UK Biobank · Image Generation

83 papers · 264 extracted observations · phenotype prediction · Markdown · CSV · JSON API

Also indexed as: uk-biobank

Showing 7 of 7 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2024TUMSyn proposedPSNR29.81 dBImage Generation · modality=FLAIR · direction=coronalTowards General Text-guided Image Synthesis for Customized Multimodal Brain MRI Generation
Source quote
L108: Besides SynthSR, TUMSyn is also compared with ArSSR~\cite{wu2022arbitrary}, which is an SR model that can support arbitrary-scale upsampling and particularly trained on this dataset. Notably, across all the three simulated FLAIR images, TUMSyn achieves the best performance in terms of PSNR and SSIM. For example, compared to ArSSR, TUMSyn improves PSNR of images scanned in the coronal direction from 29.08 dB to 29.81 dB. Our method outperforms SynthSR by up to 23.2% (from 22.91 dB to 29.82 dB) in PSNR (Fig.\ref{fig:Fig.5} f).
2024ArSSR baselinePSNR29.08 dBImage Generation · modality=FLAIR · direction=coronalTowards General Text-guided Image Synthesis for Customized Multimodal Brain MRI Generation
Source quote
L108: Besides SynthSR, TUMSyn is also compared with ArSSR~\cite{wu2022arbitrary}, which is an SR model that can support arbitrary-scale upsampling and particularly trained on this dataset. Notably, across all the three simulated FLAIR images, TUMSyn achieves the best performance in terms of PSNR and SSIM. For example, compared to ArSSR, TUMSyn improves PSNR of images scanned in the coronal direction from 29.08 dB to 29.81 dB. Our method outperforms SynthSR by up to 23.2% (from 22.91 dB to 29.82 dB) in PSNR (Fig.\ref{fig:Fig.5} f).
2023Latent Diffusion Models proposedFID2.1986Image Generation · split: test · resolution=160×224Generative AI for Medical Imaging: extending the MONAI Framework
Source quote
L62: UK Biobank │ 2D Brain Slice MRI │ 160 × 224 │ 2.1986 │ 0.5368 │ 0.9876
2023FID non-standard sliceFID (↓)14.10Image Generation · split: test · subset=central 10% of images removed · modality=whole-body MRI · evaluation=FID between distinct halves of the consistent imagesMetrics to Quantify Global Consistency in Synthetic Medical Images
Source quote
L145: Dataset │ FID (\downarrow) │ Explicit (Ours, \downarrow) │ Implicit (Ours, \uparrow) Consistent │ 14.10 │ 0.09 ± 0.05 │ 0.59 ± 0.12
20213D-StyleGAN (2mm-fd64) proposed non-standard sliceFID-Sag106.9Image Generation · split: test · resolution=2mm · feature-dim=643D-StyleGAN: A Style-Based Generative Adversarial Network for Generative Modeling of Three-Dimensional Medical Images
Source quote
L131: 2mm-fd64 │ 4497 (898.53) │ 0.93 (0.12) │ 106.9 │ 71.3 │ 90.2
20213D-StyleGAN (2mm-fd64) proposed non-standard sliceFID-Ax71.3Image Generation · split: test · resolution=2mm · feature-dim=643D-StyleGAN: A Style-Based Generative Adversarial Network for Generative Modeling of Three-Dimensional Medical Images
Source quote
L131: 2mm-fd64 │ 4497 (898.53) │ 0.93 (0.12) │ 106.9 │ 71.3 │ 90.2
20213D-StyleGAN (2mm-fd96) proposed non-standard sliceFID-Cor88.5Image Generation · split: test · resolution=2mm · feature-dim=963D-StyleGAN: A Style-Based Generative Adversarial Network for Generative Modeling of Three-Dimensional Medical Images
Source quote
L132: 2mm-fd96 │ 4475 (539.38) │ 0.96 (0.04) │ 138.3 │ 83.2 │ 88.5