Contralateral Residuals as Boundary Evidence for Scribble-Supervised Tumor Segmentation

When a radiologist cannot see where a tumor ends because it has the same brightness as the muscle or brain tissue around it, they often look at the same spot on the patient's other side. If the left side looks different from the mirrored right side, something is there. This proposal turns that habit into a training signal for a setting where experts provide only a few quick strokes ("scribbles") inside and outside the tumor rather than tracing its full outline. Methods that learn from scribbles must guess where the unlabeled boundary lies. Today they guess from local brightness changes, and at low-contrast edges those changes are missing. We propose to replace brightness change with left–right disagreement as the cue that tells the label expansion where to stop.

Concretely, a small network learns without any labels to predict each image region from its mirror-image counterpart on the other side of the body. The regions it predicts badly, its residual map, mark patient-specific abnormality. We use changes in this residual, rather than changes in raw intensity, to decide how far sparse scribbles spread into full pseudo-masks. A standard 3D segmenter is then trained on those masks. The claim is narrow and testable. On paired anatomy with unilateral low-contrast tumors, contralateral residuals recover a measurable part of the boundary-concentrated gap between scribble and dense supervision. They should do so where intensity-based expansion leaks and where simply giving the network a flipped copy of the image does not help.

Core Claim

The strongest scribble baseline in the file is a plain 3D nnU-Net trained with a partial loss, meaning a loss computed only on scribbled voxels. Gotkowski et al. (2024) and Gotkowski et al. (2025) showed that across the seven-task ScribbleBench it reaches mean Dice 0.813, against 0.856 with dense labels. Specialized pipelines collapse outside cardiac data: ShapePU falls to 0.369 and CycleMix to 0.559, and brain-tumor Dice drops to near zero for some methods. These results constrain the proposal. Any added machinery must beat nnU-Net with partial loss under that paper's own protocol, or it is not worth adding.

The motivating evidence for bilateral comparison comes from dense supervision. SATS by Li et al. (2025) runs a Siamese network on a CT volume and its flip, with a margin loss that separates asymmetric tumor features from symmetric healthy ones. It lifts external SegRap2023 nasopharyngeal tumor Dice from about 62.4% (nnU-Net, implied by the reported +4.4 gain) to 66.80%. DRT-M3D by Zhou et al. (2025) feeds flipped left and right breasts to the network as one sequence and improves non-contrast CT lesion Dice from about 0.61 to about 0.66. Both use full 3D masks.

The weak-label methods that do expand labels use intensity affinities. Can et al. (2018) use random walk plus DenseCRF with dropout-based uncertainty. Ji et al. (2019) use graph cut plus a DenseCRF loss on BraTS. Agarwal et al. (2020) use GrabCut from RECIST lines. The file documents that these expansions bleed at low-contrast borders. Our contribution sits in the gap between these two groups. We do not propose another bilateral architecture. We propose a label-free bilateral signal that goes into the one place where weak supervision is known to fail, the affinity that governs label expansion.

Research Program

The first component is a contralateral predictor. Each volume is rigidly aligned to its mid-sagittal plane. A lightweight 3D network $f$ takes the mirrored patch at location $p'$ together with a coarse context patch and predicts the patch at $p$. It is trained on all training volumes, with no masks, using a robust loss. Two mechanisms keep lesions from contaminating the fit. First, voxels covered by foreground scribbles are excluded from the loss, which the scribble setting allows. Second, a trimmed loss drops the worst-fitting fraction of voxels, so unlabeled lesion voxels act as outliers.

Because $f$ is trained on many patients, it can absorb systematic, benign left–right differences such as residual tilt and normal lateralization. This is the failure mode that Fineide et al. (2022) and Liang and Han (2021) identify for raw subtraction. It plays the filtering role that SATS assigns to a projection head trained with dense labels, but here it needs no labels. The residual $r(p)$ is the normalized prediction error at each voxel.

The second component is residual-aware label expansion. Scribbles are spread with a random walk whose edge weights between neighboring voxels $i$ and $j$ are

$$w_{ij} = \exp\!\left(-\beta\,(r_i - r_j)^2 - \gamma\,(I_i - I_j)^2\right),$$

where $I$ is image intensity and $\beta,\gamma \ge 0$ weight asymmetry change against brightness change. Setting $\beta=0$ recovers the intensity-only expansion of Can et al. (2018). The random-walk probabilities are thresholded, and only high-confidence voxels become pseudo-labels. The rest stay unlabeled, so the downstream nnU-Net with partial loss still ignores voxels where the evidence is weak.

Two safeguards cover the known failure cases. For bilateral disease, the residual map is flat and uninformative, so the expansion should fall back toward intensity behavior. For midline-crossing masses, the file flags these as fatal for SATS and BrainNormalizer (Kwak et al. (2025)). We therefore compute a per-case reliability score from the residual's spatial spread and down-weight $\beta$ when the score says the mirror reference is corrupted. Both safeguards are evaluated explicitly rather than assumed.

The third component is standard training: an unmodified 3D nnU-Net with partial loss on the expanded pseudo-labels. The segmenter is left untouched so that any gain can be attributed to the label signal, not to capacity.

Baselines

The naive reference is nnU-Net with partial loss on raw scribbles, run exactly as in Gotkowski et al. (2024) with their released scribbles and default planning. The file reports its ScribbleBench mean Dice of 0.813. It does not give per-task values for BraTS2020 or KiTS2023, so no reported result was found on Lacuna for nnU-Net with partial loss on those individual tasks. We will reproduce them and report our reproduction next to the 0.813 mean as a sanity check. Beating this baseline means a statistically significant gain in Dice and Normalized Surface Dice on each target task across three seeds.

The strongest competitor on the boundary question is a bilateral-input nnU-Net with partial loss. It receives the aligned flipped volume as a second input channel and is otherwise identical. This is the cheapest way to bring the contralateral side in, and it is the strongest threat to the proposal. On dense-label tasks, SATS and DRT-M3D show that bilateral input alone helps. For a dense-supervision reference point we also report SATS-style training with full masks on SegRap2023, where the file gives SATS at 66.80% external GTV Dice (Li et al. (2025)).

A third baseline is intensity-only expansion ($\beta=0$) followed by nnU-Net with partial loss, representing the Can et al. and Ji et al. lineage.

The ablation that isolates the key ingredient replaces the learned residual $r$ with raw mirrored subtraction $|I - I_{\text{mirror}}|$ in the same affinity. A further ablation feeds $r$ as an input channel instead of using it in expansion. All methods share splits, scribbles, nnU-Net planning, and epochs. The expansion hyperparameters $\beta$, $\gamma$, and the threshold are tuned on a held-out validation fold with the same number of trials given to each method's own tunable parameters.

Why not just…?

Why not just give nnU-Net the flipped image as an extra channel? This is a real threat. Under dense labels it is roughly what SATS and DRT-M3D exploit, and it costs nothing. Our argument is that with partial loss, the network receives no gradient at unlabeled boundary voxels. Extra input evidence there may never be used, whereas expansion converts that evidence into supervision. This is a hypothesis, not a finding. The bilateral-channel baseline tests it directly. If it matches our method on boundary metrics, we will report that the contribution reduces to the input channel and drop the expansion machinery.

Why not just refine pseudo-labels with DenseCRF or graph cut? These use intensity discontinuities. The file records that they bleed at low-contrast borders (Ji et al. (2019)), trade recall for precision on CT lesions (Agarwal et al. (2020)), and are sensitive to kernel bandwidth (Can et al. (2018)). Our affinity is a strict generalization of this approach, and the $\beta=0$ baseline measures exactly what the asymmetry term adds.

Why not just subtract the mirrored image? Natural asymmetry and misalignment create false differences (Liang and Han (2021), Zhao et al. (2020)). SATS found that unfiltered mirror distances even hurt performance. The subtraction ablation tests whether our learned predictor actually removes this noise. If raw subtraction performs equally well, the predictor is unnecessary.

Proposed Experiments

The primary tasks are BraTS2020 and KiTS2023 from ScribbleBench, using its scribbles. Both involve paired anatomy (cerebral hemispheres, kidneys) with mostly unilateral tumors. The third task is SegRap2023 nasopharyngeal GTV on non-contrast planning CT, the hardest low-contrast case in the file. For SegRap2023 we generate scribbles from the dense masks with the ScribbleBench protocol. Since kidney mirroring is looser than brain mirroring, KiTS serves as a test of how much misalignment the predictor tolerates. Metrics are Dice, Normalized Surface Dice at 1 mm, and 95th-percentile Hausdorff distance. The headline number is the fraction of the scribble-to-dense gap closed, measured against a dense nnU-Net trained on the same splits.

Two decisive checks go beyond average scores. First, we stratify boundary voxels by local contrast, measured as the intensity gradient across the true edge. The proposal predicts that gains concentrate in the lowest-contrast bins and vanish in high-contrast bins. A uniform gain would suggest a generic regularization effect instead. Second, we evaluate two hard subsets separately: cases with midline shift or bilateral involvement, identified from the dense masks, and the remaining cases. The method should help on the second subset. With the reliability safeguard on, it should do no harm on the first, and turning the safeguard off should make that harm visible.

Finally, we check the pseudo-labels themselves against the held-out dense masks, separating precision and recall. This shows whether the improvement comes from stopping leakage, as claimed, or from something else.