Measured Locality for Splitting Full-Resolution CT Inference Across Workstation GPUs

Hospitals already run 3D neural networks on CT scans to flag fractures, emboli and other findings before a radiologist opens the study. At native resolution these volumes do not fit in one GPU's memory. Deployed pipelines therefore shrink the scan, process 2D slices, or slide a small 3D window across it one patch at a time. Domain decomposition, the numerical-analysis practice of cutting a large physical problem into pieces that are solved separately and stitched back together, offers a principled alternative. It comes with a body of theory about how wide the overlap between pieces must be, and when local pieces need a coarse global solve to stay consistent. This proposal imports that theory as a measurement and design tool rather than as HPC machinery.

The core idea fits in two sentences. First, we measure how quickly a trained 3D segmentation network "forgets" input voxels as they get farther from the output voxel, and use that decay length to choose, with a stated error tolerance, how much padding each independent sub-volume needs. Second, a cheap whole-volume coarse pass supplies the few quantities that do not decay with distance, such as which vertebra is which and the reference heights of neighboring vertebrae. With both pieces, the sub-volumes can run on separate GPUs with no communication between them and still reproduce the full-volume answer.

Core Claim

In electronic-structure theory, Analysis of the divide-and-conquer method for electronic structure calculations proves that the error from cutting a system into buffered subsystems decays exponentially with buffer distance when a spectral gap exists. In gapless systems the decay becomes slow and algebraic. This result motivates our claim. We hypothesize that a trained medical 3D network behaves like a "gapped" system for local outputs such as voxel labels of bone and organ tissue. Its outputs are then nearsighted, and a short, measurable buffer suffices. The same network behaves like a "gapless" system for outputs that depend on long-range structure, such as vertebral level identity, Genant grading relative to adjacent levels, and continuity of thin branching vessels. For those outputs, no affordable buffer fixes the error. Only a coarse global correction does.

The concrete deliverable has two parts. The first is a per-network, per-anatomy locality length ℓ. We measure it from the sensitivity profile

$$s(d) = \mathbb{E}\left[\,\left|\partial y(x) / \partial u(x')\right| \;:\; |x - x'| = d\,\right],$$

where $y(x)$ is the network's output logit at voxel $x$, $u(x')$ is the input intensity at voxel $x'$, and the expectation runs over voxel pairs at distance $d$ in held-out scans. The second part is a buffer rule predicted from it, $\varepsilon(b) \approx C e^{-b/\ell}$. Here $\varepsilon(b)$ is the maximum disagreement between stitched and full-volume outputs when each sub-volume carries a buffer of $b$ voxels, and $C$ is fit on calibration scans. The exponential form is the hypothesis carried over from the gapped case. Part of the test is whether it holds or whether an algebraic fit is better.

Relation to Prior Work

The closest existing work is Machine learning and spatial decomposition for large CT scans.. It splits a single volume across processors in the DistDL extension of PyTorch and exchanges boundary voxels at every convolution layer, so the result exactly matches single-device inference. It reports a 3.4x to 4.2x per-process memory reduction and scaling to more than 4,000 processors. It was tested only on synthetic ellipses, and its authors state that it is best suited to HPC clusters rather than local multi-GPU workstations. We take the opposite design point. We use no per-layer communication, accept a bounded and measured approximation, use real clinical CT, and target one to four GPUs.

Three works supply method rather than motivation:

Two medical-imaging lines constrain the design:

Finally, Segmenting Whole-Body MRI and CT for Multiorgan Anatomic Structure Delineation reports perfect vessel consistency on the aorta but fragmentation and roughly 0.64 Dice on portal and splenic veins. We read thin branching vessels as the anatomical analogue of the gapless regime, where we predict local decomposition will fail.

Research Program

We train standard 3D U-Net style segmenters with nnU-Net's configuration on VerSe 19/20, introduced in A Vertebral Segmentation Dataset with Fracture Grading, and on TotalSegmentator CT and AMOS22. We then proceed in three steps.

The first step is measurement. We compute $s(d)$ separately for each anatomical class: vertebral body, cortical endplate, solid organ, large vessel and small vessel. From these profiles we estimate the locality length ℓ and test exponential against algebraic fits. The reference is full-volume native-resolution inference, run on a large-memory accelerator or on CPU. That reference defines "the right answer" independently of any decomposition.

The second step is the buffer rule. We partition each test volume into $P \in \{2, 4, 8\}$ sub-volumes and give each a buffer $b$ chosen from ℓ to hit a target $\varepsilon$. Sub-volumes run on separate GPUs with no exchange, and we keep only each sub-volume's interior. We test whether the predicted $\varepsilon(b)$ matches the observed stitching error on scans not used for fitting.

The third step is coarse correction for nonlocal quantities. A downsampled whole-volume pass produces vertebral level labels, approximate centroids, and per-level reference heights. These reach the fine solves as an explicit conditioning input, the analogue of an interface transmission condition, rather than only as a crop location. The fine solves then output masks and anterior, middle and posterior height estimates. Genant grade is computed from those heights relative to the coarse references for the adjacent levels. We sweep the coarse-to-fine resolution ratio to trace the accuracy-cost curve. We will test whether a scaling resembling the $H = h^{2/3}$ rule from the Stokes–Darcy work appears, but we do not assume it.

Baselines

The naive reference point is global downsampling. The whole volume is resampled to fit one GPU, segmented, and upsampled. It shows how much fine detail matters for mild Genant grade 1 fractures and small vessels. We beat it if full-resolution decomposed inference improves grade 1 detection or small-vessel Dice at comparable latency.

The strongest practical competitor is nnU-Net sliding-window inference with default overlap and Gaussian blending. We run it in two forms: sequentially on one GPU, as deployed, and with patches distributed across the same one to four GPUs we use. The parallel form is the real threat, because it is already communication-free and needs no new theory. Both forms use the identical trained weights, so only the inference scheme differs. We beat it if, at matched compute (total voxels processed, including redundant buffer voxels), our calibrated buffer gives lower worst-case disagreement with the full-volume reference. We also count it a win if our method reaches the same disagreement with fewer redundant voxels. Separately, the coarse correction must improve vertebral labeling and grading where blending alone does not.

The structural competitor is the nnU-Net 3D cascade, in which a low-resolution pass is followed by full resolution. It is trained with the same data and tuning budget. If it matches our two-level scheme on grading and vessel consistency, the conditioning hand-off adds nothing.

The exactness reference is per-layer halo exchange in the DistDL style. It serves as an upper bound on agreement and a lower bound on communication cost on a workstation without InfiniBand.

For external context only, the commercial ensemble SpineQ reached AUROC 0.964 for vertebral-level moderate-to-severe fractures on VerSe 19/20 in Diagnostic accuracy of deep learning vs. human raters for detecting osteoporotic vertebral compression fractures in routine CT scans. In that study, in-house DenseNet121/SeResNet50 ensembles reached 0.923 and attending neuroradiologists 0.950. We cannot retrain SpineQ, so the fair comparison is against our in-house baselines. Approaching 0.964 would be informative, not required.

Three ablations isolate the key ingredients. The first removes the coarse pass. The second replaces the decay-derived buffer with a fixed buffer equal to nnU-Net's default overlap. The third passes coarse information only as crop location, without conditioning.

Why not just…?

Why not just downsample the whole scan? It fits on one GPU and keeps global context. The cost is resolution, exactly where unassisted readers already struggle: A Vertebral Segmentation Dataset with Fracture Grading notes up to 85% of osteoporotic compression fractures are missed on CT, and mild fractures are defined by 20–25% height loss. Our downsampling baseline measures this directly through grade 1 sensitivity and small-vessel Dice. If downsampling loses nothing there, the case for full-resolution decomposition collapses, and we will report that.

Why not just run nnU-Net's sliding window in parallel with a generous overlap? This is the serious threat. For purely local labels it may work as well as anything we build. The experiments settle it in two ways. If the measured ℓ is short and default overlap already sits below tolerance, the buffer rule's contribution reduces to a diagnostic that says when default overlap is safe. That is still useful for deployment, but it is a smaller claim, and we will frame it as such. Where our prediction differs is the nonlocal outputs. Overlap cannot tell a sub-volume containing two vertebrae which levels they are, or what the adjacent level's height is. A window large enough to infer level identity approaches the full volume.

Why not just use the nnU-Net cascade, which is already coarse-then-fine? Structurally it is close. The difference we test is twofold. First, the fine stage receives explicit level labels and reference heights rather than only an upsampled probability map. Second, the fine stage runs as independent parallel sub-volumes with calibrated buffers. If the cascade matches us on vertebral identification and Genant AUROC under equal training budget, we drop the conditioning claim.

Why not just use exact halo exchange? Machine learning and spatial decomposition for large CT scans. gives exactness but relies on fast interconnects. We will measure its latency on PCIe-connected workstation GPUs. If its overhead turns out to be small there, an approximate method is unnecessary for inference, and the locality measurement remains mainly a tool for training-time decomposition.

Proposed Experiments

The decisive checks are three.

The first tests the decay law. Does $s(d)$ fit an exponential in distance with a class-dependent ℓ, and does ℓ fit on calibration scans predict stitching error on held-out VerSe and TotalSegmentator volumes within a factor of two? If the fit is algebraic everywhere, the gapped analogy fails, and buffer sizing must be empirical.

The second tests the gapped/gapless split. We expect bone and solid-organ voxels to show short ℓ, and portal, splenic and other small branching vessels to show long ℓ or algebraic decay. If so, buffer-only decomposition should degrade vessel consistency, measured with the metric from Segmenting Whole-Body MRI and CT for Multiorgan Anatomic Structure Delineation, while leaving bone Dice intact.

The third tests whether the coarse correction is necessary. On VerSe, removing the coarse pass should sharply increase vertebral level misidentification and lower vertebral-level Genant 2–3 AUROC. Restoring it should recover full-volume performance at a fraction of full-volume memory.

Throughout, we report:

  • agreement with full-volume output, as maximum and mean probability difference;
  • downstream Dice;
  • vertebral identification rate;
  • vertebral- and patient-level grading AUROC;
  • per-GPU memory;
  • redundant-voxel overhead;
  • wall-clock latency on one, two and four GPU workstations.

No reported result was found on Lacuna for decomposed or sliding-window inference latency on VerSe or TotalSegmentator, so these latencies are new measurements, not comparisons to published figures.