When you measure the redox state of a cell culture, which is roughly how "charged" its electron-carrying molecules are, you get one averaged number or spectrum per time point. Protein biophysics has shown repeatedly that a molecule's redox state and the speed of its electron transfer can change independently. Mutations can shift a ferredoxin's redox potential and leave its transfer rate untouched. Other changes leave binding or driving force intact while slowing transfer sharply. If the two axes come apart in single proteins, they can come apart across cells. A culture can then hold fast and slow subpopulations whose average steady state looks exactly like a uniform culture's. Genomics knows this failure well: averaging over cells hides rare subpopulations. Its fix is deconvolution, which means inferring the distribution of single-cell profiles that must have summed to the bulk measurement.
This note proposes doing that two-axis deconvolution for redox biology. The input is bulk, time-resolved Raman spectra recorded after a light or chemical perturbation. Raman spectroscopy measures molecular vibrations, so different spectral bands report different chemical groups and redox centers. The output is the per-cell joint distribution of steady redox state and relaxation rate. Two pieces of prior work make this possible. Single-cell Raman spectra serve as the reference "atlas", and a generative model built for integer counts serves as the prior, with the constraint that sampled cells must sum exactly to the measured bulk. The claim is specific and falsifiable. Some pairs of cell mixtures have the same average equilibrium spectrum but different kinetic make-up. No equilibrium bulk method can tell such pairs apart, and this method should.
Core Claim
The physical motivation comes from Direction 1.
- Potential and rate move independently. Cluster-binding-loop mutants of Anabaena ferredoxin shift the reduction potential without changing the electron transfer rate to its partner reductase (Weber-Main et al.).
- A large potential shift can leave transfer intact. Cysteine-to-serine mutants shift the potential by +55 mV and still transfer electrons competently (Hurley et al.).
- Binding and intrinsic rate move independently. Deleting the PsaD or PsaE docking subunits of Photosystem I weakens ferredoxin binding, but leaves the intrinsic transfer rate within the bound complex unchanged (Lagoutte et al.).
- Favorable driving force does not guarantee speed. Azurin mutants with favorable driving force are slowed by local structural strain, called frustration, which raises the energy cost of rearranging around the metal site (Chen et al.).
Taken together, these papers say that the thermodynamic axis and the kinetic axis are separate coordinates. The methodological lesson matters as much as the result. In each case the separation came from a perturbation whose response differed between the two axes. Lagoutte used flash-absorption kinetics. Grunwald et al. used temperature, which separated large first-sphere effects of 10²–10³ cm⁻¹ from small, temperature-sensitive second-sphere effects of 0–10 cm⁻¹. We borrow both the physics and this "use a perturbation dial" strategy.
The cellular problem comes from Direction 2. Yano et al. measured redox potential changes in whole Chlorella suspensions and treated the culture as one homogeneous block. We claim that bulk redox readouts of this kind confound two things:
- the fraction of cells in each redox state, and
- how fast each cell's electron-transfer chain responds.
Time-resolved bulk spectra can separate these only partially. For one spectral band $b$, let $\bar y_b(t)$ be the expected bulk photon count at time $t$ after the perturbation. Suppose each cell $i$ relaxes with amplitude $a_{ib}$ and rate $k_{ib}$. Then
$$ \bar y_b(t) - \bar y_b(\infty) = \int a\, e^{-k t}\, dP_b(a,k), $$
where $P_b$ is the population distribution of (amplitude, rate) for that band. This form follows directly from summing first-order relaxations over cells. The bulk curve is a Laplace transform of the amplitude-weighted rate distribution. The per-band marginal is therefore identifiable in principle, but recovering it is badly conditioned.
The bulk curves can never reveal which band-level kinetics occur in the same cell, because summing over cells erases that information. For example, they cannot say whether the cells with fast heme relaxation are also the cells with fast flavin relaxation. That cross-band question within single cells is exactly the cellular version of the decoupling seen in ferredoxin. Answering it requires a prior learned from single-cell data.
Research Program
We would build a deconvolution model in three parts. The bulk time-resolved Raman measurement consists of integer photon counts on a grid of bands and time points.
- Reference. We collect a single-cell reference of time-lapse Raman trajectories on a modest number of cells, using a slow perturbation protocol. This follows the non-destructive, repeated single-cell monitoring shown for CAR T cells by Stiber et al.. Stiber et al. classified cell identity and activation; they did not model kinetics or deconvolve ensembles.
- Generative prior. We train a generative model over per-cell trajectories as integer counts, using the Poisson birth-death bridge from Count Bridges. Count Bridges was built for transcript counts. Raman photon counts are equally integer-valued and Poisson-limited, and per-band counts at short exposure times are low, where treating counts as continuous breaks down.
- Deconvolution. We reuse the Count Bridges expectation-maximization scheme, in which latent single cells are the hidden variables. We also reuse its projection-guided sampling, which forces sampled cells to sum to the observed bulk. Here the sum constraint applies over the whole time course and all bands at once.
The novel ingredient is the latent structure. Each sampled cell carries an explicit steady state and an explicit rate per band, decoded through the relaxation form above. The model's output is therefore the scientific object we care about: the joint distribution of state and rate across cells and bands. It does not output cell-type fractions.
This differs from all transcriptomic deconvolution in the file. That includes Count Bridges itself, the ontology-aware bulk-to-atlas alignment in POPPY, and the reference-based tools benchmarked by the breast cancer mixture study. All of these deconvolve a static snapshot into fractions of discrete types. We deconvolve a perturbation response into continuous kinetic parameters.
The prior work plays three distinct roles here:
- Motivation: scSet. Its analysis argues that pseudobulk averaging cannot see "equal and opposite" population shifts that cancel in the mean. That is the transcriptomic analogue of our equal-mean redox mixtures.
- Constraints: the breast cancer benchmark and the spatial deconvolution benchmark. They show reference dependence and a "purity trap", where a dominant population with a similar signature absorbs a minority. We expect the same failure when a small fast subpopulation sits inside a large slow one, and we design experiments to measure it.
- Method: Count Bridges.
We work in photosynthetic microbes because they offer a clean perturbation (a light flash), established bulk redox assays (Yano's Chlorella), and existing mutants whose effects split along the two axes (Lagoutte's Synechocystis PsaD/PsaE deletions).
Ground-truth heterogeneity comes from two sources:
- Physical mixtures. We combine separately grown, labeled populations at known ratios, for example wild type with a PsaE deletion strain, or untreated cells with cells pretreated with a photosynthetic electron-transport inhibitor. We sweep the minority fraction from 5% to 95%, matching the design of the breast cancer benchmark.
- In-silico mixtures. We resample single-cell trajectories so that pairs of mixtures share the same mean equilibrium spectrum but differ in rate distribution.
We do not know in advance whether the PsaE deletion shifts in vivo relaxation enough to be detectable. The inhibitor mixtures are the fallback with a guaranteed kinetic difference.
Baselines
The naive reference point fits each band's bulk time course with a single exponential and compares mixtures by their mean equilibrium spectrum and mean rate. This is the implicit model behind bulk redox assays. On the equal-mean mixture pairs it should be at chance on the equilibrium readout by construction. On the time-resolved readout it should be only partly better. Beating it means telling equal-mean pairs apart and recovering the minority's rate, not just a shifted mean.
The strongest classical competitor is reference-based linear unmixing on time courses. We fit each bulk trajectory as a nonnegative combination of per-cluster mean trajectories from the single-cell reference, using nonnegative least squares. This is the standard chemometric approach, and we found no Lacuna citation for it. We also run a Bayesian count-based unmixer in the style of BayesPrism, applied to photon counts. BayesPrism and DWLS had the lowest combined false positives and false negatives in the breast cancer mixture study. That study reports qualitative rankings rather than a single scalar, and we found no reported result on Lacuna for Raman or redox-kinetic deconvolution.
For fairness, every method gets the same single-cell reference, the same bulk data, the same held-out mixtures, and the same hyperparameter search budget. Clusters for the linear methods are chosen by the same validation split we use to tune our model. Beating these baselines means two things:
- lower 2-Wasserstein distance between the recovered and true joint state-rate distribution, at every minority fraction below 20%;
- a lower combined false-positive and false-negative rate for detecting the presence of a minority kinetic subpopulation.
Three ablations isolate our key ingredients:
- Static Count Bridges treats each time point as an independent snapshot, removing the explicit kinetic latent. It tests whether the two-axis structure matters.
- Continuous version replaces the Poisson bridge with continuous flow matching. It tests discreteness. Count Bridges reports lower 2-Wasserstein distance and energy score than continuous and discrete flow matching on synthetic data, but gives no scalar in the file. We expect the advantage to appear only at low photon counts, meaning short exposures or fast early time points.
- Single-band version uses one band instead of several. It tests whether multiple redox centers help recover the cross-band structure.
Why not just…?
Why not just measure every cell with single-cell Raman and skip deconvolution? This is the most serious threat. For slow kinetics on a few hundred cells it is simply better, and that is exactly how we build our reference and ground truth. Point-scanning single-cell Raman collects cells one after another, however. It cannot record thousands of cells' simultaneous responses to a single flash at sub-second resolution, while a bulk measurement can. Existing bulk electrode and spectroscopic redox assays also cannot be redone cell by cell after the fact.
We will settle the question directly. At a matched total acquisition time, we compare distribution recovery from single-cell time-lapse with recovery from bulk measurement plus deconvolution, across perturbation timescales. If single-cell acquisition matches us everywhere, the method's value shrinks to the fast-kinetics regime, and we will say so.
Why not just unmix with reference spectra by nonnegative least squares? If cells really fall into a few discrete kinetic types with distinct spectra, linear unmixing on time courses should do about as well as our method. Our physical-mixture experiments with two labeled strains are close to that case, so they could show a tie. Our method should win when two conditions hold:
- rates vary continuously within types, which a cluster mean cannot represent;
- the minority shares the majority's static spectrum, which is the analogue of the purity trap.
The in-silico equal-mean mixtures with continuous rate spread test exactly this. If NNLS ties there too, the generative machinery is unnecessary.
Why not just fit a multi-exponential, or invert the Laplace transform, on each bulk band? This recovers each band's amplitude-weighted rate distribution with no reference at all. Where it is stable, it is a fair partial answer, and we include it as a baseline. It cannot say whether fast relaxation in one band and fast relaxation in another occur in the same cells. That coupling is information the bulk sum discards, and recovering it requires a single-cell prior.
The danger is the converse: our prior could impose a coupling the data do not support. We test for this with mixtures whose cross-band coupling is known. In one condition we pair an inhibitor that slows one redox center with an unrelated pretreatment that alters another, applied to separate or to the same subpopulations. We then check that the recovered coupling follows the truth rather than the reference.
Proposed Experiments
The first stage is in silico. We build a single-cell time-lapse reference from our own cultures, then generate mixtures. Some sweep the minority fraction from 5% to 95%. Others form equal-mean pairs that share their average equilibrium spectrum. We score every method on four metrics:
- 2-Wasserstein distance and energy score between the recovered and true joint distributions;
- error in the minority's estimated fraction and rate;
- area under the ROC curve for telling equal-mean pairs apart;
- combined false-positive and false-negative rate for detecting the presence of a minority.
The second stage moves to physical mixtures of labeled Synechocystis or Chlorella populations, measured in bulk after a flash. A subset is also tracked as single cells, which supplies the truth.
Three checks decide the outcome:
- Equal-mean pairs. On pairs that equilibrium bulk methods cannot separate by construction, our method should reach an AUC clearly above the single-exponential and multi-exponential baselines.
- Detection floor. The smallest minority fraction we can detect should be lower than for NNLS and the Bayesian unmixer, at an equal false-positive rate.
- Resolution limit. We measure honestly how close two rates can be before the method can no longer tell them apart. Laplace inversion predicts a limit set by the photon-count noise, and we report where that limit lies.
If all three checks pass, bulk redox biology gains a way to see the kinetic heterogeneity that single-protein studies predicted. If the NNLS tie or the single-cell comparison wins, we will have mapped precisely where the simpler tools are enough.
References
- An Electrochemical, Kinetic, and Spectroscopic Characterization of [2Fe–2S] Vegetative and Heterocyst Ferredoxins fromAnabaena7120 with Mutations in the Cluster Binding Loop
- Iron-Sulfur Cluster Cysteine-to-Serine Mutants of Anabaena [2Fe-2S] Ferredoxin Exhibit Unexpected Redox Properties and Are Competent in Electron Transfer to Ferredoxin:NADP+ Reductase
- Ferredoxin Reduction by Photosystem I from Synechocystis sp. PCC 6803: Toward an Understanding of the Respective Roles of Subunits PsaD and PsaE in Ferredoxin Binding
- Frustration Dynamics and Electron-Transfer Reorganization Energies in Wild-Type and Mutant Azurins
- Disentangling First and Second Sphere Effects in Iron–Sulfur Cubanes
- Oxidation and Reduction by Living Chlorella Cells. V-VI. VI. The Effect of Addition of Chlorella Cells on the Oxidation-reduction Potential of Fe3+ Salts
- Dynamic, single-cell monitoring of CAR T cell identity and activation with Raman spectroscopy
- Count Bridges enable Modeling and Deconvolving Transcriptomic Data
- Cross-modal transfer learning for mapping bulk transcriptomes at cellular level
- Performance of tumour microenvironment deconvolution methods in breast cancer using single-cell simulated bulk mixtures
- A Diffusion-Based Autoencoder for Learning Patient-Level Representations from Single-Cell Data
- A comprehensive benchmarking with practical guidelines for cellular deconvolution of spatial transcriptomics