Measuring Where Experts Disagree, Cheaply, to Make Segmentation Travel

When radiologists outline a tumor or a lymph-node region on a low-contrast scan, they agree about the interior and disagree about the edge. Standard practice discards that disagreement. Several experts draw full contours, the contours are merged by voting or by an expectation-maximization estimator, and the network is trained to reproduce one sharp line. We propose to keep the disagreement and to pay for it cheaply. One expert draws a full contour. A few other experts each place a handful of clicks where they would put the boundary. From the spread of those clicks we estimate, at every point along the contour, how wide the band of genuine ambiguity is. The network is then trained on a soft target whose sharpness follows that band: sharp where experts agree, soft where they do not.

Our hypothesis is about generalization across hospitals. A network trained to reproduce a sharp line through an ambiguous band must learn some local intensity threshold to place that line, and intensity thresholds are exactly what change between scanners and protocols. If the network is not penalized for hedging where humans hedge, it should rely less on these site-specific cues and lose less accuracy at unseen centers. The practical claim is that a few expert clicks recover most of the benefit of multi-expert dense contours at a small fraction of their cost. That claim ties together consensus ground truth, boundary ambiguity, cross-site transfer, and the annotation bottleneck.

Core Claim

Our claim concerns training under leave-one-center-out evaluation, where a model is trained on all centers but one and tested on the held-out one. We claim that supervising a segmentation network with a spatially varying soft boundary, whose local width is estimated from sparse boundary clicks by additional experts, shrinks the internal-to-external performance gap more than three alternatives: hard consensus labels, fixed-width soft boundaries, and single-expert labels. The gain should appear mainly in boundary metrics. We further claim that click-derived widths match the external-site benefit of soft labels built from full multi-expert contours, while costing on the order of seconds per extra expert per structure instead of minutes.

Two things are new. The first is the annotation protocol: sparse multi-expert boundary clicks, rather than multi-expert dense masks, used to measure local disagreement. The second is the test of whether real, spatially varying disagreement acts as a cross-institution regularizer. The closest work is Incorporating Boundary Uncertainty into loss functions for biomedical image segmentation. That paper builds a soft boundary zone by eroding and dilating a single mask with a fixed kernel, and it reports a small in-domain gain on DRIVE (Dice similarity coefficient, DSC, 0.8141 against 0.8082 for Dice loss). Its band has uniform width and is not derived from humans, and it was never tested across sites. Our method replaces the fixed kernel with a width measured from experts and makes cross-site transfer the target.

What prior work establishes and leaves open

Prior work on consensus supplies the motivation. The left-atrial scar challenge, Evaluation of current algorithms for segmentation of scar tissue from late Gadolinium enhancement cardiovascular magnetic resonance of the left atrium, fuses three observers with STAPLE (an algorithm that jointly estimates a hidden true mask and each rater's reliability) across seven centers. It finds median DSC of 72–85 on dense post-ablation scar but only 17–48 on diffuse pre-ablation fibrosis. The fused label is hard, so the reader cannot tell whether low scores reflect model error or legitimate ambiguity. Automatic deep learning-based pleural effusion segmentation in lung ultrasound images shows that a network trained on two-expert consensus reaches 0.70 DSC against consensus, although the two experts agree with each other at only 0.61. The model does this by retreating to high-agreement regions. This result is evidence that disagreement is spatially concentrated and learnable, but it comes from a single site and requires dense contours from both experts.

The multi-center datasets constrain the design. A multicenter dataset for lymph node clinical target volume delineation of nasopharyngeal carcinoma (LNCTVSeg) and The impact of multicentric datasets for the automated tumor delineation in primary prostate cancer using convolutional neural networks on 18F-PSMA-1007 PET both show that plain nnU-Net, a self-configuring U-Net pipeline, already transfers reasonably across centers when trained on multi-center consensus labels. Any gain we claim must therefore be measured against nnU-Net in a leave-one-center-out design, not against a weak baseline. Both datasets release consensus contours and discard individual expert contours, which is precisely the information we want to use. NLSTseg documents the failure we are targeting: a U-Net drops from 0.95 IoU on its training set to 0.42 on its test set, confusing small low-contrast nodules with vessels. That drop is between training and test subjects, not between institutions, so it motivates attention to boundaries but not the cross-site mechanism specifically.

Work on weak supervision supplies part of the method and a warning. Learning to Segment Medical Images with Scribble-Supervision Alone and Scribble-based Domain Adaptation via Co-segmentation show that sparse annotations can nearly match dense ones: 88.0% against 91.2% on ACDC cardiac MRI, and 83.4% against 81.6% for target-supervised training on vestibular schwannoma MRI. Both rely on a single annotator. Weakly Supervised Lesion Co-Segmentation on Ct Scans reports that pseudo-masks grown from sparse seeds by GrabCut bleed into low-contrast tissue. We therefore do not propagate clicks by image appearance. The clicks only set the width of the band around a dense contour that an expert has already drawn, so no region growing ever crosses a weak edge.

Research Program

The pipeline has three pieces.

The first is an annotation protocol. A reference expert draws the usual dense contour. Each of $K$ additional experts, with $K$ between 2 and 4, places about 8–16 clicks on the boundary as they perceive it, preferentially where they would move the reference line.

The second is a width estimator. For each click we compute its signed distance to the reference contour. We then smooth these distances along the contour, using the arc-length parameter $s$ and a one-dimensional Gaussian-process smoother, to obtain a local ambiguity width $w(s)$ with a small floor $w_0$ so that agreed-upon edges stay sharp.

The third is the soft target. Each voxel at signed distance $d$ from the reference contour (negative inside), whose nearest contour point is $s$, receives the target probability

$$ p(d, s) = \sigma\!\left(-\frac{d - \mu(s)}{w(s)}\right), $$

where $\sigma$ is the logistic function and $\mu(s)$ is the smoothed mean click offset. The offset $\mu(s)$ lets the consensus boundary shift away from the reference expert's personal style instead of only blurring around it. The network is standard nnU-Net trained with soft Dice plus binary cross-entropy against $p$. The architecture is deliberately left unchanged so that any effect can be attributed to the supervision.

The analysis program asks three questions. First, does soft supervision derived from real disagreement reduce the drop in accuracy at held-out centers? Second, is the reduction concentrated in the ambiguous band, which we test by stratifying errors by the local agreement of held-out experts? Third, does the model's own predicted boundary softness at a new center track the disagreement of experts who annotated there, even though no labels from that center were used in training? The third question tests whether the model has learned where ambiguity lies, as opposed to merely being smoother.

We also need data. The protocol is simulated wherever individual expert contours exist: clicks are sampled from each expert's contour, with a bias toward points far from the reference. It is then validated with a small prospective collection that measures real click time and real click noise.

Baselines

The naive reference point is nnU-Net trained on single-expert hard labels, the reference expert's contour alone, under the same leave-one-center-out splits. It shows what the additional clicks buy.

The strongest existing competitor is nnU-Net trained on hard multi-expert consensus, meaning the dataset's released consensus or STAPLE over individual contours. This is what LNCTVSeg and the prostate PET study use. The file reports 85.8% internal and 83.0–85.0% external DSC on LNCTVSeg for nnU-Net with mixup (LNCTVSeg). It reports a median DSC of 0.74 under leave-one-center-out and 0.76 under mixed cross-validation for the prostate PET cohort (Holzschuh et al.). For cDEMRIS it reports the median DSC ranges given above for non-deep-learning challenge entries. These are reference points only: we will re-run hard-consensus nnU-Net ourselves on identical splits, because our splits differ from the published ones. We will use the same number of epochs, the same augmentation (including mixup where the original used it), and the same seeds.

The costly upper reference is nnU-Net trained on the voxelwise average of all experts' dense contours. This is the full-price version of soft consensus. It tells us how much of the soft-label effect the clicks recover.

The fixed-width soft band of Yeung et al. and plain label smoothing are tuned on the internal validation fold with the same search budget as our floor $w_0$ and smoother bandwidth. We give each of them roughly twenty configurations.

Two ablations isolate the key ingredient. The first keeps our click-derived widths but shuffles them among contour locations and among patients, preserving the average softness while destroying its spatial alignment with real disagreement. The second sets the offset $\mu(s)$ to zero.

Beating the strongest baseline means a statistically significant improvement over hard-consensus nnU-Net at held-out centers, tested with a paired per-patient Wilcoxon test pooled over folds. The improvement must hold on the 95th-percentile Hausdorff distance (HD95) and on a band-aware score. That score is the fraction of predicted boundary lying inside the envelope spanned by held-out experts' contours, following the idea that a prediction inside the range of human opinion should not be penalized. External DSC must not decrease. Beating the shuffled-width ablation is what licenses the mechanistic claim.

Why not just…?

Why not just average the full expert contours into soft labels? If individual dense contours already exist, this is the obvious approach, and we include it as an upper reference. The problem is cost. LNCTVSeg needed six experts across its boards to produce dense contours (LNCTVSeg), and the file lists this bottleneck as its main limitation. The real question is whether clicks can stand in for full contours, and the gap between our method and full averaging answers it directly. If averaging itself gives no external-site gain over hard consensus, the premise fails, and we would report that as the main finding.

Why not just use a fixed-width soft boundary or label smoothing? This is the most serious threat. If uniform softness regularizes as well as measured softness, experts are unnecessary. Yeung et al. found only a small in-domain margin for the fixed band, and nobody has compared the two across sites. The shuffled-width ablation settles this. If shuffled widths perform as well as aligned widths at held-out centers, we would drop the claim that disagreement structure matters and report a cheaper result: calibrated blur suffices.

Why not just rely on multi-center nnU-Net with heavy augmentation? On LNCTVSeg this already keeps external DSC within about three points of internal DSC. The remaining headroom may therefore be small and concentrated at boundaries, which is why HD95 and the band-aware score are our primary metrics rather than DSC. Our method adds nothing to nnU-Net except the target, so it is not a competing architecture and the comparison is exact.

Why not just fix boundaries at test time with dropout uncertainty? Martinez et al. flip high-uncertainty foreground voxels after training, using Monte Carlo dropout uncertainty, and correct over-segmentation under domain shift. Their evidence comes from materials-science CT, not patient cohorts. We run this procedure on the hard-consensus model as an additional baseline. It removes over-segmentation but cannot move a boundary outward, so it should reduce leakage without improving under-segmented low-contrast edges. Signed boundary error will show whether that happens.

Proposed Experiments

The primary testbed is LNCTVSeg: 440 CT scans from four centers with blurry lymph-node boundaries, evaluated with leave-one-center-out over the four centers. Its released labels are board consensus, and each board covers a different cohort. We will therefore collect individual dense contours from three additional experts on about 40 scans per center. These contours serve two purposes: they supply simulated clicks for training scans, and they supply held-out expert envelopes for evaluation. The prospective part of the same collection records real click time against contouring time.

The secondary testbed is cDEMRIS: 60 scans from seven centers with three individual observers fused by STAPLE. If the individual segmentations are available in the open release, which we will confirm, it gives a naturally multi-expert, multi-center check on thin, low-contrast structures, although with small folds and wide confidence intervals. The NPC MRI dataset of Mei et al. comes from a single center but has a 30-patient two-reader subset with inter-reader DSC around 0.9. It serves as a control where disagreement is low. There we predict no gain, and a gain would suggest the effect is ordinary regularization rather than ambiguity modeling.

We will also run a dose-response experiment, varying the number of extra experts $K$ from 1 to 4 and clicks per expert from 4 to 32. It traces how much of the full-average benefit clicks recover per second of expert time.

The decisive checks are three. First, aligned click-derived widths must beat shuffled widths on held-out-center HD95 and band-aware score; otherwise the mechanism is only blur. Second, the reduction in the internal-to-external gap must be concentrated in voxels where held-out experts disagree. Third, at an unseen center, the model's predicted boundary softness should correlate positively with the local spread among that center's experts. If all three hold, sparse multi-expert clicks are a practical way to turn consensus from an expensive cleaning step into a cheap regularizer against site shift. If only the first fails, the useful conclusion is that a well-tuned uniform soft boundary is enough and multi-expert effort is better spent elsewhere.