Hospitals are adopting ambient scribes. These are systems that record the doctor–patient conversation, transcribe it with automatic speech recognition (ASR), and fill in the patient record automatically. Separately, oncology researchers now train models that predict whether a patient will respond to immune checkpoint drugs from a handful of patient features: drug class, tumor mutational burden, age, laboratory values. Checkpoint drugs are antibodies that release the "brakes" on T cells. These two developments are about to meet. Once features that feed a response predictor are populated from spoken encounters, transcription mistakes become prediction mistakes. The mistakes that matter are very unevenly distributed. Examples include a mangled new antibody name that lands in the wrong drug class, a dropped "plus bevacizumab" that turns a combination regimen into monotherapy, a lost "negative," or a misheard PD-L1 percentage. Word error rate, the standard ASR metric, counts all of these the same as a mistranscribed "um."
We propose to measure this propagation end to end for combination-immunotherapy outcome prediction. We then test a specific fix. Rather than correcting the transcript and committing to one reading, the pipeline keeps the recognizer's alternative hypotheses and restricts them to regimens that actually exist. It extracts features from each surviving hypothesis and averages the outcome prediction over them. The claim is that this uncertainty-carrying pipeline recovers more of the clean-data performance, and gives better-calibrated risk estimates, than the strongest text-correction approach. It should also be cheaper.
Core Claim
Two claims, both falsifiable. First, downstream prognostic harm from ASR is concentrated in a small set of "consequential slots": checkpoint agent and its class, combination partner, negations about prior therapy and biomarkers, and numeric biomarker values. WER therefore predicts that harm poorly. Second, most of the lost discrimination and calibration can be recovered without generating corrected text. The pipeline propagates a distribution over slot values into the predictor, where $y$ is the outcome (response, or survival risk), $a$ is the audio, $\hat{x}_k$ is the feature vector extracted from the $k$-th ASR hypothesis, and $w_k$ is that hypothesis's recognizer score renormalized over the hypotheses whose extracted regimen is valid under a regimen knowledge base:
$$ p(y \mid a) \approx \sum_{k \in \mathcal{V}} w_k \, p(y \mid \hat{x}_k), \qquad \sum_{k\in\mathcal{V}} w_k = 1 . $$
Here $\mathcal{V}$ is the set of regimen-valid hypotheses. The regimen constraint matters because combination immunotherapy has a small, structured space: a checkpoint antibody plus chemotherapy, an anti-angiogenic, or a second checkpoint agent. A misheard name that yields no valid regimen is evidence against that hypothesis.
Why this intersection, and what already exists
The downstream side comes from Boosting Transformers and Language Models for Clinical Prediction in Immunotherapy. That work turns tabular MSK-IMPACT records into sentences ("The {attribute} is {value}.") and trains transformers, including a tabular transformer called ClinTaT, to predict response and survival under checkpoint blockade. It assumes perfectly curated inputs. We reuse its models and cohort as the prediction target and replace the curated inputs with speech-derived ones.
The motivating evidence that inputs will be noisy comes from Speech Recognition for Medical Conversations. It reports 18.3% WER for its best conversational model, higher error for patient speech (23.3%) than doctor speech (17.4%), and notably higher error in Oncology than in Dermatology or Urology. It also reports 98.2% medication-name recall, which constrains our framing. Common drug names may already be heard well, so the open question is whether that holds for recently approved agents such as camrelizumab, finotonlimab, benmelstobart and anlotinib. These agents appear in the combination trials CameL 5-year outcomes, Finotonlimab plus SCT510 in HCC and Benmelstobart, anlotinib and chemotherapy in ES-SCLC. A related open question is whether omission errors on combination partners behave like substitutions. Measuring Domain Portability and Error Propagation in Biomedical QA shows the general pattern we expect: swapping gold for automatically retrieved inputs in a biomedical pipeline cost 7–14 absolute points. That error source was retrieval, not speech, and the downstream task was QA, not prognosis.
The correction methods we compete against come from two lines. ASR Error Correction Using Large Language Models uses language models on N-best lists and lattices. It shows that constraining output to the recognizer's hypotheses curbs hallucinated edits, but it is evaluated only on general speech and by WER. Contextual ASR Error Handling with LLMs Augmentation for Goal-Oriented Conversational AI re-ranks hypotheses against expected dialogue states with a phonetic-similarity fallback. It relies on rigid state trees from smart-home tasks. On the clinical side, Error Correction in Radiology Reports corrects speech-to-text slips in radiology reports with staged detection, localization and correction plus knowledge-graph and retrieval context, working on text alone with one injected error per report.
Our proposal borrows the hypothesis-space constraint from the first and the domain-knowledge constraint from the third. It differs from all three in two ways. It never commits to a single corrected string. It is evaluated by what happens to survival and response predictions, not by transcript accuracy.
No study in the file connects spoken clinical transcription to immunotherapy prediction. The closest work is the ClinTaT paper, which assumes clean inputs, and the medical-ASR paper, which stops at WER.
Research Program
Building a paired benchmark. No public oncology consultation audio with outcome labels is available to us, so we construct paired data. For each MSK-IMPACT patient (1,184 train, 295 test), we render the structured features into a short scripted consultation passage. Templates are paraphrased by a language model and reviewed by an oncologist. Each passage includes the regimen, prior lines, biomarker statements with negations, and numeric values, split between a "doctor" and a "patient" turn. We synthesize speech with multiple text-to-speech voices and add ambient noise. The noise level is calibrated so that off-the-shelf recognizers land in the 18–23% WER range reported for real medical conversations. A subset of roughly 200 scripts is re-read by human speakers so we can check that the synthetic error profile matches human speech on the consequential slots. The central validity risk is that synthetic audio errs differently from real clinics. The human subset exists to quantify that risk, and we will report results separately on it.
Extraction and prediction. A slot extractor maps each hypothesis to the feature schema. We use a span-based clinical tagger of the kind that led the Named Clinical Entity Recognition Benchmark, where gliner-multitask-large reached 65.67 span F1 versus 53.35 for GPT-4o. The same benchmark found weaker performance on measurements than on drugs and conditions, which predicts that numeric biomarkers will be a major failure slot. The extracted features feed ClinTaT, the serialized PubMedBERT model, and XGBoost, all trained on clean features as in the original work.
Regimen knowledge base. This is a small table mapping agent names and common mispronunciations to drug class, and listing clinically valid combinations. Examples are anti-PD-1 plus platinum-pemetrexed, and anti-PD-1 plus anti-VEGF. It is built from trial reports such as those cited above.
Harm attribution. For each slot, we swap in the gold value while leaving the rest of the transcript noisy. This measures how much of the AUC and C-index drop that slot explains, and tests whether WER or slot-level error better predicts harm.
Baselines
The ceiling is the clean-feature pipeline. On MSK-IMPACT, ClinTaT reports a pan-cancer response AUC of 0.815 and an overall-survival C-index of 0.724, against 0.796 AUC and 0.688 C-index for XGBoost (Boosting Transformers and Language Models for Clinical Prediction in Immunotherapy). We re-run these on the same split to get our own reference, since everything below is judged as a fraction of the gap between this ceiling and the naive floor.
The naive reference point is 1-best transcript, extractor, predictor, with no correction. This is what a straightforward ambient-scribe integration would do. It defines the floor.
The strongest existing correction method is N-best-constrained language-model correction following ASR Error Correction Using Large Language Models. A fine-tuned sequence-to-sequence corrector is trained on our training-split transcripts, and a zero-shot large model is also tried, both restricted to the recognizer's 10-best list. The corrected 1-best string then goes through the same extractor and predictor. That paper reports up to 38.4% oracle WER improvement with 10-best lists on LibriSpeech. No reported result on Lacuna exists for this method on clinical or oncology speech, or for its downstream prognostic effect. We also run a clinical-knowledge text corrector in the style of Error Correction in Radiology Reports, with its retrieval component drawing from training-split scripts. All correctors receive the same N-best lists, the same extractor and predictors, and a matched hyperparameter search budget.
Two ablations isolate our ingredients. The first applies the regimen constraint but takes the single highest-scoring valid hypothesis, testing constraint without averaging. The second averages over all hypotheses without the regimen filter, testing averaging without constraint.
Beating the strongest baseline means recovering a larger share of the ceiling-to-floor gap in both AUC and C-index on the held-out 295 patients, with bootstrap confidence intervals, and showing lower expected calibration error on response probability. Matching discrimination while improving calibration would still be a meaningful but narrower result.
Why not just…?
Why not just bias the recognizer with an oncology drug vocabulary? This is the most serious threat. Adding a custom vocabulary to the recognizer is cheap and may fix most agent-name substitutions, especially given the 98.2% medication recall already reported in Speech Recognition for Medical Conversations. We run a vocabulary-biased recognizer as an additional baseline and apply our method on top of it. Biasing addresses in-vocabulary substitutions but not dropped combination partners, lost negations, or misheard numbers. If the harm-attribution analysis shows that agent-name errors account for most of the degradation and biasing removes them, we will report that the simpler fix suffices and narrow the claim to the residual slots.
Why not just take the regimen from pharmacy orders instead of speech? For drugs administered in-house, orders are cleaner, and our experiments should not pretend otherwise. Prior lines given elsewhere, reasons for stopping treatment, and patient-reported toxicities often exist only in conversation. The benchmark will therefore report results separately for slots that plausibly have a structured source and those that do not. The practical claim rests on the latter.
Why not just let a large model correct the transcript zero-shot? The file's evidence argues against unconstrained correction. General-purpose models trail specialized extractors on clinical entities, with GPT-4o at 53.35 versus 65.67 span F1 in Named Clinical Entity Recognition Benchmark. Unconstrained decoding also produced unwanted edits in ASR Error Correction Using Large Language Models. We still include zero-shot unconstrained correction as a baseline, because a strong model with oncology knowledge might repair names well. The comparison will show whether it does, and the rate of hallucinated regimens is reported explicitly.
Why not just train the predictor on noisy features? Noise augmentation, meaning training the predictor on features extracted from noisy transcripts, is a standard hardening strategy. We run it as a baseline: ClinTaT retrained on training-split noisy features. It may help discrimination, but it teaches the model to hedge on every patient rather than on the specific patients whose audio was ambiguous. That should show up as worse per-patient calibration than averaging over hypotheses. Averaging can also be applied on top of the augmented model, so we report the combination too.
Proposed Experiments
The first decisive check is whether the problem exists at the scale claimed. It compares ceiling and floor AUC and C-index across the three predictors, using both synthetic and human-read audio. It also regresses the per-patient change in predicted risk on transcript WER versus on counts of errors in consequential slots. If WER explains the harm as well as slot errors do, the first claim fails.
The second check is the head-to-head described under Baselines, broken down by doctor versus patient turns and by cancer type. The patient-turn breakdown tests whether the reported doctor/patient WER gap carries through to prediction.
The third check is a targeted stress test on combination regimens. We hold out scripts mentioning newly approved agents never seen by the corrector during training, drawn from the CameL, finotonlimab–SCT510 and benmelstobart–anlotinib trials. We measure regimen-class accuracy and downstream risk shift. This is where regimen-constrained averaging should help most and fine-tuned correctors should generalize worst.
All results will be reported with the synthetic-versus-human gap stated alongside, so that conclusions drawn from synthetic audio can be weighed against it.
References
- Boosting Transformers and Language Models for Clinical Prediction in Immunotherapy
- Speech Recognition for Medical Conversations
- Camrelizumab plus carboplatin and pemetrexed as first-line therapy for advanced non-squamous non-small-cell lung cancer: 5-year outcomes of the CameL randomized phase 3 study
- Finotonlimab (PD-1 inhibitor) plus bevacizumab (bevacizumab biosimilar) as first-tier therapy for late-stage hepatocellular carcinoma: a randomized phase 2/3 trial
- Benmelstobart, anlotinib and chemotherapy in extensive-stage small-cell lung cancer: a randomized phase 3 trial
- Measuring Domain Portability and Error Propagation in Biomedical QA
- ASR Error Correction Using Large Language Models
- Contextual ASR Error Handling with LLMs Augmentation for Goal-Oriented Conversational AI
- Error Correction in Radiology Reports: A Knowledge Distillation-Based Multi-Stage Framework
- Named Clinical Entity Recognition Benchmark