Most machine learning on phone and wearable data treats a person's survey answers as the truth. When someone answers "how depressed have you felt this week" on a short questionnaire, that score becomes the label a model is trained to predict from their sleep, steps, and phone use. Psychology has long documented that these answers are biased in structured ways. People recall the past through their current mood, shade stigmatized answers toward the socially acceptable, and tell trial staff what they seem to want to hear. We propose to turn the comparison around: use the passive sensor stream as a reference against which individual survey answers can be checked. The tool is reconstruction-based anomaly detection, a family of methods that learns what normal data looks like, rebuilds each new input as its closest normal version, and flags whatever fails to rebuild. Applied here, the model learns how a given person's reports usually relate to their own behavior. It rebuilds what that person's answer would typically be, given this week's telemetry and their other answers, and flags reports that deviate in a structured way.
The obvious version of this idea has a real flaw, and the proposal is organized around fixing it. Sensors explain only a modest share of reported mood: the best within-cohort depression models on the GLOBEM benchmark reach balanced accuracy of 0.691, and cross-year transfer falls toward chance (GLOBEM Dataset). So a large gap between "what the sensors predict" and "what the person said" will usually reflect true feelings the sensors cannot see, not distortion. Our contribution is therefore a detector together with a way to measure when such a detector can be trusted. We separate stable reporting style, which we deliberately absorb, from episode-level distortions, which we try to flag. We check flags against reference signals already inside existing cohorts, and we report how detection power depends on how predictable each person's reports are from behavior.
Core Claim
A masked reconstruction model, conditioned on a person's own recent history, can detect episode-level self-report distortions. Here "masked" means that some survey items are hidden and must be filled in from the sensors, the remaining items, and the person's own past weeks used as context. We consider three kinds of distortion: retrospective recall drift, careless or straight-lined responding, and short-lived inflation or deflation. The model should detect these better than a person-centered linear residual model, provided two conditions hold. Training must be made robust to the contamination that unmonitored survey data inevitably contains, and the score must be the residual of each item scaled by the model's own predictive uncertainty, not a single scalar error. We expect the gain to depend on the data. Where a person's reports are well predicted by their behavior, telemetry should add detection power beyond within-questionnaire consistency. Where they are not, the method should say so by reporting low confidence instead of raising false flags. If sensors add nothing over item-only reconstruction, the "wearables audit self-report" claim is false. We treat that as a possible and publishable outcome.
Research Program
The data unit is a person-week. It combines summarized passive features (sleep duration, efficiency, and latency; step counts; GPS travel distance; screen and call activity) with item-level self-report responses (the four weekly PHQ-4 items in GLOBEM, and the BDI-II items when a seasonal survey falls in that window). Several lines of work supply the method. CORE reconstructs a tabular query from retrieved normal examples supplied as context and scores the failure to reconstruct. We reuse that design, except that the retrieved context is the same person's earlier weeks rather than other people's records. This choice absorbs stable traits, such as someone who always answers two points low, which no model could separate from their true level anyway. It concentrates the score on departures from that person's own relation between behavior and report. AttentiveGRUAE shows that a recurrent autoencoder can learn stable latent structure from GLOBEM sleep streams, but it uses reconstruction only as a helper objective and treats BDI-II and PHQ-4 as clean labels. We use its encoder style for the sensor history and change the target: survey items become things to reconstruct and audit, not supervision.
The item-level score for item $j$ in week $t$ is
$$ s_{t,j} = \frac{r_{t,j} - \hat{r}_{t,j}}{\hat{\sigma}_{t,j}}, $$
where $r_{t,j}$ is the reported value, $\hat{r}_{t,j}$ is the model's reconstruction with that item masked, and $\hat{\sigma}_{t,j}$ is the model's predicted spread for that item. The predicted spread comes from a heteroscedastic output head, meaning a second output that estimates how uncertain each prediction is. Dividing by it is what lets the method stay quiet for people whose mood the sensors cannot track. The sign and pattern of $s$ across items carry the diagnosis. All items shifting together in one direction while sensors stay flat is a candidate inflation or deflation episode. A retrospective instrument that disagrees with the concurrent weekly reports covering the same period is a candidate recall drift. Near-zero variance across items with large residuals is a candidate careless response. The mapping from these patterns to bias types is the most speculative part of the program, and we will test it rather than assume it.
Two lessons from anomaly detection set constraints on the design. Fixing Bias in Reconstruction-based Anomaly Detection with Lipschitz Discriminators shows that autoencoders memorize contaminated training points and lose detection ability at 1–3% contamination. It also shows that a 1-Lipschitz discriminator, a scoring network whose output is constrained to change smoothly with its input, stays robust under that contamination on VACS clinical data. Real survey data is contaminated by construction, so we train with that discriminator as the contamination-robust variant and also with iterative trimming of the highest-residual weeks. Audio-Anchored Fusion of Multi-Ratio DiT Reconstruction Residuals contributes two ideas we adapt. The first is multi-ratio masking: hiding 0.5, 0.75, or 0.9 of the input to probe reconstruction at several difficulty levels. The second is anchored fusion. When modalities compete for normalized attention weights, a shifted modality can push the others aside, and detection error in that paper rose above 25% EER. Anchoring a reliable representation at fixed weight avoids this. For us, the sensor encoding is the anchor and the survey channel enters only as an additive term, so a corrupted survey cannot suppress the behavioral signal. Expensive diffusion generators are unnecessary at weekly tabular scale. A small masked transformer or GRU suffices, which also sidesteps the latency problem that paper reports.
The self-report literature motivates which distortions to target. Recall distortion of somatic symptom histories (RECOVER-Adult), under-reporting of stigmatized behavior (Bergen Social Media Addiction Scale invariance), self-inflation on competence instruments (new nurses' work performance), and demand effects in trials (ACT vs. MBSR trial) all describe systematic, signed distortions rather than random noise. That is why we score signed residuals per item. None of these papers offers an instance-level detector, which is the gap this program fills.
Baselines
The naive reference point flags nothing and keeps every self-report as ground truth, which is what GLOBEM and AttentiveGRUAE do. Alongside it we run standard psychometric response-quality screens: a longstring or straight-line index and the within-person standard deviation across items. These are the checks survey researchers already use. Any proposed detector has to beat them on careless responding at least, because that is the distortion those screens were built for.
The strongest simple competitor is a person-centered linear mixed-effects model. It predicts each PHQ-4 item from the same weekly sensor features with person-specific intercepts and slopes, and flags large standardized residuals. This is the epidemiologist's default, in the spirit of the centered least-squares estimators used on Intern Health Study Fitbit and EMA data (NeCamp et al.). It also captures most of what "reconstruct the report from sensors" means in its simplest form. It receives exactly the same person-weeks, the same feature set, the same personal history window, and a matched hyperparameter search budget, and it is scored with the same uncertainty-scaled residual. Beating it means higher area under the precision-recall curve on the injected-distortion benchmark below for at least two of the three distortion types, with confidence intervals from person-level bootstrap that exclude zero difference. It also means stronger agreement with the real-data reference signals. If the mixed model ties, we will report that the deep reconstruction machinery is unnecessary.
The strongest existing reconstruction approach is CORE-style in-context tabular reconstruction across people. It reports an average AUROC of 0.8488 over 34 tabular anomaly datasets (CORE), though none of those datasets concerns self-report distortion. We found no reported result on Lacuna for detecting self-report bias against passive sensing on GLOBEM, IHS, or StudentLife, so no published number exists to beat on the target task. For the closest sensor-to-survey modeling numbers, AttentiveGRUAE reports depression AUC of 0.74 on GLOBEM 2018–2019 and 0.61 on 2020–2021 (AttentiveGRUAE). These numbers bound how much reported variance sensors can explain. We also include a vanilla autoencoder thresholded on mean squared error, and a supervised classifier trained on injected distortions.
Four ablations isolate the key ingredients. The first removes personal-history context and uses the population instead. The second removes contamination-robust training. The third replaces per-item uncertainty-scaled residuals with a single scalar error. The fourth, and most important, removes sensors entirely, so the model reconstructs survey items only from the person's other items and past reports. The gap between the full model and this item-only ablation is the direct measure of whether telemetry audits anything.
Why not just…?
Why not just use attention checks and straight-lining filters? They target inattention, and on careless responding they may well match us. We report that comparison directly rather than claim otherwise. They are blind by construction to conscientious but distorted answers, such as inflated competence ratings (new nurses' work performance) or mood-colored recall (RECOVER-Adult). Those answers are internally consistent and quickly given, and the injected recall and inflation conditions measure exactly this blind spot.
Why not just regress the report on the sensors and flag residuals? This is the real threat, because a person-centered mixed model is close to a linear version of our method. Our bet is that nonlinear sensor-to-mood relations and per-item uncertainty matter. AttentiveGRUAE's gains over simpler clustering and classification baselines on GLOBEM suggest some nonlinear structure exists, but that is not proof it helps auditing. The head-to-head comparison above, run at matched budget, settles it. If the linear model ties, the paper's contribution becomes the evaluation protocol and the evidence on when telemetry can audit self-report, not the architecture.
Why not just train a classifier on synthetic bias labels? CORE argues that framing anomaly detection as classification against synthetic outliers fails to generalize to real outliers (CORE), and DRÆM notes overfitting to the synthetic generator (DRÆM). We test this directly. The classifier is trained on two injected distortion types and evaluated on the held-out third, and on the real-data reference signals that no injection procedure produced.
Proposed Experiments
The first experiment is a controlled injection benchmark on GLOBEM (GLOBEM Dataset; cross-dataset paper). We take real person-weeks and inject three parameterized distortions into a known 5% of them. Recall drift reweights a retrospective score toward the final days of the window. Inflation or deflation shifts several items by a fixed amount while leaving sensors untouched. Careless responding replaces answers with straight lines or random values. Detectors are trained on data that already contains these injections, so contamination robustness is tested rather than assumed. We report precision-recall area under the curve per distortion type and per injection size. The critical analysis stratifies people by how well their held-out reports are predicted from sensors and plots detection power against that predictability. This is the "when can wearables audit" curve.
The second experiment tests against reference signals already present in the data, with no injection. In GLOBEM, the end-of-term BDI-II covers a window also covered by weekly PHQ-4 reports. For each person we compute how far the retrospective score departs from the reconstruction implied by their concurrent reports and telemetry. We then test whether that departure follows the recall pattern the self-report literature predicts, overweighting the final days, more strongly than the mixed-model residual does. In StudentLife (STGNN case study), we run the same comparison between pre/post PHQ-9 and daily EMAs, and test whether per-person discordance scores transfer from GLOBEM without retraining.
The third experiment uses the Intern Health Study's randomized push notifications (NeCamp et al.). Because notifications are randomly assigned, we can ask whether they shift reported mood more than they shift sleep and steps. That paper reports moderation effects on both mood and behavior, for example a mood moderation estimate of −0.052. A report-only shift in randomized notification weeks would be a candidate demand or reactivity effect. The proposed score should rise in those weeks relative to control weeks, beyond what the baseline residual shows. We state the caveat plainly: notifications can genuinely change mood without changing behavior, so this experiment yields supporting evidence, not proof.
The decisive checks are the following. The full model must beat the item-only ablation on the predictable stratum of the injection benchmark; otherwise sensors are not auditing anything. It must beat the person-centered mixed model at matched budget; otherwise the deep model is unwarranted. It must keep a low false-flag rate on the unpredictable stratum; otherwise uncertainty scaling has failed and the method would mislabel true feelings as bias. Finally, its retrospective-discordance scores must show the recall pattern on real GLOBEM data. Passing the first three supports a usable auditing tool. Passing only the last would still be a measured finding about reporting bias in a widely used benchmark, and would bear on whether part of GLOBEM's cross-year generalization drop comes from labels rather than behavior.
References
- GLOBEM Dataset: Multi-Year Datasets for Longitudinal Human Behavior Modeling Generalization
- CORE: In-Context Reconstruction for Unified Tabular Anomaly Detection
- AttentiveGRUAE: An Attention-Based GRU Autoencoder for Temporal Clustering and Behavioral Characterization of Depression from Wearable Data
- Fixing Bias in Reconstruction-Based Anomaly Detection with Lipschitz Discriminators
- Audio-Anchored Fusion of Multi-Ratio DiT Reconstruction Residuals for Cross-Domain Audio Deepfake Detection
- Incidence and Prevalence of Post-COVID-19 Myalgic Encephalomyelitis: A Report from the Observational RECOVER-Adult Study
- Measurement Invariance of the Bergen Social Media Addiction Scale Across Genders
- The effects of work readiness, organizational justice and professional identity on the work performance of new nurses: a cross-sectional survey
- Acceptance and commitment therapy versus mindfulness-based stress reduction for newly diagnosed head and neck cancer patients: A randomized controlled trial assessing efficacy for positive psychology, depression, anxiety, and quality of life
- Assessing Real-Time Moderation for Developing Adaptive Mobile Health Interventions for Medical Interns: Micro-Randomized Trial
- DRÆM - A discriminatively trained reconstruction embedding for surface anomaly detection
- GLOBEM: Cross-Dataset Generalization of Longitudinal Human Behavior Modeling
- Monitoring Behavioral Changes Using Spatiotemporal Graphs: A Case Study on the StudentLife Dataset