A Paper Spectrum Ladder for Empiric Antibiotic Choice

Machine-learning models can already estimate, from a patient's record, how likely each antibiotic is to work before lab culture results come back. In one UK cohort, letting the model choose would have raised the share of patients on the narrowest drug that still works from 26% to 34% (Bannister et al.). The model does not prescribe, though. A clinician does, usually away from the screen, standing at the bedside with a drug chart in hand. This proposal asks how much of the model's benefit actually reaches the prescription, and whether a physical, paper-based way of presenting the prediction carries more of it through than a screen panel does. The artifact is a "spectrum ladder": a printed card that ranks the candidate drugs from narrowest to broadest and shows each drug's predicted chance of covering the infection. The clinician commits by physically marking a rung with a digital pen, and the card is reissued when the lab names the bacterial species.

The opportunity follows from two facts. First, under current practice clinicians' implied sensitivity for detecting piperacillin-tazobactam resistance was only 6% (Bannister et al.), so better information has room to change decisions. Second, every resistance predictor in the file is evaluated offline, as AUROC on a retrospective cohort, and none has been tested at the moment a person decides. Studies of embodied interaction, meaning interfaces built around physical objects and the user's body rather than menus on a screen, suggest that the form of that moment matters. The aim is a measured answer to whether it does here, designed so that a negative result is just as informative as a positive one.

Core Claim

The measurable quantity is the realized fraction: the share of the model's stand-alone improvement over unaided clinicians that survives once a clinician uses the model through a given interface. If $O_h$ is the rate of optimal treatment (narrowest active drug) by unaided clinicians, $O_m$ the rate under the model's own policy, and $O_{h+i}$ the rate for clinicians using interface $i$, then

$$R_i = \frac{O_{h+i} - O_h}{O_m - O_h}.$$

$R_i$ can exceed 1 if clinicians catch the model's errors, and it can fall below 0 if the interface misleads.

The claim has two parts. The first is that a layout pairing each drug with its spectrum rank and its predicted coverage, then requiring an explicit commitment to one rung, raises $R$ relative to a conventional list of probabilities. The second, which is separable and riskier, is that making that commitment on a physical card at the point of care raises $R$ further and improves calibrated reliance. Calibrated reliance means following the model when it is right and overriding it when it is wrong, which matters most when the model has drifted, as these models do over time and across hospitals (Wang et al.; Bannister et al.).

The research file finds no prior work combining tangible interfaces with antimicrobial decision support. The closest neighbors each lack one ingredient. CARAT built a clipboard-like stylus tablet that kept clinicians in eye contact with patients and cut data-entry lag from 232 days to 3 days. It was used for psychiatric data collection, not for decisions informed by predictions. The Stanford order recommender study measured how 43 physicians used a machine-learning recommender in simulated cases. Its interface was a browser screen, and it targeted generic orders, not the trade-off between spectrum and coverage. Bolton et al. argued that prescribing support should make the societal cost of broad-spectrum use visible, but they left the presentation unsolved and warned about alert fatigue. The ladder is a deliberately modest answer to that problem: it shows spectrum as an ordinal position instead of computing a moral score.

Research Program

Predictive layer. This part reuses existing methods. The project trains gradient-boosting and ensemble resistance models on the Philips eICU database, following Wang et al., who report ensemble AUC 0.8946 against 0.8601 for a naive antibiogram. It trains separately on MIMIC-IV, following the multimodal pipeline of Hardan et al.. Models are trained in two stages. Stage one uses only information available at blood draw. Stage two adds the species identification, which Bannister et al. found lifts AUC from 0.68–0.74 to about 0.83.

Natural model drift. Model failures are not invented. Training on eICU and predicting on MIMIC-IV cases produces realistic cross-hospital degradation. Each vignette is then tagged as model-right or model-wrong against the recorded susceptibility result.

Vignettes. Cases are drawn from MIMIC-IV episodes with a known culture and susceptibility outcome and rendered as short clinical summaries. The candidate drugs for each case are ordered on the ladder by spectrum. Regimens shown to be defensible are kept: Cariou et al. found no significant Day-30 mortality penalty for non-carbapenem β-lactams plus aminoglycosides in urinary septic shock caused by extended-spectrum β-lactamase-producing Enterobacterales (raw mortality 15% vs 7%, OR 1.99, p=0.16). That study is observational with 156 patients, so it justifies including the narrower rungs but not recommending them.

Physical artifact. This borrows techniques from paper computing. Like TinkerSheets, which used paper forms as both input and output for a simulation, and the MonAMI reminder, which synchronized digital-pen strokes on paper with a back-end calendar, the ladder card is printed with a dot pattern so that pen marks are captured digitally. A digital pen is chosen over a camera-and-projector rig because TinkerSheets reports occlusion and lighting failures that would not survive a ward.

Synchronization failure. The card is the part of the design most likely to go wrong. MonAMI documents that web-side changes never reach the printed page. The ladder faces the same problem at species identification, when the predictions change but the old card is still in the clinician's hand. Each card therefore carries a stage label and timestamp. Stale-card behavior is studied directly as an ablation, described below.

Baselines

The naive reference point is clinicians working alone with a printed institutional antibiogram, the table of the hospital's past susceptibility rates. It costs nothing, and it is the true status quo. In a retrospective setting, Bannister et al. report that clinicians achieved 70% active treatment and 26% optimal treatment, with 30% under-treatment. These figures anchor $O_h$, but the study re-measures them in its own participants on its own vignettes rather than importing them. On discrimination alone, the antibiogram model scores AUC 0.8601 on eICU (Wang et al.).

The strongest existing method is the model's own policy with no human involved, which sets $O_m$. Bannister et al. report that it raised active treatment to 79% and optimal treatment to 34%. The model is recomputed on the study's vignettes. Beating it outright is not required. The proposal succeeds if clinicians using the ladder reach $R$ close to or above 1 and override the model more often than chance when it is wrong under drift.

The strongest interface competitor is a conventional screen panel listing per-drug probabilities, the form implied by Hardan et al. and Bannister et al. and implemented as a browser tool in the Stanford recommender study. That study found equivalent appropriateness (−0.1, 95% CI [−0.4, 0.2]) and 95% physician acceptance. A default-order nudge is a second competitor: the model's top choice is pre-filled and the clinician must actively change it.

Two ablations isolate the key ingredients. A screen ladder, with exactly the same layout as the paper card but on a tablet, separates the effect of the layout from the effect of physicality. A stale-card condition, where the stage-one card is not reissued at species identification, measures the cost of failed synchronization. Fairness rules are fixed in advance. All arms see identical vignettes, predictions, and stage timing. The order of conditions is counterbalanced. Every interface gets the same pilot-tuning budget, two design iterations with five clinicians each.

Why not just…?

Why not just put the predictions in the EHR? The electronic health record is where hospitals would deploy this, so a screen panel is the most serious threat. The evidence against it in the file is indirect: reports of click fatigue and adherence of only 20–80% (Stanford study), and the modal-break argument from CARAT and TinkerSheets. None of these sources measured prescribing outcomes. The comparison of screen ladder against paper ladder settles the question directly. If the two tie, the conclusion is that the layout matters and the paper does not, and the recommendation becomes "ship the ladder in the EHR."

Why not just let the model's choice be the default order? Defaults may well capture most of the gain, which is why the nudge is a measured arm and not a strawman. The case for keeping a deliberate human commitment rests on drift. Both Wang et al. (AUC falling to about 0.87 on newer data) and Bannister et al. (failure to transfer across hospital systems) show that the model will sometimes be wrong. The cross-hospital vignettes test whether defaults cause clinicians to accept those errors more often than the ladder does. If the default matches the ladder on both $R$ and override-when-wrong, the default wins on cost.

Why not just print a better static antibiogram? A static card stratified by ward or by syndrome is cheap and has no synchronization problem. It cannot use individual patient history, however, and that history is the source of Wang et al.'s gain over the antibiogram. The naive arm, combined with the stale-card ablation, shows how much of the effect comes from updated, patient-specific numbers rather than from paper itself.

Proposed Experiments

Roughly 40 clinicians, comparable to the 43 in the Stanford study and well above the 14 in Zhu et al., each complete about 30 two-stage vignettes. Arms are crossed with vignettes in a counterbalanced within-subjects design. Primary outcomes are optimal-treatment rate, active-treatment rate, under-treatment rate, and $R$, all scored against recorded susceptibility. Secondary outcomes are override-when-wrong and follow-when-right rates on the drift vignettes, decision time, and post-species switching. The model layer is reported alongside: AUROC and AUPR, given Hardan et al.'s warning that AUPR can be as low as 0.1825 for gentamicin when resistant cases are rare.

There are three decisive checks. The first is whether the screen ladder raises $R$ over the probability list; this is a test of the layout. The second is whether the paper ladder beats the screen ladder on $R$ or on override-when-wrong; this is a test of embodiment. The third is whether the stale-card condition produces measurable harm after species identification; this is a test of whether synchronization is a real constraint. A cleanly measured result on the second check is the contribution in either direction, because the file contains no evidence yet for or against physical interfaces in prescribing. The study is a simulation, and success would justify a ward pilot, not a claim about patient outcomes.