A retinal photograph is increasingly treated as a window onto brain blood vessels. Deep models trained on fundus images now flag silent brain infarcts (small strokes that cause no symptoms) and forecast future stroke years ahead. Vessel-width measurements extracted from the same images serve as markers of long-term vascular damage. All of this treats the photograph as a snapshot of stable anatomy. Retinal arterioles, however, are living vessels. Their width and fill change within seconds with heartbeat phase, breathing, and the sympathetic "fight-or-flight" tone of the person sitting at the camera, and a clinic visit reliably raises that tone. If part of what the models read as chronic damage is really the patient's momentary state, then the early, low-amplitude signals that asymptomatic screening depends on are being blurred by noise that nobody measures.
We propose to measure that state, without touching the patient and without any expert labels, and to remove it from retinal features before they are used for risk prediction. A small RGB and thermal camera pair mounted on the fundus camera and facing the patient's face records pulse, breathing, and nasal-tip skin temperature while the patient sits in the chin rest. Nasal-tip cooling is a known readout of sympathetic vasoconstriction. We then learn how retinal features shift with these state variables, using only repeated photographs of the same eye taken minutes apart. The training signal is free: anatomy cannot change in five minutes, so any change in the features between those photographs is nuisance. The core claim is that correcting retinal features for the state measured at capture will substantially improve their test–retest reliability, and through that their association with subclinical cerebrovascular disease, at no annotation cost.
Where this sits in prior work
Three strands motivate the proposal. Retinal foundation models show that the retina carries systemic and cerebrovascular risk. RETFound pre-trains a masked autoencoder on 1.6 million retinal images and reaches AUROC 0.794 (color fundus) for 3-year heart failure. DeepRETStroke detects MRI-confirmed silent brain infarction with AUC 0.797, against 0.633 for clinical traits. AutoMorph automates vessel caliber, tortuosity and fractal dimension, with intraclass correlation above 0.9 against expert tracings. All three treat each image as a fixed readout of anatomy. None records the physiological state under which the image was taken. AutoMorph's reported ICC measures agreement between the software and human graders on the same image, not agreement across repeat captures, so it says nothing about state-driven variation.
The second strand shows that the relevant state can be read from the face without contact. Facial thermography tracks sympathetic vasoconstriction at the nose tip, and remote photoplethysmography (rPPG) recovers the pulse wave from subtle skin-color changes in ordinary video. pyMMER combines the two and reports a 0.86 correlation between rPPG and ECG, plus better stress detection from fused signals than from either alone. Kossack et al. use local rPPG to map tissue perfusion. Vance et al. and Semi-rPPG make rPPG robust across datasets with few labels. These papers supply the sensing methods we reuse. They also warn about occlusion (here the chin rest and the camera body), about thermal lag relative to heartbeat changes, and about rPPG models that memorize the training heart-rate distribution.
The third strand concerns how to learn without experts. The label-efficient literature, including self-learning cyst segmentation, which improves on its teacher but regresses when bootstrapping runs one generation too many, pushes us away from pseudo-label loops. It points toward a signal that cannot drift, and within-person repeat captures provide one. Jonell et al. come closest in spirit: they correlate head-temperature fluctuation with hippocampal volume in 25 memory-clinic patients. They use thermal state as a biomarker, whereas we use it as a measured nuisance that sharpens a separate structural biomarker.
The research file's obvious synthesis would fuse facial vital signs with fundus images as extra inputs to a stroke classifier, or distill a retinal teacher into a facial-video student. We do neither. Fusion needs outcome labels to learn anything and would compete with a blood-pressure cuff. Distillation assumes that faces carry retinal anatomy, which no evidence in the file supports.
Core Claim
Let $f(x)$ be a retinal feature vector computed from photograph $x$. It could be AutoMorph caliber measures such as central retinal arteriolar and venular equivalents (CRAE, CRVE) and their ratio, or a RETFound or DeepRETStroke embedding and risk score. Let $s$ be the state vector measured without contact during the two seconds before the flash: heart rate, cardiac phase at the flash from rPPG, respiratory phase from nostril temperature, and the slope of nasal-tip temperature. We model $f(x) = a_{\text{eye}} + h(s) + \varepsilon$, where $a_{\text{eye}}$ is the stable anatomy of that eye and $\varepsilon$ is residual noise. For pairs $(i, j)$ of photographs of the same eye in the same session, the anatomy cancels. We fit
$$ \min_h \sum_{(i,j)} \big\| \big(f(x_i) - f(x_j)\big) - \big(h(s_i) - h(s_j)\big) \big\|^2 , $$
and use $f(x) - h(s)$ as the corrected feature. Because $h$ sees only the state and never the image, it cannot absorb person identity or disease. It can only remove variation that tracks measured physiology. This built-in guard against erasing signal is why the method needs no labels. The simplest version is linear $h$, which amounts to a within-subject mixed model. The richer version is a small nonlinear network with cardiac phase encoded periodically.
The quantitative expectation follows from classical measurement theory. If state explains a fraction $\rho$ of within-session feature variance, removing it raises test–retest ICC accordingly. Attenuation of a biomarker–outcome association scales with the square root of reliability, so gains in association strength should be modest but systematic. The claim is worth pursuing only if $\rho$ is substantial, and we treat that as the first go/no-go test.
Research Program
We would build a capture rig in which a synchronized RGB camera and a long-wave thermal camera attach below the fundus camera lens housing. They view forehead, cheeks and nose tip, the regions that remain visible with the chin in the rest. rPPG uses the plane-orthogonal-to-skin method on forehead and cheek regions, following the local-rPPG approach of Kossack et al.. It is trained with the speed and modulation augmentations of Vance et al. to avoid heart-rate memorization. Thermal regions follow the region layout of pyMMER. The flash contaminates video frames, so state is always taken from the window before the flash.
The data collection protocol widens state variation on purpose so that $h$ is identifiable. Each participant gives three photographs per eye at rest. They then give three more after a mild sympathetic challenge (a brief cold-pressor hand immersion) and three during paced slow breathing, all within about fifteen minutes. A subset returns after one to two weeks, which lets us check that the correction generalizes across visits and not only within a session. All participants also wear a finger PPG and an automated blood-pressure cuff. These serve as reference sensors and as a competing arm, not as inputs to the proposed method.
For the target population, we would recruit adults aged 55 and over from an eye-screening or stroke-prevention clinic. This is the setting in which DeepRETStroke reports silent infarction in roughly one in five older people. A funded subset receives brain MRI for silent brain infarction and white-matter change. Those labels are used only for evaluation, never for fitting $h$. A realistic first cohort is about 400 participants, of whom about 150 receive MRI. The MRI subset will be too small for a definitive AUC comparison, and we say so now. Its role is to test direction and size of effect, not to claim clinical superiority.
No public dataset in the research file pairs fundus images with facial video, so this cohort is a necessary new resource. The rPPG and thermal components are validated first on existing benchmarks (UBFC-rPPG, PURE, VIPL-HR), so that sensing error is known before it enters the retinal analysis.
Baselines
The naive reference is the uncorrected feature from a single photograph: AutoMorph calibers or RETFound/DeepRETStroke scores computed exactly as their authors release them. Every corrected variant is compared on the same images with identical preprocessing and quality grading. AutoMorph's quality grader is applied first, so that correction is not confused with image-quality filtering.
The strongest practical competitor is multi-capture averaging: take the mean feature over all photographs of an eye in the session, with no state information. It uses the same images and needs no extra hardware. To beat it, the state-corrected single photograph must match or exceed the ICC of the three-photograph average. In addition, the corrected average must beat the plain average in its association with MRI findings. Averaging removes random noise but not state that is shared across the whole session, such as white-coat arousal.
The strongest existing predictive systems are DeepRETStroke for silent brain infarction and RETFound as a general embedding. For DeepRETStroke, the published figure is an AUC of 0.797 for silent brain infarction detection and 0.633 for clinical traits alone (DeepRETStroke). We do not expect to reproduce 0.797 on a new cohort and camera, given the domain shift that paper itself flags. The fair comparison is therefore the same frozen model, uncorrected versus corrected, on our MRI subset, with bootstrap confidence intervals. For RETFound, no reported result was found on Lacuna for silent brain infarction or retinal caliber reliability. We run it frozen with a linear probe fitted under identical cross-validation folds and an identical tuning budget for all arms.
The contact-sensor arm replaces the non-contact state $s$ with finger-PPG heart rate, pulse phase, pulse amplitude, and cuff blood pressure. It is fitted with exactly the same objective. This is the ablation that decides whether the non-contact cameras add anything beyond "measure state at capture." Two further ablations isolate the ingredients: cardiac phase only versus the full state vector, and the thermal channel removed.
For the sensing components, the reference numbers from the file are an rPPG cross-dataset MAE of 2.25 BPM on PURE-to-UBFC (Vance et al.) and a VIPL-HR RMSE of 10.99 BPM with 20% labels (Semi-rPPG). Our chin-rest rPPG must land near these values against finger PPG to be trusted.
Why not just…?
Why not just take several photographs and average them? This is the most serious threat, because clinics can do it today. Averaging shrinks random error by roughly the square root of the number of photographs. It does nothing, though, for state that persists through the session, and such state is plausibly correlated with the very groups at risk: anxious or hypertensive patients are aroused throughout their visit. The cold-pressor and paced-breathing blocks let us test this directly. If averaging within each block already equalizes features across blocks, state correction is unnecessary and we will report that. If block means still differ and correction closes the gap, averaging is insufficient.
Why not just clip a pulse oximeter on the finger and take a blood pressure reading? This may work just as well for cardiac phase and heart rate, and the contact arm is designed to show it. The non-contact rig has two potential advantages. The thermal nasal-tip channel reads sympathetic vasoconstriction in a facial vascular bed that is arguably closer to the ocular circulation than the finger. And the rig adds no attachment step to a high-throughput screening workflow. If the contact arm matches the non-contact arm on reliability and MRI association, the scientific claim still stands ("state at capture matters"), but the case for cameras reduces to workflow. We will state that plainly and not argue around it.
Why not just add the facial signals, or clinical covariates, as extra inputs to a stroke-risk classifier? Fusion learns how to use state only from outcome labels. Outcomes such as MRI-confirmed silent infarction are exactly the expensive expert annotations we lack. With 150 labels, a fused model would mostly overfit. The correction learns from within-person repeats, which are unlimited and free, and then leaves the downstream risk model untouched. For completeness, the fused model is run as a comparison arm on the same folds.
Why not just fine-tune the retinal foundation model with more MRI labels? This would help, but it attacks the annotation bottleneck by paying for it. RETFound already shows that its features are label-efficient, and our correction is complementary: it can be applied on top of any fine-tuned model. We test whether corrected frozen features plus a linear probe close part of the gap to a fine-tuned model at equal label count.
Proposed Experiments
The first check is a pure measurement study and serves as go/no-go. Within session, how much of the variance of CRAE, CRVE, the arteriole-to-venule ratio, and foundation-model risk scores is explained by the measured state? We prespecify that the programme continues only if state explains at least 10% of within-session variance for either the caliber measures or the risk scores, and if that fraction holds on held-out participants. Below that threshold, retinal snapshots are stable enough that the problem does not exist, which is itself a useful negative result for oculomics.
The second check is reliability. We compare test–retest ICC of single-photograph features, uncorrected versus corrected, within session and across the one-to-two-week revisit, alongside the averaging and contact-sensor arms. The key comparison is whether the correction learned in-session transfers to the revisit. If it does not, $h$ is fitting session artifacts, not physiology.
The third check is association with subclinical disease in the MRI subset. We compare AUC for silent brain infarction and correlation with white-matter burden for corrected versus uncorrected DeepRETStroke-style scores and AutoMorph calibers, with clinical traits as the floor. We report bootstrap intervals and treat the result as an effect-size estimate, not a definitive clinical claim.
The fourth check is a fairness audit. Chin-rest occlusion, skin tone and facial hair degrade rPPG, as pyMMER notes. We therefore report sensing error and correction benefit stratified by these factors, and we fall back to thermal-only state when rPPG quality falls below a signal-to-noise threshold.
The result that would most clearly validate the idea combines three findings: corrected single photographs match or beat three-photograph averages in revisit ICC, the benefit survives in the challenge blocks where averaging fails, and the non-contact arm is at least as good as the contact arm. The result that would most clearly refute it is state explaining little variance, or the correction helping reliability while leaving the MRI association unchanged.
References
- A foundation model for generalizable disease detection from retinal images
- A deep learning system for detecting silent brain infarction and predicting stroke risk
- AutoMorph: Automated Retinal Vascular Morphology Quantification Via a Deep Learning Pipeline
- Your blush gives you away: detecting hidden mental states with remote photoplethysmography and thermal imaging
- Perfusion assessment via local remote photoplethysmography (rPPG)
- Promoting Generalization in Cross-Dataset Remote Photoplethysmography
- Semi-rPPG: Semi-Supervised Remote Physiological Measurement With Curriculum Pseudo-Labeling
- Self-learning to detect and segment cysts in lung CT images without manual annotation
- Multimodal Capture of Patient Behaviour for Improved Detection of Early Dementia: Clinical Feasibility and Preliminary Results