Measurement-First Hematoma Expansion Prediction from Weak Labels

When a patient arrives with a brain bleed, intracerebral hemorrhage (ICH), the most urgent question is whether the blood clot (hematoma) will keep growing over the next day. Clinicians judge this risk by looking at the clot's shape on a non-contrast CT scan. They check whether it is irregular, whether a blood-fluid layer has formed, how large it is, and which way it extends. Deep networks trained end to end on raw CT now beat clinical scores at this prediction, but they are black boxes trained on one or two hospitals. Two things block their use in practice: they cannot say which measurement drives a prediction, and they tend to latch onto quirks of the scanner or hospital.

We propose to force the predictor to go through a small set of physically defined clot measurements, and only those. The measurements are volume, the three principal axis lengths, surface regularity, attenuation heterogeneity, and a fluid-level indicator. They are computed from a 3D clot mask, and that mask is learned only from the rough diameter lines clinicians already draw when they estimate clot volume, plus a few sparse scribbles. The segmenter is trained to get the measurements right and stable under changes in how the scan was acquired, not to maximize pixel overlap. The bet is that a predictor which can only see measurements a neurologist would recognize loses less accuracy when moved to a new hospital than a raw-image network, while needing no dense manual contours.

Core Claim

The claim has two linked parts. First, a "geometric concept bottleneck" generalizes across institutions better than an end-to-end image model on 3D CT. This is a prediction head that sees only a fixed vector of named morphological measurements. Second, the bottleneck can be fed by masks learned from routine clinical marks, provided the segmenter is trained against measurement-level targets and measurement-level invariance rather than voxel Dice.

The second part matters because the evidence linking geometry to expansion and outcome rests on heavy semi-automated 3D segmentation. The Patterns of Morphological Change During Intracerebral Hemorrhage Expansion segmented paired scans for 1,094 patients across four centers to show that lateral growth raises the odds of poor discharge outcome (OR 1.139 per mm). Comparing Handcrafted Radiomics Versus Latent Deep Learning Features required 3D hematoma masks for all 1,511 patients in ATACH-2 and Yale. A method that cannot drop that cost will not travel to new sites.

Why This Combination, and What Already Exists

Three bodies of work motivate the idea.

The first shows that morphology carries the signal. Differential Risk Factors for Hematoma Expansion in Deep and Lobar Intracerebral Hemorrhage found that fluid level predicts expansion in deep bleeds (OR 4.77) and irregular shape predicts it in lobar bleeds (OR 4.96). The two locations have non-overlapping predictors. This constrains our design: the bottleneck head must be conditioned on bleed location rather than applying one universal geometric rule.

The second shows that routing predictions through clinical concepts reduces shortcut learning, but only with language concepts on 2D images. A Textbook Remedy for Domain Shifts (KnoBo) retrieves textbook concepts and reports a 32.4% average out-of-distribution gain over fine-tuned Vision Transformers. Robust and Interpretable Medical Image Classifiers via Concept Bottleneck Models uses GPT-4 concepts projected through a vision-language model. Our concepts are instead computed quantities with physical units, read off a 3D mask, so no vision-language alignment is needed. Diagnosing as Cardiologists Do (LuminaECG) is the closest analogue in spirit: grounding ECG reading in clinician measurement primitives kept performance stable across countries. We test whether the same holds for 3D cross-sectional imaging.

The third supplies the label-efficient machinery. Weakly Supervised Lesion Co-Segmentation on CT Scans turns routine RECIST diameter lines into pseudo-masks (90.3% Dice on DeepLesion, 2D only). Learning to Segment Medical Images with Scribble-Supervision Alone stays within a few Dice points of full supervision. Two papers set limits on this machinery. Self-Learning to Detect and Segment Cysts in Lung CT Images shows that self-training peaks and then degrades as pseudo-label errors compound; we therefore cap self-training rounds. Rethinking Generalization: The Impact of Annotation Style shows that multi-site segmentation drops are largely driven by differences in how each site's raters draw.

The last finding cuts both ways for us. Weak labels drawn by different hospitals may carry their own style shift. We measure this directly rather than assume weak labels are style-free. Rethinking Annotation Granularity shows that spatial supervision beats image-level labels for external generalization (fracture AUC 0.67 vs 0.51), but at a large annotation cost. We ask whether measurement-level supervision buys the same robustness more cheaply.

The obvious combined idea, "weakly supervised segmentation, then radiomics, then a classifier," differs from ours in two ways. Radiomics produces over a thousand texture features, which reopens the door to scanner shortcuts. And the masks it uses are optimized for overlap, not for the accuracy of the few measurements that matter.

Research Program

The system has three parts.

The first is a 3D segmenter trained from weak supervision. Its targets are the diameter lines drawn for bedside volume estimation (the ABC/2 practice, the ICH counterpart of RECIST) and sparse scribbles on a small subset of scans. All downstream measurements are computed differentiably from the soft mask. Volume is the sum of soft voxels. Axis lengths come from the eigenvalues of the second moments of the mask. Surface regularity uses the ratio of soft surface area to the area of a sphere of equal volume. Attenuation heterogeneity is the standard deviation of Hounsfield units (the CT density scale) inside the mask.

The segmenter's loss has three terms:

$$ \mathcal{L} = \mathcal{L}_{\text{line}}(m) + \lambda_s \mathcal{L}_{\text{scrib}}(m) + \lambda_v \sum_k \mathbb{E}_{a}\big[(g_k(m(x)) - g_k(m(a(x))))^2\big] $$

Here $m$ is the soft mask predicted for scan $x$. $\mathcal{L}_{\text{line}}$ penalizes mismatch between the mask's extents and the clinician's drawn diameters. $\mathcal{L}_{\text{scrib}}$ is a partial cross-entropy on scribbled voxels. $g_k$ is the $k$-th morphological measurement. $a$ is a random acquisition perturbation: slice-thickness resampling, a change of reconstruction-kernel-like blur, or a noise level change. The third term is a measurement-level analogue of the repeatability penalty in Learning Repeatable Speech Embeddings Using an Intra-class Correlation Regularizer, which penalized embedding variance across recordings of the same subject. Here we penalize variation in clinically named quantities instead.

The second part is a separate small head that detects the fluid level from a few labeled examples. It is needed because a blood-fluid interface is a horizontal density edge rather than a shape property.

The third part is the predictor itself, a sparse logistic or shallow additive model over the roughly eight measurements plus admission clinical variables, with separate coefficients for deep and lobar bleeds. Its coefficients are directly comparable to the published odds ratios. That comparison is a sanity check that clinicians can audit.

Baselines

The naive reference point is the clinical BRAIN score and a clinical-radiologic model. Noncontrast CT-based Deep Learning for Predicting Intracerebral Hemorrhage Expansion reports external AUCs of 0.658 and 0.690 for these on revised expansion. We recompute both on our splits.

The strongest existing method is the 2D-ResNet-101 from that same paper. It reports an external testing AUC of 0.777 (95% CI 0.716–0.830) for revised hematoma expansion, the strongest published cross-center number in the file. Its outcome definition includes ventricular growth, so we retrain it on our expansion definition. It gets the same training sites, the same augmentation including our acquisition perturbations, and the same hyperparameter search budget as our segmenter. We also train a 3D CNN under the same budget, so the comparison is not confounded by dimensionality.

Several baselines isolate individual ingredients. A Hounsfield-unit threshold mask with the same measurements tests whether learning the mask is needed at all. Radiomics on our weak masks tests whether a narrow, named bottleneck beats a wide one. For ATACH-2 there is no reported result found on Lacuna for exact AUCs, so we produce our own. Two ablations target our key ingredients: the same pipeline without the invariance term, and with Dice-optimized rather than measurement-optimized masks. A bottleneck fed by dense manual masks gives the upper bound for annotation savings.

Beating the strongest baseline means one of two things. Either our external AUC is no lower than the ResNet's while our internal-to-external drop is significantly smaller, or our external AUC is significantly higher. "No lower" means within a pre-registered non-inferiority margin of 0.03. Significance is assessed with DeLong tests and bootstrap confidence intervals.

Why not just…?

Why not just threshold Hounsfield units and skip learning the mask? Fresh blood is bright on CT, so this is a real threat for volume. It is weaker near bone, near intraventricular blood, and at the low-density margins that define irregularity. The thresholded-mask baseline answers this directly. If it matches our learned masks on measurement agreement at external sites, we drop the weak-supervision component and the contribution reduces to the geometric bottleneck alone. We would report that honestly.

Why not just train an end-to-end network on more centers? That is the 0.777 model, and pooling more sites is the standard remedy, as in the multinational COVID-19 CT work (Artificial Intelligence for the Detection of COVID-19 Pneumonia on Chest CT). Counter-evidence exists: Rethinking Annotation Granularity found that adding 179,919 image-level radiographs worsened out-of-distribution performance by reinforcing shortcuts. Pooling also runs into the data-governance barriers noted in Computational Pathology in the Era of Emerging Foundation and Agentic AI. Our injected-confounder experiment shows whether the end-to-end model absorbs site cues that the bottleneck cannot see.

Why not a language concept bottleneck like KnoBo? KnoBo needs paired images and reports, and it aligns concepts through 2D vision-language models. Neither transfers cleanly to 3D head CT. More importantly, "irregular shape" as a text concept carries the reader variability that quantified regularity removes. We include a reduced KnoBo-style variant: text concepts scored by a model fine-tuned on slice-report pairs, where reports exist. If it matches ours, the claim that geometric concepts matter fails.

Why not just annotate dense masks? Dense masks remain the upper bound, and they encode site rater style (Rethinking Generalization). If the dense-mask bottleneck beats ours by more than 0.03 external AUC, the annotation savings are not worth it, and we report the trade-off curve against scribble count.

Proposed Experiments

We train on ATACH-2 (866 patients, multi-center, with expansion labels at the >6 mL threshold) and test externally on the Yale cohort (645). With data-sharing permission, we add the four-center CICHID (1,094) and the Tongji deep/lobar cohort (404) as further held-out sites, using leave-one-site-out evaluation.

We judge the measurements themselves in two ways. The first is the intraclass correlation between measurements from our weak masks and from dense reference masks on a 100-scan annotated subset per site. The second is the agreement of the deep/lobar coefficients with the published odds ratios for fluid level and irregular shape.

Three checks are decisive.

The first tests generalization. The geometric bottleneck's AUC drop from internal to external sites should be smaller than the ResNet's under identical budgets. If it is not, the core claim fails.

The second is a shortcut stress test in the style of the confounded benchmarks behind KnoBo. In the training data we make slice thickness correlate with the expansion label at one site, then evaluate on a site where the correlation is reversed. We expect the end-to-end model to collapse and the bottleneck to hold.

The third is a temporal "silent" split. The model is frozen on earlier admissions and scored on the latest year at each site, mimicking the retrospective-to-prospective decay that DEPLOYR measured on tabular labs (AUROC 0.76 to 0.69, DEPLOYR). This gives the first such decay estimate for a volumetric imaging marker.

Alongside these, we test whether weak diameter lines carry site style. We fit a site classifier on the line-implied measurements alone, and we check whether the invariance term reduces the measurement differences between sites that show up once location and volume are controlled.

References

  1. The Patterns of Morphological Change During Intracerebral Hemorrhage Expansion: A Multicenter Retrospective Cohort Study
  2. Comparing Handcrafted Radiomics Versus Latent Deep Learning Features of Admission Head CT for Hemorrhagic Stroke Outcome Prediction
  3. Differential Risk Factors for Hematoma Expansion in Deep and Lobar Intracerebral Hemorrhage
  4. A Textbook Remedy for Domain Shifts: Knowledge Priors for Medical Image Analysis
  5. Robust and Interpretable Medical Image Classifiers via Concept Bottleneck Models
  6. Diagnosing as Cardiologists Do: ECG Agents with Doctor-Grounded Priors for Clinical Reasoning Across Diseases and Populations
  7. Weakly Supervised Lesion Co-Segmentation on Ct Scans
  8. Learning to Segment Medical Images with Scribble-Supervision Alone
  9. Self-learning to detect and segment cysts in lung CT images without manual annotation
  10. Rethinking Generalization: The Impact of Annotation Style on Medical Image Segmentation
  11. Rethinking annotation granularity for overcoming deep shortcut learning: A retrospective study on chest radiographs
  12. Learning Repeatable Speech Embeddings Using An Intra-class Correlation Regularizer
  13. Noncontrast CT-based deep learning for predicting intracerebral hemorrhage expansion incorporating growth of intraventricular hemorrhage
  14. Artificial intelligence for the detection of COVID-19 pneumonia on chest CT using multinational datasets
  15. Computational Pathology in the Era of Emerging Foundation and Agentic AI -- International Expert Perspectives on Clinical Integration and Translational Readiness
  16. DEPLOYR: a technical framework for deploying custom real-time machine learning models into the electronic medical record