UK Biobank

83 papers · 264 extracted observations · phenotype prediction · Markdown · CSV · JSON API

Also indexed as: uk-biobank

Showing 94 of 94 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2026PiLA (proposed physiology-guided self-supervised framework) proposed non-standard sliceAUROC0.7645Aortic Stenosis Screening · split: test · fine-tuned · input=single-beat PPG · pretraining=over 170,000 unlabeled PPG samples · waveform-length=100 pointsAortic Valve Disease Screening from PPG via Physiology-Guided Self-Supervised Learning
Source quote
L109: PiLA (Ours) │ 0.7645 │ 0.7755 │ 0.7072
2026PiLA (proposed physiology-guided self-supervised framework) proposed non-standard sliceAUROC0.7756Aortic Regurgitation Screening · split: test · fine-tuned · input=single-beat PPG · pretraining=over 170,000 unlabeled PPG samples · waveform-length=100 pointsAortic Valve Disease Screening from PPG via Physiology-Guided Self-Supervised Learning
Source quote
L122: PiLA (Ours) │ 0.7756 │ 0.7857 │ 0.7490
2026ResNet1D (Baseline) baselineAUROC0.6985Aortic Stenosis Screening · split: test · supervised · input=single-beat PPG · training-data=limited labeled data · waveform-length=100 pointsAortic Valve Disease Screening from PPG via Physiology-Guided Self-Supervised Learning
Source quote
L100: ResNet1D (Baseline) │ 0.6985 │ 0.6531 │ 0.6613
2026ResNet1D (Baseline) baselineAUROC0.7013Aortic Regurgitation Screening · split: test · supervised · input=single-beat PPG · training-data=limited labeled data · waveform-length=100 pointsAortic Valve Disease Screening from PPG via Physiology-Guided Self-Supervised Learning
Source quote
L113: ResNet1D (Baseline) │ 0.7013 │ 0.7143 │ 0.6786
2025GNN+RV proposedF10.716Dementia Risk Prediction · split: test · cohort-size=9537 · representation=randomly initialized diagnosis vectors · prediction-horizon=5 yearsPredicting Dementia Risk Using Longitudinal Electronic Health Records Data
Source quote
L97: 0.716
2025GNN+RV proposedSensitivity0.761Dementia Risk Prediction · split: test · cohort-size=9537 · representation=randomly initialized diagnosis vectors · prediction-horizon=5 yearsPredicting Dementia Risk Using Longitudinal Electronic Health Records Data
Source quote
L98: 0.761
2025GNN+RV proposedSpecificity0.673Dementia Risk Prediction · split: test · cohort-size=9537 · representation=randomly initialized diagnosis vectors · prediction-horizon=5 yearsPredicting Dementia Risk Using Longitudinal Electronic Health Records Data
Source quote
L99: 0.673
2025GNN+RV proposedJ0.434Dementia Risk Prediction · split: test · cohort-size=9537 · representation=randomly initialized diagnosis vectors · prediction-horizon=5 yearsPredicting Dementia Risk Using Longitudinal Electronic Health Records Data
Source quote
L100: 0.434
2025GNN+RV proposedAUCROC0.777Dementia Risk Prediction · split: test · cohort-size=9537 · representation=randomly initialized diagnosis vectors · prediction-horizon=5 yearsPredicting Dementia Risk Using Longitudinal Electronic Health Records Data
Source quote
L101: 0.777
2025LoRA fine-tuned Mistral-7B-Instruct proposedAUROC0.738Clinical Risk Prediction · split: test · fine-tuned · params=7B · backbone=Mistral-7B-Instruct · fine-tuning=LoRA · prediction-horizon=10-yearFrom Structured Data to Clinical Notes: Robust Clinical Decision Support with Fine-Tuned LLMs
Source quote
L78: Figure 2 shows the performance using only the base risk factors as inputs. Both the LLM-based model and LGBM achieved state-of-the-art performance for CVD risk prediction, with an area under the receiver operating characteristic curve (AUROC) of 0.738.
2025SLSE (VAE-encoder spirogram embedding fused with demographic information; CatBoost classifier) proposed non-standard sliceAUROC0.7501Disease Detection · split: test · subset=selected cohortArtificial Intelligence-Enabled Spirometry for Early Detection of Right Heart Failure
Source quote
L137: We choose area under the receiver operating characteristic curve (AUROC) as the indicator to evaluate model performance. For our task, AUROC is suitable for evaluating the performance of the model in a dataset with an imbalance of positive and negative samples. As shown in the Table \ref{tab:Demographic}, the number of healthy people in the dataset is much higher than that of patients with RHF, which is also in line with the actual clinical situation. Our model finally achieved AUROC=0.7501 on the test set, which shows that the model has good performance in predicting patients with RHF.
2025SLSE (VAE-encoder spirogram embedding fused with demographic information; CatBoost classifier) proposed non-standard sliceAUROC0.8194Disease Detection · split: test · subset=CKDArtificial Intelligence-Enabled Spirometry for Early Detection of Right Heart Failure
Source quote
L142: Ultimately, we find that the model achieves better AUROC performance on VHD, CKD, CHD, diabetes, and smoking subsets than when tested on the entire test set (Figure \ref{fig:subgroup}a), particularly achieving an AUROC=0.8194 on the CKD subset, and an AUROC=0.8413 on the VHD subset. This demonstrates the potential of our model for predicting RHF in CKD and VHD patients. For a excellent AUROC performance on this two subsets, it is possibly because CKD and VHD will increase circulatory load, which significantly exacerbates the symptoms of RHF when combined with it. As for the differences in subgroup distribution, Figure \ref{fig:subgroup}c CKD group shows that the RHF prediction probability distribution for patients with CKD is significantly broader than that for those without CKD, and the median prediction probability is also larger; the same applies to VHD subgroup (Figure \ref{fig:subgroup}c VHD group). The p-values indicate that the model has strong classification ability for the CKD subgroup but weaker classification ability for the VHD subgroup, suggesting that further validation with more VHD patient samples may be needed.
2025SLSE (VAE-encoder spirogram embedding fused with demographic information; CatBoost classifier) proposed non-standard sliceAUROC0.8413Disease Detection · split: test · subset=VHDArtificial Intelligence-Enabled Spirometry for Early Detection of Right Heart Failure
Source quote
L142: Ultimately, we find that the model achieves better AUROC performance on VHD, CKD, CHD, diabetes, and smoking subsets than when tested on the entire test set (Figure \ref{fig:subgroup}a), particularly achieving an AUROC=0.8194 on the CKD subset, and an AUROC=0.8413 on the VHD subset. This demonstrates the potential of our model for predicting RHF in CKD and VHD patients. For a excellent AUROC performance on this two subsets, it is possibly because CKD and VHD will increase circulatory load, which significantly exacerbates the symptoms of RHF when combined with it. As for the differences in subgroup distribution, Figure \ref{fig:subgroup}c CKD group shows that the RHF prediction probability distribution for patients with CKD is significantly broader than that for those without CKD, and the median prediction probability is also larger; the same applies to VHD subgroup (Figure \ref{fig:subgroup}c VHD group). The p-values indicate that the model has strong classification ability for the CKD subgroup but weaker classification ability for the VHD subgroup, suggesting that further validation with more VHD patient samples may be needed.
2025GNN+MLP+RV ablationJ0.428Dementia Risk Prediction · split: test · cohort-size=9537 · representation=randomly initialized diagnosis vectors · prediction-horizon=5 yearsPredicting Dementia Risk Using Longitudinal Electronic Health Records Data
Source quote
L94: 0.428
2025Gradient-boosted trees baselineAUROC0.738Risk Prediction · split: test · input=structured-tabular · risk-setting=base-risk-factor · prediction-horizon=10-yearAdaptable Cardiovascular Disease Risk Prediction from Heterogeneous Data using Large Language Models
Source quote
L97: Its performance matched the performance of gradient-boosted trees (AUROC: 0.738), which are specifically designed for and known to excel with this setting of structured tabular inputs.
2025LGBM baselineAUROC0.738Clinical Risk Prediction · split: test · model=LGBM · prediction-horizon=10-yearFrom Structured Data to Clinical Notes: Robust Clinical Decision Support with Fine-Tuned LLMs
Source quote
L78: Figure 2 shows the performance using only the base risk factors as inputs. Both the LLM-based model and LGBM achieved state-of-the-art performance for CVD risk prediction, with an area under the receiver operating characteristic curve (AUROC) of 0.738.
2024PSPS proposedSignificant genetic variants108 variantsVqtl Discovery · split: test · fdr=<0.05 · trait=total-body DXA-BMD · labeled-samples=36971 · unlabeled-samples=319548Task-Agnostic Machine-Learning-Assisted Inference
Source quote
L348: No genetic variants reached statistical significance under the classical method with only labeled data. \PSPS~identified 108 significant variants with FDR \(< 0.05\) spanning 5 independent loci, showcasing the superior statistical power of \PSPS~(\cref{fig:vqtl.man} and \cref{table:vQTL}). Notably, these significant vQTL cannot be identified by linear regression \citep{miao2024valid}, indicating the different genetic mechanisms controlling outcome levels and variability for DXA-BMD.
2024PSPS proposedIndependent loci spanning significant vQTLs5 lociVqtl Discovery · split: test · fdr=<0.05 · trait=total-body DXA-BMD · labeled-samples=36971 · unlabeled-samples=319548Task-Agnostic Machine-Learning-Assisted Inference
Source quote
L348: No genetic variants reached statistical significance under the classical method with only labeled data. \PSPS~identified 108 significant variants with FDR \(< 0.05\) spanning 5 independent loci, showcasing the superior statistical power of \PSPS~(\cref{fig:vqtl.man} and \cref{table:vQTL}). Notably, these significant vQTL cannot be identified by linear regression \citep{miao2024valid}, indicating the different genetic mechanisms controlling outcome levels and variability for DXA-BMD.
2024Med-Gemini-Polygenic proposed non-standard sliceAUC82.5Disease Risk Prediction · split: test · subset=balanced: 200 cases and 200 controlsAdvancing Multimodal Medical Capabilities of Gemini
Source quote
L1154: Coronary artery disease │ AUC │ 82.5 │ N/A │ 78.5 │ \multirow{14}{*}{\begin{tabular}[c]{@{}c@{}}Ensemble of PRSs and Demographics}
2024KRR-FP16 proposed non-standard slicePearson correlation0.8652Phenotype Prediction · split: test · phenotype=Allergic Rhinitis · precision=FP16Toward Capturing Genetic Epistasis From Multivariate Genome-Wide Association Studies Using Mixed-Precision Kernel Ridge Regression
Source quote
L406: \texttt{Allergic Rhinitis} │ 0.2008 │ 0.8652 │ N/A
2024KRR-FP16 proposed non-standard slicePearson correlation0.8071Phenotype Prediction · split: test · phenotype=Hypertension · precision=FP16Toward Capturing Genetic Epistasis From Multivariate Genome-Wide Association Studies Using Mixed-Precision Kernel Ridge Regression
Source quote
L403: \texttt{Hypertension} │ 0.2983 │ 0.8071 │ N/A
2024IdenBAT proposed non-standard slicePAD (↓), All3.52Brain Age Transformation · split: test · slice=97th axial · subset=longitudinal pairs; age gap >2 years · target-ages=48–80 · input-dimension=2DIdenBAT: Disentangled representation learning for identity-preserved brain age transformation
Source quote
L217: IdenBAT (Ours) │ 26.314 │ 0.924 │ 0.0026 │ 3.52 │ 3.27 │ 3.05 │ 3.56 │ 3.14 │ 4.72
2024IdenBAT proposed non-standard slicePAD (↓), All4.68Brain Age Transformation · split: test · subset=longitudinal pairs; age gap >2 years · target-ages=48–80 · input-dimension=3DIdenBAT: Disentangled representation learning for identity-preserved brain age transformation
Source quote
L219: IdenBAT (Ours) │ 29.653 │ 0.958 │ 0.0020 │ 4.68 │ 5.24 │ 3.47 │ 4.26 │ 5.27 │ 5.35
2024IdenBAT proposed non-standard sliceSSIM (↑)0.958Brain Age Transformation · split: test · subset=longitudinal pairs; age gap >2 years · input-dimension=3DIdenBAT: Disentangled representation learning for identity-preserved brain age transformation
Source quote
L219: IdenBAT (Ours) │ 29.653 │ 0.958 │ 0.0020 │ 4.68 │ 5.24 │ 3.47 │ 4.26 │ 5.27 │ 5.35
2024Net1D + Dist Loss (paper's “Ours”) proposedPearson correlation coefficient0.474Vascular Age Estimation · split: test · held-out-fraction=40%Deep Imbalanced Regression to Estimate Vascular Age from PPG Data: a Novel Digital Biomarker for Cardiovascular Health
Source quote
L154: + Ours │ \textbf{\textcolor{red}{0.474}}
2024Net1D + Dist Loss (paper's “Ours”) proposed non-standard sliceMAE9.495Vascular Age Estimation · split: test · few-shot · subset=labels with occurrence probability below one-third of the maximumDeep Imbalanced Regression to Estimate Vascular Age from PPG Data: a Novel Digital Biomarker for Cardiovascular Health
Source quote
L171: + Ours │ \textbf{\textcolor{red}{0.686}} │ \textbf{\textcolor{red}{9.495}} │ \textbf{\textcolor{red}{12.029}} │ \textbf{\textcolor{red}{0.158}} │ \textbf{\textcolor{red}{4.963}} │ 6.851 │ \textbf{\textcolor{red}{59.846}} │ \textbf{\textcolor{red}{75.815}}
2024BrainLM proposedR20.464Masked Patch Prediction · split: testBrainLM: A foundation model for brain activity recordings
Source quote
L70: On the UKB test data, BrainLM achieved an average R2 score of 0.464 on the prediction of masked patches, indicating strong generalization on unseen recordings from the same distribution. Critically, BrainLM also generalized well to the HCP dataset, achieving a R2 score of 0.278. Despite differences in cohort and acquisition details, BrainLM could effectively model brain dynamics in this entirely new distribution. Figure 3 shows sample reconstructions on both UKB and HCP recordings. We found that the model generalization scales with data size and model size, showing strong model scaling (see Figure 4). Overall, these results demonstrate BrainLM’s ability to learn robust representations of fMRI recordings that generalize across datasets. This highlights the advantages of large-scale pretraining for learning widely applicable models of brain activity.
2024X-Diffusion (1-slice input) proposedTest 3D PSNR22.423D Reconstruction · split: test · input-slices=1X-Diffusion: Generating Detailed 3D MRI Volumes From a Single Image Using Cross-Sectional Diffusion Models
Source quote
L131: X-Diffusion (ours) │ 23.10 │ 22.42 │ 25.20 │ 23.04 │ 29.43 │ 25.26 │ 31.25 │ 26.85 │ 33.27 │ 27.44 │ 35.48 │ 29.01
2024Ensemble of PRSs and demographics baseline non-standard sliceAUC78.5Disease Risk Prediction · split: test · model=linear model using PRSs and demographics · subset=balanced: 200 cases and 200 controlsAdvancing Multimodal Medical Capabilities of Gemini
Source quote
L1154: Coronary artery disease │ AUC │ 82.5 │ N/A │ 78.5 │ \multirow{14}{*}{\begin{tabular}[c]{@{}c@{}}Ensemble of PRSs and Demographics}
2024RR-FP16 baseline non-standard slicePearson correlation0.2008Phenotype Prediction · split: test · phenotype=Allergic Rhinitis · precision=FP16Toward Capturing Genetic Epistasis From Multivariate Genome-Wide Association Studies Using Mixed-Precision Kernel Ridge Regression
Source quote
L406: \texttt{Allergic Rhinitis} │ 0.2008 │ 0.8652 │ N/A
2024RR-FP16 baseline non-standard slicePearson correlation0.2983Phenotype Prediction · split: test · phenotype=Hypertension · precision=FP16Toward Capturing Genetic Epistasis From Multivariate Genome-Wide Association Studies Using Mixed-Precision Kernel Ridge Regression
Source quote
L403: \texttt{Hypertension} │ 0.2983 │ 0.8071 │ N/A
2024LSAB baseline non-standard slicePAD (↓), All5.39Brain Age Transformation · split: test · slice=97th axial · subset=longitudinal pairs; age gap >2 years · target-ages=48–80 · input-dimension=2DIdenBAT: Disentangled representation learning for identity-preserved brain age transformation
Source quote
L215: \text{2D} │ LSAB~\cite{xia2021learning} │ 26.186 │ 0.604 │ 0.0092 │ 5.39 │ 4.30 │ 4.00 │ 5.02 │ 5.05 │ 6.73
2024CounterSynth baseline non-standard slicePAD (↓), All9.06Brain Age Transformation · split: test · subset=longitudinal pairs; age gap >2 years · target-ages=48–80 · input-dimension=3DIdenBAT: Disentangled representation learning for identity-preserved brain age transformation
Source quote
L218: \multirow{2}{*}{\text{3D}} │ CounterSynth~\cite{pombo2023equitable} │ 22.879 │ 0.771 │ 0.0062 │ 9.06 │ 13.15 │ 7.45 │ 4.77 │ 7.28 │ 12.96
2024CounterSynth baseline non-standard sliceSSIM (↑)0.771Brain Age Transformation · split: test · subset=longitudinal pairs; age gap >2 years · input-dimension=3DIdenBAT: Disentangled representation learning for identity-preserved brain age transformation
Source quote
L218: \multirow{2}{*}{\text{3D}} │ CounterSynth~\cite{pombo2023equitable} │ 22.879 │ 0.771 │ 0.0062 │ 9.06 │ 13.15 │ 7.45 │ 4.77 │ 7.28 │ 12.96
2024Plain Net1D baselinePearson correlation coefficient0.475Vascular Age Estimation · split: test · held-out-fraction=40%Deep Imbalanced Regression to Estimate Vascular Age from PPG Data: a Novel Digital Biomarker for Cardiovascular Health
Source quote
L148: Plain │ \textbf{\textcolor{red}{0.475}}
2024Plain Net1D baseline non-standard sliceMAE12.820Vascular Age Estimation · split: test · few-shot · subset=labels with occurrence probability below one-third of the maximumDeep Imbalanced Regression to Estimate Vascular Age from PPG Data: a Novel Digital Biomarker for Cardiovascular Health
Source quote
L165: Plain │ 0.637 │ 12.820 │ 13.786 │ 0.015 │ 6.522 │ 7.524 │ 865.377 │ 930.543
2024TPDM (1-slice input) baselineTest 3D PSNR9.293D Reconstruction · split: test · input-slices=1X-Diffusion: Generating Detailed 3D MRI Volumes From a Single Image Using Cross-Sectional Diffusion Models
Source quote
L130: TPDM \cite{TPDM} │ 10.48 │ 9.29 │ 10.86 │ 9.99 │ 11.33 │ 11.09 │ 14.13 │ 12.62 │ 16.65 │ 15.88 │ 31.48 │ 21.70
2023DisPred proposedAUC0.6692Disease Risk Prediction · split: test · phenotype=Alzheimer's disease family-history proxy · population=admixedImproving genetic risk prediction across diverse population by disentangling ancestry representations
Source quote
L91: South Asians (SAS), East Asians (EAS), Americans (AMR), Africans (AFR), and Europeans (EUR), and an admixed group composed of individuals not passing cut-off in any ancestry. Since UKB primarily comprises European participants, we set the threshold low to obtain enough admixed and non-EUR participants for our analysis. In both datasets, EUR ancestry individuals correspond to the largest proportion (48% for the ADSP and 92% for the UKB). Admixed individuals are the second largest group (44% for the ADSP and 6% for the UKB). For both cohorts, we consider four test datasets: i) all test participants, ii) European participants, iii) admixed participants, and iv) non-European participants, primarily AFR for the ADSP and primarily SAS for the UKB. Panel B presents the result for all the test participants, and the proposed DisPred leads to the best result for ADSP and the joint best result for UKB (Lasso-EUR being marginally better than DisPred). The analysis restricted to European participants is shown in panel C. In this case, Lasso-EUR achieves the best result, and the proposed method produces the second-best result for both datasets. In admixed individuals, DisPred produces the best result for both UKB and ADSP (Panel D). In UKB, the performance on admixed individuals (best AUC: 0.6692 by DisPred) is equivalent to the one
2023proposed pairwise pseudolikelihood proposed non-standard slicenumber of SNPs significantly associated with increased UBC risk11 SNPsRisk Association Analysis · split: test · subset=31 previously associated SNPs · disease=urinary bladder cancer · significance-threshold=BH-adjusted p < 0.05Unlocking Retrospective Prevalent Information in EHRs -- a Pairwise Pseudolikelihood Approach
Source quote
L30: Employing a Cox model \citep{cox1972regression}, we observe higher statistical power with the proposed approach compared to the standard partial-likelihood (PL) estimator, adjusted for left truncation and excluding prevalent observations. Of 31 tested SNPs, 11 were significantly associated with increased UBC risk using the proposed approach, compared to six SNPs detected by the standard PL estimator. The Benjamini-Hochberg (BH) \citep{benjamini1995controlling} procedure for multiple-testing was used, with significance threshold set at 0.05.
2023Genetic InfoMax (GIM) proposedEstimated MI1.3681Mutual Information Estimation · split: test · estimator=JSE · representation=first 10 principal componentsGenetic InfoMax: Exploring Mutual Information Maximization in High-Dimensional Imaging Genetics Studies
Source quote
L186: 40 │ 15 │ 1.3681 │ 0.3723~\textpm~0.0305
2023Latent Diffusion Models proposedFID2.1986Image Generation · split: test · resolution=160×224Generative AI for Medical Imaging: extending the MONAI Framework
Source quote
L62: UK Biobank │ 2D Brain Slice MRI │ 160 × 224 │ 2.1986 │ 0.5368 │ 0.9876
2023Bernoulli-sigmoid model with uniform unobservables (α=1) and prevalence constraint p(Y=1)=0.02 proposedAUC0.63Risk Prediction · split: test · alpha=1 · outcome=breast cancer · population=tested (T=1) · prevalence-constraint=p(Y=1)=0.02Domain constraints improve risk prediction when outcome data is missing
Source quote
L415: We also consider a baseline model which treats the untested group as negative; this is equivalent to predicting p(T_i=1, Y_i=1|X_i), an approach used in prior selective labels work \citep{shen2021artificial, ko2020detection, rastogi2023learn}. We find that, though this baseline no longer learns an implausible age trend, it underperforms our model in terms of AUC (AUC is 0.60 on the tested population vs. 0.63 for our model; AUC is 0.60 on the untested population vs. 0.63 for our model) and quintile ratio (quintile ratio on the tested population is 2.4 vs. 3.3 for our model; quintile ratio for both models is 2.5 on the untested population). This baseline is a special case of our model with the prevalence constraint set to p(Y=1|T=0) = 0, an implausibly low prevalence constraint. In light of this, it makes sense that this baseline learns a more plausible age trend, but underperforms our model overall.
2023Bernoulli-sigmoid model with uniform unobservables (α=1) and prevalence constraint p(Y=1)=0.02 proposedAUC0.63Risk Prediction · split: test · alpha=1 · outcome=breast cancer · population=untested (T=0) · prevalence-constraint=p(Y=1)=0.02Domain constraints improve risk prediction when outcome data is missing
Source quote
L415: We also consider a baseline model which treats the untested group as negative; this is equivalent to predicting p(T_i=1, Y_i=1|X_i), an approach used in prior selective labels work \citep{shen2021artificial, ko2020detection, rastogi2023learn}. We find that, though this baseline no longer learns an implausible age trend, it underperforms our model in terms of AUC (AUC is 0.60 on the tested population vs. 0.63 for our model; AUC is 0.60 on the untested population vs. 0.63 for our model) and quintile ratio (quintile ratio on the tested population is 2.4 vs. 3.3 for our model; quintile ratio for both models is 2.5 on the untested population). This baseline is a special case of our model with the prevalence constraint set to p(Y=1|T=0) = 0, an implausibly low prevalence constraint. In light of this, it makes sense that this baseline learns a more plausible age trend, but underperforms our model overall.
2023Bernoulli-sigmoid model with uniform unobservables (α=1) and prevalence constraint p(Y=1)=0.02 proposed non-standard slicequintile ratio3.3Risk Prediction · split: test · alpha=1 · outcome=breast cancer · population=tested (T=1) · prevalence-constraint=p(Y=1)=0.02Domain constraints improve risk prediction when outcome data is missing
Source quote
L415: We also consider a baseline model which treats the untested group as negative; this is equivalent to predicting p(T_i=1, Y_i=1|X_i), an approach used in prior selective labels work \citep{shen2021artificial, ko2020detection, rastogi2023learn}. We find that, though this baseline no longer learns an implausible age trend, it underperforms our model in terms of AUC (AUC is 0.60 on the tested population vs. 0.63 for our model; AUC is 0.60 on the untested population vs. 0.63 for our model) and quintile ratio (quintile ratio on the tested population is 2.4 vs. 3.3 for our model; quintile ratio for both models is 2.5 on the untested population). This baseline is a special case of our model with the prevalence constraint set to p(Y=1|T=0) = 0, an implausibly low prevalence constraint. In light of this, it makes sense that this baseline learns a more plausible age trend, but underperforms our model overall.
2023FID non-standard sliceFID (↓)14.10Image Generation · split: test · subset=central 10% of images removed · modality=whole-body MRI · evaluation=FID between distinct halves of the consistent imagesMetrics to Quantify Global Consistency in Synthetic Medical Images
Source quote
L145: Dataset │ FID (\downarrow) │ Explicit (Ours, \downarrow) │ Implicit (Ours, \uparrow) Consistent │ 14.10 │ 0.09 ± 0.05 │ 0.59 ± 0.12
2023Lasso-EUR baselineAUC0.6695Disease Risk Prediction · split: test · phenotype=Alzheimer's disease family-history proxy · population=EuropeanImproving genetic risk prediction across diverse population by disentangling ancestry representations
Source quote
L93: obtained in the EUR individuals (best AUC: 0.6695 by Lasso-EUR), but for the ADSP, the predictive ability is better in EUR (best AUC: 0.6532 by Lasso-EUR) compared to admixed individuals (best
2023model treating the untested group as negative baselineAUC0.60Risk Prediction · split: test · outcome=breast cancer · population=tested (T=1)Domain constraints improve risk prediction when outcome data is missing
Source quote
L415: We also consider a baseline model which treats the untested group as negative; this is equivalent to predicting p(T_i=1, Y_i=1|X_i), an approach used in prior selective labels work \citep{shen2021artificial, ko2020detection, rastogi2023learn}. We find that, though this baseline no longer learns an implausible age trend, it underperforms our model in terms of AUC (AUC is 0.60 on the tested population vs. 0.63 for our model; AUC is 0.60 on the untested population vs. 0.63 for our model) and quintile ratio (quintile ratio on the tested population is 2.4 vs. 3.3 for our model; quintile ratio for both models is 2.5 on the untested population). This baseline is a special case of our model with the prevalence constraint set to p(Y=1|T=0) = 0, an implausibly low prevalence constraint. In light of this, it makes sense that this baseline learns a more plausible age trend, but underperforms our model overall.
2023model treating the untested group as negative baselineAUC0.60Risk Prediction · split: test · outcome=breast cancer · population=untested (T=0)Domain constraints improve risk prediction when outcome data is missing
Source quote
L415: We also consider a baseline model which treats the untested group as negative; this is equivalent to predicting p(T_i=1, Y_i=1|X_i), an approach used in prior selective labels work \citep{shen2021artificial, ko2020detection, rastogi2023learn}. We find that, though this baseline no longer learns an implausible age trend, it underperforms our model in terms of AUC (AUC is 0.60 on the tested population vs. 0.63 for our model; AUC is 0.60 on the untested population vs. 0.63 for our model) and quintile ratio (quintile ratio on the tested population is 2.4 vs. 3.3 for our model; quintile ratio for both models is 2.5 on the untested population). This baseline is a special case of our model with the prevalence constraint set to p(Y=1|T=0) = 0, an implausibly low prevalence constraint. In light of this, it makes sense that this baseline learns a more plausible age trend, but underperforms our model overall.
2023model treating the untested group as negative baseline non-standard slicequintile ratio2.4Risk Prediction · split: test · outcome=breast cancer · population=tested (T=1)Domain constraints improve risk prediction when outcome data is missing
Source quote
L415: We also consider a baseline model which treats the untested group as negative; this is equivalent to predicting p(T_i=1, Y_i=1|X_i), an approach used in prior selective labels work \citep{shen2021artificial, ko2020detection, rastogi2023learn}. We find that, though this baseline no longer learns an implausible age trend, it underperforms our model in terms of AUC (AUC is 0.60 on the tested population vs. 0.63 for our model; AUC is 0.60 on the untested population vs. 0.63 for our model) and quintile ratio (quintile ratio on the tested population is 2.4 vs. 3.3 for our model; quintile ratio for both models is 2.5 on the untested population). This baseline is a special case of our model with the prevalence constraint set to p(Y=1|T=0) = 0, an implausibly low prevalence constraint. In light of this, it makes sense that this baseline learns a more plausible age trend, but underperforms our model overall.
2022Proposed conditional generative model proposedKL divergence0.0248Synthetic Data Generation · split: test · age-conditioned · clinical-measure=LVMGenerative Modelling of the Ageing Heart with Cross-Sectional Imaging and Clinical Data
Source quote
L135: 0.0248
2022Proposed conditional generative model proposedWasserstein distance15.2829Synthetic Data Generation · split: test · age-conditioned · clinical-measure=LVMGenerative Modelling of the Ageing Heart with Cross-Sectional Imaging and Clinical Data
Source quote
L136: 15.2829
2022Proposed conditional generative model proposedKL divergence0.0334Synthetic Data Generation · split: test · age-conditioned · clinical-measure=LVEDVGenerative Modelling of the Ageing Heart with Cross-Sectional Imaging and Clinical Data
Source quote
L137: 0.0334
2022Causal Shape Model, f_X(z_X^i,u_X;\cdot) proposedMedian VED0.8900 mm3D Shape Reconstruction · split: test · latent-dimension=16Deep Structural Causal Shape Models
Source quote
L380: 16 │ 0.9006 ± 0.10 │ 0.8900 │ 2.0421
2022Causal Shape Model, f_X(z_X^i,u_X;\cdot) proposedChamfer Distance2.0421 mm3D Shape Reconstruction · split: test · latent-dimension=16Deep Structural Causal Shape Models
Source quote
L380: 16 │ 0.9006 ± 0.10 │ 0.8900 │ 2.0421
2022DART (Deep Approximation of Retinal Traits) proposedPearson r0.9572Fractal Dimension Estimation · split: test · degradation=noneRobust and efficient computation of retinal fractal dimension through deep approximation
Source quote
L83: None │ 0.9160 │ 0.9572 (0.0000) │ 0.9561 (0.0000) │ y=0.01 + 1.00x
2022DART (Deep Approximation of Retinal Traits) proposedPearson r0.8817Fractal Dimension Estimation · split: test · degradation=severity-5Robust and efficient computation of retinal fractal dimension through deep approximation
Source quote
L88: Severity 5 │ 0.7773 │ 0.8817 (0.0000) │ 0.8840 (0.0000) │ y=0.02 + 0.99x
2022DistGP-Seg proposedDICE WM0.867Brain Tissue Segmentation · split: test · input=FLAIR · cohort=normal subjects · architecture=three-hidden-layerDistributional Gaussian Processes Layers for Out-of-Distribution Detection
Source quote
L841: DistGP-Seg (ours) │ 3 │ 0.829 │ 0.823 │ 0.867
2022Lifespan baselineKL divergence0.0253Synthetic Data Generation · split: test · age-conditioned · clinical-measure=LVMGenerative Modelling of the Ageing Heart with Cross-Sectional Imaging and Clinical Data
Source quote
L133: Lifespan \cite{or2020lifespan} │ 0.0253 │ 18.4733 │ 0.0349 │ 15.8506 │ 0.0703 │ 9.8091 │ 0.0322 │ 20.0034 │ 0.0442 │ 12.1956
2022Lifespan baselineWasserstein distance18.4733Synthetic Data Generation · split: test · age-conditioned · clinical-measure=LVMGenerative Modelling of the Ageing Heart with Cross-Sectional Imaging and Clinical Data
Source quote
L133: Lifespan \cite{or2020lifespan} │ 0.0253 │ 18.4733 │ 0.0349 │ 15.8506 │ 0.0703 │ 9.8091 │ 0.0322 │ 20.0034 │ 0.0442 │ 12.1956
2022Lifespan baselineKL divergence0.0349Synthetic Data Generation · split: test · age-conditioned · clinical-measure=LVEDVGenerative Modelling of the Ageing Heart with Cross-Sectional Imaging and Clinical Data
Source quote
L133: Lifespan \cite{or2020lifespan} │ 0.0253 │ 18.4733 │ 0.0349 │ 15.8506 │ 0.0703 │ 9.8091 │ 0.0322 │ 20.0034 │ 0.0442 │ 12.1956
2022PCA baselineMedian VED0.3862 mm3D Shape Reconstruction · split: test · latent-dimension=16Deep Structural Causal Shape Models
Source quote
L376: 16 │ 0.3951 ± 0.08 │ 0.3862 │ 0.4252
2022PCA baselineChamfer Distance0.4252 mm3D Shape Reconstruction · split: test · latent-dimension=16Deep Structural Causal Shape Models
Source quote
L376: 16 │ 0.3951 ± 0.08 │ 0.3862 │ 0.4252
2022BB-BLESS baseline non-standard sliceDetected effect locations8,385 voxelsLesion Effect Detection · split: test · subset=white-matter lesions · threshold=5% significance · sample-size=2000Bayesian Lesion Estimation with a Structured Spike-and-Slab Prior
Source quote
L380: For inference, we threshold the test statistics of BB-BLESS at a significance level of 5%. In contrast, for BLESS-VI we threshold the posterior probability of inclusion at 0.5 in order to acquire its respective binary significance map. Hence, we exploit variable selection as a means to conduct inference. On the other hand, the mass-univariate approach Firth regression ignores any form of spatial dependence and hence requires the application of a multiple testing correction where we adjust the p-values with a FDR correction \citep{benjamini1995} at a significance level of 5%. The results in Figure \ref{fig: ukbb_bless_firth} indicate a slightly larger extent of spatial activation for BB-BLESS and BLESS-VI compared to Firth regression for a sample size of N=2,000. For the covariate age, in the regression model estimated via Firth regression 10,171 voxels are deemed active based on uncorrected p-values. On the other hand, only 6,278 voxels pass the FDR adjusted threshold whereas in BB-BLESS 8,385 effect locations are detected by utilizing the full posterior to derive test statistics and similarly in BLESS-VI 8,257 effects are detected via simply thresholding the posterior inclusion probabilities.
2022U-Net baselineDICE WM0.86Brain Tissue Segmentation · split: test · input=FLAIR · cohort=normal subjects · architecture=three-scale U-NetDistributional Gaussian Processes Layers for Out-of-Distribution Detection
Source quote
L842: U-Net │ 3 scales │ 0.85 │ 0.89 │ 0.86
2021VR-Net (R-L2-6×1) proposed non-standard sliceDice (LV)0.948Image Registration · split: test · slices=basal, mid-ventricular, apical · subset=100 test subjects · structure=LVLearning a Model-Driven Variational Network for Deformable Image Registration
Source quote
L326: In Table \ref{tab:ukbb} and \ref{tab:acdc}, we show the quantitative results obtained by using different methods on UK Biobank and ACDC. In the tables, one can see that VR-Net outperforms iterative methods and data-driven methods on both datasets for almost all anatomical structures. On UK Biobank, RC-Net achieves the best result on RV in terms of both Dice and HD of 0.005 and 0.42mm respectively compared to that obtained by our best configuration of (R-\rm{L}_2-6×1). However, in terms of Dice, VR-Net achieves 0.948 on LV and 0.764 on Myo, outperforming 3×RC-Net by 0.004 and by 0.028, respectively. In terms of HD for LV and Myo, our VR-Net improves 3×RC-Net from 4.28mm to 3.90mm and from 7.39mm to 6.49mm, respectively. On average, the proposed VR-Net achieves a better Dice and HD score than 3×RC-Net, making our VR-Net the best method on this dataset.
20213D-StyleGAN (2mm-fd64) proposed non-standard sliceFID-Sag106.9Image Generation · split: test · resolution=2mm · feature-dim=643D-StyleGAN: A Style-Based Generative Adversarial Network for Generative Modeling of Three-Dimensional Medical Images
Source quote
L131: 2mm-fd64 │ 4497 (898.53) │ 0.93 (0.12) │ 106.9 │ 71.3 │ 90.2
20213D-StyleGAN (2mm-fd64) proposed non-standard sliceFID-Ax71.3Image Generation · split: test · resolution=2mm · feature-dim=643D-StyleGAN: A Style-Based Generative Adversarial Network for Generative Modeling of Three-Dimensional Medical Images
Source quote
L131: 2mm-fd64 │ 4497 (898.53) │ 0.93 (0.12) │ 106.9 │ 71.3 │ 90.2
20213D-StyleGAN (2mm-fd96) proposed non-standard sliceFID-Cor88.5Image Generation · split: test · resolution=2mm · feature-dim=963D-StyleGAN: A Style-Based Generative Adversarial Network for Generative Modeling of Three-Dimensional Medical Images
Source quote
L132: 2mm-fd96 │ 4475 (539.38) │ 0.96 (0.04) │ 138.3 │ 83.2 │ 88.5
2021DistGP-Seg proposed non-standard sliceDice (CSF)0.829Brain Tissue Segmentation · split: test · subset=healthy subjects, bottom 10th percentile for white-matter hypointensities · modality=FLAIR · split-protocol=equal train/test splitDistributional Gaussian Process Layers for Outlier Detection in Image Segmentation
Source quote
L254: DistGP-Seg (ours) │ 3 │ 0.829 │ 0.823 │ 0.867
2021DistGP-Seg proposed non-standard sliceDice (GM)0.823Brain Tissue Segmentation · split: test · subset=healthy subjects, bottom 10th percentile for white-matter hypointensities · modality=FLAIR · split-protocol=equal train/test splitDistributional Gaussian Process Layers for Outlier Detection in Image Segmentation
Source quote
L254: DistGP-Seg (ours) │ 3 │ 0.829 │ 0.823 │ 0.867
2021DistGP-Seg proposed non-standard sliceDice (WM)0.867Brain Tissue Segmentation · split: test · subset=healthy subjects, bottom 10th percentile for white-matter hypointensities · modality=FLAIR · split-protocol=equal train/test splitDistributional Gaussian Process Layers for Outlier Detection in Image Segmentation
Source quote
L254: DistGP-Seg (ours) │ 3 │ 0.829 │ 0.823 │ 0.867
2021ContIG (PGS; H1) proposedROC-AUC72.72Cardiovascular Risk Prediction · split: test · fine-tunedContIG: Self-supervised Multimodal Contrastive Learning for Medical Imaging with Genetics
Source quote
L209: ContIG (PGS) │ H1 │ 85.93 │ 93.31 │ 78.47 │ 3.176 │ 72.72
2021NNCLR baselineROC-AUC61.95Cardiovascular Risk Prediction · split: test · fine-tunedContIG: Self-supervised Multimodal Contrastive Learning for Medical Imaging with Genetics
Source quote
L206: NNCLR~\cite{nnclr} │ 77.93 │ 91.89 │ 72.06 │ 3.426 │ 61.95
2020Proposed deep generative model-based quality control proposed non-standard slicePearson correlation coefficient r0.96Segmentation Quality Estimation · split: test · n=500 · subset=attacked segmentations · perturbation=white noise at varying variance levelsDeep Generative Model-Based Quality Control for Cardiac MRI Segmentation
Source quote
L99: Quality control performance is assessed in terms of Dice metric prediction accuracy. Pearson correlation coefficient r and mean absolute error (MAE) between predicted Dice and real Dice are calculated. Table 1 compares the quantitative performance of the methods and Fig.\ref{figure3} visualises the predictions. On UK Biobank dataset, the hand-crafted feature method performed the worst. The proposed method achieved a similar performance (r=0.96, MAE=0.07) as the CNN regression method (r=0.97, MAE=0.06). However, on ACDC dataset, the proposed method (r=0.97, MAE=0.03) outperformed the CNN regression method (r=0.97, MAE=0.17) with a smaller MAE. As shown in Fig. \ref{figure3}, on ACDC dataset, the prediction of the proposed method aligns well with the identity line, whereas the CNN regression method clearly deviates from the line, even though the r coefficient is still high.
2020Proposed deep generative model-based quality control proposed non-standard sliceMean absolute error (MAE)0.07Segmentation Quality Estimation · split: test · n=500 · subset=attacked segmentations · perturbation=white noise at varying variance levelsDeep Generative Model-Based Quality Control for Cardiac MRI Segmentation
Source quote
L99: Quality control performance is assessed in terms of Dice metric prediction accuracy. Pearson correlation coefficient r and mean absolute error (MAE) between predicted Dice and real Dice are calculated. Table 1 compares the quantitative performance of the methods and Fig.\ref{figure3} visualises the predictions. On UK Biobank dataset, the hand-crafted feature method performed the worst. The proposed method achieved a similar performance (r=0.96, MAE=0.07) as the CNN regression method (r=0.97, MAE=0.06). However, on ACDC dataset, the proposed method (r=0.97, MAE=0.03) outperformed the CNN regression method (r=0.97, MAE=0.17) with a smaller MAE. As shown in Fig. \ref{figure3}, on ACDC dataset, the prediction of the proposed method aligns well with the identity line, whereas the CNN regression method clearly deviates from the line, even though the r coefficient is still high.
2020ICAM proposedAccuracy0.943Age Classification · split: test · classes=ages 45–60 vs 70–80ICAM: Interpretable Classification via Disentangled Representations and Feature Attribution Mapping
Source quote
L177: We achieved 0.943 accuracy on the test dataset with ICAM on age classification, but cannot compare to VA-GAN, as it cannot perform class prediction. We compare the feature attribution maps and translated images against VA-GAN (Fig.~\ref{fig:biobank_comparison}, and Fig.~\ref{fig:biobank_very_old_young}). While we do not have ground truth maps for a comparison in Biobank, it is commonly described within the neuroscience domain that hippocampal atrophy \cite{o2016cognitive}, decrease in cortical thickness, and the enlargement of the ventricles are often observed with ageing, and are indicative of neurodegeneration \cite{guo2017mri, pacheco2015greater}. We looked for this phenotypic variation in our qualitative analysis. For ICAM we plot variance, and mean FA maps (computed through multiple sampling of the attribute latent space in test time); for VA-GAN we show only FA as it can only generate a single deterministic output. We found that VA-GAN was able to detect some variation in the ventricles and cortex, but that ICAM was able to detect more variability in the ventricles (blue arrows), cortex (green arrows), and in the hippocampus (purple arrow). Interestingly, the variance map detects higher variability in the ventricles and the cortex, which may reflect heterogeneity in the ageing process. We also note that while ICAM is able to change the shape of different brain regions in translation (e.g. shrinking the ventricles, or enlarging the cortical folds), VA-GAN is only able to change the pixel intensities, and does not appear to change the shape. This is a significant advantage for ICAM compared to previous methods, as shape is an important phenotype in many other medical datasets \cite{garcia2018dynamic, kapellou2006abnormal}, and thus is likely to generalise well.
2020Best single-patch network proposedMAE2.46 yearsBrain Age Estimation · split: test · resolution=64x64 · input=3D T1-weighted MRI · backbone=3D ResNet · selection=best of 27 patch models · patch_size=64×64×64 voxelsPatch-Based Brain Age Estimation from MR Images
Source quote
L44: Best single-patch network │ 2.46 │ 0.80
2020All-patch linear-regression ensemble proposedMAE2.13 yearsBrain Age Estimation · split: test · input=3D T1-weighted MRI · ensemble=all-patch linear regression · bias_correction=uncorrectedPatch-Based Brain Age Estimation from MR Images
Source quote
L100: The use of linear regression works better. Specifically, we achieve a MAE of 2.13 years when all the single-patch models are used. Furthermore, when we use only the models of the patches with the most important information for the age of the brain, we achieve a MAE of 2.16 years. Regarding R^2 score, it is 0.85 in both cases. In this case, bias correction is applied as well and we achieve a MAE of 1.96 years, and an R^2 score of 0.87. The scatter plots of the real over predicted ages, before and after bias correction is applied, are shown in Figure \ref{fig4}.
2020All-patch linear-regression ensemble proposedMAE1.96 yearsBrain Age Estimation · split: test · input=3D T1-weighted MRI · ensemble=all-patch linear regression · bias_correction=correctedPatch-Based Brain Age Estimation from MR Images
Source quote
L100: The use of linear regression works better. Specifically, we achieve a MAE of 2.13 years when all the single-patch models are used. Furthermore, when we use only the models of the patches with the most important information for the age of the brain, we achieve a MAE of 2.16 years. Regarding R^2 score, it is 0.85 in both cases. In this case, bias correction is applied as well and we achieve a MAE of 1.96 years, and an R^2 score of 0.87. The scatter plots of the real over predicted ages, before and after bias correction is applied, are shown in Figure \ref{fig4}.
2020All-patch linear-regression ensemble proposedR^2 score0.85Brain Age Estimation · split: test · input=3D T1-weighted MRI · ensemble=all-patch linear regression · bias_correction=uncorrectedPatch-Based Brain Age Estimation from MR Images
Source quote
L100: The use of linear regression works better. Specifically, we achieve a MAE of 2.13 years when all the single-patch models are used. Furthermore, when we use only the models of the patches with the most important information for the age of the brain, we achieve a MAE of 2.16 years. Regarding R^2 score, it is 0.85 in both cases. In this case, bias correction is applied as well and we achieve a MAE of 1.96 years, and an R^2 score of 0.87. The scatter plots of the real over predicted ages, before and after bias correction is applied, are shown in Figure \ref{fig4}.
2020All-patch linear-regression ensemble proposedR^2 score0.87Brain Age Estimation · split: test · input=3D T1-weighted MRI · ensemble=all-patch linear regression · bias_correction=correctedPatch-Based Brain Age Estimation from MR Images
Source quote
L100: The use of linear regression works better. Specifically, we achieve a MAE of 2.13 years when all the single-patch models are used. Furthermore, when we use only the models of the patches with the most important information for the age of the brain, we achieve a MAE of 2.16 years. Regarding R^2 score, it is 0.85 in both cases. In this case, bias correction is applied as well and we achieve a MAE of 1.96 years, and an R^2 score of 0.87. The scatter plots of the real over predicted ages, before and after bias correction is applied, are shown in Figure \ref{fig4}.
2020Baseline model (3D ResNet) baselineMAE2.64 yearsBrain Age Estimation · split: test · input=3D T1-weighted MRI · backbone=3D ResNet · bias_correction=uncorrectedPatch-Based Brain Age Estimation from MR Images
Source quote
L42: Baseline model (uncorrected) │ 2.64 │ 0.77
2019Monotone rate-of-aging model proposedMean correlation between true and reconstructed feature values0.88Feature Reconstruction · split: test · model=monotone rate-of-aging modelInferring Multidimensional Rates of Aging from Cross-Sectional Data
Source quote
L155: xt against the reconstructed posterior mean of xt given (ˆr,ˆb). On a held-out test set, reconstruction was largely accurate, with a mean correlation between true and reconstructed feature values of 0.88 ( Figure G.6). The other baselines performed similarly: PCA, mcPCA, and cPCA did slightly worse, with mean correlations of 0.86,
2019PFGT (optimal tuning parameter selected per SNP) proposedassociation p-value for rs66634505.15E-07Genome Wide Association Study · split: test · tuning=optimal parameter selected per SNP · phenotype=whole-brain FAA Powerful Global Test Statistic for Functional Statistical Inference
Source quote
L295: 5.15E-07
2019PFGT (optimal tuning parameter selected per SNP) proposedassociation p-value for rs111587645.37E-07Genome Wide Association Study · split: test · tuning=optimal parameter selected per SNP · phenotype=whole-brain FAA Powerful Global Test Statistic for Functional Statistical Inference
Source quote
L298: 5.37E-07
2018Proposed CNN, Experiment 2 (reverse-testing/RCA-derived quality supervision) proposedBinary classification accuracy0.906Segmentation Quality Prediction · split: test · modality=CMR · experiment=2 · segmentation=whole-heart · quality-supervision=reverse-testing/RCA-derivedReal-Time Prediction of Segmentation Quality
Source quote
L83: \multicolumn{1}{c}{} │ \multicolumn{1}{|c}{TPR 0.975} │ \multicolumn{1}{c}{FPR 0.060} │ \multicolumn{1}{c|}{Acc. 0.965} │ \multicolumn{1}{c}{TPR 0.879} │ \multicolumn{1}{c}{FPR 0.000} │ \multicolumn{1}{c|}{Acc. 0.906}
2018Proposed spatio-temporal CNN, real data only without data augmentation proposed non-standard slicerecall0.466Motion Artifact Detection · split: test · subset=3,465 2D+time CMR sequences · augmentation=noneDeep Learning using K-space Based Data Augmentation for Automated Cardiac MR Motion Artefact Detection
Source quote
L74: We used a 10-fold stratified cross validation strategy to test all algorithms, in which each image appears once in the test set over all folds. Due to the high class imbalance, over 0.9 accuracy is achieved by most of the techniques in Table \ref{table:1}. We do not rely only on accuracy in our results due to the bias introduced by the imbalanced classes. The interesting comparison for the methods lies in the recall numbers, which quantify the capability of the methods to identify images with artefacts. The results show that the CNN-based technique is capable of identifying the presence of motion artefacts with high recall compared to other techniques. Note in particular that introducing the data with k-space corruption increases the recall number from 0.466 to 0.642. Additional data augmentation improves the recall further to 0.652. All state-of-the-art classification methods reach high accuracy, but Adaboost is capable to reach comparable recall to CNNs without data augmentation. However, the precision of Adaboost is lower compared to the CNN results. Moreover, the F1-score illustrates the improvement of performance using CNN-based methods compared to state-of-the-art machine learning approaches. The F1-score reaches 0.704 with k-space corrupted data and achieves 0.722 with additional data augmentation.
2018Proposed spatio-temporal CNN, real data with k-space-corrupted data augmentation proposed non-standard slicerecall0.642Motion Artifact Detection · split: test · subset=3,465 2D+time CMR sequences · augmentation=k-space-corrupted dataDeep Learning using K-space Based Data Augmentation for Automated Cardiac MR Motion Artefact Detection
Source quote
L74: We used a 10-fold stratified cross validation strategy to test all algorithms, in which each image appears once in the test set over all folds. Due to the high class imbalance, over 0.9 accuracy is achieved by most of the techniques in Table \ref{table:1}. We do not rely only on accuracy in our results due to the bias introduced by the imbalanced classes. The interesting comparison for the methods lies in the recall numbers, which quantify the capability of the methods to identify images with artefacts. The results show that the CNN-based technique is capable of identifying the presence of motion artefacts with high recall compared to other techniques. Note in particular that introducing the data with k-space corruption increases the recall number from 0.466 to 0.642. Additional data augmentation improves the recall further to 0.652. All state-of-the-art classification methods reach high accuracy, but Adaboost is capable to reach comparable recall to CNNs without data augmentation. However, the precision of Adaboost is lower compared to the CNN results. Moreover, the F1-score illustrates the improvement of performance using CNN-based methods compared to state-of-the-art machine learning approaches. The F1-score reaches 0.704 with k-space corrupted data and achieves 0.722 with additional data augmentation.
2018Proposed spatio-temporal CNN, real data with k-space-corrupted data and additional translation augmentation proposed non-standard slicerecall0.652Motion Artifact Detection · split: test · subset=3,465 2D+time CMR sequences · augmentation=k-space-corrupted data and translationDeep Learning using K-space Based Data Augmentation for Automated Cardiac MR Motion Artefact Detection
Source quote
L74: We used a 10-fold stratified cross validation strategy to test all algorithms, in which each image appears once in the test set over all folds. Due to the high class imbalance, over 0.9 accuracy is achieved by most of the techniques in Table \ref{table:1}. We do not rely only on accuracy in our results due to the bias introduced by the imbalanced classes. The interesting comparison for the methods lies in the recall numbers, which quantify the capability of the methods to identify images with artefacts. The results show that the CNN-based technique is capable of identifying the presence of motion artefacts with high recall compared to other techniques. Note in particular that introducing the data with k-space corruption increases the recall number from 0.466 to 0.642. Additional data augmentation improves the recall further to 0.652. All state-of-the-art classification methods reach high accuracy, but Adaboost is capable to reach comparable recall to CNNs without data augmentation. However, the precision of Adaboost is lower compared to the CNN results. Moreover, the F1-score illustrates the improvement of performance using CNN-based methods compared to state-of-the-art machine learning approaches. The F1-score reaches 0.704 with k-space corrupted data and achieves 0.722 with additional data augmentation.
2018Proposed spatio-temporal CNN, real data with k-space-corrupted data augmentation proposed non-standard sliceF1-score0.704Motion Artifact Detection · split: test · subset=3,465 2D+time CMR sequences · augmentation=k-space-corrupted dataDeep Learning using K-space Based Data Augmentation for Automated Cardiac MR Motion Artefact Detection
Source quote
L74: We used a 10-fold stratified cross validation strategy to test all algorithms, in which each image appears once in the test set over all folds. Due to the high class imbalance, over 0.9 accuracy is achieved by most of the techniques in Table \ref{table:1}. We do not rely only on accuracy in our results due to the bias introduced by the imbalanced classes. The interesting comparison for the methods lies in the recall numbers, which quantify the capability of the methods to identify images with artefacts. The results show that the CNN-based technique is capable of identifying the presence of motion artefacts with high recall compared to other techniques. Note in particular that introducing the data with k-space corruption increases the recall number from 0.466 to 0.642. Additional data augmentation improves the recall further to 0.652. All state-of-the-art classification methods reach high accuracy, but Adaboost is capable to reach comparable recall to CNNs without data augmentation. However, the precision of Adaboost is lower compared to the CNN results. Moreover, the F1-score illustrates the improvement of performance using CNN-based methods compared to state-of-the-art machine learning approaches. The F1-score reaches 0.704 with k-space corrupted data and achieves 0.722 with additional data augmentation.
2018Proposed spatio-temporal CNN, real data with k-space-corrupted data and additional translation augmentation proposed non-standard sliceF1-score0.722Motion Artifact Detection · split: test · subset=3,465 2D+time CMR sequences · augmentation=k-space-corrupted data and translationDeep Learning using K-space Based Data Augmentation for Automated Cardiac MR Motion Artefact Detection
Source quote
L74: We used a 10-fold stratified cross validation strategy to test all algorithms, in which each image appears once in the test set over all folds. Due to the high class imbalance, over 0.9 accuracy is achieved by most of the techniques in Table \ref{table:1}. We do not rely only on accuracy in our results due to the bias introduced by the imbalanced classes. The interesting comparison for the methods lies in the recall numbers, which quantify the capability of the methods to identify images with artefacts. The results show that the CNN-based technique is capable of identifying the presence of motion artefacts with high recall compared to other techniques. Note in particular that introducing the data with k-space corruption increases the recall number from 0.466 to 0.642. Additional data augmentation improves the recall further to 0.652. All state-of-the-art classification methods reach high accuracy, but Adaboost is capable to reach comparable recall to CNNs without data augmentation. However, the precision of Adaboost is lower compared to the CNN results. Moreover, the F1-score illustrates the improvement of performance using CNN-based methods compared to state-of-the-art machine learning approaches. The F1-score reaches 0.704 with k-space corrupted data and achieves 0.722 with additional data augmentation.
2017Proposed fully convolutional network (FCN; VGG-16-adapted) proposed non-standard sliceAverage Dice metric0.94Image Segmentation · split: test · subset=short-axis CMR; LV cavity · backbone=VGG-16-adapted · test-subjects=600Human-level CMR image analysis with deep fully convolutional networks
Source quote
L18: By combining FCN with a large-scale annotated dataset, the proposed automated method achieves a high performance in segmenting the LV and RV on short-axis CMR images and the left atrium (LA) and right atrium (RA) on long-axis CMR images. On a short-axis image test set of 600 subjects, it achieves an average Dice metric of 0.94 for the LV cavity, 0.88 for the LV myocardium and 0.90 for the RV cavity. The mean absolute difference between automated measurement and manual measurement was 6.1 mL for LVEDV, 5.3 mL for LVESV, 6.9 gram for LVM, 8.5 mL for RVEDV and 7.2 mL for RVESV. On long-axis image test sets, the average Dice metric was 0.93 for the LA cavity (2-chamber view), 0.95 for the LA cavity (4-chamber view) and 0.96 for the RA cavity (4-chamber view). The performance is comparable to human inter-observer variability.
2017Proposed fully convolutional network (FCN; VGG-16-adapted) proposed non-standard sliceAverage Dice metric0.88Image Segmentation · split: test · subset=short-axis CMR; LV myocardium · backbone=VGG-16-adapted · test-subjects=600Human-level CMR image analysis with deep fully convolutional networks
Source quote
L18: By combining FCN with a large-scale annotated dataset, the proposed automated method achieves a high performance in segmenting the LV and RV on short-axis CMR images and the left atrium (LA) and right atrium (RA) on long-axis CMR images. On a short-axis image test set of 600 subjects, it achieves an average Dice metric of 0.94 for the LV cavity, 0.88 for the LV myocardium and 0.90 for the RV cavity. The mean absolute difference between automated measurement and manual measurement was 6.1 mL for LVEDV, 5.3 mL for LVESV, 6.9 gram for LVM, 8.5 mL for RVEDV and 7.2 mL for RVESV. On long-axis image test sets, the average Dice metric was 0.93 for the LA cavity (2-chamber view), 0.95 for the LA cavity (4-chamber view) and 0.96 for the RA cavity (4-chamber view). The performance is comparable to human inter-observer variability.
2017Proposed fully convolutional network (FCN; VGG-16-adapted) proposed non-standard sliceAverage Dice metric0.90Image Segmentation · split: test · subset=short-axis CMR; RV cavity · backbone=VGG-16-adapted · test-subjects=600Human-level CMR image analysis with deep fully convolutional networks
Source quote
L18: By combining FCN with a large-scale annotated dataset, the proposed automated method achieves a high performance in segmenting the LV and RV on short-axis CMR images and the left atrium (LA) and right atrium (RA) on long-axis CMR images. On a short-axis image test set of 600 subjects, it achieves an average Dice metric of 0.94 for the LV cavity, 0.88 for the LV myocardium and 0.90 for the RV cavity. The mean absolute difference between automated measurement and manual measurement was 6.1 mL for LVEDV, 5.3 mL for LVESV, 6.9 gram for LVM, 8.5 mL for RVEDV and 7.2 mL for RVESV. On long-axis image test sets, the average Dice metric was 0.93 for the LA cavity (2-chamber view), 0.95 for the LA cavity (4-chamber view) and 0.96 for the RA cavity (4-chamber view). The performance is comparable to human inter-observer variability.