NeurIPS 2026Coming to NeurIPS?Explore papers, orals & directions

Fusing Slices Before Pooling: Global 3D Context for Fast Pulmonary Embolism Triage

Emergency chest CT scans for pulmonary embolism (a blood clot lodged in a lung artery) contain several hundred slices. A radiologist has to scroll through them one at a time, so reading time grows with slice count, and worklists back up. Automated pre-reading that moves likely-positive scans to the top of the queue is reported to cut reading times by 30–40% and to catch many clots missed in clinical reports (The promise and limitations of artificial intelligence in CTPA-based pulmonary embolism detection). The same review notes that false alarms lead clinicians to distrust or switch off these tools. The fastest accurate systems share one design. A pretrained 2D image network encodes each slice, each slice is squashed into a single feature vector, and a small sequence model reads the vectors in order. This design is cheap, and on the largest public benchmark it beats Vision Transformers and unordered pooling (Seeking an Optimal Approach for Computer-Aided Pulmonary Embolism Detection). Its blind spot is that collapsing each slice to one vector throws away where things are. The sequence model can learn that slice 140 looks suspicious and slice 145 looks suspicious. It cannot learn that both findings sit in the same artery, or that a filling defect in the right lower lobe co-occurs with an enlarged right ventricle sixty slices higher.

We propose to keep the per-slice 2D encoder and keep each slice's coarse spatial feature map instead of pooling it. The maps are stacked into a low-resolution 3D feature volume, and a few rounds of criss-cross attention run along all three axes. Criss-cross attention lets each position exchange information only with positions in its own row, column, and slice-column. After three rounds, every position in the volume can reach every other. This gives a fully global 3D receptive field, while keeping the extra cost small compared with the 2D encoder that already has to run. The claim is that the receptive-field bottleneck in fast CT triage is not the range of the slice aggregator. It is the spatial pooling that happens before aggregation. Fixing that should cut false alarms on clot-negative scans and improve the labels that require relating distant anatomy, at almost no latency cost.

Core Claim

The three directions in this note play different roles. Local receptive fields are the mechanism under study, inference latency is a hard budget, and radiologist workload is the evaluation setting. The specific hypothesis is that fast PE triage models fail mainly because they pool before fusing across slices. Global mixing over a coarse 3D map of 2D slice features should therefore beat both of the following:

  • global mixing over pooled slice vectors (the current best design);
  • local 3D mixing over the same coarse map.

The gains should concentrate in two places: specificity at high sensitivity, and labels that depend on long-range spatial relationships.

This differs from the closest prior work in clear ways.

  • The PE benchmark study (Seeking an Optimal Approach for Computer-Aided Pulmonary Embolism Detection) compared GRU aggregation and multiple instance learning over pooled slice embeddings. It never kept spatial maps, and it reported no latency.
  • CCNet (CCNet: Criss-Cross Attention for Semantic Segmentation) introduced criss-cross attention in 2D. Two passes are enough to connect all pixels, and it uses 11× less GPU memory and 85% fewer operations than a full non-local block. CCNet has not been applied to 3D volumes or to triage. We reuse its operator and extend it to three axes, which needs three passes rather than two to connect all positions.
  • Linear-time scanning models for medical images (EccoMamba, CT-Mamba) have to flatten images into a 1D sequence. EccoMamba documents that this breaks spatial continuity and introduces a bias toward the scan direction. Criss-cross attention has no scan order, so this problem does not arise.
  • DMFNet (3D Dilated Multi-Fiber Network for Real-time Brain Tumor Segmentation in MRI) shows that a lean 3D convolutional network can run in 0.019 s per brain MRI volume. Its context is bounded by dilation, and it was never evaluated for triage.

Research Program

The model has three parts.

Slice encoder. The first part is a 2D slice encoder initialized from the best transfer setting reported on the PE benchmark. That study found that CNNs beat ViTs by about 4% AUC. It also found that self-supervised pretraining beat supervised pretraining, and that ImageNet accuracy correlated with downstream AUC at 0.59. We therefore use an Xception-family CNN with Squeeze-and-Excitation blocks ("SeXception") or a ResNet initialized with self-supervised weights. The encoder runs on all slices in parallel and outputs a feature map at stride 16 for each slice.

3D fusion. The maps are stacked into a volume. For a 512-pixel slice this gives 32×32 positions per slice, multiplied by roughly 300 slices. A 1×1×1 convolution reduces the channel count. Three rounds of 3D criss-cross attention then run, with shared weights across rounds. At each position the attention covers about 32+32+300 entries rather than all ~300,000 positions. The fusion step therefore costs a small fraction of the encoder, and we will measure that fraction rather than assume it.

Output heads. The model has three heads:

  • an exam-level head for PE present or absent;
  • a slice-level head;
  • auxiliary exam heads for clot location, laterality, and the right-ventricle-to-left-ventricle size ratio.

The RSNA challenge release provides labels for clot location, laterality, and the ventricle ratio. The ventricle ratio is the strain measure the PE review identifies as central to downstream management. These heads serve as the long-range probe. Answering them requires relating cardiac chambers and lung arteries that lie far apart along the scan axis.

Localization map. Attention over the coarse volume also produces a coarse 3D localization map. This answers the complaint that triage models are black boxes, and it lets us score localization on per-clot benchmarks.

Analysis. The analysis step tests where any gain comes from. We stratify errors in four ways:

  • PE-negative scans, where false alarms live;
  • small or peripheral clots;
  • each auxiliary label;
  • scans whose arteries run obliquely through many slices.

If the gain does not concentrate where long-range spatial relations matter, the mechanistic claim fails, even if overall AUC improves.

Baselines

Naive reference. Arrival-order (first-in, first-out) reading combined with a prevalence-only classifier. This anchors the worklist simulation: any triage model must reduce time-to-read for positive exams relative to it.

Strongest existing method. The 2D CNN plus GRU pipeline from Seeking an Optimal Approach for Computer-Aided Pulmonary Embolism Detection. It reports 0.8912 mean exam-level AUC and 0.9634 image-level AUC (SeXception) on the RSNA PE Detection Challenge data. It is the strongest competitor because it is the best published result on the largest benchmark in the file, and that study directly showed it beats both ViTs and unordered pooling. We will reimplement it with the same encoder, the same pretraining, the same splits, and the same tuning budget as our model, and confirm that our version reproduces the reported AUC within a reasonable margin. Beating it means all of the following:

  • a higher exam-level AUC with non-overlapping bootstrap intervals;
  • a higher specificity at 95% sensitivity;
  • end-to-end latency per exam no more than 20% above the GRU pipeline on the same GPU.

Unordered pooling. Multiple instance learning with trainable adaptive pooling, as in Deep Learning Based Detection of Acute Aortic Syndrome in Contrast CT Images. It reached 0.985 AUC for aortic syndrome with 414,000 parameters, but it lost to GRU aggregation on PE. It runs on the same encoder.

Local 3D context baselines. We include two:

Ablations isolating the key ingredient. Two ablations decide the claim.

  • Pooling ablation. The same three-axis attention, but applied to pooled slice vectors, so it reduces to 1D attention along the scan axis. This changes only whether spatial maps survive.
  • Globality ablation. The coarse feature volume is kept, but criss-cross attention is replaced with stacked local 3×3×3 convolutions of matched parameter count and matched latency. This changes only whether mixing is global.

If either ablation matches the full model, the corresponding part of the claim is false. A third variant replaces criss-cross attention with a three-axis scanning state-space block. It tests whether scan-order bias, as documented by EccoMamba, matters in practice.

Why not just…?

Why not just keep the GRU over slice embeddings and make it faster? The latency argument against recurrence is weak, and we concede it. A GRU over 300 vectors costs almost nothing next to running the encoder on 300 slices. Our case against this baseline does not rest on speed. It rests on the pooling step that comes before the GRU. The pooling ablation settles this directly. If 1D aggregation over pooled vectors matches the spatially resolved model on the false-alarm and ventricle-ratio checks, the proposal's premise is wrong.

Why not just use unordered multiple instance learning, which won on aortic syndrome with 414,000 parameters? That success came after centerline straightening. Straightening already aligned the anatomy, so slice order carried little extra information (Deep Learning Based Detection of Acute Aortic Syndrome in Contrast CT Images). The lung arteries branch too much to straighten, and on the PE benchmark ordered aggregation beat this kind of pooling (Seeking an Optimal Approach for Computer-Aided Pulmonary Embolism Detection). We still run it as a baseline.

Why not just use a lean 3D CNN like DMFNet? This is the most serious threat. DMFNet reaches 27 GFLOPs and 0.019 s per brain MRI volume (3D Dilated Multi-Fiber Network for Real-time Brain Tumor Segmentation in MRI). Two caveats apply to that figure:

  • brain MRI volumes are far smaller than full-resolution chest CT;
  • DMFNet's model is trained from scratch, which gives up the ImageNet and self-supervised transfer that the PE benchmark found to matter.

The globality ablation and the DMFNet baseline together settle this question at matched latency. If the 3D CNN wins on PE-negative specificity, we will report that and drop the attention claim.

Why not just run a 3D Mamba over the whole volume? It has linear cost, but it must flatten the volume. EccoMamba shows that flattening breaks continuity and introduces directional bias (EccoMamba), and no 3D fix exists in the file. We include it as the operator-swap variant rather than argue the point in the abstract.

Proposed Experiments

Main experiment. Train on the RSNA PE Detection Challenge data (7,279 exams, more than 1.5 million slices) using the official split protocol. Report three metrics:

  • exam- and slice-level AUC;
  • specificity and false alarms per 100 negative exams at 90% and 95% sensitivity;
  • AUC for each auxiliary label.

Measure end-to-end wall-clock time per exam on one GPU and on CPU. The timing covers all methods at fixed batch size and includes loading and preprocessing.

External transfer. Apply all models without retraining to INSPECT (23,248 CT pulmonary angiography studies whose labels come from report text) to test transfer to another institution. The only number Lacuna reports there is 0.761 AUROC for the dataset's best multimodal model, which also uses electronic health records. That is a different setting, so we treat it as context, not a target.

Localization. Score the coarse localization maps on CAD-PE with its free-response protocol, against 75% sensitivity at 2 false positives per scan. CAD-PE has no negative scans, so it cannot measure false alarms. INSPECT negatives serve that purpose.

Workload simulation. Replay test exams in arrival order with reading times drawn from a fixed per-exam distribution. Compare median time-to-read for PE-positive exams, and the number of negatives pushed ahead of positives, across first-in-first-out ordering, the GRU pipeline, and our model.

Decisive checks. The proposal succeeds only if three conditions all hold:

  • the full model beats both the pooling and the globality ablations on PE-negative specificity at 95% sensitivity;
  • its gain on the ventricle-ratio and laterality labels exceeds its gain on the overall PE label;
  • latency stays within the stated budget.

A uniform small AUC bump without this pattern would mean that the extra parameters, not the global 3D receptive field, did the work.