TL;DR
Automating 3D radiology report generation using vision-language models (VLMs) is severely bottlenecked by the massive number of visual tokens generated by 3D CT scans. This paper systematically evaluates how to optimize this "vision-token budget," demonstrating that anatomy-guided region-of-interest (ROI) cropping combined with advanced token compression achieves state-of-the-art clinical accuracy on large-scale benchmarks.
What Problem Does This Paper Address?
When applying modern Vision-Language Models (VLMs) to 3D medical imaging like Computed Tomography (CT) scans, researchers run into a massive computational bottleneck: a single 3D volume can easily generate tens of thousands of vision tokens. Passing this enormous sequence straight into a Large Language Model (LLM) overwhelms its context window and skyrockets compute costs.
While we can use "projectors" to compress these vision tokens before they reach the LLM, aggressive compression risks discarding critical clinical details. Conversely, efficient compression can actually allow us to feed higher-resolution images into the system without increasing the downstream token count. This creates a complex design challenge: How should a practitioner allocate their fixed vision-token budget across the input field of view (FOV), spatial resolution, and token-reduction projection methods?
Methods
The authors design a controlled, three-stage VLM pipeline to isolate and systematically evaluate each design choice:
- Input Preprocessing Regimes: They test three approaches: encoding the Whole volume, ROI cropping (focusing only on target anatomy), and HighRes encoding (using multi-block or denser axial features to scale up resolution).
- Vision Encoders (VE): They benchmark four distinct medical imaging foundation models spanning both CNN and Vision Transformer (ViT) architectures (detailed in the paper's encoder comparison table).
- Vision-to-Language Projectors: They evaluate five token-reducing projectors divided into two families:
- Grid-based: AveragePool, ConcatAdapter, and TokenPacker (which maintain spatial topology).
- Query-based: AttentionPool and PerceiverResampler (which use learnable tokens and cross-attention).
- Baseline: A token-preserving Multilayer Perceptron (MLP).
- Large Language Models: They test five instruction-tuned LLMs ranging from 1.7B to 4B parameters (Qwen3 variants, Phi-4-mini, and Gemma3-4B).
To ensure fair comparisons, they implement "Token-Budget Matching," forcing different projector families to output the exact same sequence length for a given compression ratio.
Datasets
The framework was trained and evaluated on two massive CT image-report datasets:
- CT-RATE: 50,188 non-contrast chest CT volumes, used as the primary development dataset. The authors used an axis-aligned bounding box around the lungs as the ROI.
- Merlin: 25,494 abdominal CT-report pairs, used for cross-dataset evaluation. A whole-body foreground mask served as the ROI.
For evaluation, the authors leveraged automated clinical labelers (RadBERT for CT-RATE and a custom-trained ModernBERT classifier for Merlin) to calculate a clinical macro F1 score based on detected abnormalities rather than relying purely on surface-level text matching (lexical metrics).
Key Insights and Ideas
- Anatomy-Guided Cropping is a Universal Win: Cropping the volume to the relevant ROI was the most consistent intervention, improving clinical macro F1 in 19 out of 20 configurations. By removing non-body background noise, the target anatomy is represented at a higher effective resolution without costing a single extra token.
- The Vision Encoder Dominates the Pipeline: The choice of vision encoder has a massive impact on downstream performance (up to a 16-point F1 spread), completely overshadowing the choice of the LLM (which typically only caused a 2–5 point variance).
- Most Projectors Can't Beat the Raw Baseline: When keeping the input resolution fixed, token-reducing projectors rarely outperform a simple, compression-free MLP baseline. Token reduction should primarily be used as an enabler for higher-resolution inputs rather than a compression tool for low-resolution inputs.
- Query-Based Models Handle Aggressive Compression Best: When forced to compress tokens heavily (up to 64x) to accommodate high-resolution inputs, the PerceiverResampler and TokenPacker significantly outperformed simpler pooling methods. They excel at distilling fine-grained spatial details—like small gallstones or renal cysts—into a compact token budget.
Key Results
The authors' optimized configurations achieved new state-of-the-art clinical macro F1 scores on both test sets:
- CT-RATE: Reached 49.5 F1 using a slice-based 2D ViT (Curia-64S) paired with a PerceiverResampler and Gemma3-4B, outperforming the previous best published system (AdaRAG-CT at 48.0).
- Merlin: Reached 49.0 F1 using the 3D ViT (Primus-1B) with an uncompressed MLP, drastically outperforming prior baselines like Jolia (23.8).
Interestingly, the top-performing models clinically did not always score the highest on traditional lexical metrics like BLEU, reinforcing the machine learning community's growing realization that n-gram overlap is a poor proxy for clinical accuracy in radiology.
Limitations and Future Work
- Frozen Vision Encoders: The vision encoders remained frozen during training. Jointly fine-tuning the encoder alongside the projector and LLM might unlock better representations but requires immense compute.
- Compute Constraints: Due to the massive scale of the study (which consumed roughly 60,000 A100 and 6,000 H100 GPU hours), the full hyperparameter search was restricted to a single encoder configuration on CT-RATE and transferred elsewhere.
- Not Ready for Deployment: With precision and recall hovering around 50%, the authors explicitly note that these systems are currently valuable for comparing design choices rather than being deployable clinical report generators.
Summary updated