Filamentation Speckle and the Sample Cost of Classical Superbunching

Ghost imaging builds a picture of an object without a camera looking at it. A random light pattern illuminates the object, a single light meter (a "bucket detector") records how much light gets through, and a separate camera records the pattern itself. Correlating the two signals over many random patterns reveals the object. With ordinary thermal-like light, the reconstructed image can never exceed 33% visibility. Recent work breaks that limit with classical light by making the patterns "superbunched", meaning bright flashes are much more likely than ordinary thermal statistics allow. The same work notes the cost: the more extreme the fluctuations, the more patterns are needed before the image emerges from noise. Nobody has measured how fast that cost grows. So it is unknown whether superbunching ever improves the quantity that matters when measurements are scarce, which is image quality per measurement. Visibility alone can be raised trivially by subtracting background.

This note proposes to answer that question with a closed-form sample-cost law and an unusual light source. The source is the breakup of an intense femtosecond laser beam into many random filaments inside a transparent solid. Multi-filamentation is normally treated as a failure mode. Here each laser shot becomes a fresh, high-power, broadband random pattern whose statistics can be tuned by pulse energy and beam shaping. The central claim is that a source's usefulness for sample-limited correlation imaging is set by its fourth intensity moment relative to the square of its second, not by $g^{(2)}(0)$. A filamentation source is worth having only if its tail can be tuned to sit at the favorable end of that tradeoff.

Core Claim

Correlation imaging estimates a covariance between the bucket signal and each reference pixel. The signal grows with the normalized second moment $g^{(2)}(0) = \langle I^2\rangle/\langle I\rangle^2$. The estimator's variance grows with the normalized fourth moment $g^{(4)}(0) = \langle I^4\rangle/\langle I\rangle^4$.

For the cascaded rotating-ground-glass source, each stage multiplies the intensity by an independent exponential factor. A product of $N$ independent unit exponentials has normalized moments $(k!)^N$. That gives $g^{(2)}(0)=2^N$, matching the scaling reported in High visibility temporal ghost imaging with classical light, and $g^{(4)}(0)=24^N$. To leading order, the number of patterns needed to reach a fixed contrast-to-noise ratio (CNR) $C$ is

$$ M_{\text{req}}(C) \approx C^2\,\frac{g^{(4)}(0)}{\left(g^{(2)}(0)-1\right)^2} \;\sim\; C^2\,6^N , $$

with the second form specific to cascaded exponentials. This is a first-order estimate that ignores cross-pixel terms and detector noise. Those corrections are part of the work.

The estimate predicts that each added ground-glass stage costs roughly six times more samples while visibility improves only sub-linearly. That would explain why the cited study needed $10^5$ simulated iterations. It also implies that heavy tails are a net loss at fixed sample budget unless a source achieves a larger $g^{(2)}$ for a given $g^{(4)}$ than cascaded exponentials do. Kerr-driven filament breakup has two features that could change this ratio. The number of filaments saturates, and intensity is clamped inside each filament by plasma defocusing. Both bound the tail. That is the hypothesis this note tests.

Research Program

The first strand is analytical. We will extend the leading-order law above to the background-subtracted (differential) estimator and to finite object transmission. We will add detector shot noise, so that $M_{\text{req}}$ is predicted for any source from its measured moment ratios. The output is a single design chart. On it, each candidate source is a point in the plane of $g^{(2)}(0)$ against $g^{(4)}(0)/(g^{(2)}(0)-1)^2$, with contours of constant samples-to-target. This treats statistical sensitivity the way rare-event searches do, as significance per unit exposure. In the EXO-200 search, Search for Neutrinoless Double-β Decay with the Complete EXO-200 Dataset gained sensitivity by raising signal efficiency from 80.8% to 96.4% rather than by adding exposure. Our analog is raising the information carried by each pattern rather than collecting more patterns.

The second strand is simulation. We will simulate femtosecond propagation in a bulk Kerr medium with a nonlinear-Schrödinger or unidirectional propagation model. Input beams will carry controlled random perturbations, following the noise-seeding picture of Statistical analysis of noise-induced multiple filamentation, which showed that filament number and location are statistical functions of input noise. We will scan the ratio of beam power to the critical power for self-focusing, and the input noise amplitude. We will also scan a Gaussian-to-Bessel mixing parameter. Bessel beams suppress breakup altogether, as shown in Generation of extended plasma channels in air using femtosecond Bessel beams, where energy up to 14.5 mJ raised plasma density in a single channel rather than splitting it. A partial Bessel component therefore gives a continuous knob from "no breakup" to "full breakup."

From each simulated shot ensemble we extract the output pattern statistics. These are the pixel moments, the spatial correlation length, and the fraction of energy in filaments. We then place the source on the design chart. The simulation has a known weakness: the same Bessel-beam study found high-frequency axial plasma oscillations in simulation that experiments did not show. So simulated tail statistics are treated as a prior to be checked, not as a result.

The third strand is experimental. An amplified femtosecond laser is focused into a bulk crystal above the breakup threshold. Its exit face is imaged onto a beam splitter. One arm goes to a reference camera recording each shot's filament pattern, which takes the place of the ground-glass speckle. The other arm passes through the object to a bucket photodiode. Shot-to-shot pattern variation supplies the randomness, so no moving diffuser is needed, and none of the cascaded-scattering attenuation that blocked physical $N=6$ in the temporal ghost-imaging study arises. Neutral-density stages before the cameras keep the reference and bucket detectors linear despite the high pulse energy.

Baselines

The naive reference point is conventional correlation ghost imaging with Gaussian pseudothermal light from a single rotating ground glass. It has $g^{(2)}(0)\approx 2$ and is run with the identical camera, bucket detector, objects and number of patterns. The same light with a background-subtracted (differential) correlation estimator is the "do nothing clever" competitor that matters most. It removes the background that caps raw visibility, so it tests whether superbunching buys anything beyond what subtraction already gives. Beating it means a lower measured $M_{\text{req}}$ at equal CNR, not a higher visibility.

The strongest existing classical method on the visibility question is the cascaded rotating-ground-glass source of High visibility temporal ghost imaging with classical light. It reports visibility rising from (4.7 ± 0.2)% at $N=1$ to (75 ± 8)% at $N=6$, the latter in simulation. We will build the physically realizable stages, $N=1$ to $3$, and simulate higher $N$. Two-stage glass has a measured $g^{(2)}(0)=3.66\pm0.02$ in Superbunching pseudothermal light. The filamentation source beats this baseline if, at matched $g^{(2)}(0)$, it reaches target CNR in fewer patterns. Equivalently, it must sit below the cascaded-exponential curve on the design chart.

For learned reconstruction we use a self-supervised physics-consistency reconstructor in the style of Large model enhanced computational ghost imaging. That work minimizes the mismatch between predicted and measured bucket signals without labeled data. It reports about 31–32 dB PSNR on 640×640 simulated targets at an effective 2.4% sampling ratio, outperforming differential ghost imaging, compressive sensing and UNet. A 1.4-billion-parameter model exceeds our budget. We therefore train a smaller model of identical design with the same tuning budget separately for each source, and compare sources under the same reconstructor rather than claiming to beat GILM. Beating here means higher PSNR at the same pattern count when the only change is the illumination source.

The key ablation isolates heavy tails from spatial structure. We rank-transform each filamentation pattern so its pixel histogram becomes exponential, meaning thermal, while preserving the spatial arrangement. This matters because 0.8% Nyquist computational ghost imaging via non-experimental deep learning showed that correlated "pink noise" patterns alone enable 0.8%-of-Nyquist recovery. Any gain from filamentation could therefore come from spatial correlation rather than superbunching.

Why not just…?

Why not just collect more patterns with ordinary thermal light and subtract the background? This is the most serious threat. If our law is right and the filamentation source lands near the cascaded-exponential curve, it will win outright, and superbunching will be shown to be a visibility cosmetic for sample-limited imaging. The differential-estimator baseline is designed to settle this. We will report that outcome as the main result if it occurs, because it would redirect a line of work that currently optimizes visibility.

Why not just use entangled photon pairs? Entangled sources exceed classical visibility bounds, but they operate at single-photon flux. Fluorescence lifetime Hong-Ou-Mandel sensing frames attenuated classical light as capped at 50% dip visibility, which is precisely a visibility argument. Our question is per-sample information at high flux, and there the photon-starved quantum source is a different operating regime rather than a competitor. We do not claim to beat it on visibility.

Why not just program heavy-tailed patterns on a spatial light modulator? For low-power, narrowband, continuous-wave imaging, this probably works as well or better, since any statistics can be programmed. We include programmed patterns with matched moments as a simulation control. Our claim is restricted to the regime where modulators fail: millijoule femtosecond pulses and broadband supercontinuum. There, a modulator cannot handle the power or bandwidth, and filament breakup generates the patterns in the light itself. If matched programmed patterns and filamentation patterns give equal $M_{\text{req}}$, the result supports the moment law as the whole story.

Why not just apply a standard network to thermal light? The GILM study reports that UNet needed more than twice the measurements of its large model and that plain CNNs failed at 1.94% sampling. The pink-noise study found white-noise illumination failed at 0.8% Nyquist. Reconstruction capacity is therefore a real lever. We hold it fixed across sources so that the comparison measures illumination statistics alone.

Proposed Experiments

The decisive first check validates the sample-cost law on sources whose statistics we control. Using ground-glass stages $N=1$ to $3$ physically and $N$ up to 6 in simulation, we image the USAF 1951 resolution target and binary 320×320 targets. We measure CNR against pattern count $M$ and fit $M_{\text{req}}$. The law predicts roughly sixfold growth per stage. A growth near the fourfold rate implied by naive $g^{(2)}$-squared reasoning would falsify it.

The second check characterizes the filamentation source across the power, noise and Bessel-mixing scans. We report $g^{(2)}(0)$, $g^{(4)}(0)$ and spatial correlation length per setting. Every claim about the source's statistics comes from this measurement; no figure for filamentation $g^{(2)}$ appears on Lacuna.

The third check runs ghost imaging with the filamentation source on USAF, MNIST-style digits and the 320–640 pixel grayscale targets. It also includes a heated-airflow path modeled on the turbulence benchmark of Attention-enhanced computational ghost imaging. For each, we compare $M_{\text{req}}$ and fixed-budget PSNR against the thermal, differential and cascaded baselines, and against the rank-transformed ablation.

The proposal succeeds if two things hold. First, some filamentation setting lies measurably below the cascaded-exponential curve, with error bars from repeated shot ensembles. Second, that advantage survives the rank-transform ablation. It fails informatively if no setting does: that outcome would show classical superbunching cannot reduce sample cost in correlation imaging, whatever its visibility.