Calibrating 5σ Subspace Detectors When the Noise Floor Drifts

Many detection problems share one structure. A sensor array records a high-dimensional noise vector made of a few strong correlated components (coherent pickup across channels, or radar clutter) on top of electronic noise. The detector asks whether a known signal shape is hidden in a new recording. To answer, it estimates the strong noise directions from a set of signal-free "reference" recordings and projects them out. Random matrix theory, the study of eigenvalues of large random matrices, shows that this projection is systematically wrong when the number of channels is comparable to the number of reference recordings. The resulting false-alarm rate then depends on quantities nobody knows. A correction exists for the textbook case in which every reference recording has the same noise level. Real rare-event detectors violate that assumption. Their electronic noise floor drifts from window to window, and that drift is exactly what forces analysts to use short, recent reference sets in the first place.

This proposal derives, implements and stress-tests a subspace detector whose false-alarm rate stays fixed when the reference noise level varies across recordings. The test is made at the false-alarm level physicists actually use for discovery, 5σ (a probability of $2.87\times10^{-7}$), rather than the 1–10% levels where signal-processing corrections are usually checked. The central question has two parts. The first is how badly the existing correction, built for equal noise levels, miscalibrates the far tail under realistic drift. The second is how large the array and reference set must be before any asymptotic correction can be trusted at 5σ.

Core Claim

The setting is the spiked covariance model: noise covariance equals a flat background plus a few isolated strong directions ("spikes"). An Improved Low Rank Detector in the High Dimensional Regime studies the low-rank adaptive normalized matched filter in this model. That detector projects the estimated spike directions out of both the template and the test vector, then measures their normalized alignment. The paper shows the filter loses its constant-false-alarm-rate (CFAR) property when the channel count $M$ and reference count $N$ grow proportionally. It also gives a corrected statistic whose null distribution converges to a central $\chi^2(2)$. That analysis assumes homoscedastic Gaussian disturbance, meaning every recording has the same noise level.

Asymptotic performance of PCA for high-dimensional heteroscedastic data studies the other side. It treats the case where noise variance differs across samples while the low-rank component is shared, and derives closed-form rational equations for how well sample eigenvectors align with the true ones. It shows this heteroscedasticity strictly worsens recovery relative to equal noise of the same average. In one configuration, 82% subspace recovery under uniform noise becomes 0% under heteroscedastic noise. That paper studies estimation only, not hypothesis testing.

Our claim has three parts. First, plugging the average noise level into the homoscedastic correction produces a false-alarm rate at 5σ that is biased by a factor which grows with the spread of the per-window noise levels. The bias at 5σ is much larger in relative terms than the bias at conventional levels, because a small error in the null scale gets amplified exponentially in a $\chi^2$ tail. Second, the corrected detector re-derives the bias factor using the heteroscedastic alignment functions of Hong et al. This should restore a flat false-alarm rate across signal directions and drift profiles. Third, even the corrected detector has a finite-size tail error. We will map the $(M, N)$ region where its 5σ calibration is accurate within a factor of two. That map is a practical "sensitivity limit" statement, and as far as we can find no paper in either literature provides one.

Research Program

The model for reference recordings is $z_i = U\Theta^{1/2} a_i + \eta_i \varepsilon_i$ for $i = 1,\dots,N$. Here $U$ is the $M\times K$ matrix of coherent noise directions, $\Theta$ holds their strengths, $a_i$ and $\varepsilon_i$ are independent standard Gaussian vectors, and $\eta_i^2$ is the electronic noise level of window $i$. The drift profile is the empirical distribution of the $\eta_i^2$. When all $\eta_i$ are equal, this reduces to the setting of Vallet et al.

The first piece is theory. We will compute the deterministic limit of the bias term $s^\top \hat\Pi s$ and its cross terms, where $\hat\Pi$ is the sample projector orthogonal to the top-$K$ sample eigenvectors and $s$ is the template. We take the eigenvector alignment from the rational equations of Hong et al. in place of the Marchenko–Pastur alignment functions used by Vallet et al. We then form a corrected statistic. This also requires estimating the drift profile. Per-window noise power is observable from each reference recording's residual energy outside the top-$K$ subspace. We will analyze how errors in that estimate propagate into the correction. We will also state the non-central distribution under the alternative, which Vallet et al. omit; it gives detection probability at fixed 5σ threshold.

The second piece makes tail validation cheap. Brute-force checking a $2.87\times10^{-7}$ false-alarm rate needs on the order of $10^9$ null trials per configuration. We avoid that by conditioning. Given a fixed reference set, the statistic under Gaussian test noise is a ratio of quadratic forms in one Gaussian vector. Its exact conditional tail probability can therefore be computed numerically by standard characteristic-function inversion. Averaging this exact conditional probability over a few thousand reference-set draws gives the unconditional 5σ false-alarm rate with tight error bars. As a side product, the same computation reports the spread of the conditional false-alarm rate across reference sets. Analysts actually live with that conditional rate, because they run with one specific reference set.

The third piece is a physics-facing injection study. The motivating case is a multichannel scintillation array such as the 74 avalanche-photodiode readout of EXO-200. It records 350 time samples per channel, as documented in Generative adversarial networks for scintillation signal simulation in EXO-200. There, coherent noise across channels plays the role of the spikes, and a light-map-weighted pulse template plays the role of $s$. The deliverable is the lowest injected pulse amplitude detectable at 90% efficiency with a false-alarm rate certified at 5σ. In practical terms, this is the trigger threshold. It is computed as a function of reference-window length under realistic drift.

Baselines

The naive reference point is the classical low-rank adaptive normalized matched filter with a $\chi^2$-type threshold. It is the detector Vallet et al. show to be miscalibrated, and it shows how large the problem is if nothing is done. The strongest existing method is the HD-LR-ANMF correction of An Improved Low Rank Detector in the High Dimensional Regime, run with the average estimated noise level. That paper reports a flat false-alarm rate across arrival angles at $M = N = 20$ and $40$ with $K = 3$. It reports no numerical false-alarm values in the material available to us, and no reported result was found on Lacuna for its 5σ calibration. We will therefore first reproduce its homoscedastic curves as a sanity check, then evaluate it under drift.

The third baseline is per-window power normalization: rescale each reference recording to unit residual power, then apply the HD-LR-ANMF correction. This is the obvious engineering fix, and the strongest simple competitor. The ablation that isolates our key ingredient swaps only the alignment functions while keeping everything else identical, including the estimated drift profile. If that ablation does not move the 5σ calibration, the heteroscedastic theory is not doing the work.

All detectors receive the same reference sets, test vectors, rank $K$ and template. None has a tuning parameter beyond $K$, which is fixed to the true value in the main grid and estimated in a robustness run. Beating the strongest baseline means a 5σ false-alarm rate within a factor of two of nominal across every drift profile and signal direction tested, where HD-LR-ANMF falls outside that band. It also means equal or better detection probability at the calibrated threshold.

Why not just…?

Why not just calibrate the threshold empirically from abundant noise-only recordings? If the noise is stationary and one can record millions of signal-free windows, empirical calibration works, and our method adds nothing. That case does not need random matrix theory at all, since $N \gg M$. The regime we target is the one where drift forces short reference windows. In that regime the threshold must be set for the specific, small reference set in use, and the empirical tail at $10^{-7}$ cannot be estimated from that set. The conditional false-alarm spread computed in the research program measures directly how much an empirically fixed threshold misses on a given reference set. The injection study will report the window length at which drift makes empirical calibration fail, so readers can see whether their own detector sits in our regime.

Why not just normalize each reference window by its noise power and use the existing correction? This is a real threat. If drift only rescales whole recordings, normalization reduces the problem to the homoscedastic case. In our model, however, drift affects only the electronic component while the coherent component stays fixed. Normalizing therefore distorts the spike strengths window by window. Hong et al. also note that inverse-variance weighting is not optimal for subspace recovery in high dimensions. The ablation settles the question. If normalization matches our detector's 5σ calibration across drift profiles, we will report the result as that and narrow the contribution to the finite-size tail map, which remains new regardless.

Why not just train a neural classifier on the waveforms, as EXO-200 did? The deep network in Search for Neutrinoless Double-β Decay with the Complete EXO-200 Dataset improved sensitivity by about 25% over topological cuts. It also raised signal efficiency to 96.4 ± 3.0%. But its false-alarm rate is established by Monte Carlo, with no guarantee at 5σ, and it solves a classification problem at the analysis stage, not threshold detection against drifting noise. We treat it as complementary rather than competing, and we do not claim our linear detector beats it on classification.

Why not just use the bootstrap to set the threshold? El Karoui et al. show the bootstrap fails for eigenvalues inside the noise bulk. Our tail grid will include near-threshold spikes, where we expect the bootstrap threshold to fail visibly.

Proposed Experiments

The synthetic grid uses $M \in \{20, 40, 80, 160\}$, $N/M \in \{1, 2, 4\}$ and $K \in \{1, 3\}$. Spike strengths straddle the detectability threshold, including near-threshold settings. Drift profiles are two-level with variance ratios from 1 to 10, plus log-normal. Signal directions are swept as in the Vallet arrival-angle test. The primary metric is the ratio of actual to nominal false-alarm rate at 5σ, computed with the conditional-tail method, alongside the same ratio at $10^{-2}$. Secondary metrics are detection probability at the calibrated 5σ threshold and the across-reference-set spread of conditional false-alarm rates.

Three checks are decisive. The first: under equal noise levels, our detector and HD-LR-ANMF must agree, otherwise our derivation is wrong. The second: under drift, HD-LR-ANMF's 5σ ratio should leave the factor-of-two band while ours stays inside it. The third: the finite-size map should show where both fail, and whether that boundary moves with $K$ as theory predicts.

The physics-facing test uses EXO-200 thorium-228 calibration waveforms, 215,789 events, if collaboration access is obtained. Noise-only segments would serve as reference sets and pulses would be injected. Without access, we fall back to semi-synthetic waveforms whose coherent-noise spikes and drift profile are fitted to published detector characteristics. We will say plainly that this fallback tests the method's internal consistency, not its value for a real experiment. The outcome measure is the trigger-amplitude threshold at certified 5σ versus reference-window length, compared across all four detectors.