Keeping Small Lesions Under a Token Budget: Label-Aware Redundancy Selection for 3D CT Language Models

A chest or abdominal CT scan, cut into patches for a vision encoder, yields tens of thousands of visual tokens, which is far more than a language model can read. Current systems shrink this stream in one of three ways. They average neighbouring tokens, they let a small set of learned queries summarize everything, or they crop to an organ and then shrink. Each of these can silently erase a four-millimetre nodule that appears on only two or three slices. Meanwhile, most of the tokens they keep describe healthy tissue that is nearly identical from one slice to the next. Radiomics researchers solved a structurally identical problem years ago for hand-crafted features. Their tool is minimum-redundancy maximum-relevance selection (mRMR): pick features that are informative about the diagnosis but not informative about each other. That idea has never been applied to the visual tokens a 3D medical language model consumes.

We propose to do exactly that. A frozen 3D CT encoder produces tokens. A cheap probe estimates how much each token says about a set of report-derived findings. A greedy mRMR selector then keeps a fixed budget of tokens that are individually informative and mutually non-redundant. Each kept token retains its 3D coordinates. An organ mask enters only as a soft prior that tapers off outside the organ, never as a hard crop. The claim is specific: at tight token budgets, label-aware redundancy selection preserves rare, small findings that both cropping-plus-pooling and label-agnostic diversity pruning lose. Because the selector spends little of the budget on repeated parenchyma, it should also match their overall report quality.

Core Claim and What Is New

The closest work is Resolution Meets Reduction. It crops CT volumes to TotalSegmentator organ masks and then compresses tokens with average pooling, a PerceiverResampler (learned cross-attention queries), or TokenPacker. Cropping was the most impactful choice in 19 of 20 configurations, and the paper reaches a clinical macro F1 of 49.5 on CT-RATE and 49.0 on Merlin. None of its compressors asks whether the kept tokens duplicate each other or whether they carry diagnostic information. Its crop is also hard: anything outside the mask is gone, including peritumoral tissue, and so is any lesion the segmenter clips.

The second closest is PruneSID. It already balances importance against diversity for 2D natural-image VLMs, keeping 64 of 576 tokens at 96.3% of LLaVA-1.5 accuracy. However, its importance score comes from internal attention and its diversity from token-space PCA, with no reference to any target. The authors themselves flag the risk of pruning tiny but decisive details. Our proposal differs from both in three ways that we will test separately. First, relevance is defined against diagnostic labels rather than attention. Second, redundancy is measured in 3D, where the axial direction is the dominant source of repetition. Third, the anatomical mask is a prior on relevance rather than a filter on the input.

The radiomics line motivates the method and supplies its form. Huang et al. cut 1,252 CT features to 9 with mRMR, and Wu et al. cut 1,781 to 10 per contrast phase. In both cases a nearly total redundancy among descriptors of the same tissue was removed without hurting external performance. We move that selection from columns of a feature table to positions in a volume.

Method

A frozen 3D encoder produces tokens $t_1,\dots,t_N$, each with a voxel-space position. Report-derived binary findings $y_1,\dots,y_C$ supervise a small per-token probe that outputs $p(y_c \mid t_i)$. The probe is trained as a multiple-instance model, meaning that only scan-level labels are needed. The relevance of a token is its expected information about the findings, which can be computed at test time without labels:

$$r_i = \sum_{c=1}^{C} \mathrm{KL}\big(p(y_c \mid t_i)\,\|\,p(y_c)\big)$$

Here $p(y_c)$ is the training-set prevalence of finding $c$. This quantity is the pointwise contribution of token $i$ to the mutual information between token and label, which is the relevance term of mRMR. A token showing ordinary lung parenchyma moves the posterior little. A token over a nodule moves the "nodule" posterior a lot, however rare such tokens are.

Selection is greedy. At each step the selector adds the token that maximizes

$$r_i + \lambda \log m_i - \frac{\beta}{|S|}\sum_{j \in S} k(t_i, t_j)$$

The terms are defined as follows. $S$ is the set already chosen. $m_i \in (0,1]$ is a soft anatomical prior: one inside the dilated TotalSegmentator organ mask, decaying with distance outside it. $k$ is a similarity, the cosine similarity of probe posteriors concatenated with embeddings, which is cheap to compute and stands in for the pairwise mutual information term. $\lambda$ and $\beta$ trade the prior and redundancy against relevance. The selector stops when the budget $K$ is filled.

With $K$ in the hundreds and $N$ in the tens of thousands, greedy selection costs $O(KN)$ similarity evaluations, which is negligible next to the language model's forward pass. This removes the quadratic mutual-information estimation cost that limits classical mRMR. Kept tokens receive tri-axial positional embeddings in the style of OmniCT, so the language model knows where in the body each token lies. Finally, a two-layer MLP projector maps the tokens into the language model, which is fine-tuned for report generation.

Research Program

The work has three parts. The first is the selector itself, built on the same frozen encoder and language model used by Resolution Meets Reduction, so that differences come only from what reaches the language model. The second is a set of analyses of where the budget goes. We will measure the fraction of kept tokens inside versus outside the organ, the axial spread of kept tokens, and the recall of tokens overlapping annotated lesions where masks exist. The third is a robustness study. We will deliberately erode or shift the upstream organ mask to imitate segmentation failure, which is the single-point-of-failure risk raised for two-stage pipelines, and compare a hard crop against the soft prior.

Baselines

The naive reference is uniform 3D average pooling of whole-volume tokens to budget $K$. It shows what is lost by spending the budget evenly. Random selection of $K$ tokens inside the dilated mask is added as a sanity floor.

The strongest existing method is anatomy-guided cropping followed by a PerceiverResampler, as in Resolution Meets Reduction. That paper reports clinical macro F1 of 49.5 on CT-RATE and 49.0 on Merlin. The file does not state the token budget behind those numbers. We will therefore rerun this pipeline ourselves at each budget, with the same encoder, language model, training steps, and hyperparameter search size as our method. We will treat the published figures as a check that our reproduction is faithful. That paper also notes that an uncompressed MLP projector over cropped tokens is very hard to beat when the budget allows, so we include it as an upper reference at the largest feasible budget.

The strongest redundancy-aware competitor is PruneSID, ported to 3D tokens inside the same crop at matched budgets. No reported result was found on Lacuna for PruneSID on any CT benchmark, so all its numbers here will be ours.

Three ablations isolate our ingredients. Relevance-only top-$K$ sets $\beta = 0$. Redundancy-only selection sets relevance to a constant. A hard-crop version of our selector sets $m_i \in \{0,1\}$.

Beating the field means two things. At budgets of 128 tokens or fewer, we must exceed cropped-PerceiverResampler macro F1 on CT-RATE and Merlin by a margin larger than the seed-to-seed spread across three seeds. We must also show a clearly larger gain on the small-finding subset described below. Matching overall F1 while winning on small findings would still be a meaningful result. Losing on small findings would falsify the core claim.

Why not just…?

Why not just crop to the organ and use a PerceiverResampler, as Resolution Meets Reduction already does? This is the real threat, and the file gives no evidence that it fails on small lesions. That failure is our hypothesis, not a finding. Learned queries are trained only through the report-generation loss. Rare small findings contribute little to that loss, so the queries have little pressure to reserve capacity for them. The experiment settles the question directly. If cropped-Perceiver matches us on the small-finding subset at tight budgets, the label-aware selector adds nothing and we will report that.

Why not just use PruneSID-style importance and diversity, which already embodies the mRMR intuition? Its importance comes from attention and its diversity is label-free. A nodule token that looks like nearby parenchyma in embedding space can be suppressed as a near-duplicate, a risk the authors acknowledge. Our relevance-only and redundancy-only ablations, together with the PruneSID port, separate whether the gain comes from labels, from 3D redundancy, or from neither.

Why not just drop tokens that match the same position on the adjacent slice? Axial deduplication is cheap and probably captures much of the redundancy. We include it as an extra baseline: remove tokens whose cosine similarity to the token at the same position on the previous slice exceeds a threshold, then fill the remaining budget uniformly. Unlike mRMR, it cannot choose between two non-redundant tokens by diagnostic value. Under a tight budget we expect that choice to matter. If it does not, the simpler rule wins.

Why not just raise the budget and use the plain MLP? Where context and latency allow, that may be best, as Jo et al. found. Our claim is limited to the regime where they do not. This is why every comparison is reported as a curve over budgets 64, 128, 256, and 512 rather than at a single point.

Proposed Experiments and Decisive Checks

Training and in-distribution testing use CT-RATE (chest) and Merlin (abdomen). Out-of-distribution transfer is tested on RadChestCT, where BTB3D reported a 46% relative F1 gain. That gain came from a different, wavelet-and-causal-convolution tokenizer, and we cite it as context rather than as a matched baseline. The primary metric is clinical macro F1 at each budget.

The first decisive check is a small-finding subset. We will select test reports that mention nodules, cysts, or stones with a stated size under one centimetre, and score per-finding recall of those mentions in generated reports.

The second check targets spatial grounding. Your other Left! showed that VLMs fall to chance on relative anatomical position and lean on memorized textbook anatomy. We will therefore score whether laterality and lobe statements in generated reports agree with the reference. We will repeat the scoring on left-right flipped volumes, to see whether kept positional tokens or textbook priors drive these statements.

The third check is robustness to mask erosion. We will shrink organ masks by 5 to 15 mm and report the F1 drop for hard-crop pipelines versus the soft prior. The soft prior should degrade more gracefully, because relevant tokens just outside the eroded mask can still win selection.

The proposal is falsified if either of two things happens. One is that cropped-PerceiverResampler or axial deduplication matches our small-finding recall at 128 tokens or fewer. The other is that the relevance-only ablation matches the full selector, which would mean the redundancy term contributes nothing.