NeurIPS 2026Coming to NeurIPS?Explore papers, orals & directions

Do Radiologists Draw Different Nodule Contours Because They See Different Findings?

When several radiologists outline the same lung nodule, their outlines differ, and current models of this disagreement can reproduce it without explaining it. They learn a small abstract code per annotator, a handful of numbers that make one rater's masks "bigger" or "looser," but no axis of that code means anything a clinician could check. This proposal tests a concrete, falsifiable hypothesis: much of the variation in where a radiologist draws a boundary is carried by what that radiologist judged the nodule to look like, for example how spiculated its margin is, whether it is solid or ground-glass, and how subtle it is. The LIDC-IDRI lung CT collection makes this testable, because each of its four readers per nodule recorded both a contour and their own scores on a set of radiological visual characteristics. We build a segmentation model whose rater-specific behavior is driven by that rater's own concept scores, with a small residual latent code for anything left over. We then measure how much of the inter-rater spread the concepts account for, and whether editing a single concept score moves the predicted contour the way the corresponding reader's real contour moved.

If the hypothesis holds, disagreement stops being an opaque heatmap and becomes something a clinician can read: "your contour is wider than your colleague's because you called the margin ground-glass and they called it solid." If it fails, and concepts explain little beyond an abstract latent, that is also worth knowing. It would mean the disagreement lives in motor or threshold habits rather than in perception, and that interpretability tools aimed at clinical concepts are looking in the wrong place.

Core Claim

Rater-specific segmentation variation can be decomposed into a part explained by that rater's stated clinical concept judgments and an unexplained residual. A segmentation model conditioned on per-rater concepts should match the multi-rater distribution nearly as well as a model with a free per-rater latent code. Its conditioning should also be causally meaningful: changing one concept score should change the predicted mask in the anatomically expected region, and swapping one reader's scores for another's on the same nodule should move the prediction toward that other reader's actual contour.

Relation to Prior Work

Three latent-variable models of rater disagreement motivate the gap and supply the probabilistic machinery. Pionono embeds each rater as a Gaussian in an 8-dimensional latent space, separating systematic bias (the mean) from inconsistency (the variance). The Latent Doctor Model infers rater style from a support set using a conditional variational autoencoder, an encoder–decoder that learns a probabilistic code. Liu et al. sample segmentations from a 6-dimensional latent regularized by image reconstruction. All three show that disagreement is structured, and none ties a latent axis to a clinical finding. We keep their residual-latent design but put named, rater-reported concepts in front of it, so the abstract code only has to absorb what the concepts cannot.

Concept bottleneck models route predictions through human-readable intermediate concepts. Concept Bottleneck Models introduced the idea, and CCBM adds discovered "unknown" concepts and reports Derm7pt concept-detection AUC of 93.96% while staying within 1–2% of black-box accuracy, including on LIDC-IDRI. These models predict one consensus concept vector per image and one consensus label. We differ in using concepts as a per-rater variable that explains why labels differ. CCBM's known-plus-unknown split is the method we borrow for the concept-plus-residual decomposition.

Two interpretability results constrain the design. Arun et al. show that saliency maps fail weight-randomization and repeatability tests on medical localization, with the best method reaching 0.224 AUPRC against a U-Net's 0.404 on pneumothorax. That rules out explaining disagreement with Grad-CAM-style attributions. Med-SegLens decomposes segmentation-network activations with sparse autoencoders and steers them, but it compares models across patient populations, not across raters of the same image, and its steering strength is hand-tuned. Our concept edits have a natural scale: the rater's own ordinal score.

Two disagreement-aware methods are closest in spirit and still leave the "why" open. MRNet turns reconstructed rater masks into uncertainty maps that serve as attention. Confidence Contours shows that clinicians prefer nested definite/possible boundaries to continuous heatmaps and that this format cuts representation error on LIDC by 19.9%. Both localize doubt but do not attribute it to findings. Our counterfactual edits supply that attribution, and the Min/Max contour format is a natural output of them. DiFF explicitly lists the interpretability of its diagnosis-calibrated features against clinical biomarkers as unexplored. Our concept audit is one way to fill that gap, though we do not depend on DiFF.

Research Program

The work has three stages, and the first is deliberately cheap.

In stage one we fit a within-nodule statistical model before any neural network. For every pair of readers on the same nodule, we regress the difference in their contour area, and the symmetric-difference region split into rim versus core, on the differences in their concept scores. Nodule fixed effects remove image difficulty from the comparison. This stage tells us which concepts matter for size. It sets a floor any deep model must justify itself against.

In stage two we train the concept-conditioned segmentation model. The model is a 2D/2.5D U-Net that predicts reader $r$'s mask from the image $x$, the reader's concept vector $c_r$, and a residual latent $z_r$ under a KL penalty, in the style of the latent models above. Both $c_r$ and $z_r$ modulate the decoder through feature-wise scaling. The core quantity is the share of disagreement the concepts carry:

$$S = \frac{\mathrm{GED}_{\varnothing} - \mathrm{GED}_{c}}{\mathrm{GED}_{\varnothing} - \mathrm{GED}_{z}}$$

Here GED is the generalized energy distance between predicted and true multi-reader mask sets on held-out nodules. $\mathrm{GED}_{\varnothing}$ is a model given no rater information. $\mathrm{GED}_{c}$ conditions on concepts only. $\mathrm{GED}_{z}$ uses a free latent fitted to each reader's mask, which is the information-rich upper reference. $S$ near 1 means concepts explain almost everything the free latent captures. We also report the KL usage of $z_r$ in the combined model, as a second measure of what the concepts leave unexplained.

In stage three we test whether the concept conditioning is causal rather than merely correlational. In the swap test, for two readers on the same nodule, we feed reader A's concepts with the image and check whether the predicted mask moves toward A's real mask and away from B's. In the single-concept edit test, we change one score at a time and record where the mask changes. Margin and spiculation edits should move the outer rim, texture edits should change ground-glass inclusion, and calcification edits should do little. A thoracic radiologist, blinded to which concept was edited, judges which finding each edit-induced mask change corresponds to. Edits are turned into Min/Max contours to match the format clinicians preferred in Confidence Contours.

At test time on new images, rater concepts are unknown. A concept predictor in the CCBM style outputs a distribution over per-reader scores, and sampling from it yields concept-labelled segmentation hypotheses: "if read as spiculated, this contour."

Baselines

The naive reference is a U-Net trained on the majority-vote mask, plus the same network with test-time dropout sampling to produce a distribution. It shows how much any rater-aware modeling helps. On QUBIQ brain growth, the corpus reports dropout at 0.5083 continuous Dice against 0.5372 for latent variational inference (Liu et al.), so we expect it to be clearly beaten on distribution metrics.

The strongest competitor is a free-latent multi-rater model in the Pionono / Probabilistic U-Net family with the same backbone. It is the model our $\mathrm{GED}_z$ reference represents, and it is the state of the art at reproducing disagreement. We do not expect to beat it on GED, because it fits each mask directly. The bar is to come within a small margin (the target is $S \geq 0.6$) while adding causal, nameable explanations it lacks. For reference numbers: Pionono reports Cohen's κ of 0.758 on Gleason 2019, and OMBA-UNet reports better Q-score and GED than PHiSeg and Probabilistic U-Net on LIDC-IDRI. However, no reported LIDC GED value was found on Lacuna for these methods, so we rerun them ourselves. Every model uses identical splits by patient, the same backbone, the same augmentation, and the same hyperparameter-search budget, with five seeds each.

The key ablation replaces each reader's own concept scores with the nodule's mean concept scores, or with scores predicted from the image. This keeps the conditioning pathway but removes rater-specific perception. If it matches the per-rater model, the concepts are only describing the image, not explaining the disagreement, and the core claim fails. A second ablation shuffles concept vectors across readers within a nodule. The swap test is valid only if the real assignment clearly beats the shuffled one.

The post-hoc competitor is a linear and small-MLP probe that predicts concept scores from a trained Pionono-style model's latent codes. If those latents already align with concepts, a post-hoc probe gives similar interpretability for free.

Why not just…?

Why not just regress disagreement on concept differences and skip the deep model? This is a real threat for the narrow question of which concepts correlate with larger contours, and stage one runs exactly this. Regression cannot say where in the image a concept changes the boundary. It cannot produce a reader-specific contour for a new nodule, and it cannot be checked with swap counterfactuals against real masks. If the stage-one regression already explains most of the area variance and the spatial edit tests add nothing a radiologist finds informative, we will report the simpler analysis as the result.

Why not just probe an existing free-latent model's codes for concepts after training? Post-hoc alignment is cheaper, and if probes recover concepts with high accuracy, the free latent is already interpretable. Even then, a probe would not make the latent's effect on the mask attributable to a concept, because the latent axes can mix several factors at once. The probing baseline measures this directly. Comparing its swap-test performance, using probe-guided latent moves, against direct concept conditioning will show whether built-in conditioning is needed.

Why not just use saliency maps over the disagreement region? Arun et al. found that 5 of 8 saliency methods on a segmentation task were insensitive to weight randomization, so a heatmap over the ambiguous rim would likely show edges rather than reasons. We include Grad-CAM over the predicted inter-reader region only as a sanity check, run through the same randomization test as our concept edits, which must pass it.

Why not just apply sparse-autoencoder diffing across per-rater models, as Med-SegLens does across populations? On LIDC this approach runs into data limits: each reader contributes few nodules, so per-rater models would be weak, and discovered latents would still need naming afterward. The rater-reported concepts are already named and already individual. We treat sparse-autoencoder analysis of our trained model's residual pathway as a follow-up for interpreting whatever the concepts miss.

Proposed Experiments

The primary benchmark is LIDC-IDRI, using nodules with four reader contours and the per-reader characteristic scores, split by patient. Metrics are GED, the explained share $S$, per-reader Dice when conditioned on that reader's concepts, and the Confidence Contours representation error for the derived Min/Max contours.

The decisive checks are three. The per-rater model must beat the mean-concept and shuffled-concept ablations on GED with non-overlapping seed intervals. In the swap test, the predicted mask must move toward the donor reader's real mask in a clear majority of reader pairs. Blinded radiologist identification of single-concept edits must be well above chance.

A secondary check with weaker supervision tests whether the conclusions transfer to ISIC lesion segmentation paired with Derm7pt-style concepts predicted by a CCBM-type model. Because those concepts are not reported per rater, this check can test only the image-level version of the claim. We report it as a limitation, not as confirmation.