Fast MRI scans record only a fraction of the raw frequency-space measurements (called "k-space"), and a reconstruction network fills in the rest. A scanner never measures a patient only once, in a sense: the acquired measurements can be split into two disjoint halves, and each half is itself a valid, physically real undersampled scan of the same heart. We propose training a cardiac segmentation model from a handful of cheap scribble annotations plus many unlabeled raw scans. The model is required to produce the same contours whether it sees the full acquisition or either half. The reconstruction network contains a data consistency layer, a fixed step that forces the image to agree exactly with whatever measurements were acquired. Because of that layer, the two views differ only in what the network had to guess, never in what the scanner actually recorded. Disagreement between the views is therefore a physically honest training signal. It needs no expert labels, can be computed on unlabeled scans from a new site, and targets the corruptions the model will meet at deployment: aliasing, noise and missing frequencies. Standard training instead uses invented perturbations such as gamma curves or rotations.
This matters because the four constraints are usually attacked one at a time. Scribble methods assume clean reconstructed images. Physics-based reconstruction assumes fully sampled training data and ignores the downstream task. Domain-shift methods manipulate intensities of already-reconstructed images. A clinic that runs accelerated protocols has abundant unlabeled raw data and almost no expert time. Our method is designed to exploit exactly that asymmetry.
Core Claim
Let $y_\Omega$ be the acquired k-space on index set $\Omega$. Let $R_\theta$ be an unrolled reconstruction network whose data consistency layers enforce agreement with whichever measurements it is given, and let $S_\phi$ be a segmenter. For an unlabeled scan we draw a random split $\Omega = \Omega_1 \cup \Omega_2$ and minimize
$$\mathcal{L}_u = \sum_{k=1,2} D\big(S_\phi(R_\theta(y_{\Omega_k})),\ \mathrm{sg}[S_{\bar\phi}(R_{\bar\theta}(y_\Omega))]\big) + \mu \sum_{k=1,2} \big\| P_{\Omega\setminus\Omega_k}\, A\, R_\theta(y_{\Omega_k}) - y_{\Omega\setminus\Omega_k} \big\|^2$$
The symbols are as follows:
- $D$ is a soft Dice disagreement.
- $\mathrm{sg}$ stops gradients through a slowly updated teacher copy with weights $(\bar\theta,\bar\phi)$ that sees all acquired data.
- $A$ is the multi-coil forward operator (coil sensitivities followed by Fourier transform).
- $P_{\Omega\setminus\Omega_k}$ keeps only the held-out measurements.
The second term predicts the measurements each half did not see. It trains the reconstructor with no fully sampled data at all. This held-out-k-space trick is known from self-supervised reconstruction but is not indexed in the file. The first term is the new ingredient: it transfers that physical self-supervision to the segmentation task. A small scribble loss on a few labeled subjects completes the objective.
The claim we will test is specific. At clinically aggressive accelerations and under acquisition shift, measurement-split consistency beats two alternatives given identical labels and unlabeled data:
- sequential reconstruct-then-segment pipelines;
- image-space consistency methods.
The advantage should come from the data consistency layer and not merely from seeing aliasing-like perturbations. We also test a secondary claim: the disagreement between splits, computed without labels, predicts when segmentation is failing on a new site.
Relation to Prior Work
The closest joint reconstruction-segmentation work motivates the task coupling but constrains our assumptions. Task adapted reconstruction for inverse problems trains an unrolled reconstructor and a task network under a weighted joint loss. Empirical evidence of the task-adapted reconstruction framework for joint CT reconstruction and segmentation reports that in noisy sparse-view CT the joint model lifts Dice from 0.012 to 0.214. It also reports that reconstruction fidelity and segmentation quality can diverge. Both require dense masks on simulated 2D data, and neither uses unlabeled scans. We keep the coupling but replace dense masks with scribbles plus split consistency.
Label-efficient segmentation supplies the scribble machinery and our strongest image-domain competitors, all operating on reconstructed magnitude images:
- ShapePU treats unlabeled pixels as a positive-unlabeled problem with cutout consistency.
- Learning to Segment Medical Images with Scribble-Supervision Alone expands scribbles with random walks and CRFs.
- Extreme Consistency is the closest in spirit. Its teacher-student design aligns a teacher on mild inputs with a student on aggressive photometric distortions, and it reaches 0.824 Dice with two labeled retinal images.
Our method is structurally a teacher-student method too. The difference is that its perturbation is a real re-acquisition, and a physics constraint guarantees it cannot alter measured content.
Two papers operate in raw measurement space:
- Zero-Shot Domain Adaptation in CT Segmentation by Filtered Back Projection Augmentation shows the value of working there. It raises cross-kernel prediction consistency from 0.54 to 0.92 Dice, while image augmentations fail. It uses a hand-designed filter augmentation on fully labeled data, not a learned consistency on unlabeled data.
- Reconstruction-free segmentation from undersampled k-space using transformers segments directly from k-space at up to 64x acceleration. It needs 1,000 labeled slices and concedes a risk of memorizing canonical heart location. We keep an image and a consistency layer precisely so that the guessed content is confined to what the scanner did not measure, as formalized by range-null decomposition.
Finally, Scale-Equivariant Unrolled Neural Networks supplies a data-efficient reconstructor we can reuse, though it never touches the downstream task.
Research Program
We build one system and three ablated relatives on the CMRxRecon challenge data. This is multi-coil raw k-space from 300 subjects for cine and T1/T2 mapping, with cardiac anatomical annotations. That makes it the only resource in the file combining raw measurements with segmentation labels.
The reconstructor is an E2E-VarNet-style unrolled network, the architecture used by the winning cine entry in that challenge. The segmenter is a 2D nnU-Net-style network. To emulate the annotation bottleneck, we generate synthetic scribbles from the ground-truth masks by skeletonizing a random sub-region of each structure, following the protocols of the scribble papers above. Only 3, 5, 10 or 20 subjects receive scribbles, and the remaining subjects contribute unlabeled k-space only.
The first phase establishes that split consistency trains stably from scribbles. This directly probes the file's open question of whether sparse labels can drive a jointly trained unrolled pipeline without collapse. The second phase measures behavior under acquisition shift. The third phase tests adaptation to a new site with the segmenter frozen, updating only the reconstructor via the unlabeled objective. This mirrors the regulatory setting in which a validated diagnostic model cannot be retrained, the "adapt the data, not the model" argument of Adapt the Data, Not the Model. Here adaptation is limited to the unmeasured part of the image, so it cannot rewrite measured anatomy.
Baselines
The naive reference is a segmenter trained with scribbles only, on images from a fixed reconstructor, with no unlabeled data. This tells us how much any use of unlabeled data buys.
The main competitor is the sequential pipeline. E2E-VarNet is trained on the same data with the same held-out-k-space self-supervision, frozen, and followed by ShapePU trained on the reconstructed images. ShapePU uses our scribbles plus all unlabeled reconstructed images through its own consistency loss. It is the strongest competitor because it is the best-reported scribble method in the file: on ACDC it surpasses full supervision by 1.4% average Dice, and on MSCMRseg it reaches 85.2%. The reconstruction half is the strongest reported reconstructor, at SSIM 0.990±0.002 for cine according to the CMRxRecon paper. There is no reported result on Lacuna for scribble-supervised segmentation on CMRxRecon, so these figures are context from other cohorts, and every method will be rerun by us.
The second competitor is Extreme Consistency applied to reconstructed images with its photometric and patch-mixing perturbations. On ACDC, the semi-supervised reference points are Mean Teacher at 0.654 and multi-constraint self-training at 0.730 DSC with 5% labels, per A Semi-Supervised Framework for Cardiac MRI Segmentation via Multi-Constraint Collaborative Self-Training. We will include Mean Teacher as well.
Two ablations isolate the key ingredients:
- Removing the consistency layer. The same split-consistency objective is used, but the reconstructor is a plain U-Net on zero-filled inputs with no consistency layer. This tests whether the physics anchor matters.
- Moving the split into image space. The same objective is used, but both views are produced by simulating undersampling artifacts on already-reconstructed magnitude images. This tests whether real multi-coil raw data matters or whether aliasing-style augmentation alone suffices.
Fairness is enforced in three ways. All methods get identical labeled and unlabeled subjects, the same segmenter backbone, the same GPU budget, and an equal number of hyperparameter trials (twenty) tuned on a labeled validation split of five subjects. Results are reported over five label draws. Beating the sequential pipeline means a mean Dice gain whose confidence interval over the five draws excludes zero, at 8x acceleration or above or under shift. A smaller gain at 4x would be acceptable, and so would a tie.
Why not just…?
Why not just reconstruct with E2E-VarNet and then run ShapePU? This is the real threat. At modest acceleration, reconstructions near SSIM 0.99 may leave nothing for joint training to recover. The file's strongest evidence against sequential pipelines comes from other settings: the 0.012 versus 0.214 Dice result is from extreme noisy sparse-view CT, and the DiSK image baselines degraded at high acceleration. Neither result transfers automatically to multi-coil cardiac MRI. We therefore sweep acceleration from 4x to 24x and predict that the gap opens only as aliasing grows and under shift. If it never opens, the honest conclusion is that sequential pipelines suffice for cardiac MRI, and the value of our method reduces to the label-free failure signal.
Why not just use heavy intensity augmentation, which cut the vendor gap in M&Ms from 6% to 1.5%? The finding from the M&Ms Challenge concerns contrast and intensity differences between cleanly reconstructed images. Intensity jitter cannot reproduce structured aliasing, and the FBP-augmentation study found image augmentations failed where raw-space operations succeeded. We will nonetheless give every baseline the M&Ms-winning intensity augmentations. Under the shift in which only image contrast changes, from cine to mapping, we expect augmentation to capture most of the benefit, and we will report that plainly.
Why not just segment directly from k-space, skipping reconstruction? DiSK's 0.902 Dice was obtained with 1,000 labeled slices from one homogeneous cohort. Its own authors flag memorization of canonical heart position as a failure mode, and its output gives a radiologist no image to check. We will train DiSK with our same scribble budget, plus the split-consistency loss, which applies to it unchanged. If it matches our method at 5 labeled subjects, the consistency layer is not earning its cost.
Proposed Experiments
The in-distribution experiment trains and tests on CMRxRecon cine at 4x, 8x, 12x and 24x retrospective acceleration. For each of 3, 5, 10 and 20 scribble-labeled subjects, we report per-structure Dice and 95th-percentile Hausdorff distance. These metrics match those used for UK Biobank k-space segmentation.
The shift experiments change one acquisition factor at test time while keeping patients disjoint:
- sampling pattern and acceleration unseen in training;
- a reduced receive-coil set, emulating different coil hardware;
- simulated field-inhomogeneity and in-plane motion perturbations, which make the assumed forward operator wrong;
- cine-to-mapping contrast, if the mapping annotations are sufficient.
For vendor shift we have no multi-vendor raw k-space in the file. We will therefore run a weaker check on M&Ms, with Siemens and Philips as source and Canon as the unseen target, using k-space synthesized from DICOM images with simulated coils. This synthesized data already contains vendor post-processing, so the experiment only tests whether re-reconstructing through a shared network harmonizes residual differences. We state this limitation rather than claim true vendor robustness.
The decisive checks are three.
First, at 8x or above with 5 labeled subjects, measurement-split consistency must beat the image-space-split ablation. If it does not, real raw data is unnecessary and the idea reduces to augmentation.
Second, it must beat the no-consistency-layer ablation, especially under the motion and field-inhomogeneity shift. There is a competing risk here that the file flags: enforcing agreement with a wrong forward operator can create structured artifacts. So we also measure whether our gain shrinks or reverses as operator mismatch grows.
Third, on shifted test sets, per-scan disagreement between split views must rank-correlate with per-scan Dice loss, with Spearman correlation reported and compared against Monte Carlo dropout uncertainty on the same scans. A strong correlation would give deployment sites a label-free alarm that tells them when to call in an expert, whatever the segmentation gains.
References
- Task adapted reconstruction for inverse problems
- Empirical evidence of the task-adapted reconstruction framework for joint CT reconstruction and segmentation
- ShapePU: A New PU Learning Framework Regularized by Global Consistency for Scribble Supervised Cardiac Segmentation
- Learning to Segment Medical Images with Scribble-Supervision Alone
- Extreme Consistency: Overcoming Annotation Scarcity and Domain Shifts
- Zero-Shot Domain Adaptation in CT Segmentation by Filtered Back Projection Augmentation
- Reconstruction-free segmentation from undersampled k-space using transformers
- Null Space Matters: Range-Null Decomposition for Consistent Multi-Contrast MRI Reconstruction
- Scale-Equivariant Unrolled Neural Networks for Data-Efficient Accelerated MRI Reconstruction
- The state-of-the-art in cardiac MRI reconstruction: Results of the CMRxRecon challenge in MICCAI 2023
- Adapt the Data, Not the Model: Input-Space Adaptation for Frozen Time-Series Predictors
- A Semi-Supervised Framework for Cardiac MRI Segmentation via Multi-Constraint Collaborative Self-Training
- Multi-Centre, Multi-Vendor and Multi-Disease Cardiac Segmentation: The M&Ms Challenge