How Much of Body-Shape Risk Prediction Is Really About Fat?

Deep networks can now read disease risk off the outside of the body. On AbdCTBench, a small image model trained on depth maps of the abdominal surface, extracted from CT scans, predicts mortality, diabetes with complications and aortic calcification with AUROCs above 0.8. A depth map is an image whose pixel values record distance to the skin. Clinicians who see such a model will ask the obvious question: is it detecting harmful visceral fat, the fat packed around the organs, or is it detecting something else, such as age, posture or scanner habits? Current practice answers with heat maps drawn after the fact, and those maps cannot measure a fat volume. We propose to answer the question directly. We force the prediction through a narrow layer of measured tissue quantities and then account exactly for how much predictive signal is lost along the way.

The method is a concept bottleneck model, meaning a network made to first predict human-readable intermediate quantities and then predict the outcome from those quantities alone. We apply it to abdominal surface geometry, using CT-measured tissue volumes as the intermediate "concepts." The contribution is an audit, not the architecture. The dataset contains the true CT tissue measurements for every patient, so we can split the gap between the black-box model and the bottleneck model into two parts. The first part is lost because tissue volumes are estimated imperfectly from the surface. The second part is lost because tissue volumes are an incomplete explanation of what the surface reveals about risk. The two parts call for opposite fixes, and no existing work separates them.

Core Claim

Let $A_{\text{bb}}$ be the test AUROC of an unconstrained image model on the depth maps. Let $A_{\text{cbm}}$ be the AUROC of the model that predicts outcomes only from its own estimated tissue concepts. Let $A_{\text{or}}$ be the AUROC of the same outcome head fed the true CT-measured concepts, which we call the oracle. Then

$$A_{\text{bb}} - A_{\text{cbm}} = \underbrace{(A_{\text{or}} - A_{\text{cbm}})}_{\text{concept estimation loss}} + \underbrace{(A_{\text{bb}} - A_{\text{or}})}_{\text{concept incompleteness}}.$$

The identity is trivial. Estimating it with confidence intervals on a benchmark of roughly 23,500 scans is not.

If estimation loss dominates, the path forward is better surface-to-tissue regressors, and the tissue explanation holds. If incompleteness dominates, the black box uses information outside the named compartments. We would then have to find out what that information is before any clinician trusts a statement like "high risk because of visceral fat."

Our hypothesis for the cardiometabolic endpoints is that incompleteness is small once age and sex are included as explicit concepts. We expect most of the black-box advantage to come from age, which AbdCTBench shows the surface encodes with a mean absolute error of 6.22 years. Mortality may prove different. The finding matters in either direction.

Prior Work and Positioning

The surface-geometry literature motivates the question. AbdCTBench renders abdominal CT surfaces to depth maps and trains ResNet and vision-transformer models end-to-end on outcomes. It shows the signal exists, but it never routes predictions through its 16 CT biomarkers, extracted with the OSCAR tool. Those biomarkers include organ volumes, visceral and subcutaneous fat, and aortic calcium. Silhouette images enable estimation of body fat distribution predicts visceral, abdominal subcutaneous and gluteofemoral fat from MRI silhouettes. It then fits separate epidemiological regressions, finding an odds ratio of 1.70 in males and 1.74 in females for type 2 diabetes per standard deviation of predicted visceral-to-subcutaneous fat ratio, adjusted for BMI and waist.

That is a two-stage pipeline, close in form to what the concept-bottleneck literature calls a sequential model. It never asks how much outcome signal a direct image model would capture beyond the fat estimates, and it offers no correction at test time. 3D convolutional deep learning for body composition constrains our design, because it shows the surface-to-tissue mapping is nonlinear and behaves differently by sex. For that reason every result below is stratified by sex.

The interpretability literature supplies the method and the cautions. Concept Bottleneck Models defines the independent, sequential and joint training schemes and shows that correcting predicted concepts at test time reduces error on knee X-rays. Concept Complement Bottleneck Model adds an unsupervised side channel to cover missing concepts and reports performance within 1–2% of black-box models. Both papers note that such side channels can leak uninterpretable information, and that warning constrains us. We use a side channel only as a measuring instrument, with swept capacity, never as a deployed component.

Post-hoc attribution is the status quo we argue against. Opportunistic detection of type 2 diabetes from chest radiographs infers from occlusion maps that its model looks at mediastinal fat, but it measures no fat volume. SHAP-based explanations are sensitive to feature representation shows that such attributions change with how features are encoded. A multimodal pancreatic cancer model uses SHAP on a random forest to name CT visceral fat as a driver of recurrence. We differ from all three by making the tissue explanation a structural constraint whose cost is measured, rather than a story told after training.

Research Program

Concepts. The concept vector holds the OSCAR biomarkers available in AbdCTBench, plus age and sex. Age and sex are included as explicit concepts so that the bottleneck cannot be undermined by a demographic shortcut. When aortic calcium is itself the outcome, it is removed from the concept set.

Model. The encoder is the ResNet-18/34 depth-map backbone that AbdCTBench found competitive with transformers. The encoder regresses the concepts. The outcome head is deliberately simple, a sparse additive model with smooth per-concept curves, so that each concept's effect can be plotted and can show threshold effects. Such thresholds matter here: the METS-VF study of peripheral arterial disease reports that risk levels off above a visceral fat score of 8.63. The same head architecture is used for the bottleneck model and the oracle, so the decomposition compares like with like.

Side-channel probe. To study the incompleteness term, we add a residual side channel of width $r \in \{0, 1, 4, 16\}$ that feeds the outcome head directly. We trace AUROC as a function of $r$. For the learned residual dimensions, we then test what they encode. The checks are correlation with scan metadata, with comorbidity codes outside the concept set, and with depth-map regions identified by occlusion. A residual that tracks scanner or field-of-view is a shortcut. A residual that tracks something anatomical, such as organ shape not captured by volume, is a candidate new concept.

Intervention. A realistic use case is a patient with an old opportunistic CT scan whose outcome is being predicted from a new surface scan. For held-out patients, we replace subsets of predicted concepts with their CT-measured values and record the change in AUROC for each concept. This identifies which tissue measurements are worth acquiring.

Baselines

The naive reference is a logistic model on age and sex alone. We add waist-like perimeters computed directly from the surface mesh, and height and weight if the AbdCTBench metadata records them. This is the tape-measure reference, trained on the same splits.

The strongest competitor is the end-to-end AbdCTBench depth-map CNN. Its reported AUROCs are 0.801 for type 2 diabetes with chronic complications, 0.839 for mortality and 0.848 for high aortic calcium (AbdCTBench). We retrain it ourselves on identical splits, with the same backbone, augmentation and hyperparameter search budget as the bottleneck variants. This serves as a reproduction check against the published numbers and defines $A_{\text{bb}}$.

The second strong competitor is the two-stage silhouette-style pipeline, which is concept regression followed by a separately fitted outcome model, following the silhouette study. It is identical to our sequential variant, and we report it under that name.

Three ablations isolate the key ingredient. The first compares independent, sequential and joint training. The second is the side-channel width sweep. The third removes the fat concepts while keeping age and sex, which tests whether visceral fat carries signal beyond demographics.

"Beating" the black box is defined narrowly. The joint bottleneck model must come within 0.02 AUROC of $A_{\text{bb}}$, with a bootstrap interval overlapping the black box's. It must also show a positive AUROC gain from concept intervention, something the black box cannot offer at all. If the gap exceeds 0.02 at $r = 0$, we report the bottleneck model as not yet competitive and give the decomposition as the reason.

Why not just…?

Why not just use tape-measure indices such as waist-to-height or a body shape index? They are transparent and cheap, and we include them as the naive reference. The evidence says they underfit. In the silhouette study, anthropometric models reached $R^2$ of 0.171 in males and 0.262 in females for the visceral-to-subcutaneous ratio, against 0.553 and 0.504 for silhouettes. In the coronary case–control study, a body shape index alone reached AUROCs between 0.57 and 0.66. Our naive arm measures the same ceiling on this benchmark.

Why not just run SHAP or saliency on the black box? Such maps say where the model looks, not how much tissue is there. They also shift with feature representation (SHAP sensitivity). We will report occlusion maps for the black box and check whether they agree with the concepts that carry the most weight in the bottleneck. Disagreement between the two would itself be evidence against relying on saliency.

Why not just predict the tissues and then regress, as the silhouette paper does? This is the most serious threat, because a sequential bottleneck model is exactly that pipeline. We do not claim the architecture as new. The new parts are three. We compare the pipeline against a matched black box and a matched oracle, giving the decomposition. We test whether joint training shrinks the estimation-loss term. We report intervention gains. If the sequential model matches the joint model, we will say so, and the practical recommendation becomes the simple pipeline together with the audit.

Why not just use the real CT measurements? That requires CT, which involves radiation and cost, and the premise of surface-based risk prediction is to avoid it. The oracle arm uses real CT values precisely to bound what the surface-based bottleneck could achieve.

Proposed Experiments

The primary experiment runs the full decomposition on AbdCTBench for three outcomes: diabetes with complications, mortality and aortic calcium. We use patient-level splits so that a patient's multiple scans never appear in both training and test sets, and compute 1,000-sample bootstrap intervals on each term, stratified by sex.

The decisive check is the sign and size of the incompleteness term $A_{\text{bb}} - A_{\text{or}}$. If it is near zero, surface-based cardiometabolic risk is largely explained by tissue compartments plus age, and the bottleneck model is ready for clinical review. If it is large, the side-channel probe must either identify a shortcut or propose a new anatomical concept, which we would then validate by adding it and re-running.

A secondary replication runs the same decomposition on UK Biobank MRI silhouettes, using visceral, abdominal subcutaneous and gluteofemoral fat as concepts and incident type 2 diabetes as the outcome. The file contains no reported silhouette AUROC for incident type 2 diabetes, only odds ratios, so the retrained black box sets the reference there. A sex-stratified comparison across both datasets tests whether the known weaker surface-to-tissue mapping in women (3D body composition) shows up as a larger estimation-loss term in women.