Systems that write chest X-ray reports increasingly work in two steps. A vision model first predicts a structured list of findings, and a language model then turns that list into prose. The structured list is a graph of anatomy and observations such as "small left pleural effusion, definitely present." This split reduces invented findings, but it has a known weakness. If the vision model misses a finding, nothing downstream can bring it back. We propose a remedy built from an unusual kind of domain-specific pre-training. Every available radiology report, including reports from hospitals that released no images, is converted into the same structured graph format. A small language model is then pre-trained on these graphs, so it learns which findings tend to appear together, where, and with what certainty. At test time this model never writes findings into the report. It only proposes findings that are likely missing, and the vision model, shown the relevant anatomical region, must confirm each one before it is accepted.
The opportunity is that paired image–report data is scarce and tied to particular hospitals, while report text is plentiful. Text written in a normalized graph schema should also be far less affected by each hospital's habits of phrasing. If a prior learned from text alone can recover the vision model's omissions without adding findings the image does not support, then domain pre-training finally has a principled place inside an image-to-text pipeline. It serves as a source of hypotheses, not as a fluent narrator that drowns out the image.
Core Claim
A domain language model pre-trained on serialized report graphs can raise recall of clinical findings when it is used only to propose candidates for image-conditioned verification. This proposal step should improve clinical accuracy over a one-way image-to-graph-to-report pipeline. It should also beat a co-occurrence table and a text-pretrained biomedical model used the same way. Graph-space pre-training should transfer across hospitals better than raw-text pre-training. These are three separable claims, and each has its own decisive test below.
What Prior Work Establishes and Leaves Open
The two-step design comes from Style-Aware Radiology Report Generation with RadGraph and Few-Shot Prompting. That system has a DenseNet with a Transformer decoder that predicts a serialized RadGraph, which gpt-3.5-turbo then verbalizes. It reports RadGraph F1 of 0.228 against 0.186 for its baseline. The authors note the flaw we target: the pipeline runs one way only, so missed entities cannot be recovered. Their verbalizer is also a closed, general-purpose API. The graph schema and extractor come from RadGraph, a PubMedBERT-initialized extractor. It reaches micro F1 of 0.94 for entities and 0.82 for relations on MIMIC-CXR, and its schema covers roughly 87–92% of findings and impression sentences. Its accuracy is what makes converting text-only reports into graphs credible. We reuse it as a data-generation tool, not as an evaluator alone.
Two results constrain the design. Rethinking Radiology Report Generation shows with a "blank image test" that autoregressive report models gradually stop looking at the image. Its fix, LLaVA-TA, generates each topic independently using the full radiograph plus a mask of the anatomical region. Similarly, Self-Captioning Multimodal Interaction Tuning finds that pushing more information into text reduces errors caused by the image but raises errors caused by language priors. Both warn that a strong language prior fused directly into prediction will produce findings the image does not support. Our proposer is therefore barred from changing any score. It can only choose which questions the vision verifier is asked. LLaVA-TA also supplies the mechanism we reuse for verification: region-masked, per-topic conditioning.
The case for domain pre-training comes from three papers. BioBART is BART continuously pre-trained on PubMed. It finds that sentence permutation hurts biomedical generation, and its performance drops on informal clinical text. BERTHop shows that swapping BERT for BlueBERT adds 6.46% AUC in X-ray diagnosis. MonoCoder shows that undiluted in-domain corpora beat larger mixed-domain models. None of these pre-trains on the symbolic bridge itself. That is the specific difference here: the pre-training corpus is graph serializations, not prose.
The closest existing work is a group of pipelines that use a semantic bridge with general models. RadGraph+GPT-3.5 and LLaVA-TA both fall here, as do models that put discrete image tokens into a general 3B language model, such as LLM-CXR. None of them feeds information from the language side back to the image side.
Research Program
We build four components. The first is the graph corpus. We run the RadGraph extractor over all MIMIC-CXR reports, plus OpenI and any other available report text, and serialize each graph in a fixed order of anatomy-grouped entity tuples. Each tuple records the observation, its modifiers, its location, and its certainty.
The second component is the graph language model. This is a small encoder–decoder pre-trained from scratch on the serialized graphs. Its objective is masked-entity infilling: whole tuples are hidden, and the model must reconstruct them from the rest of the graph. This matches its test-time job of predicting what a partial graph is missing. A matched variant starts from BioBART weights so we can measure whether prose pre-training adds anything.
The third component is the image-to-graph extractor and verifier. The extractor follows the style-aware pipeline. The verifier follows LLaVA-TA: given the radiograph, a region mask from the same seven-region segmentation, and a candidate tuple, it outputs the probability that the tuple holds.
The fourth component is a local verbalizer. This is BioBART fine-tuned on graph-to-report pairs, which can again use text-only data, so the whole system runs on-premises.
Inference works as follows. The extractor produces a graph $G_0$. The graph language model ranks the top $k$ candidate tuples absent from $G_0$. Each candidate $e$ is accepted only if
$$p_{\text{ver}}(e \mid x, m_e) \ge \tau,$$
where $x$ is the image, $m_e$ is the mask for the anatomical region of $e$, $p_{\text{ver}}$ is the verifier's probability, and $\tau$ is a threshold tuned on validation data. The prior's score never enters this test. The one deliberate exception is an ablation that replaces the test with fusion, $p_{\text{ver}} \cdot p_{\text{LM}}^{\lambda}$, where $p_{\text{LM}}$ is the language model's probability and $\lambda$ sets its weight. That ablation measures the risk of language-prior errors. The verifier also checks every tuple in $G_0$, so the same mechanism can remove findings as well as add them.
Baselines
The naive reference points are retrieval baselines. Baselines for Chest X-Ray Report Generation reports that 1-NN retrieval reaches CheXpert macro F1 of 0.258, beating a CNN-RNN with beam search at 0.186. Evaluating Progress in Automatic Chest X-Ray Radiology Report Generation finds generative models only 5.5% better than random retrieval on RadCliQ. We rerun 1-NN with our own image encoder on the same splits. Any method that fails to clearly beat it on RadCliQ and CheXpert F1 has not earned its complexity.
The direct parent is the one-way pipeline: the style-aware RadGraph system with our local verbalizer substituted for GPT-3.5. Its published figure is RadGraph F1 of 0.228. We re-implement it with an identical extractor so that the only difference from our system is the propose–verify loop. Beating it means a statistically significant gain in RadGraph F1 and in recall of abnormal findings, with no rise in false-positive findings.
The strongest existing method in the file is LLaVA-TA. On MIMIC-CXR it reports RadGraph F1 of 44.0 and CheXpert F1-14 of 71.5, up from 29.4 and 39.5 for LLaVA-Rad. Our verifier is built on its region-conditioned design. We therefore apply our proposer on top of LLaVA-TA as well as on the lighter extractor, so the question becomes whether proposals add recall to the strongest topic-guided model. We will report both its published numbers and our reproduction. Metric variants differ across papers, so all comparisons use our reproduced scores computed with a single scoring script. Beating it means a gain on reproduced RadGraph F1 and CheXpert F1-14 at equal verifier compute.
The key ablations isolate the proposer. All proposers get the same verifier, the same $k$, and the same tuning budget for $\tau$. We compare a random proposer, a pairwise co-occurrence (pointwise mutual information) table built from the same graph corpus, BioBART pre-trained on prose and prompted with the serialized partial graph, and our graph-pretrained model.
Why not just…?
Why not just lower the extractor's detection threshold? Lowering the threshold also raises recall, at no architectural cost. However, it raises recall uniformly, and the extra findings it admits are the same low-confidence guesses the extractor already rejected. We plot precision against recall for threshold sweeps and for proposal-plus-verification. The proposal must reach a better operating point, not merely a different one.
Why not just verify every possible finding exhaustively, as LLaVA-TA's per-topic querying already does? This is the real threat. If the verifier is queried on every anatomy–observation pair, a proposer is unnecessary. That full space covers thousands of combinations once modifiers and locations are included, but a co-trained multi-label head could approximate it. We will run exhaustive verification over the full tuple vocabulary as an upper-compute baseline. If it matches our method, the honest conclusion is that the contribution is cost reduction only, and we will report it that way. Our expectation that it will not match rests on one point. Exhaustive verification learns only from paired images. The proposer's ordering comes from the much larger text-only corpus, and that ordering matters most for rare combinations, where the verifier is poorly calibrated.
Why not just use co-occurrence statistics instead of a pre-trained model? A table of which findings appear together is cheap and interpretable. The ablation tests it directly. Our hypothesis is that conditioning on the whole partial graph, including location, certainty, and modifiers, beats pairwise statistics specifically for findings with several modifiers. If the table matches the model, the pre-training claim fails, and we will say so.
Why not just prompt a large general model to fill in the missing findings? Prompting is used, with GPT-3.5, in In-context Learning for Few-shot Multimodal Named Entity Recognition. Those authors note it trails full fine-tuning when data is plentiful. It also sends patient data to an external service. We include it as a proposer on a de-identified subset only, for completeness.
Proposed Experiments
We train on MIMIC-CXR and test in-domain on its official test split. For cross-hospital transfer, we test on OpenI/IU-Xray, a dataset on which RadGraph already documents domain shift. Metrics are RadGraph F1, CheXpert F1-14, RadCliQ, recall and precision of abnormal findings, and BLEU only as a secondary check, given its documented blindness to invented findings. We use RadCliQ because the evaluation paper reports it correlates with radiologists at Kendall-tau b 0.522.
Four checks decide the outcome. First, the blank-image check: run the full loop with a black image. The accepted-proposal rate should fall to near zero, while the fusion ablation should not. This directly measures whether the prior has leaked into what gets accepted. Second, the proposer ablation at fixed verifier compute, which answers whether graph pre-training is needed. Third, cross-hospital transfer. We compare a graph-pretrained proposer and a prose-pretrained proposer, both trained on MIMIC text, and we also add OpenI report text to graph pre-training without any OpenI images. The second condition tests whether text-only data from a new hospital alone improves performance there. Fourth, a recall study stratified by finding prevalence. The proposal step should help most on findings that occur rarely alone but predictably alongside others. If the gains instead concentrate on common findings, the proposer is simply re-learning the dataset's bias toward normal findings that Contrastive Attention for Automatic Chest X-ray Report Generation warns about.
References
- Style-Aware Radiology Report Generation with RadGraph and Few-Shot Prompting
- RadGraph: Extracting Clinical Entities and Relations from Radiology Reports
- Rethinking Radiology Report Generation: From Narrative Flow to Topic-Guided Findings
- Self-Captioning Multimodal Interaction Tuning: Amplifying Exploitable Redundancies for Robust Vision Language Models
- BioBART: Pretraining and Evaluation of A Biomedical Generative Language Model
- BERTHop: An Effective Vision-and-Language Model for Chest X-ray Disease Diagnosis
- MonoCoder: Domain-Specific Code Language Model for HPC Codes and Tasks
- LLM-CXR: Instruction-Finetuned LLM for CXR Image Understanding and Generation
- Baselines for Chest X-Ray Report Generation
- Evaluating progress in automatic chest X-ray radiology report generation
- In-context Learning for Few-shot Multimodal Named Entity Recognition
- Contrastive Attention for Automatic Chest X-ray Report Generation