV and Tikhonov above 25–60. It also documents "convincing but wrong" structures. Its only downstream task is fat thresholding at a single center, so it cannot say what hallucinated texture does to a learned survival signature. DM4CT: Benchmarking Diffusion Models for Computed Tomography Reconstruction benchmarks ten diffusion methods against FBP, SIRT, ADMM-TV, DIP, an implicit neural representation and SwinIR at 20 and 40 views. It finds supervised SwinIR wins on PSNR and SSIM when paired data exist, and it degrades under realistic Poisson noise. Its evaluation is pixel fidelity only. Assessing radiomics feature stability with simulated CT acquisitions is the closest methodological ancestor. It simulates sinograms with the ASTRA toolbox, varies dose, projection count and FBP versus SIRT, and measures PyRadiomics feature stability on a phantom. It notes that some unstable features remain discriminative. We borrow its simulation approach. We differ in measuring variance among data-consistent reconstructions of the same patient rather than across protocols, in working on patient cohorts with survival endpoints, and in feeding the variance into selection rather than reporting it.
Two papers constrain the design. Reproducible Radiomics Features from Multi-MRI-Scanner Test-Retest-Study shows a hard ICC ≥ 0.8 filter raised external correlation for support vector regression from 0.18 to 0.43. The same filter lowered it for random forests from 0.44 to 0.33, because "unreproducible" features carried signal. This is why we use a continuous penalty instead of a threshold, and why a hard-filter arm is mandatory. Minimising multi-centre radiomics variability through image normalisation shows ComBat removes center information but costs discrimination, while ROI-level histogram matching reached balanced accuracy 0.78–0.79. That warns against post-hoc feature harmonization as the fix and supplies a normalization baseline.
Two papers supply methods. Null Space Matters: Range-Null Decomposition for Consistent Multi-Contrast MRI Reconstruction restricts network updates to the unmeasured null space so outputs agree exactly with measurements; it reports 43.323 dB PSNR on IXI at 4x. We transpose the range-null idea to the CT projector. Our deployed fast reconstructor is a null-space-constrained feed-forward network, and the range-null split also defines what "data-consistent" means when we draw alternative reconstructions. Cross-dataset adaptation of voxel-level deep radiomics for predicting survival in inoperable locally advanced NSCLC supplies the clinical setting and the full-dose reference: RTOG 0617 for training and an external Tianjin cohort of 150 immunotherapy patients for testing. A Deep Learning-Based Radiomics Model for Prediction of Survival in Glioblastoma Multiforme supplies the multi-stage screening-plus-LASSO-Cox recipe we use as the standard pipeline; it reports a 6-feature signature with external C-index 0.710. Neither survival paper touches reduced-view acquisition.
Research Program
The first step is to build the measurement setting. Raw projections are not available for the survival cohorts, so we forward-project the clinical CT volumes with the ASTRA toolbox at fan-beam geometries of 360, 120, 60, 40, 20 and 10 views, adding Poisson counting noise at matched dose. This follows the Assessing radiomics feature stability with simulated CT acquisitions protocol, which was checked against 13 clinical scanners. Simulating from reconstructed images is an "inverse crime," meaning it can make reconstruction look easier than it is on real raw data. For that reason the diffusion and learned reconstructors are trained on a different source, the 2016 Low Dose CT Grand Challenge data used in DM4CT: Benchmarking Diffusion Models for Computed Tomography Reconstruction, and never on the survival cohorts.
The second step is the reconstructor suite. It contains FBP, TV-regularized iterative reconstruction, a supervised SwinIR-style network, a null-space-constrained unrolled network that serves as the real-time deployed model, and a measurement-guided diffusion sampler. The diffusion sampler is run with 16 independent seeds per scan, and those samples, together with the other data-consistent solutions, are what estimate $V_j$. Every reconstruction is projected back onto the measurements before features are extracted, so the spread we measure reflects only null-space ambiguity and not data misfit.
The third step is extraction and selection. Gross tumor volumes delineated on full-dose images are propagated unchanged, so segmentation is not a confound. We extract PyRadiomics handcrafted features plus pretrained deep features, compute $V_j/B_j$ on the training cohort only, and fit the weighted LASSO Cox objective. $\lambda$ is chosen by nested cross-validation, and $\gamma$ is chosen from a small grid on the internal test split. The same univariate pre-screening is applied to every arm.
The fourth step is analysis beyond the C-index. We record which features are selected at each view count and with each reconstructor, and compute their Jaccard overlap with the full-dose signature. We also run an injected-hallucination test. We plant synthetic textured nodules into some reconstructions in a way correlated with outcome in the training cohort only, then check whether each method selects features that respond to the planted texture. This is the direct test of the "confabulated signature" failure.
Baselines
The naive reference is a LASSO Cox signature trained and tested on full-dose, 360-view FBP images. It is the ceiling we hope to approach, not beat. Alongside it, the do-nothing arm uses standard two-stage LASSO Cox ($\gamma = 0$) applied directly to features from whichever reduced-view reconstructor is deployed. Its gap below the ceiling is the damage we aim to repair.
The strongest existing survival method in this setting is the voxel-level deep radiomics model of Cross-dataset adaptation of voxel-level deep radiomics for predicting survival in inoperable locally advanced NSCLC. It reports C-index 0.73 (95% CI 0.63–0.82) and 1-year time-dependent AUC 0.73 on the external Tianjin test set, using full-dose CT. We will retrain it with the same split, the same preprocessing and the same hyperparameter budget, separately on each reduced-view reconstruction. A sparse, interpretable signature that matches its external C-index at 20–40 views and degrades less as views fall would count as beating it on the question we care about. We do not expect to exceed 0.73 at full dose. For the reconstruction stage itself, I found no reported scalar PSNR or SSIM result on Lacuna for the 2016 Low Dose CT Grand Challenge at 20 or 40 views. We therefore report our own numbers for all reconstructors under one shared protocol.
The most dangerous competitor is a hard reproducibility pre-filter computed on the same simulations. It keeps only features whose ICC between each reduced-view reconstruction and full-dose exceeds 0.8, then runs ordinary LASSO Cox, mirroring Reproducible Radiomics Features from Multi-MRI-Scanner Test-Retest-Study. Two further baselines complete the set: ComBat applied with reconstructor-and-view-count as the batch variable, and ROI-level piecewise linear histogram matching from Minimising multi-centre radiomics variability through image normalisation. All arms share the training cohort, the feature pool, nested cross-validation and the number of tuned hyperparameters.
Two ablations isolate the key ingredient. The first replaces $V_j$, the within-patient spread under fixed measurements, with protocol variance, the spread between reduced-view and full-dose images of the same patient. This tests whether measurement conditioning matters or whether any instability score would do. The second drops the diffusion samples from the ensemble, which tests whether generative uncertainty adds information beyond deterministic solvers.
Why not just…?
Why not just pre-filter features by ICC against full-dose reconstructions? This is the real threat. Our protocol-variance ablation is almost exactly this filter in soft form. The argument for our version is twofold. First, a hard filter discards discriminative but partially unstable features, the failure documented for random forests in Reproducible Radiomics Features from Multi-MRI-Scanner Test-Retest-Study. Second, ICC against full-dose needs paired full-dose scans, which a reduced-dose deployment will not have at a new site, whereas $V_j$ comes from the sparse measurements alone. If the hard ICC filter matches us on external C-index and feature overlap, the honest conclusion is that measurement conditioning adds nothing, and we will report that.
Why not just use the best reconstructor and ordinary LASSO? Above about 40 views this may well suffice. When are Diffusion Priors Helpful in Sparse Reconstruction? shows classical priors recover well past 25–60 views, and fat quantification stayed competitive to about 40. We therefore expect our gain to be concentrated at 10–40 views and near zero at 120 and above. The view-count sweep is designed to show where, if anywhere, the do-nothing arm suffices. A flat gap across all view counts would actually suggest our weighting is just generic regularization.
Why not predict survival directly from sinograms? That would skip the ill-posed step, but it gives up tumor delineation, interpretable features, and auditing by radiologists. Sinograms mix tumor and background along every ray, so localized heterogeneity features cannot be computed from them. We include a sinogram-input survival network trained under the same budget as a reference. If it beats every image-based arm externally, that is an important negative result for image-based radiomics at low view counts.
Why not harmonize with ComBat afterwards? Minimising multi-centre radiomics variability through image normalisation found ComBat strips discriminative signal. In our setting, hallucinated texture is also patient-specific rather than a batch offset, so location-scale correction cannot remove it. The injected-hallucination test checks this directly.
Decisive Experiments
The primary result is external C-index on the Tianjin cohort, with time-dependent 1- and 2-year AUC, plotted against view count for every arm. Patient-level bootstrap confidence intervals are needed, because 150 patients gives wide intervals, as the reported 0.63–0.82 shows. The secondary result is Jaccard overlap of selected features with the full-dose signature, and across the five reconstructors at fixed view count.
The proposal is supported under three conditions. At 20–40 views, the weighted method must beat plain LASSO Cox and the hard ICC filter on external C-index by more than bootstrap noise. Its selected features must be markedly more stable across reconstructors. And it must reject the planted hallucination features that plain LASSO picks up. The proposal fails if the protocol-variance ablation performs equally well, or if the gain disappears once diffusion reconstructions are excluded; the latter would mean we only fixed a diffusion-specific problem that simply not using diffusion avoids.
We also report wall-clock reconstruction time for the deployed null-space network, so the real-time claim is checked rather than assumed. Finally, a held-out reconstructor test probes generalization to unseen reconstruction pipelines: we select features using four reconstructors and evaluate on the fifth.
References
- When are Diffusion Priors Helpful in Sparse Reconstruction? A Study with Sparse-View CT
- DM4CT: Benchmarking Diffusion Models for Computed Tomography Reconstruction
- Assessing radiomics feature stability with simulated CT acquisitions
- <scp>Reproducible Radiomics Features from Multi‐MRI‐Scanner Test–Retest‐Study: Influence on Performance and Generalizability of Models</scp>
- Minimising multi-centre radiomics variability through image normalisation: a pilot study
- Null Space Matters: Range-Null Decomposition for Consistent Multi-Contrast MRI Reconstruction
- Cross-dataset adaptation of voxel-level deep radiomics for predicting survival in inoperable locally advanced NSCLC treated with immunotherapy
- A Deep Learning-Based Radiomics Model for Prediction of Survival in Glioblastoma Multiforme