Sector Votes: Learning Mammogram Localization from Cheap, Disputed Quadrant Labels and the Other Breast

Drawing precise lesion outlines on medical images is slow, needs scarce specialists, and still yields "ground truth" that two radiologists would draw differently. This proposal collects a different kind of label. Several readers each answer one fast question for every anatomical sector of a mammogram, such as the upper-outer quadrant: "is anything suspicious here?" The fraction of readers who say yes becomes a soft label for that sector. A model is then trained to predict that fraction by comparing each sector with the mirror-image sector of the same patient's other breast. In plain terms, the study replaces one expensive, falsely certain outline with several cheap, honestly uncertain votes on a coarse grid. It also gives the model the patient's own healthy side as a reference point.

The bet is that these two choices help each other. Sector votes are cheap because the sectors are coarse. Disagreement between readers then stops being noise and becomes the training target. The contralateral sector helps separate sectors that are disputed because the tissue is genuinely ambiguous from sectors that are disputed because the patient's breasts are naturally a little different. If this works, it gives a label-efficient route to localization in which reader disagreement is measured rather than averaged away. It also gives a concrete, falsifiable account of where that disagreement comes from.

Core Claim

Consider training budgets measured in reader-minutes rather than number of images. Under such a budget, a model trained on multi-reader votes at the sector level, with each sector compared against its mirror sector, will localize lesions as well as models trained on single-reader masks or boxes. It will localize better than models trained on image-level labels alone. It will also predict how much held-out readers agree on each sector, which no existing method in this space attempts.

The claim has a second, separable part. The prediction error that remains on contested sectors should shrink specifically when the contralateral comparison is added. That would show bilateral comparison is doing work that single-image disagreement models cannot do.

Why This, and Why It Is Not Already Done

The closest existing work is the counterfactual generating network of Bilateral Asymmetry Guided Counterfactual Generating Network for Mammogram Classification, here called CGN. CGN uses the other breast to synthesize a "healthy" version of the diseased breast's features and finds lesions from image-level labels alone. On INbreast it reports a classification area under the curve (AUC) of 91.1% and a top-1 localization error of 0.421, against 0.632 for CycleGAN. CGN supplies the motivation: patient-specific bilateral reference beats population-level healthy references. It differs from this proposal in three ways. It treats each image label as certain. It finds lesions with unconstrained class-activation maps rather than anatomical sectors. And it deliberately works in feature space to avoid registering deformable breast tissue.

Contralaterally Enhanced Networks for Thoracic Disease Detection, here called CEN, supplies part of the method. It reflects each candidate region across the spine, refines the pose of the mirror patch with a small learned warping module, and subtracts features so that symmetric anatomy cancels out. Rib-abnormality detection AP50 rose from roughly 20% to 50%. We reuse that local mirror-and-warp idea inside each sector.

The multi-rater line constrains the design and also motivates it. Calibrate the inter-observer segmentation uncertainty via diagnosis-first principle (DiFF) weights raters by how much their masks help a downstream diagnosis. Learning Calibrated Medical Image Segmentation via Multi-Rater Agreement Modeling (MRNet) reconstructs each rater's mask to build pixel-level disagreement maps. Probabilistic Modeling of Inter- and Intra-observer Variability in Medical Image Segmentation (Pionono) gives each rater a learned latent distribution. All three show that collapsing raters to a majority vote loses information. All three, however, require dense multi-rater masks and look at the target image in isolation.

The research file is explicit about the gap this leaves. Dense multi-rater cohorts are rare, and no method uses the contralateral organ to decide whether a disagreement reflects pathology or benign anatomical variation. Our contribution is to make multi-rater data cheap by coarsening its spatial unit. The spatial-partitioning literature gives that coarsening clinical legitimacy. Sector analysis in the retina, for example in Quadrant asymmetry alteration of retinal degeneration in thyroid-associated ophthalmopathy, and local subregions in bone, as in Opportunistic osteoporosis screening in multi-detector CT images via local classification of textures, both show that focal signals survive coarse partitions but are diluted by global averaging.

Research Program

The partition is a breast-specific coordinate frame. In each standard view, the nipple and the pectoral muscle line define an origin and an axis. Within that frame we define angular sectors at two radial depths, and the same frame is defined on the opposite breast in the same view. We will compare three granularities: 4 quadrants, 8 sectors, and 12 clock-hour sectors at two depths. This tests the file's open problem about the trade-off between spatial resolution and signal-to-noise. To handle deformation and asymmetric compression, sector boundaries are soft, meaning pixel membership tapers across borders. Each mirror sector also passes through a small learned warp, in the style of CEN, before features are compared.

Labels come from a dedicated reader study. A pool of $R$ radiologists sees bilateral exam pairs. For each sector of each breast they give a binary "suspicious" flag, and we log how long each exam takes. On a subset, the same readers also draw boxes, and one reader draws masks, so that cost per label type is measured rather than assumed. For sector $s$, the soft label is $y_s = k_s / R$, where $k_s$ is the number of readers who flagged it.

The model encodes sector $s$ and its warped mirror sector $m(s)$ with a shared backbone. The sector's own features are kept alongside the difference features, so that disease present in both breasts is not cancelled out, which is the failure mode noted by Chen and Liu (2023). A small head outputs $p_s$. Training minimizes cross-entropy against the soft vote, plus a consistency term tying the most suspicious sector to the image-level label $c \in \{0,1\}$:

$$ \mathcal{L} = -\sum_s \big[\, y_s \log p_s + (1-y_s)\log(1-p_s) \,\big] \;+\; \lambda\, \mathrm{BCE}\!\left(\max_s p_s,\; c\right), $$

where BCE is binary cross-entropy and $\lambda$ weights the image-level term.

A rater-conditioned variant replaces $y_s$ with each reader's own flags and gives each reader a learned embedding, following Pionono. This tests whether modeling individual reader style matters at the sector level or whether the vote fraction is already enough.

Analysis has two parts. First, we test whether contralateral asymmetry predicts disagreement: is the vote fraction $y_s$ highest at intermediate asymmetry? Second, we check whether flags from the most "lenient" readers concentrate in sectors whose asymmetry is benign, meaning sectors that are not confirmed by biopsy or follow-up. That is the physiological-asymmetry concern raised by Fineide et al. (2022).

Public data supports pretraining and single-reader evaluation without any new collection. Lesion locations in VinDr-Mammo and the masks in INbreast and CBIS-DDSM convert directly into sector labels. The reader study adds the multi-reader layer on a few hundred exam pairs.

A secondary, smaller test uses the Acute Ischemic Stroke Dataset (AISD) of non-contrast brain CT. The brain's natural partition into regions, as used in the regional ASPECTS score, matches the sector design, and the symmetry-attention model of Symmetry-Enhanced Attention Network for Acute Ischemic Infarct Segmentation with Non-contrast CT Images (SEAN) shows that hemisphere comparison matters there. It reports Dice 0.5784 against 0.4588 for a U-Net. That test would show whether the approach transfers beyond the breast.

Baselines

The naive reference point is an image-level ResNet50 classifier with class-activation maps for localization, given only the image label and no contralateral input. CGN reports this backbone at 82.7% AUC on INbreast. Every method uses the same ResNet50 backbone, the same patient-level splits (five splits, matching Mammo-Clustering's protocol), and the same hyperparameter search budget.

The strongest weakly supervised competitor is CGN itself. We will run it from image labels on the same splits and score its localization by sector hit rate and by its reported top-1 localization error. Its reported values are 91.1% AUC and 0.421 localization error on INbreast. Beating it means lower localization error and higher sector-level AUC at equal or lower annotation time. Matching its classification AUC is the minimum requirement.

The strongest multi-view competitor on VinDr-Mammo is Mammo-Clustering. It reports AUC 0.828 ± 0.020, weakly supervised localization recall 68.5%, and miss rate 29.4%. Beating it requires higher recall at a matched miss rate.

The fully supervised reference is a mask-trained dual network as in Dual Convolutional Neural Networks for Breast Mass Segmentation and Diagnosis in Mammography, which reports Dice 93.69% on INbreast. We do not expect to beat its pixel-level Dice. The comparison that matters is sector localization at equal reader-minutes, plotted as a learning curve against annotation time.

Three ablations isolate the key ingredients. The first is the same sector model trained on majority-vote binary labels instead of vote fractions, which isolates the multi-reader signal. The second is the same model with the mirror-sector branch removed, which isolates the bilateral comparison. The third is the rater-embedding variant, which tests whether individual reader styles add anything beyond the vote fraction.

Why not just…?

Why not just use image-level labels, as CGN does, and skip the reader study? Image labels cost almost nothing, and CGN already localizes well. This is a real threat. If CGN localizes as well per reader-minute, sector votes are not worth collecting. The annotation-time learning curve settles the question directly. We also note that CGN cannot output reader agreement at all. Agreement prediction is a capability CGN lacks, separate from any accuracy advantage.

Why not just have one radiologist draw boxes and train a standard detector? Boxes are a familiar format, and CEN shows that detectors gain from contralateral fusion. However, a single reader's box hides exactly the disagreement that DiFF and MRNet show to be informative. Boxes are also slower to draw than sector flags, a claim the timed reader study will either confirm or refute. The box-trained detector with CEN-style fusion is included at matched reader time. If it matches us on localization, the remaining contribution reduces to agreement prediction, and we would say so.

Why not just average the votes, treating them as label smoothing on an ordinary model? That is precisely the "no mirror branch" ablation. If the bilateral branch brings no improvement on contested sectors, the bilateral half of the claim is false.

Why not just feed the flipped contralateral image as extra input channels to a dense network and drop the explicit sectors? A sufficiently capable network might learn the comparison on its own. CGN, however, argues that pixel-level alignment of deformable breasts is unreliable, and the partitioning literature reports dilution of focal signals under global processing. We test this directly with a channel-concatenation model trained under the same sector-pooled loss. If that model matches the explicit sector model, the partition serves only as a labeling unit and not as an architectural one. That would be a useful finding in its own right.

Decisive Checks

Three results would decide the proposal.

The first is the reader-minute learning curve on VinDr-Mammo and INbreast. Sector votes must dominate image labels, as in CGN, and at least match single-reader boxes. Otherwise the cost argument fails.

The second is calibration against held-out readers. On the reader-study subset, predicted $p_s$ is scored against the vote fractions of readers excluded from training, using Brier score and calibration error. The mirror branch must reduce error mainly on contested sectors, those with $0.2 < y_s < 0.8$. Otherwise the bilateral half of the claim fails.

The third is stratified failure analysis. Performance is reported separately on exams with findings in both breasts and on exams with large benign asymmetry, confirmed by follow-up. This makes visible where contralateral reference helps and where it misleads.

A negative result on the second check would still be informative. It would mean reader disagreement in mammography is not explained by bilateral anatomy, which runs against the intuition behind Gap 3 in the literature.