After a catheter procedure through the wrist, a clinician presses down on the puncture site for hours to stop bleeding. If blood stops moving in the forearm radial artery during that time, it can clot and close the artery permanently. Puncturing further down the hand, in the "anatomical snuffbox" (distal transradial access), lowers this risk. The accepted explanation is anatomical: below the snuffbox, blood can still reach the forearm trunk backwards through the arches of arteries in the palm, even while the puncture is fully compressed. Yet no one measures that backflow at the bedside. Compression time follows fixed clocks, such as 2–3 hours after distal access and 4–6 hours after conventional access. Whether the forearm trunk is actually flowing depends on each patient's palmar arch anatomy, on spasm, and on how hard the band presses. None of these is observed.
We propose to estimate the unobserved flow in the forearm radial trunk, over time, from signals that are cheap to record during compression: fingertip pulse waveforms and the pressure of the compression band. The estimator is a spatio-temporal graph model of the arm's arteries. The band pressure changes the stiffness of one specific vessel segment, and that change immediately reroutes pulsatile flow around the closed palmar loop. The model is trained on physics simulations over sampled anatomies and constrained by conservation laws. The first question is whether such an estimate is possible at all. The second is whether a learned estimator gives it quickly and accurately enough to act on.
Core Claim
Our central claim has two parts, and only the first is guaranteed to be publishable. First, we can state exactly which combinations of bedside signals make forearm-trunk flow stasis identifiable under distal versus conventional compression. Identifiable here means recoverable from the signals despite unknown anatomy. We will test this with full statistical inference on a classical one-dimensional pulse-wave simulator of the arm. Second, where the signals do carry the information, a single model can deliver a calibrated, time-resolved estimate of trunk flow in well under a second per update. That model must treat compression as a time-varying change to the vessel graph inside each space-time update, not as an extra input feature. Classical calibration would need minutes per patient-state.
The contribution is not "a graph neural network for blood flow." Prior neural flow solvers already exist. What they lack is time, compression, and closed collateral loops. The contribution is an inverse problem: recovering a hidden, clinically decisive flow from peripheral signals. That problem is worth posing even if the learned part turns out to be dispensable.
Why This Gap Is Real
The clinical literature motivates the question. It establishes that collateral protection matters, but it never measures collateral flow. The CONDITION trial (Comparison of long-term radial artery occlusion via distal vs. conventional transradial access (CONDITION)) randomized 801 patients. Three-month occlusion was 0.8% after distal access versus 3.3% after conventional access. Between 50% and 68% of early occlusions reopened on their own. RAPID III (Distal radial access to prevent radial artery occlusion for STEMI patients (RAPID III)) found 24-hour occlusion of 1.9% versus 8.5% in heart-attack patients, with hemostasis time of 209 ± 71 versus 372 ± 70 minutes. Early prevention of radial artery occlusion via distal transradial access for primary percutaneous coronary intervention reported 2.0% versus 9.0%. All three explain the benefit through palmar-arch backflow, and all three use fixed compression times.
The optical coherence tomography (catheter-based microscopic imaging of the vessel wall) study of Assessment of acute radial artery injury after distal transradial access adds the complication that matters most here. Spasm appeared in 17.5% of patients and thrombus in 17.5%, and proximal unsheathed segments spasmed more (13.0% vs 4.5%). Spasm narrows exactly the vessels whose flow we want to estimate. It must therefore be a latent variable the model accounts for, not ignored noise.
The modeling literature supplies methods but constrains how they can be used. Graflow solves steady flow on synthetic vessel trees, using a physics loss that enforces mass conservation at junctions. It assumes rigid walls, no pulsation, and open trees with no loops. We reuse its junction-conservation loss and drop all three assumptions. SE(3)-equivariant hemodynamics estimation on arterial surface meshes estimates wall shear stress on 3D meshes over 100× faster than fluid dynamics simulation. It works only on static snapshots of single bifurcations. We deliberately stay in one dimension, because the question is flow routing around a loop, not local shear detail. Physics-informed MeshGraphNets trains message-passing networks with discretized time-stepping residuals as the loss. They generalize to unseen meshes, but only for heat equations. We borrow its time-stepping residual training and time bundling.
On the spatio-temporal side, two traffic-forecasting papers argue for doing spatial and temporal mixing inside one computational unit. STUM uses a low-rank unitized cell and reports a 19.17% accuracy gain over an STGCN backbone. DSSA-TCN combines causal temporal convolutions with directional graph diffusion in every layer. Both assume a fixed graph. Our setting is one where the graph's edge properties change on a clinically controlled schedule, which is exactly where their "instantaneous coupling" argument should matter. It is also where it can be tested cleanly, because the perturbation is known. Bayesian Bi-clustering of Neural Spiking Activity shows that inferring structure first and dynamics second compounds errors. That result motivates inferring anatomy and flow jointly rather than classifying the arch type first. Finally, collateral grading in stroke (A Deep Learning Approach to Predicting Collateral Flow in Stroke Patients) reached 72% three-class accuracy from static image features, with no vessel graph or physics. It illustrates the ceiling we expect for purely static feature approaches.
Research Program
The graph and the simulator. We will build the arm's arterial tree as a one-dimensional graph of roughly 40–60 segments: brachial, radial, ulnar, interosseous, superficial and deep palmar arches, and the thumb and index digital arteries. It is small enough that a classical solver is cheap, which is why the classical solver is a baseline and not a straw man. Each segment $e$ carries cross-sectional area $A_e(x,t)$ and flow $Q_e(x,t)$, governed by the standard one-dimensional pulse-wave equations:
$$ \frac{\partial A}{\partial t}+\frac{\partial Q}{\partial x}=0,\qquad \frac{\partial Q}{\partial t}+\frac{\partial}{\partial x}\!\left(\frac{Q^2}{A}\right)+\frac{A}{\rho}\frac{\partial p}{\partial x}=-\frac{f\,Q}{A},\qquad p=p_{\mathrm{ext},e}(t)+\beta_e\!\left(\sqrt{A}-\sqrt{A_{0,e}}\right). $$
Here $\rho$ is blood density, $f$ a friction coefficient, $A_{0,e}$ the unloaded area, and $\beta_e$ the wall stiffness of segment $e$. The term $p_{\mathrm{ext},e}(t)$ is the band pressure, nonzero only on the compressed segment. For conventional access that is the forearm radial trunk. For distal access it is the snuffbox segment, beyond the origin of the superficial palmar branch. Junctions conserve flow and pressure, including around the closed arches.
Simulations will span the hidden variables that decide the clinical question. These are arch completeness (complete, incomplete superficial arch, and dominant-ulnar variants), segment radii, spasm expressed as reduced $A_{0}$ on proximal radial segments, heart rate and pressure, and band pressure schedules. The spasm range is informed by the proximal-predominant pattern in the optical coherence tomography study. The target quantity is a stasis index: the fraction of a time window in which cross-sectionally averaged velocity in the forearm trunk falls below a threshold. Because the threshold is not known from the file, we sweep it and report sensitivity.
Identifiability study. Using the classical solver, we will run simulation-based Bayesian inference, meaning posterior sampling over hidden anatomy given simulated observations. We will do this for several sensor sets: thumb and index fingertip pulse waveforms alone; waveforms plus band pressure; and waveforms plus one Doppler velocity reading at the wrist before compression. For each set and each access site, we report how much the posterior over the stasis index shrinks. This result stands on its own and needs no neural network.
The learned estimator. We will train an amortized estimator: one network that maps signals directly to a posterior, rather than re-running inference per patient. It operates on the arm graph and outputs a distribution over trunk flow and the stasis index. Its core unit mixes spatial message passing and temporal convolution in the same operation, in the spirit of STUM's unitized cell and DSSA-TCN's in-layer diffusion. Edge weights are made explicit functions of $p_{\mathrm{ext}}(t)$, so a change in band pressure reshapes propagation within the same step. Training combines a simulation-supervised loss with physics residuals of the equations above, computed with backward-Euler steps as in PI-MGNs, and Graflow-style junction conservation extended to loops.
Baselines
The naive reference point is the current protocol. Compression is held for the fixed interval of the access type, and trunk flow is assumed preserved after distal access and absent after conventional access. It makes one prediction per access site, so its error is the within-site spread of the true stasis index across simulated anatomies. Beating it means reducing that spread, especially by flagging the distal-access patients with incomplete arches whose trunk does stagnate.
The strongest competitor is classical simulation-based inference with the same one-dimensional solver. It gives exact physics and a principled posterior, and for a graph this small it may be accurate enough. It will receive the same simulator, the same priors, and the same observations. We run it at two budgets: unlimited compute, which serves as the accuracy reference, and a wall-clock budget matched to the learned model's inference time plus amortized training cost per 1,000 patients. The learned estimator beats it only if it matches the unlimited-budget posterior while running much faster, or beats it at the matched budget. Posterior quality is scored by calibration and continuous ranked probability score of the stasis index. There is no reported result found on Lacuna for palmar-arch or radial-trunk flow estimation of any kind. The closest reported neural-versus-classical comparison is Graflow's roughly 15% runtime reduction against an L-BFGS solver that took about 12 minutes, which was for steady flow on much larger trees. We therefore expect the speed margin on our small graph to be decided empirically, not assumed.
A feature-based baseline gives a gradient-boosted regressor hand-crafted waveform features: amplitude ratios, transit-time differences between thumb and index, and pulse shape before and after band inflation. These are the tabular features a clinical team would try first. It is trained on the same simulated data with the same tuning budget.
The key ablation is a decoupled version of our estimator: graph layers followed by a separate recurrent layer, with band pressure fed only as an input feature and not as a modulator of edge weights. Parameter count and training budget are identical. If the decoupled model matches ours, then the integrated space-time coupling argued for by STUM and DSSA-TCN adds nothing in this setting. We will report that outcome.
Why not just…?
Why not just run a classical 1D pulse-wave solver and calibrate it per patient? This is the real threat, and we treat it as the reference method, not as something to argue away. The speed arguments in the file come from large meshes and trees: over 100× for 3D shear in Suk et al., and 12-minute solves on about 1.7k-node trees for Graflow. They do not transfer automatically to a 50-segment arm. Our program is built so the identifiability result, the most durable finding, is produced by the classical method. The learned estimator must then justify itself at matched compute. If the classical method is fast enough for bedside updates every few minutes, we will say so. In that case the paper's contribution becomes the sensor-identifiability map and a validated classical estimator.
Why not just train a classifier to predict occlusion from clinical and ultrasound features? Occlusion is rare: 0.8–3.3% at three months in CONDITION and 1.9–8.5% at 24 hours in RAPID III. Half or more of early occlusions also reopen spontaneously. Any realistic cohort would therefore provide only a few dozen noisy positive labels. We instead target a mechanism, trunk flow stasis, which can be supervised by simulation and checked against Doppler in every patient, not only in those who occlude. The tabular baseline on waveform features tests whether hand-crafted features already capture that mechanism.
Why not just keep fixed compression times, since distal access already works? For the average patient it does. But the clinical argument for distal access rests on a collateral path that some anatomies lack. The same trials show a real cost to distal access: first-attempt puncture success of 70.9% versus 83.9%, and hand numbness in 20.4% versus 9.2%. A per-patient flow estimate would tell clinicians which patients need the harder puncture, and which can have their band loosened early. Fixed protocols cannot answer either question. The do-nothing baseline measures exactly how much patient-level variation they leave unexplained.
Why not just use a decoupled spatial-then-temporal network? Compression changes the graph itself at a known moment. The decoupled ablation described above tests directly whether that needs to happen inside the space-time update. Wei's bi-clustering result suggests staged inference compounds errors, but that finding comes from neural spike data, and we do not assume it carries over.
Proposed Experiments
The first experiment is the in-silico identifiability map. We simulate at least 10,000 anatomies under both access sites and several band-pressure schedules, and hold out entire arch variants to test generalization to unseen anatomy. We then report posterior contraction of the stasis index for each sensor set. The decisive check is simple. If fingertip waveforms plus band pressure cannot separate stasis from preserved flow in incomplete-arch anatomies, the bedside estimator is not viable with those sensors. We then report which additional measurement, such as a pre-compression wrist Doppler reading, restores identifiability.
The second experiment is a sanity check against the clinical trials. Across a simulated population, the mean stasis index should be clearly higher under conventional than distal compression. This ordering should hold across plausible spasm and anatomy priors, matching the direction of the occlusion gaps in RAPID III (8.5% vs 1.9%) and Wang et al. (9.0% vs 2.0%). We claim only the direction, not calibration to those rates. If the simulator fails this ordering, its priors or its compression model are wrong, and everything downstream is suspect.
The third experiment is the estimator comparison against the four baselines above. We measure posterior calibration, continuous ranked probability score, and area under the ROC curve for detecting stasis above threshold. All are reported separately for complete and incomplete arches and for spasm and no-spasm cases, together with wall-clock inference time. As a secondary test of the physics loss, we check that on Paetzold-style synthetic trees under steady inflow (the Graflow setting), our estimator's junction-conservation residual matches a steady-state solver. This confirms we have not broken the steady case while adding time.
The fourth experiment is a small prospective observational pilot, roughly 60 patients split between access sites, with no change to care. Fingertip waveforms and band pressure are recorded throughout compression. Forearm radial Doppler, the same modality used as the endpoint in CONDITION and RAPID III, is recorded at fixed intervals as ground truth. The decisive check is whether the estimated stasis index discriminates Doppler-confirmed absent or near-absent forearm flow from preserved flow better than the access-site-only rule. Learned and classical estimators are compared head to head on the same recordings. Any link to later occlusion is reported descriptively only; the pilot is not powered for it.
References
- Comparison of long-term radial artery occlusion via distal vs. conventional transradial access (CONDITION): a randomized controlled trial
- Distal radial access to prevent radial artery occlusion for STEMI patients (RAPID III): a randomized controlled trial
- Early prevention of radial artery occlusion via distal transradial access for primary percutaneous coronary intervention
- Assessment of acute radial artery injury after distal transradial access for coronary intervention: an optical coherence tomography study
- Graflow: Neural Blood Flow Solver for Vascular Graph
- $\mathrm{SE}(3)$-equivariant hemodynamics estimation on arterial surface meshes using graph convolutional networks
- Physics-informed MeshGraphNets (PI-MGNs): Neural finite element solvers for non-stationary and nonlinear simulations on arbitrary meshes
- Cross Space and Time: A Spatio-Temporal Unitized Model for Traffic Flow Forecasting