Calibration Loads: Testing Whether Self-Reports Collapse Across People

When engineers test a 1:4 steel plate and a full-size one, the raw force readings disagree. Once force is divided by the material's flow stress and the plate thickness, though, the curves fall on top of each other. That overlap, called "curve collapse," is the evidence that the small model is a valid stand-in. Self-reported fatigue, mood, and workload pose the same problem in a human form. One person's "8/10" is another's "5/10" for the same underlying state, because each person reads the rating scale differently. Wearable-sensing studies mostly treat these ratings as ground truth anyway. We propose to import the engineers' discipline directly. For each person, we estimate a mapping from internal state to reported number, and we estimate it only from episodes where the objective "load" on that person is known: a controlled task-difficulty level, a night shift, a measured loss of sleep. We then ask a falsifiable question: once each person's ratings are converted back into common units, do their dose-response curves collapse onto one curve?

The payoff is twofold. If the curves collapse, there is finally a principled way to compare self-reports across people, and models that predict one person's reports from sensors should transfer to unseen people. Today they fail badly, falling from 72.33% to 46.13% accuracy when moved to new subjects on the MOCAS workload task. If the curves do not collapse, the structured part of what is left over measures the person-specific reporting bias itself. This is the quantity the self-report literature describes in words but rarely isolates in data.

Core Claim

A self-report is a measuring instrument whose scale is distorted differently for each person. That distortion can be identified, without circular fitting, from a small number of calibration loads whose objective magnitude is shared across people. Write $x_{it}$ for the objective load on person $i$ at time $t$, $s_{it}$ for the latent state, $r_{it}$ for the reported rating, $f$ for a shared population dose-response, $g_i$ for person $i$'s monotone response map, and $u_{it}, \epsilon_{it}$ for state and reporting noise. The model is

$$s_{it} = f(x_{it}) + u_{it}, \qquad r_{it} = g_i(s_{it}) + \epsilon_{it}.$$

The similitude-style step is that $g_i$ is fit only on calibration episodes, where $x$ is known and comparable across people. It is never fit on the outcome episodes we later evaluate. Collapse is then a measurable criterion. We compute the across-person spread $D_{\text{between}}$ of the back-transformed curves $g_i^{-1}(r)$ versus $x$ on held-out episodes, and compare it with the within-person split-half spread $D_{\text{within}}$, which serves as the noise floor:

$$C = \frac{D_{\text{between}}}{D_{\text{within}}}.$$

A value of $C$ near 1 means people are indistinguishable once their scale is corrected. A value well above 1 means some distortion is left that a single monotone map cannot absorb.

What is new is not the use of person-specific effects, which mixed-effects models already have. What is new is how $g_i$ is identified (from shared physical loads, held apart from the evaluation data) and how the result is tested (explicit collapse against a noise floor, rather than only predictive error).

Grounding in Prior Work

The method comes from scaled physical modeling. Numerical and Experimental Research on Similarity Law of the Dynamic Responses of the Offshore Stiffened Plate Subjected to Low Velocity Impact Loading dropped weights on 1:1, 1:2, and 1:4 stiffened plates. It showed that force normalized by flow stress and thickness, and deflection normalized by thickness, agree across scales to within 5% and 1% respectively. We borrow its validation logic of using an independently known constitutive quantity to normalize and then checking residual disagreement. We do not borrow its specific ratios, since human bodies are not plates.

Model Experiments on Slamming and Hull Girder Responses of a Bulk Carrier in Fully loaded Condition using Elastic Model Technique separated slow rigid-body ship motion from fast elastic whipping by building a calibrated internal backbone. We reuse that separation in a modest form. Calibration loads are defined on slow, shift-scale contrasts, and the collapse test is run separately on slow and fast components. This lets us check whether reporting distortion depends on timescale.

That same literature also limits the design. The basic open problem of similitude is that Froude and Reynolds scaling cannot be satisfied at the same time. The analog is that one monotone $g_i$ may not be able to correct for both recall bias and social desirability. So we treat failure of collapse as informative, not as a bug.

The motivation comes from wearable-sensing work that pairs sensors with self-reports. A multimodal analysis of physical activity, sleep, and work shift in nurses with wearable sensor data found night-shift nurses with a social jet lag of 425 minutes versus 52.5 for day nurses, yet shift pattern did not correlate with daily affect or anxiety reports. A huge objective load produced no visible subjective signal, which is exactly what person-specific scale distortion would produce. MOCAS: A Multimodal Dataset for Objective Cognitive Workload Assessment on Simultaneous Tasks supplies the cleanest calibration loads in the file: nine controlled workload levels with NASA Task Load Index ratings. It also shows the cross-subject collapse from 72.33% to 46.13%.

Towards Automated Fatigue Assessment using Wearable Sensing and Mixed-Effects Models shows that person and demographic effects matter. Random-forest mixed-effects models clustered by age and BMI reached an RMSE of 1.78 ± 0.13 and a correlation of 0.75 on 21 people. Those effects, however, were fit to the outcome rather than identified from known loads.

BALMS: Benchmarking Agentic LLMs for Longitudinal Mental Health Sensing documents a "mean barrier": zero-shot language-model agents fail to beat predicting the average. Its tool-using agents invent population thresholds such as steps > 20000 that ignore personal history, which is the failure a per-person response map is meant to prevent.

The work that most directly invites a reinterpretation is Assessing Real-Time Moderation for Developing Adaptive Mobile Health Interventions for Medical Interns: Micro-Randomized Trial. Its notifications helped only when mood was below 7, with a moderation estimate of −0.052 and P = .001. Above that threshold the same nudge lowered reported mood. A fixed tipping point on a raw 1–10 scale is just what a ceiling in each person's response map would produce. That makes the paper both a motivation and a testable target.

Research Program

The first component is a calibrated ordinal response model. Each person's $g_i$ is a monotone, threshold-based map, the same structure as an ordinal regression with person-specific cut points. Its parameters are shrunk toward a population prior so that a few calibration episodes suffice.

The second component is the choice of calibration loads in each dataset:

  • MOCAS: the nine designed workload levels.
  • TILES-2018: within-person contrasts between workdays and off-days, and between night and day shifts, quantified by sleep minutes and mid-sleep shift. The data come from TILES-2018 Sleep Benchmark Dataset and the nurse cohort above.
  • PMData and GLOBEM: naturally occurring large sleep-loss nights, using a fixed definition chosen before outcome analysis.
  • Homekit2020: the same sleep-loss and activity-surge definitions applied at scale (5,034 participants).

The third component is the collapse test. We compute $C$ per dataset, per construct (fatigue, mood, workload), and separately for slow and fast components.

The fourth component is downstream use. The back-transformed state $g_i^{-1}(r)$ replaces the raw rating as the training target for any sensor model. For unseen people, $g_i$ is estimated from their first few calibration episodes and predictions are mapped back to their scale.

The fifth component is the bias residual analysis. Where $C$ stays well above 1, we test whether the leftover structure lines up with constructs the self-report literature predicts. Examples are the personality traits MOCAS records and the expected inflation of positive scales after therapy engagement described in the ACT versus MBSR randomized trial. That alignment is a hypothesis we will test, not an assumption.

Baselines

The naive reference point is predicting each dataset's training mean. BALMS reports this at 0.58 MAE on DiversityOne. No reported result was found on Lacuna for the mean baseline on PMData or GLOBEM, so we will compute it ourselves. The second naive reference is the pooled model trained on raw ratings with no person adjustment.

The strongest within-dataset deep baseline on MOCAS is the late-fusion LSTM of MOCAS. It reports 72.33% three-class accuracy within subject and 46.13% under leave-one-subject-out. We rerun it with per-subject z-scoring of both features and ratings, using the same splits. Our method beats it if, under leave-one-subject-out with the same k calibration trials given to both systems, it closes a substantial part of the gap toward the within-subject number. It must do this for both workload-class accuracy and NASA Task Load Index prediction error.

On Homekit2020 the strongest reported system is self-supervised pre-training with domain features and all data augmentations, from Systematic Evaluation of Self-Supervised Learning Approaches for Wearable-Based Fatigue Recognition. It reports AUROC 0.7470 and AUPRC 0.0627. We keep that encoder fixed and change only the training target, from raw fatigue labels to calibrated ones. A gain in AUPRC with the same encoder, data, and tuning budget therefore isolates the contribution of the label correction.

The mixed-effects competitor is MERF from Towards Automated Fatigue Assessment using Wearable Sensing and Mixed-Effects Models, which reports RMSE 1.78 ± 0.13. We run it with person-level random effects, not only demographic clusters, with an equal hyperparameter search.

The decisive ablation is our own model with person-specific cut points fit on all available rating data rather than on calibration episodes only. A second ablation uses calibration loads shuffled across episodes. If the first ablation matches the full method, then the similitude ingredient adds nothing beyond ordinary personalization, and we will say so.

Why not just…?

Why not just z-score each person's ratings? Z-scoring divides by each person's rating variance. That variance mixes how much the person's state actually varies with how widely they use the scale. A person who truly had a calm month gets inflated, and a person with a turbulent month gets shrunk. Anchoring on a shared known load separates the two quantities. The MOCAS cross-subject collapse occurred despite normalized features, which suggests linear standardization is not enough. Still, z-scoring is a real competitor, and it is run with identical calibration data in every comparison. If it achieves the same collapse ratio $C$ as our method, the claim fails.

Why not just fit a mixed-effects model with person-specific slopes and thresholds? Structurally, this is close to our model. The difference is identification. Fitting person effects on the outcome being predicted absorbs real between-person differences in state into "bias." Fitting them only on calibration loads does not. The full-data cut-point ablation is precisely this alternative. On held-out people, it is the experiment that settles whether separate identification matters. We expect it to matter most where state truly differs between people, such as night versus day nurses, and least in MOCAS, where everyone receives the same designed loads.

Why not just personalize a large pre-trained sensor model with a few labels per new person? Few-shot fine-tuning can learn a person's rating offset, but it learns that offset jointly with everything else from a handful of noisy labels. It also yields no interpretable estimate of reporting distortion. We give the fine-tuned self-supervised encoder the same k labeled episodes per new person. If it matches our prediction accuracy, the predictive benefit of the proposal disappears. What would remain is the collapse test and the bias residual analysis, which fine-tuning cannot provide. We would then report the work as a measurement contribution, not a prediction one.

Decisive Experiments

The first check runs on MOCAS. Here loads are designed, so it is the closest analog to the drop-weight tower. Collapse ratio $C$ should approach the split-half floor after calibration and stay clearly above it for raw and z-scored ratings. Leave-one-subject-out performance should improve over the 46.13% reference given equal calibration trials.

The second check runs on TILES and examines the null correlation between shift pattern and affect. If, after calibrating each nurse's response map on their own workday-versus-off-day contrasts, night-shift load now predicts calibrated anxiety or affect, then the original null was a measurement artifact. If it still does not, the decoupling is genuine.

The third check runs on Homekit2020. Same encoder, calibrated versus raw labels, compared against the reported AUPRC of 0.0627.

The fourth check concerns the intern trial's mood threshold of 7, and is conditional on data access. The file does not indicate whether Intern Health Study data are public. If accessible, we re-estimate the moderation effect in calibrated units. A tipping point that disappears or moves substantially would show that part of the reported "backfire" lives in the rating scale rather than in behavior.

A result counts against the whole idea if two things happen together: calibrated collapse is no better than z-scoring, and the full-data cut-point ablation matches the calibration-identified model.