A 10-second electrocardiogram (ECG) taken between episodes of intermittent atrial fibrillation usually looks normal, so short episodes that cause no symptoms go unrecorded. This note asks whether a recent episode leaves a slowly fading "wake" in the heart's beat-to-beat behaviour, and whether the shape of that wake can tell us how long ago the episode ended. The modelling idea comes from fractional-order systems, meaning dynamical systems whose rate of change depends on a power-law-weighted average over their whole past rather than only on the present state. For such systems, a short observation window is shaped by a hidden "history function." A standard result shows that this history can be compressed into a finite set of initial states.
The core observation is simple. If recovery after an episode is exponential, as in any ordinary (integer-order) linear model, then a short window cannot distinguish "a small episode recently" from "a large episode long ago." The time since the episode is mathematically unrecoverable. If recovery follows a power law, that time changes the curvature of the transient and becomes recoverable in principle. We propose to fit short sinus-rhythm windows with a fractional model whose unknown history is parameterized as a past episode, then read off the estimated time-since-episode and episode size. We will test whether this recovers annotated episode timing and flags patients with unseen episodes better than deep sinus-rhythm classifiers.
Core Claim
Consider a per-beat physiological series $y(t)$ observed on a window $[0, T]$, such as RR intervals (time between successive heartbeats) or beat-level P-wave duration, recorded after an unobserved episode that ended at time $-\tau$. Let $A$ be the episode's effect on that series.
Under an integer-order relaxation with time constant $\theta$, the residual transient is
$$y(t) - y_{ss} = A\,e^{-(t+\tau)/\theta} = \big(A e^{-\tau/\theta}\big)\,e^{-t/\theta},$$
where $y_{ss}$ is the resting level. Here $\tau$ is absorbed into the amplitude and cannot be identified from any window.
Under fractional relaxation of order $\alpha$, the free response to a past block input has a power-law tail, roughly $y(t)-y_{ss} \approx A\,(t+\tau)^{-\beta}$ with $\beta$ set by $\alpha$. Its local log-log slope is $-\beta\, t/(t+\tau)$, which depends on $\tau$ itself.
It follows that $\tau$ should be identifiable when it is comparable to or shorter than the window $T$. Identifiability should degrade as $\tau \gg T$, where the transient flattens into a pure power law.
The claim is therefore twofold. First, the explicit initialization function, not merely a fractional order or a memory feature, is the quantity that carries information about missed events. Second, whether the wake is power-law or exponential is an empirical question the program settles, with a stated way to fail.
Relation to Prior Work
Methods we reuse. Orjuela, Malti, Moze and Ijspeert Prise en compte des conditions initiales lors de la simulation de fonctions de transfert non entières show that Oustaloup's band-limited pole–zero synthesis maps a fractional operator's infinite history onto a finite internal state vector. Simulation accuracy improves as more of these initial states are kept. We reuse this machinery, but invert it: instead of simulating from known initial states, we estimate them, constrained to be generated by a parameterized past episode. Their work is purely synthetic. It also notes that standard fractional solvers do not accommodate finite initial-state representations, which we must handle ourselves.
Motivation from system identification. Malti et al.'s Tutorial on system identification using fractional differentiation models and System identification using fractional models: State of the art found that ignoring pre-observation history biases identified parameters. On a heated aluminum rod, a 3-parameter fractional model beat a 12-parameter rational model (NMSE about $2\times10^{-4}$ versus $6\times10^{-4}$). They leave estimating the history function from finite noisy data open, and it is precisely our target.
Constraining work. Xu et al.'s Convergence Analysis of Iterative Learning Control for Initialized Fractional Order Systems learns the initialization across repeated identical trials. That assumption fails for non-repetitive telemetry, so we estimate the initialization per window. Zhang, Gupta and Bogdan's A Sampling Complexity-aware Framework for Discrete-time Fractional-Order Dynamical System Identification makes order estimation a least-squares problem using many short trajectories from varied initial conditions. We borrow its basis-regression idea for estimating $\alpha$ at the population level, then fix $\alpha$ when inverting individual windows, to tame the non-convexity that Malti et al. warn about.
Closest prior art. Bogdan et al.'s Fractional dynamics foster deep learning of COPD stage prediction uses multifractal and fractional-coupling features from long stationary recordings of 72,000+ points to reveal underdiagnosed chronic obstructive pulmonary disease (COPD) stages. It characterizes a stationary memory signature. We instead estimate a non-stationary transient left by a discrete past event, from short windows, and output an event time.
The sinus-rhythm classifiers we compete with. Deep Learning of Electrocardiograms in Sinus Rhythm From US Veterans to Predict Atrial Fibrillation, Evaluating the Risk of Paroxysmal Atrial Fibrillation in Noncardioembolic Ischemic Stroke Using Artificial Intelligence-Enabled ECG Algorithm, Identifying the presence of atrial fibrillation during sinus rhythm using a dual-input mixed neural network with ECG coloring technology and A deep learning method for beat-level risk analysis and interpretation of atrial fibrillation patients during sinus rhythm all show that sinus-rhythm ECGs carry risk signal. They treat each strip or beat as a memoryless snapshot and output a risk score, not an estimate of when a missed episode happened.
Research Program
The model. Each subject's sinus-rhythm per-beat series is modelled as a stationary resting fluctuation, captured by a low-order noise model, plus a Caputo-form fractional relaxation. We use the Caputo form because it keeps integer-order initial values that have physical meaning. The relaxation is driven by a history function consisting of a block episode of amplitude $A$ and duration $d$ that ended $\tau$ before the window.
Making the fit tractable. Oustaloup synthesis over a band chosen to span beat-scale to hours-scale dynamics turns the relaxation into a finite linear system. Its initial state vector is then a deterministic function of $(\alpha, \lambda, A, d, \tau)$, where $\lambda$ is the relaxation rate. Fitting a window reduces to a low-dimensional nonlinear least-squares problem with $\alpha$ fixed from a population estimate. We solve it with a multi-start search over $\log\tau$ and report profile-likelihood intervals, so that unidentifiable fits are visible rather than hidden.
Synthetic validation. Before touching ECG data, we simulate this generative model with realistic noise and ectopic-beat contamination. The goal is to map where $\tau$ is recoverable as a function of $T/\tau$, $\alpha$, and signal-to-noise ratio, and to check the predicted collapse of identifiability as $\alpha \to 1$.
Clinical adaptation. Ectopic beats would masquerade as transients. We remove them first with the rule-based premature-beat rejection of Premature Beats Rejection Strategy on Paroxysmal Atrial Fibrillation Detection, which rejects 99.5% of single premature beats.
Data. The empirical work uses CPSC 2021, whose 1,436 ambulatory recordings from 105 subjects include annotated paroxysmal AF onsets and offsets, and uses MIT-AFDB as an external set. Annotated offsets give ground-truth $\tau$ for every sinus window that follows an episode.
Baselines
Naive reference. For timing, the reference predicts the training-set median $\log\tau$ for every window. For patient identification, it uses beat-rate and RR-variability summary statistics fed to logistic regression. Any method must clear this bar to show that it reads more than "this person's rhythm is irregular."
Strongest existing method: Net1D with beat-level fusion. This is the beat-level CNN with 150-beat decision fusion of Lei, Hong et al. A deep learning method for beat-level risk analysis and interpretation of atrial fibrillation patients during sinus rhythm. It is the strongest competitor because it was built for exactly our patient-level question on exactly our dataset. It reports a single-beat AUC of 0.7314 and a 150-beat fused AUC of 0.7591 on CPSC 2021 (accuracy 0.6887). We will retrain it on our subject-level cross-validation folds with an equal hyperparameter-search budget. We will also train a regression head on it for $\tau$, for which no reported result was found on Lacuna. Beating it means one of two outcomes. The fractional-initialization features alone could match 0.7591 with orders of magnitude fewer fitted quantities. Alternatively, adding our features to Net1D could produce a statistically significant AUC gain across folds. For timing, it means lower error in $\log\tau$ than a Net1D regressor given the same window.
Integer-order initialization model. This is the integer-order counterpart of our method: the same block-history inversion, but with a sum of one to $K$ exponential modes whose poles are freely fitted. $K$ is chosen so the parameter count matches or exceeds ours. This isolates whether power-law memory, rather than explicit history estimation, is what matters.
Ablation of the key ingredient. The zero-history fractional model estimates $\alpha$ and $\lambda$ but assumes the heart was at rest before the window. This removes exactly the initialization function.
Stationary-memory feature baseline. Following the COPD work of Bogdan et al., we extract multifractal detrended fluctuation features from the same windows and feed them to the same small classifier. This tests whether a stationary memory signature already suffices.
Why not just…?
Why not just train a larger deep network on longer windows? High-capacity sinus-rhythm models reach an AUC of 0.86–0.93 on large cohorts Deep Learning of Electrocardiograms in Sinus Rhythm From US Veterans to Predict Atrial Fibrillation. A well-tuned network might also learn transient curvature implicitly. This is a real threat for patient-level AUC, and we do not claim to beat it at CPSC scale. Our distinctive output is an event time with an uncertainty interval that goes to infinity where the physics says it should. The Net1D timing regressor tests whether a network can match that. If it does, and also produces calibrated intervals, our contribution shrinks to interpretability.
Why not just fit a multi-exponential integer-order model? With enough modes, a sum of exponentials can approximate a power law over a finite band. Oustaloup's construction is literally such a sum with log-spaced poles, so this is the most serious alternative. The difference is parsimony and identifiability: with free poles, $\tau$ is confounded with mode amplitudes, whereas the fractional parameterization ties all modes to a few quantities. The matched-parameter integer baseline settles it on held-out windows. If it matches us on $\tau$ error, we will report that the benefit comes from history estimation rather than fractional order, which is still a finding about initialization.
Why not just use detrended fluctuation or multifractal features? These summarize stationary long memory and succeeded for COPD staging Fractional dynamics foster deep learning of COPD stage prediction. By construction, however, they average over the window and carry no notion of a transient anchored at a past time. They should flag PAF patients but fail to order windows by $\tau$. The within-patient timing test checks exactly this.
Why not just use Neural Laplace for history-dependent dynamics? Neural Laplace: Learning diverse classes of differential equations in the Laplace domain encodes trajectories into a latent initial condition and handles delay systems. It is tested only on synthetic physics and has no explicit event-time parameter. We include it as a secondary timing baseline on the synthetic benchmark, where data are plentiful. We expect it to be data-hungry at CPSC's 105-subject scale, but that is an expectation to test rather than evidence.
Decisive Checks
Existence of the wake. The first check is pre-registered and can end the project. We align all post-episode sinus beats in CPSC 2021 and MIT-AFDB by time since annotated offset and average the RR and P-wave series across episodes. If no systematic transient exceeds between-subject variability, we stop.
Shape of the wake. If a transient exists, we compare exponential and power-law fits of the aligned curve by held-out likelihood. This directly answers whether integer-order models are adequate here.
Timing recovery. The main test estimates $\tau$ from single short windows. We measure rank correlation and error in $\log\tau$ between estimated and annotated time-since-offset, stratified by $T/\tau$, and check that accuracy degrades along the curve predicted by the synthetic study.
Patient identification and calibration. We then compare patient-level AUC against Net1D's 0.7591 under shared folds. Finally, we check calibration of the profile-likelihood intervals, meaning whether nominal 80% intervals contain the true $\tau$ about 80% of the time.
References
- Prise en compte des conditions initiales lors de la simulation de fonctions de transfert non entières
- Tutorial on system identification using fractional differentiation models
- System identification using fractional models: State of the art
- Convergence Analysis of Iterative Learning Control for Initialized Fractional Order Systems
- A Sampling Complexity-aware Framework for Discrete-time Fractional-Order Dynamical System Identification
- Fractional Dynamics Foster Deep Learning of COPD Stage Prediction
- Deep Learning of Electrocardiograms in Sinus Rhythm From US Veterans to Predict Atrial Fibrillation
- Evaluating the Risk of Paroxysmal Atrial Fibrillation in Noncardioembolic Ischemic Stroke Using Artificial Intelligence-Enabled ECG Algorithm
- Identifying the presence of atrial fibrillation during sinus rhythm using a dual-input mixed neural network with ECG coloring technology
- A deep learning method for beat-level risk analysis and interpretation of atrial fibrillation patients during sinus rhythm
- Premature Beats Rejection Strategy on Paroxysmal Atrial Fibrillation Detection
- Neural Laplace: Learning diverse classes of differential equations in the Laplace domain