Clinicians and speech researchers increasingly measure how "random" a voice is by looking at the phase of its harmonics. In a healthy voice the vocal folds close the same way each cycle, so the relative timing of successive harmonics repeats. In a hoarse or disordered voice it jitters. The best-known measure of this jitter, Phase Distortion Deviation (PDD), has a known flaw. Anything that scrambles harmonic phase raises it, including the patient's vocal folds, turbulent breath noise, a cheap microphone's phase response, and background hiss. A high PDD reading therefore cannot say whether the patient or the equipment produced it. Precision physics treats this kind of problem as a residual systematic uncertainty: a bias from the instrument that collecting more data does not remove, and that has to be measured with an independent channel.
We propose such an independent channel for the voice. The electroglottograph (EGG) is a pair of electrodes on the neck that records vocal-fold contact electrically. It sees none of the vocal tract, the room, or the microphone. The Saarbrücken Voice Database records EGG alongside audio for roughly 1,850 speakers. The idea fits in two sentences. Cycle-to-cycle phase fluctuations caused by the vocal folds should appear in both the microphone and the EGG, while channel distortion, additive noise and breath turbulence appear only in the microphone. The part of acoustic phase randomness that co-varies with the EGG, measured cycle by cycle, is therefore a source-level randomness estimate whose channel bias is controlled by construction. It also supplies a principled error budget for audio-only estimators that must run on phones.
Core Claim
The obvious way to join these two fields is Daya Bay-style ratio cancellation, which divides out common instrument effects between two detectors (New Measurement of Antineutrino Oscillation with the Full Detector Configuration at Daya Bay). Applied here, it would mean taking the acoustic-to-EGG cross-spectral phase. We think this naive version is wrong for this problem. Dividing the acoustic spectrum by a source-referenced spectrum cancels the glottal source too, leaving mostly the vocal tract and the channel, which is the opposite of what we want to measure.
The analogue that does fit comes from two-detector cross-correlation. The signal is shared between the detectors, the noise is independent, so the covariance between them estimates signal variance without noise bias. Concretely, let $a_k(n)$ be the acoustic phase distortion at harmonic $k$ in glottal cycle $n$, after removing its local mean (the PDM trend), and let $g_k(n)$ be the same quantity computed from the EGG harmonics. We model
$$a_k(n) = s_k(n) + e_k(n), \qquad g_k(n) = c_k\, s_k(n) + u_k(n).$$
Here $s_k$ is the vocal-fold-driven fluctuation, $c_k$ is an unknown gain relating contact to acoustic flow, $e_k$ collects channel, additive and aspiration effects seen only acoustically, and $u_k$ is EGG measurement noise. If $e$ and $u$ are independent of each other and of $s$, then $\mathrm{Cov}(a_k,g_k)=c_k\mathrm{Var}(s_k)$, and neither $e$ nor $u$ contributes. We define a coherent phase randomness per harmonic as the magnitude-squared coherence
$$\gamma_k^2=\frac{\mathrm{Cov}(a_k,g_k)^2}{\mathrm{Var}(a_k)\,\mathrm{Var}(g_k)}.$$
We also define the acoustic incoherent residual, $\mathrm{Var}(a_k)(1-\gamma_k^2)$, which absorbs microphone systematics and breath noise. Wrapped (circular) differences are used throughout, and the linear model is applied only after mean removal, where the fluctuations are small angles.
A practical convenience makes this workable. Phase distortion is a difference between adjacent harmonics, so it is already invariant to any time delay between the two channels. We therefore need to match cycles, not to align the channels to sub-millisecond phase accuracy. Frame-level phase-based synchronisation of the kind in Accurate Synchronization of Speech and EGG Signal Using Phase Information is sufficient. That paper cross-correlates Hilbert phases of EGG and filtered speech to estimate the glottis-to-microphone delay on healthy CMU-Arctic speakers. The residual within-frame drift it reports is harmless to our measure, whereas it would bias the naive ratio approach.
The new, testable claims follow from the model. The coherent part should be insensitive to injected microphone distortion and noise, while raw PDD is not. The split between coherent and incoherent parts should begin to pull apart hoarse-type irregularity (pulse-shape chaos, which the EGG sees) from breathy-type turbulence (which it does not). That is exactly the confusion Phase distortion statistics as a representation of the glottal source: application to the classification of voice qualities reports for PDD.
Research Program
We build on the phase-distortion pipeline of Degottex and Obin, which differences relative phase shifts across harmonics to cancel timing. We also use the adaptive-harmonic-model extraction with vocal-tract minimum-phase removal from The importance of phase on voice quality assessment, which introduced the Regularity Ratio (RR) on spasmodic dysphonia. The pipeline is run in parallel on SVD audio and EGG. Because the EGG has no vocal tract, it needs no minimum-phase deconvolution, which removes one fragile step from the reference channel.
The first work package tests the core assumption: that per-cycle fluctuations in the two channels actually co-vary. We check this first on CMU-Arctic, where healthy speech should give low but nonzero coherence. We then check it on SVD, where we expect coherence to rise with pathology. We explicitly test whether the gain $c_k$ is stable within a speaker. The EGG measures contact rather than airflow, and the whole method fails if that relation is too nonlinear.
The second work package builds a systematics injection suite modelled on the physics practice of propagating known nuisance shifts. Clean SVD audio is passed through measured or parametric consumer-microphone responses, including frequency-dependent phase, preamp nonlinearity and additive noise at controlled signal-to-noise ratios. The EGG is left untouched, and we measure how each statistic moves. This gives, for raw PDD, RR, and coherent randomness, a systematic shift per nuisance expressed in units of the healthy-versus-pathological separation. The result is a real error budget rather than an accuracy number.
The third work package addresses deployment, since phones have no EGG. We train an audio-only estimator to predict the coherent quantity. The cleanest option is a regression head on the phase features used by Automatic Estimation of Pathological Voice Quality Based on Recurrent Neural Network Using Amplitude and Phase Spectrogram, which feeds instantaneous-phase-corrected, mel-scaled phase-difference spectrograms to recurrent networks for GRBAS rating. The EGG-derived target is used only during training, and the model is trained on injected-channel audio. Solving Simulation Systematics in and with AI/ML warns that learned corrections carry their own "second-order" systematic, which it leaves unbounded. Here that residual is directly measurable: the estimator's error against the EGG-referenced target on held-out speakers, stratified by pathology, is reported as its systematic uncertainty. This lets us ask the question raised in the research file's Gap 4: does estimator error itself masquerade as phase randomness?
The main limitation is known in advance. When the glottis does not close, as in paralysis or severe breathiness, the EGG signal becomes weak, so $u$ grows and coherence falls for reasons unrelated to the source. We will report EGG quality per recording and treat low-quality EGG as a flagged regime rather than hide it.
Baselines
The naive reference is raw PDD and its Regularity Ratio computed from audio alone, exactly as in Koutsogiannaki et al. That paper reports a Spearman correlation of −0.82 with clinical severity for RR, against −0.68 for the amplitude-based WMTV, on its spasmodic dysphonia corpus. We rerun this identical extraction on SVD, clean and channel-injected. Beating it means a smaller systematic shift under injection at equal or better healthy-versus-pathological separation.
The strongest existing method against channel systematics is domain-adversarial training, from Robustness against the channel effect in pathological voice detection. It pairs a bidirectional LSTM on MFCCs with a device classifier behind a gradient-reversal layer, so the encoder cannot tell devices apart. On FEMH it lifts smartphone PR-AUC from 0.8448 to 0.9455, against a supervised upper bound of 0.9522. We reimplement it on SVD with the same injected-device splits, the same unlabeled target audio, and a matched hyperparameter search budget. Our audio-only estimator uses the same backbone size, so the comparison is fair. Beating it on detection is not required. The claim is that DAT delivers invariance without saying what was removed, while ours measures it. We count a win if our system matches DAT's detection within noise while showing that DAT's invariant features lose sensitivity to mildly irregular voices, the concern raised by Anomaly preserving contrastive neural embeddings for end-to-end model-independent searches at the LHC. That paper found that representations tuned to suppress background variation wash out rare anomalies.
The strongest detector on SVD in the file is the constrained autoregressive hidden Markov glottal model of Comparison of GIF- and SSL-based Features in Pathological-voice Detection. It reaches a test F1 of 75.27%, against 74.21% for a modified CPC self-supervised model, on its 8:1:1 split. We use that split where reproducible. Separately, Automated Detection of Voice Disorder in the Saarbrücken Voice Database: Effects of Pathology Subset and Audio Materials reports about 80% unweighted average recall for an SVM on all vowels plus phrase, with speaker-independent 5-fold cross-validation. We report against both protocols, and do not claim a win unless coherent features added to the SVM exceed that recall.
The key ablation replaces each recording's EGG with the EGG from a different sustained vowel of the same speaker. This preserves speaker-level statistics but destroys cycle-level correspondence. If coherent randomness still "works," the benefit came from EGG summary statistics, not from cross-channel coherence.
Why not just…?
Why not just use MFCCs with domain-adversarial training, as Hsu et al. do? For detection it may be nearly as good, and we say so. Its 0.9455 PR-AUC already sits close to the supervised bound. But it answers a different question. It makes a classifier device-blind without saying how much of any phase-randomness reading is instrument-caused, and it discards phase, which carried non-redundant information in Degottex and Obin (81.0% balanced accuracy for MFCC plus phase statistics versus 77.5% for MFCC alone). The injection experiments and the mild-pathology sensitivity test settle whether global invariance costs anything.
Why not just correct PDD for noise analytically, using the measured harmonic-to-noise ratio? This is the most serious threat. For stationary additive noise, the expected PDD inflation at a given per-harmonic signal-to-noise ratio can be computed and subtracted, with no EGG needed. We include this correction as a baseline. We expect it to handle hiss but to fail on two kinds of error. The first is microphone phase nonlinearity, which is not captured by signal-to-noise ratio. The second is aspiration noise, which varies with the source and so cannot be subtracted as a constant. If the analytic correction matches coherent randomness under every injected nuisance, we would narrow the contribution to the breathy-versus-hoarse separation and the error budget for audio-only estimators.
Why not just use EGG features directly, such as EGG jitter or contact quotient? EGG period jitter measures timing, not pulse-shape dispersion across harmonics. EGG alone also cannot tell how much of the acoustic reading is contaminated, and that contaminated reading is what a phone produces. We run EGG-only feature baselines. If they equal coherent randomness at detection, the value that remains is the calibration target for audio-only models, which EGG features cannot provide.
Why not rely on self-supervised speech models to absorb channel variation? Sasou and Chen found the best one generalised slightly worse than a physical glottal model on unseen SVD speakers. We include a CPC-style baseline under the same injections to check whether its features drift with the device.
Proposed Experiments and Decisive Checks
The first decisive check is invariance. Across injected devices and noise levels on SVD, the shift in coherent randomness should be substantially smaller than the shift in raw PDD, expressed relative to the healthy-versus-pathological gap. If it is not, the independence assumption fails and the project stops there.
The second is the healthy null. On CMU-Arctic and healthy SVD speakers, coherent randomness should be low and stable across injections. The shuffled-EGG ablation should drive coherence toward zero everywhere.
The third is physiological separation. Among SVD diagnoses dominated by incomplete closure versus mass lesions, the incoherent share should rise for the former and the coherent share for the latter, restricted to recordings with adequate EGG quality.
The fourth is transfer. The audio-only estimator's held-out error against the EGG target is reported as a second-order systematic, per pathology group. Its detection performance is compared to DAT and to the SVD baselines at matched budgets. If FEMH access allows, the estimator is also evaluated on its real smartphone split. No reported result was found on Lacuna for phase features on FEMH.
References
- New Measurement of Antineutrino Oscillation with the Full Detector Configuration at Daya Bay
- Accurate Synchronization of Speech and EGG Signal Using Phase Information
- Phase distortion statistics as a representation of the glottal source: application to the classification of voice qualities
- The importance of phase on voice quality assessment
- Automatic Estimation of Pathological Voice Quality Based on Recurrent Neural Network Using Amplitude and Phase Spectrogram
- Solving Simulation Systematics in and with AI/ML
- Robustness against the channel effect in pathological voice detection
- Anomaly preserving contrastive neural embeddings for end-to-end model-independent searches at the LHC
- Comparison of GIF- and SSL-based Features in Pathological-voice Detection
- Automated Detection of Voice Disorder in the Saarbrücken Voice Database: Effects of Pathology Subset and Audio Materials