When a patient has a metal implant, a CT scanner loses much of the information along the X-ray paths that pass through the metal. The reconstructed image then shows bright and dark streaks, and the anatomy near the implant is often unrecoverable. Multimodal large language models, meaning language models that also take images as input, are starting to be used to draft radiology descriptions. They are already weak at saying where a lesion is on clean CT slices. Our concern is narrower and, we think, more dangerous. We expect these models to stay just as confident when the evidence has been physically destroyed. We also expect artifact-removal software to make things worse: it paints plausible anatomy into the damaged region, the image looks clean, and the model's confidence comes back even though the information never did. This is a metacognitive calibration failure, a mismatch between how sure a reader is and how often it is right. What makes it worth studying is that the physics tells us exactly how much information was lost and where.
The proposal is this. Compute an evidence map from the scan geometry, giving the fraction of intact X-ray paths behind each pixel. Pass this map along with the image through any artifact-reduction step. Train the model's confidence so that it must fall at least in proportion to lost evidence, and enforce this as a hard constraint during training rather than a tunable penalty. We will first measure whether confidence and evidence become decoupled under graded, simulated metal artifacts. We will then test whether this physics-anchored constraint removes confidently stated hallucinations in low-evidence regions better than generic recalibration does.
Core Claim
Our claim is that the right reference signal for a model's confidence under metal artifacts is the information content of the raw projection data, not the appearance of the processed image. Image-based uncertainty cannot see what generative artifact reduction has erased. A model that receives the evidence map and is trained under a monotone-decrease constraint should do two things. It should withhold high-confidence findings in photon-starved regions, and it should keep its accuracy and confidence on intact regions. The claim fails in either of two cases: generic calibration fixes the problem equally well, or the post-reduction "confidence rebound" does not exist.
Why this gap is real
The material comes from four separate literatures. On the imaging side, DuDoNet explains how metal causes beam hardening and photon starvation. It also supplies a standard way to simulate metal on DeepLesion and a strong reduction method, reported at 33.51 dB PSNR against 29.52 dB for CNNMAR and 25.47 dB for linear interpolation. The review Mitigating Metal Artifacts in Medical Imaging raises the concern that motivates us: artifact-reduction algorithms can create false hot spots and synthetic anatomy that mimics pathology. Generative variants such as perpendicular score-based diffusion for CBCT, which fills in artifact regions with a learned prior, make this risk sharper.
On the language-model side, GPTRadScore scores multimodal descriptions of 500 DeepLesion slices. It reports lesion-location accuracy of 17.1% for GPT-4V and 14% for Gemini Pro Vision, and 12.8% for RadFM even after fine-tuning. It also finds that bounding-box prompts help. Localizing Before Answering traces medical visual hallucination to failed spatial grounding and makes the model emit a segmentation token before it answers. That work is limited to chest X-rays and says nothing about confidence. Neither paper looks at metal artifacts, and neither asks whether stated confidence tracks the evidence available.
On the calibration side, Levy et al. show what is at stake downstream. With pre-populated machine suggestions, clinicians' recall of findings the machine missed dropped 12%, while unassisted controls improved 4%. The clinicians also failed to correct 33% of wrong spans, yet reported feeling more thorough. Nguyen et al. show that deferring to whichever partner is more confident helps only when both partners are calibrated. Göppert et al. prove that metacognitive quality raises group accuracy even with first-order accuracy held fixed. Together these three results motivate treating confidence quality as the target, separate from accuracy.
The Lyapunov literature supplies a method, not a stability guarantee. HALO enforces a decrease condition on a potential function during policy optimization. At each update it projects gradients into a half-space by solving a small quadratic program, and it reports that this beat soft objectives: a rationality gap of 0.09 versus 4.89 for HAPPO. The predictive stability filters paper minimally modifies an arbitrary controller's proposed action so that it satisfies a hard dissipation inequality. We reuse both ideas: a hard decrease inequality, enforced by projection, placed between a model's raw output and what the user sees. The one prior paper that pairs Lyapunov constraints with "hallucination," F2-CommNet, uses the word for spurious clusters in graph data. It shares the vocabulary, not the problem. We also reject the more obvious move of imposing Lyapunov stability on LLM hidden-state trajectories, because there is no principled energy function in that space. Here there is one: evidence retention, which physics gives us.
Research Program
We work in simulation first, following DuDoNet's protocol. Metal masks of varying size and density are inserted into clean DeepLesion slices. The slices are forward-projected with a polychromatic model and reconstructed. This yields, for every lesion, a ladder of severities $s = 0, 1, \dots, S$ that shares the same ground-truth anatomy and annotations.
For each ladder rung we compute an evidence-retention map from the metal trace, which is the set of projection rays that cross metal:
$$e(x) = 1 - \frac{1}{|R(x)|}\sum_{r \in R(x)} \mathbb{1}[r \text{ crosses metal}],$$
where $R(x)$ is the set of rays through pixel $x$. This map is also computable at deployment on real scans. The metal is segmented by thresholding and forward-projected, the same step linear-interpolation artifact reduction already performs. We write $\bar e$ for the average of $e(x)$ over the region a question refers to. The map is stored alongside the image and survives any artifact-reduction step, so a cleaned image still carries a record of what was lost.
The first stage is measurement. We pose GPTRadScore-style questions (body part, location, finding type) plus region-specific presence questions to RadFM, LLaVA-Med, and API models. Each is tested under five inputs: the clean image, the corrupted image, and the image after linear interpolation, after DuDoNet-style dual-domain reduction, and after a diffusion-based reduction. We elicit confidence both verbally and from answer-token probabilities. We then measure how fast accuracy and confidence fall as $\bar e$ falls. We also measure metacognitive efficiency, the ability of confidence to separate one's own correct from incorrect answers, as the type-2 area under the ROC curve used in the calibration literature. Finally, we record the rate of confidently asserted findings in regions where the clean image has no lesion. The specific prediction is a rebound: after generative reduction, confidence recovers toward its clean level while accuracy in low-$\bar e$ regions does not, and inpainted structures become the sites of fabricated findings.
The second stage is the intervention. We give $\bar e$ to the model as an extra input and fine-tune a confidence head. Training minimizes a proper scoring loss subject to a hard constraint across ladder rungs of the same case. Whenever evidence drops from rung $s$ to $s'$, confidence $c_\theta$ must drop at least proportionally, down to a floor at chance level $c_0$:
$$c_\theta(s') \le \max\big(c_0,\; c_\theta(s) - \kappa\,[\bar e(s) - \bar e(s')]\big).$$
Here $\kappa$ sets the minimum confidence cost per unit of lost evidence. This inequality plays the role of a discrete Lyapunov decrease condition, with confidence as the "energy" and evidence loss as the dissipation. As in HALO, we enforce it by projecting each gradient step onto the constraint half-space, not by adding a weighted penalty. At inference only one scan is available, so there is no ladder. The trained head then acts as a learned, evidence-conditioned upper bound. Optionally, a filter-style projection clips any confidence that exceeds this bound.
The third stage is small and conditional on the first two succeeding: a reader study. Radiologists review model drafts for artifact-laden cases with and without evidence-bounded confidence. Following Levy et al., we measure their recall of findings in low-evidence regions, their correction rate for fabricated findings, and their self-rated thoroughness.
Baselines
The naive reference is the unmodified model's raw confidence, evaluated on the same ladders. It shows the size of the decoupling and sets the floor every method must clear.
Temperature scaling fits a single global rescaling of confidence on clean validation slices. It is the default calibration fix. It gets the same validation split as every other method and a full sweep over the temperature.
The strongest simple competitor is severity-conditioned isotonic recalibration. It fits a monotone map from (raw confidence, $\bar e$) to accuracy on the same training ladders and receives the identical evidence map. This baseline isolates whether a post-hoc lookup is enough, or whether training the model under the constraint changes what it attends to. It gets the same data and the same hyperparameter budget as our method.
The strongest existing method for grounding is localize-before-answer prompting and fine-tuning in the style of Localizing Before Answering. We adapt it to CT using DeepLesion boxes, which also matches GPTRadScore's finding that boxes help. For reference, the strongest reported numbers on this data are GPT-4V's 17.1% location accuracy and fine-tuned RadFM's 12.8%, both from GPTRadScore. We found no reported result on Lacuna for calibration or type-2 AUROC of multimodal LLMs on metal-artifact CT, so we will establish those numbers ourselves.
Two ablations isolate the key ingredients. The first replaces the hard projection with a hinge penalty of tuned weight, testing whether hard enforcement matters. The second replaces the raw-data evidence map with an artifact-severity estimate computed from the processed image alone, testing whether carrying the metal trace past reduction is the essential part.
Beating the baselines means lower fabricated-finding rates at matched coverage in regions with $\bar e < 0.5$, together with higher type-2 AUROC. It also requires no loss of accuracy, and no worse calibration, on clean scans and intact regions.
Why not just…?
Why not just recalibrate with temperature scaling or conformal prediction? A single global correction cannot flatten a relationship that changes with severity, and it gets worse after reduction, where the image itself hides the damage. Conformal sets calibrated on clean or mixed data carry the same blindness unless they condition on evidence. The measurement stage will show whether per-severity miscalibration actually varies. If it does not, this alternative wins and we will say so.
Why not just run the best artifact reduction first? Reduction improves PSNR, as DuDoNet shows. But PSNR rewards plausibility, and the concern raised in Mitigating Metal Artifacts in Medical Imaging is that plausible synthetic anatomy is precisely the failure. Our post-DuDoNet and post-diffusion conditions test this directly. If fabricated-finding rates on reduced images fall to clean-image levels, the motivation collapses.
Why not just multiply confidence by the evidence map, with no training? This is the most serious threat. The isotonic baseline is a fitted version of this idea. Our method has to beat it on metacognitive efficiency, not only on calibration error, because only a trained model can learn to change which answers it is confident about. If the fixed gate matches our method, we will report that the physics map is the contribution and the constraint is unnecessary.
Why not just let the radiologist catch it? Levy et al. found that experts miss what the machine missed and still feel more thorough. Nguyen et al. found that confidence-based deference breaks down when a partner is miscalibrated. The reader study measures whether this holds for CT drafts.
Decisive Checks
The project starts with one check that can falsify it cheaply. On the DeepLesion ladders, does confidence fall more slowly than accuracy as $\bar e$ drops? And does it rebound after generative reduction while accuracy in low-evidence regions stays low? If both appear, the second check is whether the constrained model beats severity-conditioned isotonic recalibration on type-2 AUROC in low-evidence regions, measured by paired bootstrap across cases. The third is whether the raw-trace ablation loses most of that gain once images have passed through reduction. That result would confirm that the information about what was destroyed has to travel with the image.
References
- DuDoNet: Dual Domain Network for CT Metal Artifact Reduction
- 3D CBCT Artefact Removal Using Perpendicular Score-Based Diffusion Models
- How well do multimodal LLMs interpret CT scans? An auto-evaluation framework for analyses
- Localizing Before Answering: A Hallucination Evaluation Benchmark for Grounded Medical Multimodal LLMs
- Assessing the Impact of Automated Suggestions on Decision Making: Domain Experts Mediate Model Errors but Take Less Initiative
- Group Decision-Making in Robot Teleoperation: Two Heads are Better Than One
- Information-Theoretic Measures of Metacognition: Bounds and Relation to Group Performance
- Learning Human-Robot Collaboration via Heterogeneous-Agent Lyapunov Policy Optimization
- Predictive stability filters for nonlinear dynamical systems affected by disturbances
- F2-CommNet: Fourier-Fractional neural networks with Lyapunov stability guarantees for hallucination-resistant community detection