Physics-Based Re-Timing of Breast DCE-MRI for Cross-Site Generalization

In dynamic contrast-enhanced MRI (DCE-MRI), a contrast agent is injected and the breast is scanned several times over a few minutes. Tumors and healthy tissue can look equally bright in any single scan. What separates them is how brightness changes over time: malignant tissue tends to light up fast and then fade, while benign tissue brightens slowly and stays bright. This is the medical version of a problem remote sensing calls temporal spectral ambiguity, where crops that look identical on one date are told apart only by their seasonal trajectory (multi-temporal LSTM land cover; Sentinel-2 crop mapping in Greece). The catch in medicine is that hospitals sample this trajectory at different moments. One site takes its first post-contrast scan at 60 seconds, another at 90, and the number of phases varies. A model trained at one set of sites learns that site's sampling schedule along with the biology. On a new site it fails: the Medical Slice Transformer on the multi-center ODELIA dataset drops from 79.0% to 63.1% macro AUC externally, and its specificity at 90% sensitivity falls from 90% to 26.7% (ODELIA).

We propose to train on scans that never existed. For each training case, we fit a standard tracer-kinetic model (a two-compartment equation describing how contrast leaks from blood into tissue) to every voxel. We then use the fitted curves to re-render the case as if it had been acquired on a different site's schedule, keeping the real anatomy, texture and noise. The physics is used only to generate training data, never as the network's input. The network sees the same tumor at many plausible schedules and has to learn the part of the enhancement pattern that does not depend on when the scanner happened to fire. Manual reading motivates the target. Radiologists judge curve shape by eye from a few phases and draw masks on a single phase, and those subjective judgments are exactly what breaks when the timing changes.

Core Claim

The cross-site drop in DCE-MRI models is largely a training-distribution problem in the time axis, not a capacity problem. A physically consistent re-timing augmentation should close more of the gap than three alternatives: telling the network the acquisition times, feeding it fitted pharmacokinetic maps, or interpolating between observed phases. The precedent for this reasoning comes from cross-spectral dense correspondence. That work showed optical-flow networks failed across wavelengths because of what they were trained on, and fixed it with 18 nonlinear radiometric transfer augmentations rather than a new architecture. We apply the same logic to time. The difference is that a kinetic model, unlike a generic intensity warp, can extrapolate a curve beyond the last observed phase in a way that respects washout.

Research Program

For each training case with phase times $t_0,\dots,t_K$ read from the image file headers, we fit the extended Tofts model voxel-wise. This model describes tissue contrast as plasma volume plus leakage governed by a transfer rate and a backflux rate. Because breast protocols lack a measured arterial input, we use a population-average arterial input function. The fit uses non-linear least squares inside a breast mask, with bounds on the parameters. Fits are noisy with only three to six phases, which is why we never hand the fitted parameters to the network.

To re-time a case to a target schedule $t'_1,\dots,t'_M$, we start from the real phase nearest in time and add only the model-predicted change. The synthetic image is

$$\tilde S(t'_m) = S(t_{n(m)}) + \big[\hat C(t'_m) - \hat C(t_{n(m)})\big],$$

where $S$ is the observed signal, $t_{n(m)}$ is the observed phase closest to $t'_m$, and $\hat C$ is the fitted kinetic curve converted to signal units. Anatomy, scanner noise and annotation alignment therefore come from real data, and the kinetic model supplies only the time displacement. Where the fit residual is large, typically from motion or mixed tissue, we shrink the correction toward zero. Target schedules are drawn from the pool of schedules seen across all training sites, widened by jitter and phase dropout.

The segmentation backbone is nnU-Net with the time-conditioning layer of acquisition time-informed segmentation. That layer, Feature-wise Linear Modulation, scales and shifts features as a function of acquisition time $t$, and we reuse it unchanged. Our contribution is the training distribution, so the architecture is held fixed. For lesion classification on ODELIA we apply the same augmentation to the Medical Slice Transformer baseline.

We also run an error analysis tied to the limits of manual reading. Using the fitted curves, we classify each lesion's enhancement as persistent, plateau or washout, the categories radiologists assign visually. We then ask whether cross-site errors concentrate in plateau-type lesions, where visual curve typing is least reliable, and whether re-timing reduces errors specifically there.

Baselines

The naive reference is vanilla nnU-Net trained on the raw phases. On the external Yunnan cohort it reaches Dice 0.736 when trained on MAMA-MIA (acquisition time-informed segmentation).

The strongest directly comparable method is the time-informed nnU-Net from the same paper, which reports Dice 0.762 on Yunnan and 0.774 with Dice10 0.473 on MAMA-MIA. It is the strongest competitor because it targets exactly our failure mode, schedule mismatch, and already uses continuous time. We will retrain it with its published configuration on identical splits, with the same epochs and the same hyperparameter search budget as our model. Beating it means a Yunnan Dice gain with a bootstrap confidence interval excluding zero, plus a gain on the hard-case Dice10 metric.

The hybrid prototype network PLHN reports DSC 78.1% on Yunnan, but it was trained on 1,065 Ruijin/Guangdong cases rather than MAMA-MIA. We report it for context only, and say explicitly that this is not a controlled comparison.

For classification, the reference is the ODELIA Medical Slice Transformer: 63.1% external macro AUC and 26.7% specificity at 90% sensitivity.

Three ablations isolate the key ingredient, physical consistency of the re-timed curves. The first replaces kinetic re-timing with linear interpolation in time between observed phases, with no extrapolation beyond the last phase. The second uses re-timing without time conditioning. The third uses generic random intensity warps per phase, a direct port of the radiometric augmentations.

Why not just…?

Why not just tell the network the acquisition time? That is exactly the time-informed nnU-Net. Its 0.736 to 0.762 gain on Yunnan shows conditioning helps, but conditioning only works for times the model saw during training. A site whose schedule lies outside the training range gets an extrapolated modulation with no data behind it. Our extrapolation split, described below, is designed to expose this. If conditioning alone matches re-timing on that split, our claim fails.

Why not just fit pharmacokinetic maps and segment those? This is the most serious threat, because the maps are protocol-invariant in principle. In practice, fitting from three to six phases with a population arterial input is ill-posed. The physics-loss CNN reports that classical fitting amplifies noise and artifacts, and its own validation covers only three patients. The kinetic-curve study found dynamic features alone reached AUC 0.8253, versus 0.9080 for radiomic features, which suggests kinetic summaries discard spatial information. We will run fit-then-segment, feeding parameter maps alone and maps stacked with the raw phases, as a full baseline. If it matches us, the right conclusion is that the fitted maps already carry the invariance, and we will report that.

Why not just interpolate between phases or randomly drop phases? Interpolation cannot produce washout after the last observed phase, and it produces kinetically impossible curves between sparse phases. Whether that matters is an empirical question that the first ablation answers directly. If interpolation equals kinetic re-timing, the physics is unnecessary and the contribution reduces to schedule augmentation, which is still useful but a smaller claim.

Proposed Experiments

The training and testing setup is as follows. For segmentation, we train on MAMA-MIA (ISPY1, ISPY2, DUKE; 1,473 cases) and test on the external Yunnan cohort, if it can be obtained from the authors. In any case we also run leave-one-source-out testing within MAMA-MIA. For classification, we run leave-one-center-out testing across the six ODELIA centers, reporting macro AUC and specificity at 90% sensitivity. The specificity measure matters most clinically because it collapsed most.

The decisive check is a constructed extrapolation split. Using header timings, we train only on cases whose last post-contrast phase falls before a cutoff, then test on cases acquired at later times. Here time conditioning and interpolation have nothing to fall back on, while kinetic re-timing can generate late phases. A clear advantage on this split, together with a smaller but significant gain on natural cross-site splits, would support the claim.

The second check uses fixed anatomy. We take held-out MAMA-MIA cases, re-time them to unseen schedules, and measure how much each model's prediction changes, as Dice between predictions on the same case under two schedules. A schedule-invariant model should change little. Because these synthetic test sets share the generator with training, we treat this check as diagnostic only and rely on real external sites for the headline claims.

The third check is the error analysis by curve type: whether gains concentrate in plateau-type lesions and in the hard-case Dice10 metric. If gains appear only in easy washout lesions, re-timing is not addressing the ambiguity that readers struggle with.