Contact Tracing for Silent Model Failure Across Hospitals

When one frozen medical imaging model is deployed at many hospitals, a scanner software update or a new reconstruction protocol can quietly degrade its accuracy. Nobody notices until enough confirmed diagnoses come back to show the error rate has risen, and that can take weeks. This problem has the same structure as pre-symptomatic transmission in epidemics, where a person becomes contagious before they show symptoms. In the imaging case, the model starts failing (the biological clock) well before any labeled audit reveals the failure (the symptom clock), and every image read in that gap is a potential harm. Epidemiologists learned that isolating people only after symptoms appear fails when these two clocks are mismatched. They learned that tracing backward from a confirmed case to its likely source, and then forward to that source's other contacts, recovers most of the lost control. We propose to transfer that lesson to monitoring deployed imaging models.

The concrete idea is to build a graph linking hospital sites to the acquisition sources they share: scanner model, software version, reconstruction kernel, and protocol. When a label audit confirms that the model is failing at one site, the system traces back to the sources that site uses and moves up the audit queue of every other site that shares them. Label-free warning signals computed from the frozen model's own outputs rank the candidates. The payoff is that one confirmed failure, which is scarce and delayed, can be spread across the graph to confirm or dismiss the much cheaper label-free alarms elsewhere. Label-free alarms are frequent and mostly benign, so this confirmation is what they have been missing.

Core Claim

Under a fixed label-audit budget, backward-then-forward tracing over a site–source graph will detect harmful domain shifts earlier and with fewer wasted audits than monitoring each site independently. The measure is the number of images read by a degraded model before detection. The gain should be largest in the regime that matters most, where labels are delayed and sparse. This is the analogue of the regime studied in Graph Learning for Bidirectional Disease Contact Tracing on Real Human Mobility Data. In that paper, with only 30% of symptomatic cases tested, forward tracing moved the reproduction number $R_t$ only from 1.33 to 1.27, while tracing two hops backward and then forward brought it to 0.54. We do not expect epidemic-sized effects. The claim is structural: when the observable signal lags the harmful state, pooling confirmations along shared-source edges beats treating each node alone.

Why this intersection, and what it is not

The obvious bridge between these two directions is to detect pre-symptomatic lung opacities on CT robustly across scanners. Generalized chest CT and lab curves throughout the course of COVID-19 found that opacities appear on CT about 3.4 ± 2.2 days before symptoms. Artificial intelligence for the detection of COVID-19 pneumonia on chest CT using multinational datasets built a multinational CT classifier (AUC 0.949) but states that it cannot handle early cases. We reject that direction as the core project for two reasons. The only longitudinal pre-symptomatic imaging cohort in the file has 29 patients, which is too few to train or fairly evaluate anything under cross-site shift. A reviewer would also rightly say that molecular testing, not CT, is how one screens exposed contacts. The pre-symptomatic literature therefore serves here as the methodological lens: the mismatch between the latent and incubation periods, and bidirectional tracing. Domain shift in imaging is the application.

Existing domain-shift work motivates and constrains this design in three ways. Regulating AI Adaptation: An Analysis of AI Medical Device Updates supplies the motivation. It reports cross-site drops of up to 0.18 AUC for a chest X-ray model. It finds that only 6 of 416 FDA-cleared devices were retrained within two years, and that local fine-tuning costs the original site 0.176 AUC on average. Deployed models are therefore effectively locked, and detection is the lever a hospital actually controls. Improved post-hoc probability calibration for out-of-domain MRI segmentation supplies one of our label-free signals. It measures pixel susceptibility to test-time augmentation on a frozen segmenter; we reuse that signal as an alarm rather than as a calibration input. Adapt the Data, Not the Model: Input-Space Adaptation for Frozen Time-Series Predictors and ErrorNet: Learning error representations from limited data to improve vascular segmentation are repair methods that could run after detection. We treat them as downstream and out of scope. INPUTADAPTER in particular needs target labels, and our tracing is designed to find those labels efficiently.

Research Program

The system has three parts.

The first is a bipartite graph. One side holds deployment sites and the other holds acquisition sources, with an edge when a site's images come from a source. This mirrors the person–venue graph of the mobility study.

The second is a per-site, label-free alarm score computed weekly from the frozen model alone. It combines prediction confidence, test-time augmentation susceptibility in the style of Ouyang et al., and a feature-distribution distance to the development data. These alarms play the role of noisy self-reported symptoms in Proactive Contact Tracing. That paper turned such noisy signals, together with contact history, into graded infectiousness risk instead of binary quarantine. We likewise output graded audit priority instead of binary alarms.

The third is a tracing policy. When an audit confirms a failure at a site, the policy assigns suspicion to that site's sources, weighted by how recently each source changed and how strongly it co-varies with the alarm. It then raises the audit priority of other sites in proportion to their exposure to the suspected sources and their own alarm scores. We will build two versions. One is a transparent rule-based tracer. The other is a small graph neural network edge classifier trained on simulated shift events, following how the mobility study trained on simulated infection labels.

The quantity we optimize and report is exposure. It is defined as $X = \sum_{s} n_s \, \Delta_s \, (t^{\mathrm{det}}_s - t^{\mathrm{on}}_s)$, where for site $s$, $n_s$ is the weekly image volume, $\Delta_s$ is the true drop in the model's accuracy metric, $t^{\mathrm{on}}_s$ is when the harmful shift began, and $t^{\mathrm{det}}_s$ is when the policy flagged it. Exposure counts degraded reads weighted by severity, and is our analogue of infections that occur during the silent window. Every policy gets the same weekly audit budget $B$ of labeled cases and the same label delay $D$.

The honest weakness is that no public dataset records real multi-hospital deployments with firmware histories. As in the contact-tracing work, the graph and shift timing will be simulated, while the images, the frozen models, and the per-image shift effects will be real.

Baselines

The naive reference is uniform scheduled auditing. Each week every site receives an equal share of the budget $B$, and a site is flagged once its audited error exceeds a threshold. This is roughly what post-market surveillance does today. It fixes the scale of exposure that any method must beat.

The strongest realistic competitor is independent per-site label-free monitoring. It uses the same combined alarm score as our method, allocates audits greedily to the highest-alarm sites, and ignores the graph. It uses exactly the same signals, budget, and delay, so any gain from our method can come only from pooling along edges. Its thresholds and allocation temperature get the same tuning budget on held-out simulation seeds as our tracer's parameters. No reported result was found on Lacuna for exposure or time-to-detection of harmful drift on any benchmark in the file, so we will establish this number ourselves. Beating it means lower exposure at equal budget, with a paired confidence interval over simulated deployments that excludes zero, and a false-alarm audit rate no higher.

The metadata-rule baseline flags every site that shares a source whenever that source changes, for example on a firmware version bump. It represents what an informatics team could do with image headers alone.

Two ablations isolate the key ingredient. The first is forward-only tracing, which raises priority only at a confirmed site's direct source-mates without inferring which source is at fault. The second is tracing without label-free alarms, which uses graph structure alone. Comparing bidirectional against forward-only tests whether backward inference to the source matters, as it did in the mobility study. Comparing with and without alarms tests whether the graph adds anything beyond borrowing confirmation.

Why not just…?

Why not just run a good drift detector at each site? Label-free detectors fire on many shifts that do not hurt accuracy. The Ouyang et al. results show the gap: their calibration improvements under realistic artifacts and a real protocol shift were modest (expected calibration error from 14.48% to 12.78%, and from 16.78% to 15.37%). Confidence-type signals therefore track true error only loosely out of domain. Independent per-site monitoring is our strongest baseline precisely because it uses identical signals. If it matches tracing at equal budget, the graph adds nothing, and we will report that.

Why not just watch image headers for scanner and software changes? This is a real threat. If every harmful shift appears in metadata and benign changes are rare, the header rule will be hard to beat. Our simulations therefore vary two things independently. One is the fraction of harmful shifts invisible in headers, such as protocol drift, dose changes, or new patient populations. The other is the fraction of header changes that are benign. We expect tracing to win only when benign header changes are common or when causes are hidden. If the header rule dominates across realistic settings, the correct conclusion is that the contribution reduces to using confirmed failures to rank header changes, and we will state it that way.

Why not just audit more labels, or fine-tune continuously? More audits shrink exposure for every policy. The interesting question is exposure at a fixed, realistic budget and delay, so we report full budget–exposure curves rather than a single point. Continuous fine-tuning is ruled out as a default by the regulatory lock and the 0.176 AUC source-site loss documented by Wu et al. Even where adaptation is allowed, a system must first know which sites need it.

Proposed Experiments

We will use three testbeds that differ in how natural the sources are.

The first is the NIH, Stanford, and Beth Israel chest X-ray pneumothorax setting from Wu et al. We train a DenseNet-121 on one hospital and freeze it. Virtual deployment sites draw mixtures of the three hospitals' images, with shifts delivered by swapping a site's mixture, so each shift has a real effect on the model, up to the reported 0.18 AUC drop.

The second is cardiac MRI from ACDC and MS-CMRSeg, with a frozen segmenter. Sources are Torchio artifact profiles (bias field, motion, ghosting, spikes) plus the real change from bSSFP to LGE sequences. This lets us control severity, including shifts that trigger alarms without hurting accuracy.

The third is retinal vessel segmentation. We train on CHASE and treat DRIVE, STARE, ARIA, and HRF as distinct camera sources, following the cross-dataset setup of ErrorNet. This gives natural, unsimulated source identities.

For each testbed we simulate hundreds of deployments with 30 to 100 sites and 5 to 20 sources. Shift events arrive at random times and spread through sources. We vary the label delay $D$ from one to eight weeks and the budget $B$, and the tracer's tuning seeds are kept separate from its evaluation seeds. The metrics are exposure $X$, median time-to-detection for harmful shifts, and the fraction of audits spent on sites with no harmful shift.

The decisive checks are these. The main result must show that bidirectional tracing beats independent per-site monitoring at equal budget and delay. The gap should widen as $D$ grows and as $B$ shrinks; if it does not, the analogy to the pre-symptomatic window is empty. The metadata-rule comparison must show where tracing adds value beyond headers, if anywhere. The forward-only ablation must show that inferring the source matters. We will also check robustness to a misspecified graph, with 20% of edges dropped or added, since real hospitals will not know their source links perfectly. Finally, we will train the graph-network tracer on the MRI simulations and test it on the chest X-ray graphs to see whether the learned policy transfers rather than overfitting one simulator. This addresses the same concern the mobility study faced when it relied on synthetic infection labels.