Many claims about topological materials rest on whether a band is split in two. Spin-orbit coupling is the interaction between an electron's spin and its motion, and in these materials it often separates bands by only a few millielectronvolts. Two instruments see this splitting differently. Photoemission spectroscopy (ARPES), which images band energy against momentum, shows where in momentum space the bands sit. Once its energy resolution is coarser than the splitting, though, two bands blur into one. Quantum oscillation measurements (de Haas–van Alphen, dHvA) record magnetization wiggles periodic in inverse magnetic field. They can separate nearly equal Fermi-surface areas with very fine precision, but they give no momentum map, and their frequency resolution is set by how wide a field window was swept.
Speaker verification has faced the same structure for decades. A short, noisy recording forces a system to combine a broad, channel-robust stream with a sparse, distinctive one, and the right mixing weight changes with recording length. We propose treating "is this band split?" as a verification trial. Each instrument produces a calibrated likelihood ratio. The two are combined with a weight that depends on each instrument's effective resolution, and the result is scored the way speaker verification is scored, with equal error rates and detection cost as a function of resolution. The deliverable is a detector together with a resolution operating curve: a principled answer to "at what energy resolution and field window can this splitting be claimed?"
Core Claim
The speaker-verification literature shows something specific: the optimal weight on the secondary stream depends on how degraded the primary stream is. Combining source and system information for limited data speaker verification fused vocal-tract spectral features (MFCCs) with glottal-source features. The tuned weight on the source score rose from 0.15 for 10-second test clips to 0.40 for 2-second clips, as the MFCC-only error rate grew from 5.81% to 22.31%. Speaker Verification Using Short Utterances with DNN-Based Estimation of Subglottal Acoustic Features instead fixed the weights at 0.85/0.15 across conditions, and the research file names this static weighting as an open limitation.
Splitting detection has two natural "durations." The first is the ARPES resolution ratio $r_A = \delta E / \Delta E$, the instrument-plus-thermal linewidth relative to the hypothesized splitting. The second is the dHvA ratio $r_Q = 1 / (F_{\text{sep}}\, W)$, where $F_{\text{sep}}$ is the frequency gap between the hypothesized pair of orbits and $W$ is the inverse-field window width. The form of $r_Q$ follows from the fact that a Fourier transform over a window of width $W$ resolves frequencies only to about $1/W$.
Our claim is that a fused log-likelihood ratio with a resolution-conditioned weight,
$$\Lambda = \big(1-\alpha(r_A, r_Q)\big)\,\ell_A + \alpha(r_A, r_Q)\,\ell_Q,$$
gives lower detection error than either stream alone and lower error than a fixed-weight fusion. Here $\ell_A$ and $\ell_Q$ are the calibrated split-versus-unsplit log-likelihood ratios from ARPES and dHvA, and $\alpha$ is a small monotone function learned on simulated trials. The gain should be largest in the crossover regime $r_A \approx 1$, which is where weak-spin-orbit compounds such as CoSi currently fall (Observation of unconventional chiral fermions with long Fermi arcs in CoSi).
Why this framing and not a neural fusion network
The research file proposes the obvious alternative at this intersection: a dual-branch neural network that takes ARPES cuts in one branch and dHvA spectra in another, modeled on Fine-tune Pre-Trained Models with Multi-Level Feature Fusion for Speaker Verification or the local-global design of Branch-ECAPA-TDNN. The file finds no such work.
We decided against making it the core proposal. Labeled real data for sub-resolution splittings is essentially nonexistent. A black-box fusion trained on simulations would be hard to trust for a physics claim. A likelihood fit through a physical forward model is the method a physicist would use anyway.
What transfers from speech is therefore not the architecture. It is three things: score-level fusion of calibrated per-stream evidence, a fusion weight conditioned on degradation, and an evaluation protocol based on error rates and detection cost. Neural feature extraction appears only as an optional input to the ARPES stream. The ARPES work in the file motivates this caution. Transfer Learning Application of Self-supervised Learning in ARPES reached 92.94% gapped/gapless classification with DINO features and a 20-nearest-neighbor classifier on Fe₃Sn₂. Unsupervised clustering of the same features fell to 50–60%. Generic image features carry phase information, but only reliably with labeled guidance.
Research Program
ARPES stream. The ARPES stream computes $\ell_A$ through a forward model. A tight-binding dispersion with or without the split is passed through a Lorentzian intrinsic linewidth. It is multiplied by the Fermi function at temperature $T$, convolved with a Gaussian resolution kernel, and given Poisson counting noise. The log-likelihood ratio comes from maximum-likelihood fits under the two hypotheses, followed by an explicit calibration step. That step uses logistic regression on held-out simulated trials, the standard speaker-verification practice, so that $\ell_A$ means the same thing across materials.
Preprocessing reuses the twin-network grid removal of Removing grid structure in angle-resolved photoemission spectra via deep learning method. That paper splits a raw spectrum into clean bands, detector-mesh texture and sparse noise, and avoids the band erasure that Fourier filtering causes when bands overlap the grid frequency. Noise and background statistics for the simulator are drawn from the 46-dataset, 19-material ARPESNet library of An autoencoder for compressing angle-resolved photoemission spectroscopy data. Its noise-to-noise trained autoencoder also serves as an alternative denoiser in an ablation.
dHvA stream. The dHvA stream computes $\ell_Q$ by fitting the oscillatory magnetization with the Lifshitz–Kosevich form, using either one or two close frequencies. Amplitude damping is constrained by the effective mass, which is fit from the temperature dependence. The test case is the behavior reported in Quantum oscillations and electronic structure in the large–Chern number semimetal RhSn: the two high frequencies seen with field along [001] evolve into four as the field rotates toward [110]. That rotation provides a natural series of trials with varying $F_{\text{sep}}$.
Fusion weight. The weight $\alpha(r_A, r_Q)$ is a two-input logistic function, constrained to be monotone in each argument. It is fit on simulated development trials and then frozen.
Trial construction. Trials pair a material, a momentum region and a hypothesized splitting. Target trials are genuinely split; non-target trials are unsplit but otherwise matched in dispersion and broadening. The heavy-element cases PtGa (Quantum Oscillations and Electronic Structure in the Large-Chern-Number Topological Chiral Semimetal PtGa*) and RhSn give model parameters with known, resolvable spin-orbit splitting and twelve and ten measured dHvA frequencies respectively. We then scale the spin-orbit strength down toward CoSi-like values to sweep $r_A$ through 1.
Real-data check. The first real-data check uses Fe₃Ge (Orbital-selective effect of spin reorientation on the Dirac fermions in a non-charge-ordered kagome ferromagnet Fe3Ge). There the Dirac point DP1 goes from gapped at about 50–60 meV to nearly gapless below about 170 K, while DP2 stays gapped at about 100–120 meV. Taking high-resolution cuts, broadening them artificially and adding counting noise yields real trials whose ground truth is fixed by the undegraded data. Obtaining these cuts requires access to the authors' data, which we will request. If access fails, the protocol falls back to simulation plus whatever public ARPES cuts the ARPESNet library contains.
Baselines
Naive single-stream references. The first is ARPES-only: fit one or two Lorentzians to energy distribution curves and decide by an information-criterion threshold, which is what an experimenter typically does by eye. The second is dHvA-only: count peaks in the Fourier spectrum of the oscillations. Both are run on identical trials, and their thresholds are tuned on the same development split. Beating them means lower equal error rate in the crossover band $0.5 < r_A < 2$, with the improvement holding over bootstrap resamples of trials.
Fixed-weight score fusion. This follows the scheme of Speaker Verification Using Short Utterances with DNN-Based Estimation of Subglottal Acoustic Features, with one weight tuned globally on the development set. It is the direct ablation of our key ingredient. Same calibrated scores, same trials; only the weight function differs. Beating it means lower minimum detection cost averaged over the full resolution sweep, without losing at any single resolution bin.
Joint Bayesian model comparison. This is the strongest competitor. One posterior over shared band parameters is fit to both ARPES and dHvA data, and the decision uses the Bayes factor between split and unsplit models. When the forward model is correctly specified, this is the optimal detector, so it is the system we must match or beat. It gets the same forward model, priors centered on DFT values, and a sampling budget matched in wall-clock time to our pipeline. No reported result found on Lacuna for joint ARPES–dHvA Bayesian splitting detection. The nearest reported figure in the file is the 92.94% DINO phase-classification accuracy on Fe₃Sn₂ from Transfer Learning Application of Self-supervised Learning in ARPES, which addresses a different, coarser task. Beating this baseline is required only under misspecification: we expect to match it on well-specified simulations and to show lower error when matrix-element modulation, out-of-plane momentum broadening, or a wrong background shape is injected.
Learned dual-branch fusion. This is a neural network with an ARPES convolutional branch and a dHvA spectrum branch, joined by an attention fusion module of the kind in Fine-tune Pre-Trained Models with Multi-Level Feature Fusion for Speaker Verification. It is trained on the same simulated trials. We report it to test whether learned fusion adds anything beyond resolution-conditioned score fusion, and especially whether it transfers from simulation to the Fe₃Ge real-data trials.
Why not just…?
Why not just do a joint Bayesian fit of both datasets? This is a real threat, and we do not argue around it. If the physical model is exactly right, the Bayes factor is optimal and our fusion can at best tie. The case for score fusion is robustness. Each stream is calibrated separately, so a misspecified ARPES background inflates only $\ell_A$, and the resolution-conditioned weight already discounts ARPES near $r_A \geq 1$. In a joint posterior, the same error can distort the shared parameters. The misspecification sweep decides this. If the joint fit matches our method there too, the contribution narrows to the resolution operating curves and the trial-based evaluation protocol, and we will report it that way.
Why not just train a dual-branch neural network, as speech systems do? Speech systems such as Branch-ECAPA-TDNN train on thousands of labeled speakers. No comparable labeled corpus of real split and unsplit bands exists. The unsupervised-clustering collapse reported in Transfer Learning Application of Self-supervised Learning in ARPES warns that image features do not organize physical phases unaided. We still include the network as a baseline. If it beats score fusion on the real Fe₃Ge trials and not only on simulations, we would change our recommendation.
Why not just rely on dHvA plus DFT, as the PtGa and RhSn studies did? Those studies succeeded because heavy Pt and Rh make the splitting large. The dHvA-only baseline tests the alternative directly. Its known weakness is that frequency pairs cannot be assigned to momentum locations without DFT. Our trials therefore include cases where DFT places a competing unsplit orbit at a similar frequency. In those cases the ARPES stream should carry the decision even when it is blurred.
Why not just sharpen the ARPES image by deconvolution or Fourier filtering? Removing grid structure in angle-resolved photoemission spectra via deep learning method shows Fourier masking erasing real band features where they overlap artifact frequencies. Generic deconvolution amplifies Poisson noise exactly in the low-count regime of interest. We include a Richardson–Lucy-deconvolved ARPES-only detector as an extra arm, so that its error at each $r_A$ is measured rather than assumed.
Proposed Experiments
Experiment 1: simulated resolution sweep. Spin-orbit strength is scaled from PtGa- and RhSn-like values down to CoSi-like values, with ARPES resolution, temperature and dHvA field window varied independently. For every detector we plot equal error rate and minimum detection cost as functions of $r_A$ and $r_Q$. The decisive check has two parts. The learned $\alpha$ must rise as ARPES degrades, the counterpart of the 0.15-to-0.40 shift in Combining source and system information for limited data speaker verification. And resolution-conditioned fusion must beat fixed-weight fusion in the crossover band. If $\alpha$ comes out flat, the core claim fails.
Experiment 2: misspecification stress test. Matrix-element modulation, out-of-plane momentum broadening and wrong backgrounds are injected into the ARPES data at test time only. This experiment decides between our method and the joint Bayesian baseline.
Experiment 3: real-data transfer. Using broadened Fe₃Ge cuts across the 170 K transition, plus RhSn's rotation-dependent frequency branches as dHvA trials, we check that detectors calibrated on simulation keep their stated error rates. Calibration drift, measured as the gap between actual and minimum detection cost, is the honest test of whether these operating curves can guide decisions such as how much resolution a beamtime proposal must request to claim a CoSi splitting.
References
- Combining source and system information for limited data speaker verification
- Speaker Verification Using Short Utterances with DNN-Based Estimation of Subglottal Acoustic Features
- Observation of unconventional chiral fermions with long Fermi arcs in CoSi
- Fine-tune Pre-Trained Models with Multi-Level Feature Fusion for Speaker Verification
- Branch-ECAPA-TDNN: A Parallel Branch Architecture to Capture Local and Global Features for Speaker Verification
- Transfer learning application of self-supervised learning in ARPES
- Removing grid structure in angle-resolved photoemission spectra via deep learning method
- An autoencoder for compressing angle-resolved photoemission spectroscopy data
- Quantum oscillations and electronic structure in the large–Chern number semimetal RhSn
- Quantum Oscillations and Electronic Structure in the Large-Chern-Number Topological Chiral Semimetal PtGa*
- Orbital-selective effect of spin reorientation on the Dirac fermions in a non-charge-ordered kagome ferromagnet Fe3Ge