Many genes switch on and off on a daily cycle. To see whether a gene's protein also cycles, biologists measure both its RNA and its protein every few hours. The protein measurements, which come from mass spectrometry, are far noisier and more incomplete than the RNA sequencing. As a result, many proteins that truly cycle look flat.
Speech processing has handled a very similar problem for decades. The source–filter model treats the voice as a periodic buzz from the vocal folds (the source) shaped by the vocal tract (the filter). We propose to treat each protein's time course the same way: as that gene's RNA rhythm passed through a simple physical filter. Protein is made in proportion to RNA and degraded at a fixed rate. That kinetics predicts a strict link between how much a protein's rhythm is damped and how much it lags its RNA, and both are set by a single number, the protein's degradation rate.
With the rhythm's period estimated once for the whole dataset by pooling evidence across thousands of genes, testing each protein becomes a convex, calibrated statistical test. The alternative is a fragile per-gene nonlinear fit. The same model yields a second output that current methods cannot produce. Proteins whose rhythm cannot be explained as a filtered copy of their RNA get flagged, directly and testably, as rhythms generated after transcription.
Core Claim
The closest existing method is MOSAIC. It jointly fits RNA and protein time series with oscillator models that share one period while letting each layer's amplitude and phase vary freely. It showed that joint modeling rescues rhythms hidden by proteomic noise: over 300 newly oscillating proteins in Neurospora crassa, and up to 45 rescued proteins in its hardest synthetic settings. Its authors also report two problems. The joint nonlinear least-squares fit is non-convex and sensitive to initialization, and its false discovery rate rises under 6-hour sampling or single replicates.
We claim both problems come from giving the protein layer too much freedom. MOSAIC shares only the period. Our model also ties the protein's amplitude and phase to the RNA's through a one-parameter kinetic filter, with the filter parameter learned hierarchically across genes. This should raise detection power at a fixed, properly controlled false discovery rate in exactly the sparse-sampling regime where MOSAIC degrades.
The mechanism is standard first-order kinetics:
$$\frac{dP}{dt} = k\,R(t) - \gamma\,P(t) \quad\Longrightarrow\quad \hat P_h = \frac{k}{\gamma + i h\omega}\,\hat R_h .$$
Here $R$ and $P$ are RNA and protein abundance, $k$ is a translation-rate constant, and $\gamma$ is the protein degradation rate. The quantity $\omega = 2\pi/T$ is the angular frequency of a rhythm with period $T$. $\hat R_h$ and $\hat P_h$ are the complex Fourier coefficients (amplitude and phase) at harmonic $h$.
The filter implies that the protein's lag behind its RNA lies between zero and a quarter period, which is 6 hours for a 24-hour rhythm. Longer lags always come with stronger damping. A protein whose lag exceeds that bound, or whose damping does not match its lag, is "filter-inconsistent". It is a candidate for a rhythm with its own post-transcriptional driver, such as the 18.5% of the Neurospora proteome that MOSAIC reports oscillating independently of the transcriptome.
How the Pitch-Estimation Ideas Enter
Pitch estimation contributes three concrete pieces.
The first is pooling. SLASH regularizes a neural pitch estimator with a subharmonic-summation guide: harmonic evidence is added up across frequencies to pin down one fundamental, and its ablations show accuracy drops substantially without this guide. Dhiman et al. show how much harmonic structure can recover. They report 4.93% and 3.28% gross pitch error for male and female speech even over a telephone channel that removes the fundamental, against 99.43% and 26.68% for TEMPO. We apply the same logic across features rather than across frequencies. Each feature's periodogram at candidate periods and their harmonics is weighted by that layer's noise level, estimated from replicates. The weighted periodograms are summed over all genes in both layers to give one dataset-level period estimate with a bootstrap interval.
Once the period is fixed, each feature's model is linear in cosine and sine terms, so the non-convexity that MOSAIC reports disappears. This is also the role Hong and Wolfe's ARMA initialization plays in speech: it puts the hard nonlinear search onto a well-conditioned starting point.
The second piece is to separate trend from rhythm rather than choose between them. MOSAIC picks either a trend model or an oscillator model per gene by the Bayesian information criterion. We fit a low-order trend (the slow "envelope") plus the harmonic terms (the periodic "carrier") in one linear model, in the spirit of Dhiman's separation of vocal-tract envelope from glottal carrier. We do not adopt the Riesz transform itself, which needs dense spectrograms that 6 to 24 time points cannot provide.
The third piece is an evaluation vocabulary borrowed from pitch tracking. Speech work distinguishes gross errors, such as octave jumps, from fine errors. We score gross errors as a reported period or harmonic order that is wrong, for example calling a 12-hour rhythm 24-hour. Fine errors are phase error in hours among correct calls.
Research Program
The model has three layers of estimation.
The first is the pooled period estimate. The second is the per-gene linear fit of trend plus harmonics in each layer. The number of harmonics is limited by the sampling rate: 4-hour sampling allows harmonics down to 8 hours, and 6-hour sampling allows only the 24-hour term.
The third is a hierarchical prior tying each protein's coefficients to its RNA's coefficients through the filter above. Each gene gets its own $\gamma_g$ and $k_g$. These are drawn from population distributions fit by empirical Bayes across all genes, so information about typical half-lives is shared across genes rather than fixed by hand. Missing protein measurements are simply dropped from the likelihood.
Rhythmicity of each protein is tested by comparing two models: one with the harmonic terms and one with trend only. The null distribution comes from permuting time labels within each layer and replicate, which keeps each layer's noise structure intact. Empirical false discovery rates, not information-criterion thresholds, set the decision rule.
Filter consistency gets its own test. We compare the fitted filter model against a model with an unconstrained protein phase and amplitude, calibrated in the same way. This is what turns "rescued" versus "independent" into a statistical claim rather than a byproduct of model selection. Where independent protein half-life measurements exist for a subset of genes, the fitted $\gamma_g$ can be checked against them directly. We make no claim here about which datasets have such measurements.
Baselines
The naive reference point is to run the single-layer rhythm detectors MetaCycle, JTK_CYCLE and ECHO on the proteomics alone. MOSAIC showed their true positive rate and F1 collapse under high proteomic noise. Including them anchors the scale of the problem.
The strongest existing method is MOSAIC itself. The file reports that it rescues up to 45 oscillating proteins in the high-noise, low-resolution synthetic tiers and over 300 in Neurospora, with a slightly higher false discovery rate in the sparsest settings. No reported per-tier F1, true positive rate or false discovery rate numbers were found on Lacuna for MOSAIC's synthetic benchmark, so we will rerun it ourselves.
Because MOSAIC's known weakness is initialization, fairness requires a second version: MOSAIC with a dense multi-start grid over period and phase, given the same compute budget as our method. This version tells us whether our gains come from the model or merely from escaping local minima. All methods receive identical data, replicate structure and missingness patterns. They are all calibrated with the same permutation null, so every comparison is made at matched empirical false discovery rate.
Two ablations isolate the key ingredient. The first drops the cross-layer prior entirely: a fixed-period harmonic regression on protein alone, using our pooled period. The second keeps a cross-layer prior but lets the protein's lag and gain relative to RNA be drawn from an unconstrained empirical distribution, without the kinetic link between lag and damping.
We would count the method as beating MOSAIC if it shows higher true positive rate at matched empirical false discovery rate in the 6-hour and single-replicate tiers. Its empirical false discovery rate must also stay at or below nominal in those tiers where MOSAIC's rises. The kinetic constraint is justified only if the full model also beats the unconstrained-lag ablation.
Why not just…?
Why not just fix MOSAIC's initialization with a grid search? With so few time points a grid search is cheap, and it may remove most of MOSAIC's local-minimum failures. It does not address the second problem, which is that MOSAIC lets protein amplitude and phase vary freely. That freedom makes a noisy protein easy to fit spuriously and is a plausible source of its rising false discovery rate at sparse sampling. The multi-start baseline tests this directly. If it closes the gap to our model, the honest conclusion is that non-convexity was the whole story.
Why not just learn the RNA-to-protein lag empirically, without any kinetics? This is the real threat. A free-lag empirical Bayes prior captures most of what our model does, and the free-lag ablation is designed to settle it. The kinetic filter should win when proteins are noisy enough that their amplitude alone is uninformative. In that regime, the link between damping and lag is extra information that the free prior lacks. The filter also produces the filter-consistency test, which a free prior cannot. If the free-lag model matches on detection, we would present the filter mainly as a tool for classifying proteins as inherited or independent rather than as a power gain.
Why not just factorize the stacked matrices with MOFA? MOFA separates variation shared across layers from variation private to one layer, handles missing data well, and converged in 45 minutes on its leukemia cohort. It is, however, linear and treats time points as exchangeable, so shuffling the time order leaves its factors unchanged. It therefore cannot represent phase lag or the link between damping and lag. We will include a MOFA-factors-then-cosinor pipeline in the synthetic study as a secondary comparison. We expect it to find shared rhythmic factors but not to make calibrated calls for individual proteins.
Why not just train a neural network? With 6 to 24 time points per series, a network has far too little data to learn periodic structure without an explicit prior. SLASH needed a signal-processing prior even with 585 hours of speech. We do not plan a neural baseline.
Proposed Experiments
The first experiment uses MOSAIC's synthetic design: 2-, 4- and 6-hour sampling, 1 to 3 replicates, and three noise tiers. We will regenerate it with MOSAIC's own generator, whose protein dynamics are not built on our filter, so our model gets no home advantage. We will separately generate data from the kinetic filter with a planted fraction of independent protein rhythms, and use it to measure how well the filter-consistency test recovers them. Metrics are true positive rate, F1, and empirical versus nominal false discovery rate, together with the gross-period and fine-phase error rates defined above.
The second experiment uses the Neurospora crassa multi-omics series. Lacking ground truth, we build a pseudo-ground truth by downsampling. Calls made on the full-resolution data serve as reference. The data are then thinned to 6-hour spacing and to single replicates, and each method's calls are scored against that reference. We will also check whether the proteins our model flags as filter-inconsistent overlap the 18.5% that MOSAIC calls transcriptome-independent, and characterize where the two sets disagree.
The third experiment is a narrow check of the pooled period estimate on the transcriptome-only tissue datasets used by tauFisher. Under an entrained 24-hour cycle this should simply return 24 hours; failing to do so would expose bias in the pooled estimator. We do not claim to replace tauFisher's single-sample timing.
The decisive result would have three parts. The full model must beat multi-start MOSAIC on true positive rate at matched false discovery rate in the 6-hour, single-replicate tiers. It must keep its empirical false discovery rate calibrated there. It must beat the free-lag ablation in the high-noise tiers. If only the first two hold, the contribution narrows to calibrated convex testing, and we would report it as such.
References
- MOSAIC: A Joint Modeling Methodology for Combined Circadian and Non-Circadian Analysis of Multi-Omics Data
- SLASH: Self-Supervised Speech Pitch Estimation Leveraging DSP-derived Absolute Pitch
- A Spectro-Temporal Demodulation Technique for Pitch Estimation
- Model-based estimation of instantaneous pitch in noisy speech
- Multi‐Omics Factor Analysis—a framework for unsupervised integration of multi‐omics data sets
- tauFisher predicts circadian time from a single sample of bulk and single-cell pseudobulk transcriptomic data