Hospitals acquire MRI scans with very different slice thicknesses. Within each slice the image is sharp, but the gap between slices can be several times larger than the in-plane pixel size. A segmentation model trained on one kind of scan, for example contrast-enhanced T1 MRI, and then adapted without labels to another, for example high-resolution T2 MRI, has to cope with two shifts at once. One is the change in tissue contrast, which cross-modality methods are built to handle. The other is a change in through-plane sampling, which they mostly ignore. On the CrossMoDA benchmark for vestibular schwannoma, a tumor on the hearing nerve, results from unlabeled adaptation have stalled near 88% Dice. The challenge organizers note that their 10-site surveillance cohort varies widely in slice thickness and slice count, yet the leading pipelines still translate slice by slice and then run nnU-Net (crossMoDA Challenge Evolution 2021–2023).
We propose to test whether through-plane resolution mismatch is a real, separable cause of this plateau, and to remove it in a specific way. Each scan's thick slice axis is filled in by a progressive upsampler, one that doubles resolution in several small steps rather than one large jump. The upsampler learns only from the same scan's sharp in-plane directions, so it needs no thin-slice ground truth, no paired modalities and no registration. The cross-modality question then applies to the upsampler itself. We ask whether an upsampler trained on T1 contrast restores T2 anatomy, or whether adapting it to each scan at test time is required.
Core Claim
Our claim has two parts. First, part of the gap between unlabeled cross-modality adaptation and full supervision is caused by unequal through-plane resolution across modalities and sites, not by contrast. The claim predicts that, under a standard pipeline, target-domain Dice falls as slice thickness grows, and that the fall is steepest for thin structures such as the cochlea.
Second, this gap can be closed better by learned progressive upsampling than by resampling or blur augmentation, provided the upsampler is adapted to each scan. Such an upsampler brings in anatomical detail from the scan's own high-resolution in-plane axes, which a segmenter trained on blurred data never sees.
If the first part fails, meaning Dice does not depend on slice thickness once site is controlled for, we stop and report that negative result. That result would itself tell the CrossMoDA community something useful.
Relation to Prior Work
Three lines of work motivate the method and supply its parts.
The first is volumetric adaptation. SDC-UDA translates 3-slice mini-volumes with attention within and across slices, which reduces slice-to-slice "flickering" and raises CrossMoDA mean Dice to 84.8. It works at the native resolution, though, and never changes the sampling grid.
The second is through-plane slice synthesis. I³Net fills in missing slices by borrowing detail from the in-plane axes, reaching 43.90 dB on the Medical Segmentation Decathlon at 2×. It does this in a single fixed 2× step, within one modality, and is never used for domain adaptation. We reuse its core idea of borrowing in-plane detail.
The third is progressive upsampling. P-GAN chains 2× stages and adds a triplet loss between stages, which pushes each stage's output closer to the high-resolution target than the previous stage's output. Lyu et al. report that a two-level 2×→4× MRI network beats its single-level version, 30.94 dB against 28.20 dB on NAMIC. Both papers work on 2D in-plane images with registered data.
Two further methods constrain the design. Cohf-T and Lyu et al. use a second contrast to guide super-resolution, but both assume perfect co-registration. Our design uses no second scan at all, so it does not share that assumption. CARVE finds that, at a fixed token budget, adding in-plane resolution helps more than adding slices. That result is a caution for our premise: extra slices may carry little information. We treat it as a hypothesis to test, not a result to dismiss.
Research Program
The upsampler. We build a 3D upsampler that raises through-plane resolution in 2× stages until the volume is near-isotropic. For a 4× gap it runs two stages, and for an 8× gap it runs three. Each stage is a small anisotropic 3D network with a larger receptive field in-plane than across slices.
Training signal. Training pairs come from the scan's in-plane axes. We take a sagittal or coronal line of the sharp in-plane grid and degrade it with a simulated slice profile, either a boxcar or a Gaussian whose width matches the scan's stated slice thickness. The network then learns to reverse that degradation. This is the self-supervised in-plane signal I³Net relies on, applied at every stage. Each stage also receives a P-GAN-style triplet loss:
$$ \mathcal{L}_s = \|y_s - y\|_1 + \max\big(0,\ \|y_s - y\| - \|y_{s-1}\uparrow - y\| + m\big), $$
where $y_s$ is the stage-$s$ output, $y_{s-1}\uparrow$ is the previous stage's output resampled to the same grid, $y$ is the in-plane-derived target, and $m$ is a margin.
Three versions of the upsampler. We compare three versions to answer the cross-modality question. The first is trained on source ceT1 only. The second is trained on the pooled unlabeled ceT1 and hrT2 scans. The third is the pooled model fine-tuned for a few hundred steps on each test scan's own in-plane data.
Downstream pipeline. After upsampling, every volume is resampled to one common isotropic grid. It then goes through a fixed CrossMoDA-style pipeline: CUT or CycleGAN translation from ceT1 to hrT2, nnU-Net segmentation and pseudo-label self-training. This follows the structure the 2021 benchmark reports as dominant. The pipeline is identical in every arm of the study, so any difference in Dice comes from the geometry of the input grid.
Baselines
The do-nothing reference. The pipeline above uses nnU-Net's default handling of anisotropic spacing plus standard trilinear or B-spline resampling to the common grid. Every other arm is measured against this.
The strongest existing reference point. CrossMoDA 2021 top teams reached median Dice of 87.0% for the tumor and 85.7% for the cochlea. Fully supervised models reached 92.5% and 87.7% (CrossMoDA 2021). The later editions settled at about 88% (Evolution). SDC-UDA reports a mean Dice of 84.8.
We cannot rerun the winning teams' systems exactly. Our own reimplemented pipeline therefore serves as the in-house strongest baseline, and SDC-UDA's volumetric translation is a second translation arm. We compare against the published numbers only on the official splits.
Thick-slice augmentation. This is the most dangerous competitor. During nnU-Net training, source volumes are randomly degraded with the same slice-profile model and a range of thicknesses. It gets the same training epochs and the same hyperparameter search.
Single-step upsampler. This is an I³Net-style network that closes the full through-plane gap in one pass. It is matched in parameter count and training steps, so the comparison isolates the effect of splitting the gap into stages.
Ablations of the key ingredients. We run the progressive model without the triplet term. We also compare the source-only and pooled upsamplers against the per-scan-adapted one, which isolates the value of test-time self-supervision.
What counts as winning. The proposal succeeds if the per-scan progressive arm beats both resampling and augmentation by at least 2 Dice points on the thickest third of target scans, with a paired bootstrap interval that excludes zero. On the thinnest third it should cause no loss.
Why not just…?
Why not just resample to isotropic, as nnU-Net already does? Classical interpolation smears thin structures across slices. I³Net documents this loss of vessel and wall boundaries under interpolation. A tumor or cochlea spanning only a few slices is exactly the case where this matters. Our do-nothing arm measures the effect directly, stratified by slice thickness.
Why not just augment the source with simulated thick slices? This is a real threat, and it may match our method. Augmentation teaches the segmenter to tolerate blur. It cannot add structure, and the file flags an information bottleneck at extreme factors that no method removes. Our only advantage is the scan-specific prior from in-plane data. If augmentation equals the per-scan upsampler, we will conclude that the upsampler adds nothing and report that. We also run augmentation combined with the upsampler, in case the two are complementary.
Why not just use one upsampling step, as I³Net does? Lyu et al.'s 2.74 dB gain from staging and P-GAN's collapse of single-stage models beyond 4–8× point toward progressive designs at large factors. Both results come from in-plane 2D super-resolution, not from through-plane synthesis. The matched single-step arm settles this, and we expect the two to tie at 2×.
Proposed Experiments and Decisive Checks
Experiment 1: does the premise hold? Using the reimplemented pipeline, we regress target Dice and average symmetric surface distance (ASSD) on slice thickness, with site as a covariate. This uses the CrossMoDA 2023 multi-site data wherever labels are accessible, and challenge submission for the private test sets. A flat relationship ends the project.
Experiment 2: does the upsampler transfer across contrasts? We use volumes that are high-resolution along all axes, from HCP T1 and from IXI T1, T2 and PD. We degrade their slice axis retrospectively at 2×, 4× and 8×, which gives true ground truth for the missing slices. Each of the three upsampler versions is trained on one contrast and scored with PSNR and SSIM on the others.
For context, SuperFormer reports 32.47 dB PSNR on HCP, but on a different task, k-space super-resolution, so the number is not comparable. We found no reported result on Lacuna for through-plane cross-contrast transfer. Experiment 2 decides whether per-scan adaptation is necessary.
Experiment 3: does it help segmentation? We run the full arms comparison on CrossMoDA for both the tumor and the cochlea, reporting Dice, ASSD and Koos grading error. The leading reported Koos mean absolute error is 0.26.
Experiment 4: does it generalize beyond the ear? As a secondary check, we repeat the comparison on MMWHS MRI→CT. SDC-UDA reports gains there but gives no numbers in the file, so we will report our own numbers against our own rerun of it.
The decisive result. The whole proposal rests on the stratified comparison between the augmentation arm and the per-scan progressive arm on thick-slice target scans.
References
- crossMoDA Challenge: Evolution of Cross-Modality Domain Adaptation Techniques for Vestibular Schwannoma and Cochlea Segmentation from 2021 to 2023
- SDC-UDA: Volumetric Unsupervised Domain Adaptation Framework for Slice-Direction Continuous Cross-Modality Medical Image Segmentation
- I³Net: Inter-Intra-Slice Interpolation Network for Medical Slice Synthesis
- Progressive Generative Adversarial Networks for Medical Image Super resolution
- Multi-Contrast Super-Resolution MRI Through a Progressive Network
- Cross-Modality High-Frequency Transformer for MR Image Super-Resolution
- CARVE: Cross-Slice Anisotropic Reallocation of Visual Evidence for Efficient 3D Medical Volume Understanding
- CrossMoDA 2021 challenge: Benchmark of cross-modality domain adaptation techniques for vestibular schwannoma and cochlea segmentation