To interface with the nervous or muscular systems with high spatial and temporal resolution, bioelectronic devices and clinical instruments must be placed in direct proximity to target tissues. However, this requirement creates a fundamental engineering paradox. High-fidelity signals traditionally demand invasive open surgeries—such as craniotomies for brain-machine interfaces or deep surgical dissections for intramuscular recording—which cause significant tissue trauma, scarring, and prolonged patient recovery. Conversely, non-invasive alternatives like surface electromyography (EMG) or scalp electroencephalography (EEG) suffer from severe signal attenuation and spatial blurring due to intervening tissue layers.
The emerging paradigm of minimally invasive tissue delivery resolves this tension by decoupling the mechanics of insertion from the mechanics of chronic integration. Instead of clearing massive physical pathways to expose a target site, researchers and clinicians utilize temporary rigid carriers (such as hypodermic needles and syringes), specialized tunneling instruments, or natural anatomical corridors (such as the transnasal sphenoid sinus) to deploy ultra-flexible, high-density interfaces. Once the interface is positioned, the rigid delivery vehicle is withdrawn or the natural cavity is leveraged to house the hardware, leaving behind a highly compliant, low-trauma device that seamlessly integrates with the host tissue.
Needle-Based Injection of Flexible Electronics
Ultra-thin, flexible polymer substrates are ideal for long-term tissue recording because their mechanical compliance matches that of biological tissue, minimizing chronic immune responses and mechanical shearing. However, their extreme flexibility makes them impossible to insert directly into dense tissue like muscle or brain matter without buckling.
To overcome this, a temporary rigid carrier can act as a mechanical guide during the insertion phase. In intramuscular EMG, Yoshida et al. demonstrated in Multichannel thin-film electrode for intramuscular electromyographic recordings that a fine hypodermic needle can serve as a temporary introducer for a multichannel thin-film electrode. Once the needle penetrates the target muscle, it is withdrawn, leaving the highly flexible substrate safely embedded within the tissue to sample motor unit activity with minimal trauma. Expanding on this approach, Muceli et al. developed an ultra-thin (20 $\mu$m) polyimide multichannel electrode in A thin-film multichannel electrode for muscle recording and stimulation in neuroprosthetics applications. Delivered via a standard hypodermic needle, this "all-in-one" interface achieves both high-fidelity recording and precise electrical stimulation for neuroprosthetic applications, remaining in place for acute testing after the needle is removed.
This injection strategy scales effectively to large-scale, high-density arrays. For instance, the "Myomatrix arrays" developed by Chung et al. in Myomatrix arrays for high-definition muscle recording are specifically designed to be loaded into standard hypodermic syringes. This injectable approach facilitates the deployment of high-definition muscle recording grids across various species and muscle groups where surgical access is challenging.
[ Loading ] Flexible Electrode Array ---> Inside Hypodermic Needle
|
[ Insertion ] Rigid Needle Penetrates Dense Tissue <--+
|
[ Withdrawal ] Needle Retracts ---> Flexible Array Remains Intact in Tissue
When targeting the central nervous system, where penetrating the protective meninges requires substantial force, specialized insertion mechanics become necessary to prevent flexible arrays from buckling. To address this, Tian et al. designed an implantation device featuring a micro-manipulator and a solenoid-driven rapid injection mechanism in An Ultraflexible Electrode Array for Large‐Scale Chronic Recording in the Nonhuman Primate Brain. By utilizing high-speed insertion, the device drives ultra-flexible electrode arrays through the tough meningeal layers of nonhuman primates with minimal tissue trauma, ensuring stable chronic recordings. A similar percutaneous philosophy applies to the spinal cord; Saitoh et al. demonstrated in Efficacy of spinal cord stimulation on post-stroke pain that a needle-based approach for percutaneous epidural lead placement allows multi-pole stimulation electrodes to be positioned in the spinal space, enabling parameter adjustment and therapeutic assessment without highly invasive open surgery.
Natural Cavities and Endoscopic Corridors
When the target tissue lies deep within the cranium, needle injection alone is insufficient, yet traditional open craniotomies present severe risks due to brain retraction and structural damage. The solution lies in exploiting natural anatomical gateways and utilizing high-definition endoscopic visualization to guide micro-invasive sensors and tools directly to the target site.
The sphenoid sinus serves as an ideal structural gateway for this purpose. As demonstrated by Zhang et al. in Optic chiasmatic potential by endoscopically implanted skull base microinvasive biosensor: a brain-machine interface approach for anterior visual pathway assessment, trans-sphenoidal endoscopic access allows a microinvasive biosensor to be implanted directly beneath the optic chiasm via the nasal cavity. This approach leverages the spacious, natural cavity of the sphenoid sinus to integrate extracranial hardware components, providing a safe environment for brain-machine interface hardware without encroaching on intracranial space or requiring an open-skull craniotomy. The resulting direct recording of the Optic Chiasmatic Potential (OCP) provides far superior signal strength and reliability compared to traditional scalp-recorded potentials.
Beyond sensor deployment, this endoscopic philosophy transforms deep surgical interventions by replacing blind maneuvers with direct sight. Feng et al. showed in Comparative analysis of outcomes following craniotomy and expanded endoscopic endonasal approach resection of tuberculum sellae meningiomas: a single-institution study that a transnasal endoscopic endonasal approach to skull base tumors provides a direct view of the tumor's ventral surface, completely avoiding the secondary injuries associated with brain retraction in traditional craniotomies. Similarly, Jiang et al. utilized an endoscopic transsphenoidal approach in Endoscopic transsphenoidal approach in resection of intracranial clivus chondrosarcoma: A case report to achieve gross total resection of deep skull base tumors, highlighting how high-definition endoscopic optics allow surgeons to navigate complex corridors and maintain clear margins while minimizing neurological complications.
Even when a small cranial opening is required, direct endoscopic visualization fundamentally changes the nature of the intervention. For example, Tohara et al. demonstrated in Clinical Efficacy of Endoscopic Surgery for Intracranial Abscesses that inserting a flexible neuroendoscope through a small burr hole allows surgeons to directly visualize, navigate, and physically disrupt internal septations within intracranial abscesses. This ensures thorough evacuation where blind catheter insertion would fail. This concept of direct visualization bypassing physical or structural obstructions is mirrored in other delicate spaces, such as the eye's drainage angle, where Liu et al. utilized direct endoscopic visualization in Outcomes of chronic angle-closure glaucoma treated by phacoemulsification and endocyclophotocoagulation with or without endoscopically goniosynechialysis to perform precise mechanical stripping of adhesions (goniosynechialysis) despite corneal cloudiness.
Subscalp Tunneling for Chronic Monitoring
The principle of minimizing structural disruption also applies to large-scale cortical monitoring. Traditional high-density EEG requires either cumbersome external scalp electrodes that suffer from motion artifacts and signal degradation, or highly invasive intracranial grids that require a craniotomy.
To bridge this gap, the authors of Feasibility, Safety, and Performance of Full-Head Subscalp EEG Using Minimally Invasive Electrode Implantation, with first author van Maren et al., validated a minimally invasive surgical technique for full-head subscalp EEG. Instead of exposing the cranium, the procedure uses small scalp incisions and specialized tunneling tools to slide flexible electrode leads beneath the scalp and over the skull.
| Interface Type | Invasiveness | Signal Quality | Spatial Coverage |
|---|---|---|---|
| Scalp EEG | Non-invasive | Low (attenuated by skull) | Full-head, prone to motion artifacts |
| Intracranial Grid | High (Craniotomy required) | High (Direct cortical contact) | Limited to surgical window |
| Subscalp Tunneling | Minimally Invasive (Small incisions) | High (Subscalp placement) | Full-head, stable chronic tracking |
This approach enables the safe, high-density deployment of long-term brain monitoring hardware across the entire head. By placing the flexible leads beneath the moving layers of the skin but outside the skull, it provides a stable, low-noise interface that remains completely unobtrusive to the patient for chronic applications.
Key Foundational Work
Multichannel thin-film electrode for intramuscular electromyographic recordings (2007) — contributed 1 concept elements to this direction.
A thin-film multichannel electrode for muscle recording and stimulation in neuroprosthetics applications (2019) — contributed 1 concept elements to this direction.
<b>Efficacy of spinal cord stimulation on post-stroke pain</b> (2007) — contributed 1 concept elements to this direction.