Hearing What Patients Don't Say: Acoustic Evidence for Drug-Safety Mining of Patient Videos

Roughly 90 to 94 percent of harmful drug side effects are never reported to regulators (Predictive modeling of structured electronic health records for adverse drug event detection; Automated gathering of real-world data from online patient forums can complement pharmacovigilance for rare cancers). To recover some of these missed signals, "active pharmacovigilance" mines what patients post online. Today that mining is almost entirely text. When a patient records a video about starting a new blood-pressure pill, a text pipeline sees only what they say. It misses the dry cough that interrupts them every thirty seconds, and it misses the slurred articulation of someone three weeks into an antipsychotic. Patients often do not name these signs, either because they have not linked them to the drug or because they lack the words.

We propose to treat the non-speech part of patient audio as a separate, checkable source of evidence. The system splits the soundtrack into speech and non-speech. The speech becomes a transcript that says which drug the patient takes. Frozen health-acoustic models listen to the rest, along with voice quality, and detect specific physical signs. Those signs are turned into short, confidence-tagged text statements that a clinical text extractor reads next to the transcript. Every side effect the system outputs carries a tag saying whether it came from the patient's words or from the sound. The central question is empirical: does this acoustic channel recover real side effects that are absent from the transcript, without inventing ones driven by the model's expectations?

Core Claim

The claim has three parts. First, acoustic evidence adds measurable recall of side effects that the patient never mentions in words. Second, routing that evidence through explicit, verbalized findings works better than feeding raw audio tokens into a multimodal language model. Third, the system's drug–sign assertions can be shown to follow the actual audio, not the narrative context.

The second part follows directly from a result that works against naive fusion. AVHBench builds a benchmark of real and audio-swapped videos to probe audio-visual language models. It finds three problems:

  • These models often do worse with two modalities than with one.
  • They hallucinate sounds that their visual priors suggest should be there.
  • They do better when given text captions of the audio than when given the raw audio tokens.

In a safety setting, a model that "hears" a wheeze because the patient mentioned an inhaler is worse than useless.

We therefore do not propose another end-to-end audio-video-text network. We propose a narrow acoustic channel whose outputs are auditable.

Relation to Prior Work

The closest existing work. The closest multimodal side-effect work is MMADE. It pairs 1,500 static medical images, 81% of them skin, with patient text. It fine-tunes the connector module of InstructBLIP, the small bridge between image encoder and language model. Adding the image lifts MoverScore, a text-similarity metric, from 0.253 (text only) to 0.622.

MMADE motivates our proposal because it shows that sensory grounding compensates for vague patient language. Our work differs in four ways:

  • Modality: we use sound rather than photographs.
  • Visibility of the side effect: we target internal or systemic effects that no photo shows.
  • Provenance: we tag which source each finding came from.
  • Conflict testing: we test explicitly for cross-modal hallucination, which MMADE does not examine.

Text pipelines we build on and must beat. Deep-LLMADEminer is a tweet pipeline with three stages: RoBERTa classification, GPT-4 span extraction, and BioBERT mapping to MedDRA, the regulators' standard dictionary of side-effect terms. Its scores fall at each stage:

Stage F1
Classification 0.838
Span extraction 0.306
MedDRA mapping 0.354

BioDEX links PubMed papers to FDA reports. It finds that a fine-tuned FLAN-T5-Large (59.1% overall F1) beats few-shot GPT-4 (53.1%), yet reaction extraction stays near 34% F1.

These papers do two jobs here. They supply our text back end, a fine-tuned FLAN-T5 in the BioDEX style. They also show that the hard part is naming the reaction, which is exactly where an objective acoustic sign could help.

Acoustic methods we reuse. HeAR is a masked-autoencoder model, trained by hiding parts of an input and learning to fill them in. It was pretrained on 313 million two-second clips of coughs and breathing and reaches a mean reciprocal rank of 0.708 across 33 clinical probing tasks. We use it frozen, as the sign detector for non-speech sounds.

Its two-second window is a known limit. We work around it by aggregating episode counts over the whole video rather than claiming long-range modeling. For voice-quality signs such as dysarthria, we train probes using the TORGO dysarthric speech corpus (Enhancing AAC Software for Dysarthric Speakers).

Why we separate speech from non-speech. CLIP4VLA adds separate markers for verbal and non-verbal audio inside a CLIP model and reports that this helps. HEAR shows that video-dialogue models become "deaf": their BLEU_4 drops by up to 38.2% on audio-specific questions.

We take the design lesson from both but make the split hard and explicit: separate segments, separate models. A patient's spoken complaint and their cough are different kinds of evidence. The first is a claim; the second is an observation.

What we set aside. We deliberately do not adopt the heavier video machinery of CA2ST or HiTeA in the main system. Motion side effects such as tremor or dyskinesia are a natural extension. We leave them out because we do not want the first test of the idea to be confounded by visual static bias.

Research Program

Data. The first deliverable is a dataset, because none exists. We will collect public patient video diaries whose titles or transcripts name a drug, following the YouTube-mining logic HeAR used at scale. We will restrict collection to drug classes with well-established acoustic side effects that serve as positive controls:

  • ACE inhibitors, which cause dry cough;
  • antipsychotics and dopamine antagonists, which cause dysarthria and vocal tremor;
  • non-selective beta-blockers, which cause wheeze.

We will add matched videos about drugs without these labeled effects.

Clinically trained annotators will label each video with three things:

  • the drugs mentioned;
  • MedDRA preferred terms supported by the speech;
  • MedDRA terms supported by audible signs, with timestamps. This label is assigned by listening, and annotators are blinded to the transcript for the sign labels where possible.

The key subset is videos where an audible sign exists but the patient never names it. We will report its size honestly. If it turns out to be tiny, that is itself a finding about the idea's ceiling.

System. The system works in four steps:

  1. A speech-activity detector splits the audio into speech and non-speech segments.
  2. Speech goes to an ASR system, which yields the transcript.
  3. Non-speech segments go to frozen HeAR with linear probes for cough, wheeze, and stridor. Speech segments also go to voice-quality probes, trained on TORGO and a small in-domain split, for dysarthria and tremor.
  4. Probe outputs are calibrated, aggregated into episode rates over the video, and verbalized into short statements, for example "acoustic finding: dry cough, 9 episodes in 4 minutes, confidence 0.81." These statements are prepended to the transcript and passed to the fine-tuned text extractor.

The extractor outputs drug–MedDRA pairs with a source tag. A sign-derived term is emitted only if two conditions hold: its calibrated confidence clears a threshold chosen on validation data, and the transcript establishes a drug exposure. Otherwise the system abstains on that term.

Baselines

Naive reference points. There are two. The first is "do nothing," meaning the videos are not mined at all; its recall on unspoken signs is zero by construction. The second is the transcript-only pipeline: the same ASR, then a BioDEX-style fine-tuned FLAN-T5 extractor trained on our transcripts. We also run the published Deep-LLMADEminer stages on the transcripts for continuity with the field.

This is the baseline a reviewer will believe in, and it is strong on everything the patient says. On tweets, the best published text pipeline reaches 0.306 span F1 and 0.354 normalization F1 on SMM4H 2024 (Deep-LLMADEminer). On literature, reaction F1 is roughly 34% (BioDEX). Neither transfers directly to spoken transcripts, and no reported result was found on Lacuna for side-effect extraction from patient video transcripts. We therefore re-measure it ourselves.

Strongest end-to-end competitor. This is an audio-visual language model fine-tuned with LoRA (small trainable low-rank adapters) on our training split. AVHBench reports that this recipe moves Video-LLaMA on its audio-driven video hallucination task from roughly 50% to 83.9% accuracy (AVHBench). It is the most credible threat, because fine-tuning demonstrably repairs much of the hallucination problem. It gets the same training videos, the same labels, and a matched tuning budget measured in GPU-hours and hyperparameter trials.

Generic-caption competitor. A general audio captioner describes the non-speech segments in free text, and the same FLAN-T5 extractor reads those captions. This tests whether our targeted, calibrated clinical probes matter, or whether any verbalization of the audio suffices.

Fairness. All systems share the same splits, the same ASR, and the same extractor where applicable, and validation data is used only for thresholds.

What counts as beating the baselines. There are two requirements, and both must hold:

  • On the unspoken-sign subset, the system must show higher recall than every baseline, with bootstrap confidence intervals that exclude the transcript-only system.
  • On spoken terms, overall MedDRA-level F1 must not drop.

Ablations. Three ablations isolate the key ingredients:

  • Removing the speech/non-speech split: HeAR probes run on the whole soundtrack.
  • Removing calibration and abstention: raw probe scores are passed directly.
  • Removing the drug-exposure requirement for sign-derived terms.

Why not just…?

Why not just transcribe the audio and use a text pipeline? Transcription keeps the words and throws away the cough. For side effects the patient names, this is a real threat: our system may add nothing there, and we expect parity. The proposal only matters if the unspoken-sign subset is large enough to matter, so we measure its size before building anything elaborate. The transcript-only baseline then shows directly whether any recall is left on the table.

Why not just fine-tune an audio-visual LLM end to end? AVHBench shows that fine-tuning can raise accuracy sharply, so this could genuinely match us on in-distribution accuracy. Our bet rests on robustness and auditability rather than raw accuracy. The audio-swap test below checks whether the fine-tuned model's side-effect claims follow the sound or the story. If it passes that test as well as our system does and matches recall, the right conclusion is that the separate channel is unnecessary, and we will report it that way.

Why not just caption the audio with a generic model? AVHBench's own finding that captions beat raw tokens supports verbalization in general. What is not known is whether generic captions name clinically meaningful signs at a usable rate. The generic-caption baseline settles this. If it ties our targeted probes, the contribution shrinks to "verbalize audio before extraction," which is simpler and still useful.

Why not just concatenate encoder embeddings and train a classifier? HEAR's 38.2% BLEU_4 drop on audio questions shows that dominant streams tend to drown out audio when fusion is unguided. More basically, a concatenation classifier cannot tell a regulator which evidence produced a finding. We include it as a secondary baseline, but provenance, not accuracy, is the reason we do not adopt it.

Proposed Experiments and Decisive Checks

Main comparison. We report MedDRA-term precision, recall, and F1, split into spoken and unspoken-sign subsets, for all systems. We also report calibration error for the acoustic probes, and HeAR probe accuracy against the blinded timestamped labels.

Audio-swap counterfactual. Following AVHBench's construction, we swap soundtracks between videos. One case pairs an ACE-inhibitor narrative with a cough-free soundtrack; another pairs a cough-laden soundtrack with an unrelated-drug narrative. A trustworthy system's sign-derived terms must move with the audio.

The key measure is the rate of sign-derived "cough" assertions on the cough-free swaps. Each system's rate is compared with its rate on real cough-free videos. Any excess counts as prior-driven hallucination.

Aggregate positive-control check. This check asks whether the acoustic channel helps at the level of drug-safety signals. We compute a simple disproportionality statistic, which asks whether a drug–effect pair appears more often than chance, across the corpus. We compute it once with transcript-only extractions and once with transcript plus acoustic extractions.

Adding the acoustic channel should strengthen the known pairs, such as ACE inhibitor with cough, and should not create spurious pairs for the matched control drugs. If the unspoken-sign subset is negligible, or if the fine-tuned end-to-end model matches us on both recall and the swap test, the idea fails. That negative result would still tell the field where multimodal drug-safety effort should not go.