UK Biobank
83 papers · 264 extracted observations · phenotype prediction · Markdown · CSV · JSON API
Also indexed as: uk-biobank
Tasks on UK BiobankAll tasks (83)Phenotype Prediction (7)Genome Wide Association Study (4)Image Generation (4)Bmi Prediction (3)Disease Classification (3)Brain Tissue Segmentation (2)Cardiovascular Risk Prediction (2)Disease Detection (2)
TaskPhenotype Prediction (34)Genome Wide Association Study (10)Image Generation (7)Disease Classification (7)Risk Prediction (7)Time to Event Prediction (6)Dementia Risk Prediction (6)
Metricauroc (27)auc (24)mae (22)accuracy (16)concordance index c index (6)average relative efficiency re (6)error rate (6)
Regimefine-tuned (10)5-fold-cross-validation (8)age-conditioned (6)gwas (6)transfer-learning (5)linear-probe (4)
Showing 150 of 156 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2026 | MEVA (Mesh-Enhanced Volumetric Autoencoder) proposed | Genome-wide significant loci | 188 loci | Phenotype Prediction · split: discovery-cohort · gwas | Surface-volume self-supervised representation learning of brain MRI for genetic discoverySource quoteL297: by FUMA locus clumping, MEVA yielded 188 loci, compared with 153 for the volume- |
| 2026 | MEVA (Mesh-Enhanced Volumetric Autoencoder) proposed | Summed SNP heritability (P h²_SNP) | 36.7 | Phenotype Prediction · split: discovery-cohort · gwas | Surface-volume self-supervised representation learning of brain MRI for genetic discoverySource quoteL299: heritability (36.7, versus 33.7 and 10.5; Table 1). Because locus count alone do not |
| 2026 | MEVA (Mesh-Enhanced Volumetric Autoencoder) proposed | Cortical thickness ΔR² | 0.375 | Phenotype Prediction · split: held-out-cohort | Surface-volume self-supervised representation learning of brain MRI for genetic discoverySource quoteL329: substantially increased the cortical thickness variance explained (∆R2 = 0.375 versus |
| 2026 | MEVA (Mesh-Enhanced Volumetric Autoencoder) proposed | Cortical area ΔR² | 0.277 | Phenotype Prediction · split: held-out-cohort | Surface-volume self-supervised representation learning of brain MRI for genetic discoverySource quoteL227: 0.277 |
| 2026 | MEVA (Mesh-Enhanced Volumetric Autoencoder) proposed | Cortical volume ΔR² | 0.266 | Phenotype Prediction · split: held-out-cohort | Surface-volume self-supervised representation learning of brain MRI for genetic discoverySource quoteL228: 0.266 |
| 2026 | CPAgents (two composite-phenotype variants) proposed | Top-rank count across classifier–disease–metric combinations | 56 cases | Disease Classification · endpoints=9 · classifiers=4 | CPAgents: Agentic Composite Phenotype Generation for Cardiac Disease AssociationSource quoteL110: (ii) Diagnostic performance. Table~\ref{tab:main_result} compares disease discrimination using our composite phenotypes with expert-selected single features~\cite{bai2020population} and MESHAgents-based features~\cite{zhang2025multi} across four classifiers and nine disease endpoints. A ranking analysis over all 72 classifier–disease–metric combinations shows that our two composite-phenotype variants occupy the top rank in 56 cases versus 18 for the baselines, and appear in the top two in 51 settings (compared with 33 and 31 for expert-defined and MESHAgents features), indicating consistently competitive and superior performance across diseases rather than gains concentrated in a few favourable tasks. |
| 2026 | PiLA (proposed physiology-guided self-supervised framework) proposed non-standard slice | AUROC | 0.7645 | Aortic Stenosis Screening · split: test · fine-tuned · input=single-beat PPG · pretraining=over 170,000 unlabeled PPG samples · waveform-length=100 points | Aortic Valve Disease Screening from PPG via Physiology-Guided Self-Supervised LearningSource quoteL109: PiLA (Ours) │ 0.7645 │ 0.7755 │ 0.7072 |
| 2026 | PiLA (proposed physiology-guided self-supervised framework) proposed non-standard slice | AUROC | 0.7756 | Aortic Regurgitation Screening · split: test · fine-tuned · input=single-beat PPG · pretraining=over 170,000 unlabeled PPG samples · waveform-length=100 points | Aortic Valve Disease Screening from PPG via Physiology-Guided Self-Supervised LearningSource quoteL122: PiLA (Ours) │ 0.7756 │ 0.7857 │ 0.7490 |
| 2025 | GNN+RV proposed | F1 | 0.716 | Dementia Risk Prediction · split: test · cohort-size=9537 · representation=randomly initialized diagnosis vectors · prediction-horizon=5 years | Predicting Dementia Risk Using Longitudinal Electronic Health Records DataSource quoteL97: 0.716 |
| 2025 | GNN+RV proposed | Sensitivity | 0.761 | Dementia Risk Prediction · split: test · cohort-size=9537 · representation=randomly initialized diagnosis vectors · prediction-horizon=5 years | Predicting Dementia Risk Using Longitudinal Electronic Health Records DataSource quoteL98: 0.761 |
| 2025 | GNN+RV proposed | Specificity | 0.673 | Dementia Risk Prediction · split: test · cohort-size=9537 · representation=randomly initialized diagnosis vectors · prediction-horizon=5 years | Predicting Dementia Risk Using Longitudinal Electronic Health Records DataSource quoteL99: 0.673 |
| 2025 | GNN+RV proposed | J | 0.434 | Dementia Risk Prediction · split: test · cohort-size=9537 · representation=randomly initialized diagnosis vectors · prediction-horizon=5 years | Predicting Dementia Risk Using Longitudinal Electronic Health Records DataSource quoteL100: 0.434 |
| 2025 | GNN+RV proposed | AUCROC | 0.777 | Dementia Risk Prediction · split: test · cohort-size=9537 · representation=randomly initialized diagnosis vectors · prediction-horizon=5 years | Predicting Dementia Risk Using Longitudinal Electronic Health Records DataSource quoteL101: 0.777 |
| 2025 | BERT-style self-supervised nn-MobileNet (pre-trained) proposed | AUC | 0.9997 | Disease Identification · disease=Alzheimer's disease | A BERT-Style Self-Supervised Learning CNN for Disease Identification from Retinal ImagesSource quoteL121: Our research method exhibited strong performance on the AD and PD tasks (Table~\ref{tab:baseline}). On the AD dataset, we achieved good results with 99.33% correctness, a kappa score of 0.9866, and an AUC of 0.9997. On the PD dataset, our method also achieved excellent results with 99.38% correctness, a kappa score of 0.9876, and an AUC of 0.9993. Our results were either on par with or outperform other state-of-the-art methods~\cite{zhou2023foundation,he2022masked}. It is worth noting the RETFound model~\cite{zhou2023foundation} was pre-trained with over 1.6M retinal images, while ours was trained with 176K fundus images. It is unsurprising since, for the same accuracy level, the CNN usually requires far fewer training data than the ViT~\cite{dosovitskiy2020image}. |
| 2025 | BERT-style self-supervised nn-MobileNet (pre-trained) proposed | AUC | 0.9993 | Disease Identification · disease=Parkinson's disease | A BERT-Style Self-Supervised Learning CNN for Disease Identification from Retinal ImagesSource quoteL121: Our research method exhibited strong performance on the AD and PD tasks (Table~\ref{tab:baseline}). On the AD dataset, we achieved good results with 99.33% correctness, a kappa score of 0.9866, and an AUC of 0.9997. On the PD dataset, our method also achieved excellent results with 99.38% correctness, a kappa score of 0.9876, and an AUC of 0.9993. Our results were either on par with or outperform other state-of-the-art methods~\cite{zhou2023foundation,he2022masked}. It is worth noting the RETFound model~\cite{zhou2023foundation} was pre-trained with over 1.6M retinal images, while ours was trained with 176K fundus images. It is unsurprising since, for the same accuracy level, the CNN usually requires far fewer training data than the ViT~\cite{dosovitskiy2020image}. |
| 2025 | MESHAgents (LDA) proposed | AUC | 0.521 | Disease Classification · split: val · 5-fold-cross-validation · disease=PVD · classifier=LDA | Multi-Agent Reasoning for Cardiovascular Imaging Phenotype AnalysisSource quoteL110: \texttt{MESHAgents} │ 0.752 │ 0.691 │ 0.692 │ 0.660 │ 0.715 │ 0.624 │ 0.521 │ 0.462 │ 0.648 │ 0.619 │ 0.568 │ 0.568 │ 0.763 │ 0.685 │ 0.800 │ 0.732 │ 0.616 │ 0.616 |
| 2025 | MESHAgents (LDA) proposed | Recall | 0.462 | Disease Classification · split: val · 5-fold-cross-validation · disease=PVD · classifier=LDA | Multi-Agent Reasoning for Cardiovascular Imaging Phenotype AnalysisSource quoteL110: \texttt{MESHAgents} │ 0.752 │ 0.691 │ 0.692 │ 0.660 │ 0.715 │ 0.624 │ 0.521 │ 0.462 │ 0.648 │ 0.619 │ 0.568 │ 0.568 │ 0.763 │ 0.685 │ 0.800 │ 0.732 │ 0.616 │ 0.616 |
| 2025 | LoRA fine-tuned Mistral-7B-Instruct proposed | AUROC | 0.738 | Clinical Risk Prediction · split: test · fine-tuned · params=7B · backbone=Mistral-7B-Instruct · fine-tuning=LoRA · prediction-horizon=10-year | From Structured Data to Clinical Notes: Robust Clinical Decision Support with Fine-Tuned LLMsSource quoteL78: Figure 2 shows the performance using only the base risk factors as inputs. Both the LLM-based model and LGBM achieved state-of-the-art performance for CVD risk prediction, with an area under the receiver operating characteristic curve (AUROC) of 0.738. |
| 2025 | LLM fine-tuned on structured data (Mistral-7B-Instruct with LoRA) proposed | AUROC | 0.685 | Clinical Risk Prediction · 0-shot · params=7B · backbone=Mistral-7B-Instruct · fine-tuning=LoRA · domain-shift=structured-to-notes · evaluation-input=synthetic clinical notes | From Structured Data to Clinical Notes: Robust Clinical Decision Support with Fine-Tuned LLMsSource quoteL98: 0.685) and improves further with minimal adaptation (0.697 |
| 2025 | RETFound-DINOv2 proposed | Average AUROC | 0.599 | Systemic Disease Prediction · fine-tuned · backbone=DINOv2 · evaluation=external · training_dataset=AlzEye | Generalist versus Specialist Vision Foundation Models for Ocular Disease and OculomicsSource quoteL125: Biobank, which differs in imaging devices and participant demographics. RETFound-DINOv2 showed the strongest external performance, with the highest average AUROC (0.599), compared with |
| 2025 | CADD proposed | AUC | 0.6052 | Disease Detection · metric-input=z-score MAE (1%) · clinical-covariates=S-AdaLN | CADD: Context aware disease deviations via restoration of brain images using normative conditional diffusion modelsSource quoteL443: CADD (Ours) │ 0.6052 │ 6.828E-09 │ 0.6017 │ 2.586E-08 │ 0.5994 │ 5.585E-08 │ 0.5967 │ 1.771E-07 |
| 2025 | SLSE (VAE-encoder spirogram embedding fused with demographic information; CatBoost classifier) proposed non-standard slice | AUROC | 0.7501 | Disease Detection · split: test · subset=selected cohort | Artificial Intelligence-Enabled Spirometry for Early Detection of Right Heart FailureSource quoteL137: We choose area under the receiver operating characteristic curve (AUROC) as the indicator to evaluate model performance. For our task, AUROC is suitable for evaluating the performance of the model in a dataset with an imbalance of positive and negative samples. As shown in the Table \ref{tab:Demographic}, the number of healthy people in the dataset is much higher than that of patients with RHF, which is also in line with the actual clinical situation. Our model finally achieved AUROC=0.7501 on the test set, which shows that the model has good performance in predicting patients with RHF. |
| 2025 | SLSE (VAE-encoder spirogram embedding fused with demographic information; CatBoost classifier) proposed non-standard slice | AUROC | 0.8194 | Disease Detection · split: test · subset=CKD | Artificial Intelligence-Enabled Spirometry for Early Detection of Right Heart FailureSource quoteL142: Ultimately, we find that the model achieves better AUROC performance on VHD, CKD, CHD, diabetes, and smoking subsets than when tested on the entire test set (Figure \ref{fig:subgroup}a), particularly achieving an AUROC=0.8194 on the CKD subset, and an AUROC=0.8413 on the VHD subset. This demonstrates the potential of our model for predicting RHF in CKD and VHD patients. For a excellent AUROC performance on this two subsets, it is possibly because CKD and VHD will increase circulatory load, which significantly exacerbates the symptoms of RHF when combined with it. As for the differences in subgroup distribution, Figure \ref{fig:subgroup}c CKD group shows that the RHF prediction probability distribution for patients with CKD is significantly broader than that for those without CKD, and the median prediction probability is also larger; the same applies to VHD subgroup (Figure \ref{fig:subgroup}c VHD group). The p-values indicate that the model has strong classification ability for the CKD subgroup but weaker classification ability for the VHD subgroup, suggesting that further validation with more VHD patient samples may be needed. |
| 2025 | SLSE (VAE-encoder spirogram embedding fused with demographic information; CatBoost classifier) proposed non-standard slice | AUROC | 0.8413 | Disease Detection · split: test · subset=VHD | Artificial Intelligence-Enabled Spirometry for Early Detection of Right Heart FailureSource quoteL142: Ultimately, we find that the model achieves better AUROC performance on VHD, CKD, CHD, diabetes, and smoking subsets than when tested on the entire test set (Figure \ref{fig:subgroup}a), particularly achieving an AUROC=0.8194 on the CKD subset, and an AUROC=0.8413 on the VHD subset. This demonstrates the potential of our model for predicting RHF in CKD and VHD patients. For a excellent AUROC performance on this two subsets, it is possibly because CKD and VHD will increase circulatory load, which significantly exacerbates the symptoms of RHF when combined with it. As for the differences in subgroup distribution, Figure \ref{fig:subgroup}c CKD group shows that the RHF prediction probability distribution for patients with CKD is significantly broader than that for those without CKD, and the median prediction probability is also larger; the same applies to VHD subgroup (Figure \ref{fig:subgroup}c VHD group). The p-values indicate that the model has strong classification ability for the CKD subgroup but weaker classification ability for the VHD subgroup, suggesting that further validation with more VHD patient samples may be needed. |
| 2025 | CardiacFlow proposed | cycle-DSC | 0.981 | Shape Generation · samples=1000 · setting=3D+t one-step generation · PGK-sigma=1.5 · training-epochs=100 | CardiacFlow: 3D+t Four-Chamber Cardiac Shape Completion and Generation via Flow MatchingSource quoteL136: We conduct ablation studies on three components of CardiacFlow: (i) The PGK frame encoding \mathcal{K}-\sigma(\tau) is substituted by a scalar conditioning variable \tau. (ii) The learnable embedding \epsilon_x is replaced by a Gaussian noise so that the initial value is no longer learnable. (iii) During training, the time t is sampled uniformly instead of Beta sampling. The vFID score and cardiac four-chamber volumes averaged over 1,000 generated 3D+t shapes are presented in Fig. \ref{fig:volume}. It indicates that CardiacFlow learns accurate volume distribution from the UKB dataset. The removal of PGK encoding reduces the cycle-DSC from 0.981 to 0.959. Without learnable initial values or beta sampling, CardiacFlow fails to capture the 3D+t shape variation or motion pattern via one-step generation. |
| 2025 | CardiacFlow proposed | runtime per entire 3D+t sequence | 1.611s | Shape Generation · samples=1000 · setting=runtime per entire 3D+t sequence | CardiacFlow: 3D+t Four-Chamber Cardiac Shape Completion and Generation via Flow MatchingSource quoteL134: 3D+t Shape Generation. We train CardiacFlow on the UKB dataset with completed 3D+t cardiac shapes for 100 epochs using \sigma=1.5 for PGK encoding. CardiacFlow is compared to CHeart \cite{Qiao2023}, spatio-temporal neural distance field (ST-NDF) \cite{sorensen2024stndf}, and a vanilla LRF with one-step generation (T=1). For each baseline method, we randomly generate 1,000 samples for evaluation. The quality of generated 3D+t shapes is measured by the volume Fréchet inception distance (vFID) \cite{heusel2017fid}, which is defined as d_F=\|\mu_1-\mu_2\|^2+tr(\Sigma_1+\Sigma_2-2(\Sigma_1\Sigma_2)^{\frac{1}{2}}) between generated 3D+t shapes \mathcal{N}(\mu_1,\Sigma_1) and UKB test set \mathcal{N}(\mu_2,\Sigma_2), where \mu\in\mathbb{R} (200) is the mean cardiac four-chamber volumes for M=50 frames. The periodic consistency is evaluated by cycle-DSC, i.e., the DSC between the start (\tau=1) and end (\tau=50) frame of a cardiac cycle. The vFID and cycle-DSC are reported in Fig. \ref{fig:shape_generation}, which shows CardiacFlow achieves superior generation quality and periodic consistency than all baselines. CardiacFlow enables high-quality one-step generation, whereas vanilla LRF fails to capture accurate shape distribution in one step. For runtime, CardiacFlow takes 1.611s to generate an entire 3D+t sequence, which is similar to CHeart (1.467s) and ST-NDF (1.472s). An example of 3D+t shapes generated by CardiacFlow is visualised in Fig. \ref{fig:visualization}-d. |
| 2025 | Learned representation (specific model not stated) proposed | Pearson correlation (r) | 0.16 | Bmi Prediction · limited-data | Self-Supervised Representation Learning for Microbiome Improves Downstream Prediction in Data-Limited Settings and Cross-Cohort GeneralizabilitySource quoteL5: The gut microbiome plays a crucial role in human health, but machine learning applications in this field face significant challenges, including limited data availability, high dimensionality, and batch effects across different cohorts. While foundation models have transformed other biological domains, metagenomic data remains relatively under-explored despite its complexity and clinical importance. We developed self-supervised representation learning methods for gut microbiome metagenomic data by implementing multiple approaches on 85,364 samples, including masked autoencoders and novel cross-domain adaptation of single-cell RNA sequencing models. Systematic benchmarking against the standard practice in microbiome machine learning demonstrated significant advantages of our learned representations in limited-data scenarios, improving prediction for age (r = 0.14 vs. 0.06), BMI (r = 0.16 vs. |
| 2025 | RoVTL (frozen backbones) proposed | AUC | 4.6% | Classification · backbone=frozen · tabular-data-availability=0%-100% (average) | No Data? No Problem: Robust Vision-Tabular Learning with Missing ValuesSource quoteL157: Table~\ref{tab_compare} shows the results of RoVTL compared with all baselines. For CAD classification, RoVTL consistently outperforms all other methods under both frozen and trainable configurations, surpassing TIP~\cite{du2024tip} by 4.6% in the frozen setting and 4.42% in the training setting. This improvement clearly demonstrates the benefit of incorporating robustness to missing entries during both pretraining and fine-tuning, unlike TIP, which only considers missingness during pretraining. Furthermore, CF* and MF* outperform their standard counterparts, proving the effectiveness of our downstream task tuning pipeline and showing that it is transferable to different networks and tuning methods. Similar trends are visible for BMI regression, showing our method can generalize to other tasks. While in case of BMI regression MF* achieves the best performance under the trainable backbones setting, the performance of our method under the frozen setting is still the best overall. This behavior suggests the tasks particularly benefits from our pretraining strategy. |
| 2025 | RoVTL (trainable backbones) proposed | AUC | 4.42% | Classification · backbone=trainable · tabular-data-availability=0%-100% (average) | No Data? No Problem: Robust Vision-Tabular Learning with Missing ValuesSource quoteL157: Table~\ref{tab_compare} shows the results of RoVTL compared with all baselines. For CAD classification, RoVTL consistently outperforms all other methods under both frozen and trainable configurations, surpassing TIP~\cite{du2024tip} by 4.6% in the frozen setting and 4.42% in the training setting. This improvement clearly demonstrates the benefit of incorporating robustness to missing entries during both pretraining and fine-tuning, unlike TIP, which only considers missingness during pretraining. Furthermore, CF* and MF* outperform their standard counterparts, proving the effectiveness of our downstream task tuning pipeline and showing that it is transferable to different networks and tuning methods. Similar trends are visible for BMI regression, showing our method can generalize to other tasks. While in case of BMI regression MF* achieves the best performance under the trainable backbones setting, the performance of our method under the frozen setting is still the best overall. This behavior suggests the tasks particularly benefits from our pretraining strategy. |
| 2024 | PSPS proposed | Significant genetic variants | 108 variants | Vqtl Discovery · split: test · fdr=<0.05 · trait=total-body DXA-BMD · labeled-samples=36971 · unlabeled-samples=319548 | Task-Agnostic Machine-Learning-Assisted InferenceSource quoteL348: No genetic variants reached statistical significance under the classical method with only labeled data. \PSPS~identified 108 significant variants with FDR \(< 0.05\) spanning 5 independent loci, showcasing the superior statistical power of \PSPS~(\cref{fig:vqtl.man} and \cref{table:vQTL}). Notably, these significant vQTL cannot be identified by linear regression \citep{miao2024valid}, indicating the different genetic mechanisms controlling outcome levels and variability for DXA-BMD. |
| 2024 | PSPS proposed | Independent loci spanning significant vQTLs | 5 loci | Vqtl Discovery · split: test · fdr=<0.05 · trait=total-body DXA-BMD · labeled-samples=36971 · unlabeled-samples=319548 | Task-Agnostic Machine-Learning-Assisted InferenceSource quoteL348: No genetic variants reached statistical significance under the classical method with only labeled data. \PSPS~identified 108 significant variants with FDR \(< 0.05\) spanning 5 independent loci, showcasing the superior statistical power of \PSPS~(\cref{fig:vqtl.man} and \cref{table:vQTL}). Notably, these significant vQTL cannot be identified by linear regression \citep{miao2024valid}, indicating the different genetic mechanisms controlling outcome levels and variability for DXA-BMD. |
| 2024 | Med-Gemini-Polygenic proposed non-standard slice | AUC | 82.5 | Disease Risk Prediction · split: test · subset=balanced: 200 cases and 200 controls | Advancing Multimodal Medical Capabilities of GeminiSource quoteL1154: Coronary artery disease │ AUC │ 82.5 │ N/A │ 78.5 │ \multirow{14}{*}{\begin{tabular}[c]{@{}c@{}}Ensemble of PRSs and Demographics} |
| 2024 | gpn-msa-polygenic proposed | concordance index (C-index) | 0.5686 | Time to Event Prediction · split: val · phenotype=coronary artery disease · evaluation=10-fold cross-validation · population=Caucasian · related-participants=excluded | DNA language models identify variants predictive across the human phenomeSource quoteL225: 0.5686 |
| 2024 | gpn-msa-polygenic proposed | concordance index (C-index) | 0.5237 | Time to Event Prediction · split: val · phenotype=kidney cancer · evaluation=10-fold cross-validation · population=Caucasian · related-participants=excluded | DNA language models identify variants predictive across the human phenomeSource quoteL226: 0.5237 |
| 2024 | gpn-msa-polygenic proposed | concordance index (C-index) | 0.5999 | Time to Event Prediction · split: val · phenotype=type 2 diabetes · evaluation=10-fold cross-validation · population=Caucasian · related-participants=excluded | DNA language models identify variants predictive across the human phenomeSource quoteL228: 0.5999 |
| 2024 | PSPA estimator proposed non-standard slice | average relative efficiency (RE) | 1.47 | Association Analysis · analysis=AFM associations with age, sex, and BMI · population=South Asian · prediction-model=random forest · prediction-model-r2=0.8 · predictor-training-population=White British | Another look at statistical inference with machine learning-imputed dataSource quoteL275: Table \ref{tab:real-data} presents point estimates, standard errors, and RE, defined as the ratio of the variance of \hat\bbeta^{\text{{lab}}} to the variance of the given estimator, across the two prediction model settings for five estimators: \textcolor{black}{the baseline estimator (\hat\bbeta^{\text{{lab}}}), the \texttt{PPI} estimators (\hat\bbeta^{\text{{PPI}}}, \hat\bbeta^{\text{{PPI}}_a}, \hat\bm{\beta}^{\text{{PPI++}}}), the \texttt{PSPA} estimator (\hat\bbeta^{\text{{PSPA}}}), and the \texttt{CC} estimator (\hat\bbeta^{\text{{CC}}}).} Echoing our theoretical and simulation study results, all methods yield similar point estimates as they are all consistent estimators of the same parameter. In the analysis with the strong prediction model, the predictions provide information on central obesity beyond what is captured by the covariates of interest, satisfying the sufficient condition in Corollary \ref{CC-corollary-1}. Consequently, both \hat\bbeta^{\text{{PPI}}} and \hat\bbeta^{\text{{PPI}}_a} outperform \hat\bbeta^{\text{{lab}}}. \textcolor{black}{In fact, all of the PB inference methods (\hat\bbeta^{\text{{PPI}}}, \hat\bbeta^{\text{{PPI}}_a}, \hat\bbeta^{\text{{PPI++}}}, \hat\bbeta^{\text{{PSPA}}}, and \hat\bbeta^{\text{{CC}}}) yield substantially smaller standard errors compared to \hat\bbeta^{\text{{lab}}}. Among the PB inference methods, \hat\bbeta^{\text{{PPI}}}, \hat\bbeta^{\text{{PPI}}_a}, \hat\bbeta^{\text{{PPI++}}}, and \hat\bbeta^{\text{{PSPA}}} show comparable performance, with average REs of 1.39, 1.39, 1.44, and 1.47, respectively.} \hat\bbeta^{\text{{CC}}} exhibits higher efficiency gains with an average RE of 1.68. The analysis with the weak prediction model highlights the differences in performance between the \texttt{PPI} and \texttt{CC} methods and reinforces the findings in Corollary \ref{CC-corollary-1} and Corollary \ref{CC-corollary-2}. Here, \hat\bbeta^{\text{{PPI}}} and \hat\bbeta^{\text{{PPI}}_a} yield larger standard errors than \hat\bbeta^{\text{{lab}}} for all parameters of interest, with an average RE of 0.52. \textcolor{black}{In contrast, \hat\bbeta^{\text{{CC}}}, as well as \hat\bbeta^{\text{{PSPA}}} and \hat\bbeta^{\text{{PPI++}}}, outperform \hat\bbeta^{\text{{lab}}}, with average RE values of 1.28, 1.29, and 1.16, respectively.} Overall, the \texttt{CC} estimator is the best performing method in terms of efficiency, underscoring its utility in practice. |
| 2024 | PSPA estimator proposed non-standard slice | average relative efficiency (RE) | 1.29 | Association Analysis · analysis=AFM associations with age, sex, and BMI · population=South Asian · prediction-model=random forest · prediction-model-r2=0.5 · predictor-training-population=White British | Another look at statistical inference with machine learning-imputed dataSource quoteL275: Table \ref{tab:real-data} presents point estimates, standard errors, and RE, defined as the ratio of the variance of \hat\bbeta^{\text{{lab}}} to the variance of the given estimator, across the two prediction model settings for five estimators: \textcolor{black}{the baseline estimator (\hat\bbeta^{\text{{lab}}}), the \texttt{PPI} estimators (\hat\bbeta^{\text{{PPI}}}, \hat\bbeta^{\text{{PPI}}_a}, \hat\bm{\beta}^{\text{{PPI++}}}), the \texttt{PSPA} estimator (\hat\bbeta^{\text{{PSPA}}}), and the \texttt{CC} estimator (\hat\bbeta^{\text{{CC}}}).} Echoing our theoretical and simulation study results, all methods yield similar point estimates as they are all consistent estimators of the same parameter. In the analysis with the strong prediction model, the predictions provide information on central obesity beyond what is captured by the covariates of interest, satisfying the sufficient condition in Corollary \ref{CC-corollary-1}. Consequently, both \hat\bbeta^{\text{{PPI}}} and \hat\bbeta^{\text{{PPI}}_a} outperform \hat\bbeta^{\text{{lab}}}. \textcolor{black}{In fact, all of the PB inference methods (\hat\bbeta^{\text{{PPI}}}, \hat\bbeta^{\text{{PPI}}_a}, \hat\bbeta^{\text{{PPI++}}}, \hat\bbeta^{\text{{PSPA}}}, and \hat\bbeta^{\text{{CC}}}) yield substantially smaller standard errors compared to \hat\bbeta^{\text{{lab}}}. Among the PB inference methods, \hat\bbeta^{\text{{PPI}}}, \hat\bbeta^{\text{{PPI}}_a}, \hat\bbeta^{\text{{PPI++}}}, and \hat\bbeta^{\text{{PSPA}}} show comparable performance, with average REs of 1.39, 1.39, 1.44, and 1.47, respectively.} \hat\bbeta^{\text{{CC}}} exhibits higher efficiency gains with an average RE of 1.68. The analysis with the weak prediction model highlights the differences in performance between the \texttt{PPI} and \texttt{CC} methods and reinforces the findings in Corollary \ref{CC-corollary-1} and Corollary \ref{CC-corollary-2}. Here, \hat\bbeta^{\text{{PPI}}} and \hat\bbeta^{\text{{PPI}}_a} yield larger standard errors than \hat\bbeta^{\text{{lab}}} for all parameters of interest, with an average RE of 0.52. \textcolor{black}{In contrast, \hat\bbeta^{\text{{CC}}}, as well as \hat\bbeta^{\text{{PSPA}}} and \hat\bbeta^{\text{{PPI++}}}, outperform \hat\bbeta^{\text{{lab}}}, with average RE values of 1.28, 1.29, and 1.16, respectively.} Overall, the \texttt{CC} estimator is the best performing method in terms of efficiency, underscoring its utility in practice. |
| 2024 | CardioNets proposed | average coefficient of determination (R²) across 82 cardiac phenotypes | 0.310 | Phenotype Prediction · split: val · evaluation=5-fold cross-validation · modalities=paired ECG–CMR · phenotypes=82 cardiac phenotypes | Large-scale cross-modality pretrained model enhances cardiovascular state estimation and cardiomyopathy detection from electrocardiograms: An AI system development and multi-center validation studySource quoteL189: For cardiac phenotype prediction across 82 indicators (e.g., atrial ejection fractions and chamber volumes), CardioNets achieved an average coefficient of determination (R²) of 0.310, outperforming both ECG-only baselines (0.269 and 0.242), though still trailing behind the CMR-based model (0.511). |
| 2024 | CardioNets proposed | AUC improvement over SSL ECG model | 5.5% | Cardiomyopathy Screening · comparator=SSL ECG model | Large-scale cross-modality pretrained model enhances cardiovascular state estimation and cardiomyopathy detection from electrocardiograms: An AI system development and multi-center validation studySource quoteL32: AUC by 38.2% and 5.5%, respectively. In MIMIC, it raised AUC for pulmonary hypertension screening by 3.0% over model trained from SSL. Synthesized CMR images by CardioNets showed 65.0% higher |
| 2024 | CLIP+ITM proposed | balanced accuracy | 3.3% | Stroke Risk Prediction · backbone=CLIP · method=CLIP+ITM · comparison=SCARF | A Self-Supervised Model for Multi-modal Stroke Risk PredictionSource quoteL177: The CLIP+ITM model surpasses the self-supervised tabular (image) data SCARF (SimCLR) model by 2.6% (2.6%) in ROC-AUC, and by 3.3% (5.6%) in balanced accuracy terms. Our framework also demonstrated an AUROC improvement of 0.93% and 7.6% balanced accuracy from the best multi-modal supervised method. Additionally, the proposed model produces well-aligned multi-modal representations in a common, data modality-independent space, which is unattainable with unimodal tabular or imaging data models. Thus, CLIP-ITM effectively leverages complementary and synergistic information from diverse data modalities. |
| 2024 | CLIP+ITM proposed | balanced accuracy | 5.6% | Stroke Risk Prediction · backbone=CLIP · method=CLIP+ITM · comparison=SimCLR | A Self-Supervised Model for Multi-modal Stroke Risk PredictionSource quoteL177: The CLIP+ITM model surpasses the self-supervised tabular (image) data SCARF (SimCLR) model by 2.6% (2.6%) in ROC-AUC, and by 3.3% (5.6%) in balanced accuracy terms. Our framework also demonstrated an AUROC improvement of 0.93% and 7.6% balanced accuracy from the best multi-modal supervised method. Additionally, the proposed model produces well-aligned multi-modal representations in a common, data modality-independent space, which is unattainable with unimodal tabular or imaging data models. Thus, CLIP-ITM effectively leverages complementary and synergistic information from diverse data modalities. |
| 2024 | CLIP+ITM proposed | AUROC | 0.93% | Stroke Risk Prediction · backbone=CLIP · method=CLIP+ITM · comparison=best supervised multimodal method | A Self-Supervised Model for Multi-modal Stroke Risk PredictionSource quoteL177: The CLIP+ITM model surpasses the self-supervised tabular (image) data SCARF (SimCLR) model by 2.6% (2.6%) in ROC-AUC, and by 3.3% (5.6%) in balanced accuracy terms. Our framework also demonstrated an AUROC improvement of 0.93% and 7.6% balanced accuracy from the best multi-modal supervised method. Additionally, the proposed model produces well-aligned multi-modal representations in a common, data modality-independent space, which is unattainable with unimodal tabular or imaging data models. Thus, CLIP-ITM effectively leverages complementary and synergistic information from diverse data modalities. |
| 2024 | CLIP+ITM proposed | balanced accuracy | 7.6% | Stroke Risk Prediction · backbone=CLIP · method=CLIP+ITM · comparison=best supervised multimodal method | A Self-Supervised Model for Multi-modal Stroke Risk PredictionSource quoteL177: The CLIP+ITM model surpasses the self-supervised tabular (image) data SCARF (SimCLR) model by 2.6% (2.6%) in ROC-AUC, and by 3.3% (5.6%) in balanced accuracy terms. Our framework also demonstrated an AUROC improvement of 0.93% and 7.6% balanced accuracy from the best multi-modal supervised method. Additionally, the proposed model produces well-aligned multi-modal representations in a common, data modality-independent space, which is unattainable with unimodal tabular or imaging data models. Thus, CLIP-ITM effectively leverages complementary and synergistic information from diverse data modalities. |
| 2024 | KRR-FP16 proposed non-standard slice | Pearson correlation | 0.8652 | Phenotype Prediction · split: test · phenotype=Allergic Rhinitis · precision=FP16 | Toward Capturing Genetic Epistasis From Multivariate Genome-Wide Association Studies Using Mixed-Precision Kernel Ridge RegressionSource quoteL406: \texttt{Allergic Rhinitis} │ 0.2008 │ 0.8652 │ N/A |
| 2024 | KRR-FP16 proposed non-standard slice | Pearson correlation | 0.8071 | Phenotype Prediction · split: test · phenotype=Hypertension · precision=FP16 | Toward Capturing Genetic Epistasis From Multivariate Genome-Wide Association Studies Using Mixed-Precision Kernel Ridge RegressionSource quoteL403: \texttt{Hypertension} │ 0.2983 │ 0.8071 │ N/A |
| 2024 | TUMSyn proposed | PSNR | 29.81 dB | Image Generation · modality=FLAIR · direction=coronal | Towards General Text-guided Image Synthesis for Customized Multimodal Brain MRI GenerationSource quoteL108: Besides SynthSR, TUMSyn is also compared with ArSSR~\cite{wu2022arbitrary}, which is an SR model that can support arbitrary-scale upsampling and particularly trained on this dataset. Notably, across all the three simulated FLAIR images, TUMSyn achieves the best performance in terms of PSNR and SSIM. For example, compared to ArSSR, TUMSyn improves PSNR of images scanned in the coronal direction from 29.08 dB to 29.81 dB. Our method outperforms SynthSR by up to 23.2% (from 22.91 dB to 29.82 dB) in PSNR (Fig.\ref{fig:Fig.5} f). |
| 2024 | Proposed multi-modal self-supervised model proposed | balanced accuracy | 7.6% | Myocardial Infarction Diagnosis · fine-tuned | Enhancing Cardiovascular Disease Prediction through Multi-Modal Self-Supervised LearningSource quoteL178: As a baseline, we train the NN \cite{erickson2020autogluon} in a supervised manner on tabular data, ECG signals, and a combination of them. We compared our method with simple NN supervised approaches due to the limited availability of annotated data, which restricted our ability to explore more advanced supervised methods. We extracted the features from ECG signal \cite{lubba2019catch22,ji2022time} for concatenating them with tabular features. As seen in table \ref{tab:self_supervised}, the performance of supervised learning on tabular data only and ECG signals only results in balanced accuracy of 54% and 66% respectively. Training the model on a combination of ECG signals and tabular information results in 65% balanced accuracy which is likely due to the overfitting on the small task-specific data using only 1524 samples with balanced diseased and healthy individuals. However, our approach with pre-training the model on multiple modalities including images and fine-tuning on labeled data outperforms the supervised method by 7.6% increase in balanced accuracy. |
| 2024 | IdenBAT proposed non-standard slice | PAD (↓), All | 3.52 | Brain Age Transformation · split: test · slice=97th axial · subset=longitudinal pairs; age gap >2 years · target-ages=48–80 · input-dimension=2D | IdenBAT: Disentangled representation learning for identity-preserved brain age transformationSource quoteL217: IdenBAT (Ours) │ 26.314 │ 0.924 │ 0.0026 │ 3.52 │ 3.27 │ 3.05 │ 3.56 │ 3.14 │ 4.72 |
| 2024 | IdenBAT proposed non-standard slice | PAD (↓), All | 4.68 | Brain Age Transformation · split: test · subset=longitudinal pairs; age gap >2 years · target-ages=48–80 · input-dimension=3D | IdenBAT: Disentangled representation learning for identity-preserved brain age transformationSource quoteL219: IdenBAT (Ours) │ 29.653 │ 0.958 │ 0.0020 │ 4.68 │ 5.24 │ 3.47 │ 4.26 │ 5.27 │ 5.35 |
| 2024 | IdenBAT proposed non-standard slice | SSIM (↑) | 0.958 | Brain Age Transformation · split: test · subset=longitudinal pairs; age gap >2 years · input-dimension=3D | IdenBAT: Disentangled representation learning for identity-preserved brain age transformationSource quoteL219: IdenBAT (Ours) │ 29.653 │ 0.958 │ 0.0020 │ 4.68 │ 5.24 │ 3.47 │ 4.26 │ 5.27 │ 5.35 |
| 2024 | DeepSpiro proposed non-standard slice | AUROC | 0.8328 | Copd Detection · subset=all (complete dataset) | Deep learning for detecting and early predicting chronic obstructive pulmonary disease from spirogram time seriesSource quoteL61: DeepSpiro │ 0.8328 │ 0.3570 │ 0.3950 |
| 2024 | DeepSpiro proposed non-standard slice | AUPRC | 0.3570 | Copd Detection · subset=all (complete dataset) | Deep learning for detecting and early predicting chronic obstructive pulmonary disease from spirogram time seriesSource quoteL61: DeepSpiro │ 0.8328 │ 0.3570 │ 0.3950 |
| 2024 | DeepSpiro proposed non-standard slice | F1-Score | 0.3950 | Copd Detection · subset=all (complete dataset) | Deep learning for detecting and early predicting chronic obstructive pulmonary disease from spirogram time seriesSource quoteL61: DeepSpiro │ 0.8328 │ 0.3570 │ 0.3950 |
| 2024 | EyeFound proposed | AUROC | 0.634 | Stroke Prediction · imaging-modality=CFP | EyeFound: A Multimodal Generalist Foundation Model for Ophthalmic ImagingSource quoteL111: PD, and MI in the UK Biobank dataset using ocular images. Our model outperformed RETFound in predicting stroke, dementia, and PD using CFP, achieving AUROC scores of 0.634, 0.547, and 0.571, respectively (all P<0.05). The same trend is also observed in AUPR, with scores of 0.624, 0.583, and |
| 2024 | EyeFound proposed | AUROC | 0.547 | Dementia Prediction · imaging-modality=CFP | EyeFound: A Multimodal Generalist Foundation Model for Ophthalmic ImagingSource quoteL111: PD, and MI in the UK Biobank dataset using ocular images. Our model outperformed RETFound in predicting stroke, dementia, and PD using CFP, achieving AUROC scores of 0.634, 0.547, and 0.571, respectively (all P<0.05). The same trend is also observed in AUPR, with scores of 0.624, 0.583, and |
| 2024 | EyeFound proposed | AUROC | 0.571 | Parkinsons Disease Prediction · imaging-modality=CFP | EyeFound: A Multimodal Generalist Foundation Model for Ophthalmic ImagingSource quoteL111: PD, and MI in the UK Biobank dataset using ocular images. Our model outperformed RETFound in predicting stroke, dementia, and PD using CFP, achieving AUROC scores of 0.634, 0.547, and 0.571, respectively (all P<0.05). The same trend is also observed in AUPR, with scores of 0.624, 0.583, and |
| 2024 | Net1D + Dist Loss (paper's “Ours”) proposed | Pearson correlation coefficient | 0.474 | Vascular Age Estimation · split: test · held-out-fraction=40% | Deep Imbalanced Regression to Estimate Vascular Age from PPG Data: a Novel Digital Biomarker for Cardiovascular HealthSource quoteL154: + Ours │ \textbf{\textcolor{red}{0.474}} |
| 2024 | Net1D + Dist Loss (paper's “Ours”) proposed non-standard slice | MAE | 9.495 | Vascular Age Estimation · split: test · few-shot · subset=labels with occurrence probability below one-third of the maximum | Deep Imbalanced Regression to Estimate Vascular Age from PPG Data: a Novel Digital Biomarker for Cardiovascular HealthSource quoteL171: + Ours │ \textbf{\textcolor{red}{0.686}} │ \textbf{\textcolor{red}{9.495}} │ \textbf{\textcolor{red}{12.029}} │ \textbf{\textcolor{red}{0.158}} │ \textbf{\textcolor{red}{4.963}} │ 6.851 │ \textbf{\textcolor{red}{59.846}} │ \textbf{\textcolor{red}{75.815}} |
| 2024 | PCH proposed | Estimated causal effect β_X→Y | 0.352 | Causal Inference · outcome=SBP · exposure=BMI · sample-size=161988 · candidate-ivs=1553 | Discovery and inference of possibly bi-directional causal relationships with invalid instrumental variablesSource quoteL585: PCH │ 1 │ 0.352 │ (0.281,0.422) │ -0.009 │ (-0.017,-0.001) |
| 2024 | PCH proposed | Estimated causal effect β_Y→X | -0.009 | Causal Inference · outcome=BMI · exposure=SBP · sample-size=161988 · candidate-ivs=1553 | Discovery and inference of possibly bi-directional causal relationships with invalid instrumental variablesSource quoteL585: PCH │ 1 │ 0.352 │ (0.281,0.422) │ -0.009 │ (-0.017,-0.001) |
| 2024 | BrainLM proposed | R2 | 0.464 | Masked Patch Prediction · split: test | BrainLM: A foundation model for brain activity recordingsSource quoteL70: On the UKB test data, BrainLM achieved an average R2 score of 0.464 on the prediction of masked patches, indicating strong generalization on unseen recordings from the same distribution. Critically, BrainLM also generalized well to the HCP dataset, achieving a R2 score of 0.278. Despite differences in cohort and acquisition details, BrainLM could effectively model brain dynamics in this entirely new distribution. Figure 3 shows sample reconstructions on both UKB and HCP recordings. We found that the model generalization scales with data size and model size, showing strong model scaling (see Figure 4). Overall, these results demonstrate BrainLM’s ability to learn robust representations of fMRI recordings that generalize across datasets. This highlights the advantages of large-scale pretraining for learning widely applicable models of brain activity. |
| 2024 | BrainLM 650M (fine-tuned) proposed | R2 | 0.098 | Future Brain State Prediction · fine-tuned · params=650M · model-size=650M · input-horizon=180 time steps · forecast-horizon=20 time steps | BrainLM: A foundation model for brain activity recordingsSource quoteL151: 0.098 |
| 2024 | BrainLM 650M (fine-tuned) proposed | R (Pearson correlation) | 0.313 | Future Brain State Prediction · fine-tuned · params=650M · model-size=650M · input-horizon=180 time steps · forecast-horizon=20 time steps | BrainLM: A foundation model for brain activity recordingsSource quoteL152: 0.313 |
| 2024 | L-optimal subsampling proposed | running time | 3.287 hours | Survival Analysis · subsampling-factor=c=100 | Mastering Rare Event Analysis: Optimal Subsample Size in Logistic and Cox RegressionsSource quoteL455: We set c_0=15 and investigated the RE based on Step 1.5. The results are summarized in Fig. \ref{fig:UKB_relative} (a) and Table \ref{UKB_results_RR}. Notably, c=100 with the L-optimal subsampling approach (i.e., approximately 500K ``dummy-observations" instead of nearly 350 million) proves sufficient. However, in subsequent analyses, we also applied our proposed algorithms for c=40 and 160, for comparison purposes. Table \ref{UKB_RMSE_frob} presents the RMSE of the estimators with respect to the full-data PL estimator, the Frobenius norm of the covariance matrices of the estimators, and their running times. Clearly, the optimal methods outperform uniform subsampling regarding both RMSE and Forbenius norm, with the A-optimal method consistently exhibiting somewhat better values than the L-optimal method, as expected. While the running time required for the full dataset is 14.5 hours, the time required for the L-optimal method with c=100 is reduced to 3.287 hours, with minimal loss in terms of efficiency, as demonstrated in Figures \ref{fig:UKB_relative} (b) and (c). |
| 2024 | X-Diffusion (1-slice input) proposed | Test 3D PSNR | 22.42 | 3D Reconstruction · split: test · input-slices=1 | X-Diffusion: Generating Detailed 3D MRI Volumes From a Single Image Using Cross-Sectional Diffusion ModelsSource quoteL131: X-Diffusion (ours) │ 23.10 │ 22.42 │ 25.20 │ 23.04 │ 29.43 │ 25.26 │ 31.25 │ 26.85 │ 33.27 │ 27.44 │ 35.48 │ 29.01 |
| 2023 | DisPred proposed | AUC | 0.6692 | Disease Risk Prediction · split: test · phenotype=Alzheimer's disease family-history proxy · population=admixed | Improving genetic risk prediction across diverse population by disentangling ancestry representationsSource quoteL91: South Asians (SAS), East Asians (EAS), Americans (AMR), Africans (AFR), and Europeans (EUR), and an admixed group composed of individuals not passing cut-off in any ancestry. Since UKB primarily comprises European participants, we set the threshold low to obtain enough admixed and non-EUR participants for our analysis. In both datasets, EUR ancestry individuals correspond to the largest proportion (48% for the ADSP and 92% for the UKB). Admixed individuals are the second largest group (44% for the ADSP and 6% for the UKB). For both cohorts, we consider four test datasets: i) all test participants, ii) European participants, iii) admixed participants, and iv) non-European participants, primarily AFR for the ADSP and primarily SAS for the UKB. Panel B presents the result for all the test participants, and the proposed DisPred leads to the best result for ADSP and the joint best result for UKB (Lasso-EUR being marginally better than DisPred). The analysis restricted to European participants is shown in panel C. In this case, Lasso-EUR achieves the best result, and the proposed method produces the second-best result for both datasets. In admixed individuals, DisPred produces the best result for both UKB and ADSP (Panel D). In UKB, the performance on admixed individuals (best AUC: 0.6692 by DisPred) is equivalent to the one |
| 2023 | HeLM (tabular + spirogram) proposed | AUROC | 0.75 | Asthma Prediction · modalities=tabular+spirogram | Multimodal LLMs for health grounded in individual-specific dataSource quoteL7: Using data from the UK Biobank, we show that HeLM can effectively use demographic and clinical features in addition to high-dimensional time-series data to estimate disease risk. For example, HeLM achieves an AUROC of 0.75 for asthma prediction when combining tabular and spirogram data modalities compared with 0.49 when only using tabular data. Overall, we find that HeLM outperforms or performs at parity with classical machine learning approaches across a selection of eight binary traits. Furthermore, we investigate the downstream uses of this model such as its generalizability to out-of-distribution traits and its ability to power conversations around individual health and wellness. |
| 2023 | proposed pairwise pseudolikelihood proposed non-standard slice | number of SNPs significantly associated with increased UBC risk | 11 SNPs | Risk Association Analysis · split: test · subset=31 previously associated SNPs · disease=urinary bladder cancer · significance-threshold=BH-adjusted p < 0.05 | Unlocking Retrospective Prevalent Information in EHRs -- a Pairwise Pseudolikelihood ApproachSource quoteL30: Employing a Cox model \citep{cox1972regression}, we observe higher statistical power with the proposed approach compared to the standard partial-likelihood (PL) estimator, adjusted for left truncation and excluding prevalent observations. Of 31 tested SNPs, 11 were significantly associated with increased UBC risk using the proposed approach, compared to six SNPs detected by the standard PL estimator. The Benjamini-Hochberg (BH) \citep{benjamini1995controlling} procedure for multiple-testing was used, with significance threshold set at 0.05. |
| 2023 | Genetic InfoMax (GIM) proposed | All loci | 40 loci | Genome Wide Association Study · cohort=28,489 white British participants · method=BOLT-LMM · representation=first 10 principal components · significance-threshold=5e-9 | Genetic InfoMax: Exploring Mutual Information Maximization in High-Dimensional Imaging Genetics StudiesSource quoteL186: 40 │ 15 │ 1.3681 │ 0.3723~\textpm~0.0305 |
| 2023 | Genetic InfoMax (GIM) proposed | Unique loci | 15 loci | Genome Wide Association Study · cohort=28,489 white British participants · method=BOLT-LMM · representation=first 10 principal components · significance-threshold=5e-9 | Genetic InfoMax: Exploring Mutual Information Maximization in High-Dimensional Imaging Genetics StudiesSource quoteL186: 40 │ 15 │ 1.3681 │ 0.3723~\textpm~0.0305 |
| 2023 | Genetic InfoMax (GIM) proposed | Estimated MI | 1.3681 | Mutual Information Estimation · split: test · estimator=JSE · representation=first 10 principal components | Genetic InfoMax: Exploring Mutual Information Maximization in High-Dimensional Imaging Genetics StudiesSource quoteL186: 40 │ 15 │ 1.3681 │ 0.3723~\textpm~0.0305 |
| 2023 | Unsupervised Phenotype Ensembles (UPE; CoMA latent phenotypes) proposed | Autoencoder runs with a genome-wide-significant locus association | 35 runs | Genome Wide Association Study · locus=PLN · phenotype=LV end-diastolic meshes · retained-runs=36 · latent-dimensions=8 or 16 | Unsupervised ensemble-based phenotyping helps enhance the discoverability of genes related to heart morphologySource quoteL88: chr6:117672972-118963115 │ PLN │ 35 │ 1.8 × 10 (-22) |
| 2023 | Unsupervised Phenotype Ensembles (UPE; CoMA latent phenotypes) proposed | Autoencoder runs with a genome-wide-significant locus association | 34 runs | Genome Wide Association Study · locus=TTN · phenotype=LV end-diastolic meshes · retained-runs=36 · latent-dimensions=8 or 16 | Unsupervised ensemble-based phenotyping helps enhance the discoverability of genes related to heart morphologySource quoteL89: chr2:178553183-181312739 │ TTN │ 34 │ 5.3 × 10 (-14) |
| 2023 | Unsupervised Phenotype Ensembles (UPE; CoMA latent phenotypes) proposed | Autoencoder runs with a genome-wide-significant locus association | 31 runs | Genome Wide Association Study · locus=TBX5 · phenotype=LV end-diastolic meshes · retained-runs=36 · latent-dimensions=8 or 16 | Unsupervised ensemble-based phenotyping helps enhance the discoverability of genes related to heart morphologySource quoteL90: chr12:113986709-115036602 │ TBX5 │ 31 │ 5.5 × 10 (-12) |
| 2023 | Latent Diffusion Models proposed | FID | 2.1986 | Image Generation · split: test · resolution=160×224 | Generative AI for Medical Imaging: extending the MONAI FrameworkSource quoteL62: UK Biobank │ 2D Brain Slice MRI │ 160 × 224 │ 2.1986 │ 0.5368 │ 0.9876 |
| 2023 | Bernoulli-sigmoid model with uniform unobservables (α=1) and prevalence constraint p(Y=1)=0.02 proposed | AUC | 0.63 | Risk Prediction · split: test · alpha=1 · outcome=breast cancer · population=tested (T=1) · prevalence-constraint=p(Y=1)=0.02 | Domain constraints improve risk prediction when outcome data is missingSource quoteL415: We also consider a baseline model which treats the untested group as negative; this is equivalent to predicting p(T_i=1, Y_i=1|X_i), an approach used in prior selective labels work \citep{shen2021artificial, ko2020detection, rastogi2023learn}. We find that, though this baseline no longer learns an implausible age trend, it underperforms our model in terms of AUC (AUC is 0.60 on the tested population vs. 0.63 for our model; AUC is 0.60 on the untested population vs. 0.63 for our model) and quintile ratio (quintile ratio on the tested population is 2.4 vs. 3.3 for our model; quintile ratio for both models is 2.5 on the untested population). This baseline is a special case of our model with the prevalence constraint set to p(Y=1|T=0) = 0, an implausibly low prevalence constraint. In light of this, it makes sense that this baseline learns a more plausible age trend, but underperforms our model overall. |
| 2023 | Bernoulli-sigmoid model with uniform unobservables (α=1) and prevalence constraint p(Y=1)=0.02 proposed | AUC | 0.63 | Risk Prediction · split: test · alpha=1 · outcome=breast cancer · population=untested (T=0) · prevalence-constraint=p(Y=1)=0.02 | Domain constraints improve risk prediction when outcome data is missingSource quoteL415: We also consider a baseline model which treats the untested group as negative; this is equivalent to predicting p(T_i=1, Y_i=1|X_i), an approach used in prior selective labels work \citep{shen2021artificial, ko2020detection, rastogi2023learn}. We find that, though this baseline no longer learns an implausible age trend, it underperforms our model in terms of AUC (AUC is 0.60 on the tested population vs. 0.63 for our model; AUC is 0.60 on the untested population vs. 0.63 for our model) and quintile ratio (quintile ratio on the tested population is 2.4 vs. 3.3 for our model; quintile ratio for both models is 2.5 on the untested population). This baseline is a special case of our model with the prevalence constraint set to p(Y=1|T=0) = 0, an implausibly low prevalence constraint. In light of this, it makes sense that this baseline learns a more plausible age trend, but underperforms our model overall. |
| 2023 | Bernoulli-sigmoid model with uniform unobservables (α=1) and prevalence constraint p(Y=1)=0.02 proposed non-standard slice | quintile ratio | 3.3 | Risk Prediction · split: test · alpha=1 · outcome=breast cancer · population=tested (T=1) · prevalence-constraint=p(Y=1)=0.02 | Domain constraints improve risk prediction when outcome data is missingSource quoteL415: We also consider a baseline model which treats the untested group as negative; this is equivalent to predicting p(T_i=1, Y_i=1|X_i), an approach used in prior selective labels work \citep{shen2021artificial, ko2020detection, rastogi2023learn}. We find that, though this baseline no longer learns an implausible age trend, it underperforms our model in terms of AUC (AUC is 0.60 on the tested population vs. 0.63 for our model; AUC is 0.60 on the untested population vs. 0.63 for our model) and quintile ratio (quintile ratio on the tested population is 2.4 vs. 3.3 for our model; quintile ratio for both models is 2.5 on the untested population). This baseline is a special case of our model with the prevalence constraint set to p(Y=1|T=0) = 0, an implausibly low prevalence constraint. In light of this, it makes sense that this baseline learns a more plausible age trend, but underperforms our model overall. |
| 2023 | PSPA proposed | Estimated standard error of the linear-regression coefficient | 3.74E-03 | Risk Factor Regression · split: val · covariate=biological sex · imputation=SoftImpute · labeled-fraction=10% | Assumption-lean and data-adaptive post-prediction inferenceSource quoteL493: \widehat{\text{SE}} │ 3.74E-03 │ 3.74E-03 │ 3.74E-03 │ 3.82E-03 │ 3.80E-03 │ 3.81E-03 |
| 2023 | PSPA proposed | Estimated standard error of the linear-regression coefficient | 3.74E-03 | Risk Factor Regression · split: val · covariate=age · imputation=SoftImpute · labeled-fraction=10% | Assumption-lean and data-adaptive post-prediction inferenceSource quoteL493: \widehat{\text{SE}} │ 3.74E-03 │ 3.74E-03 │ 3.74E-03 │ 3.82E-03 │ 3.80E-03 │ 3.81E-03 |
| 2023 | PSPA proposed | Estimated standard error of the linear-regression coefficient | 3.74E-03 | Risk Factor Regression · split: val · covariate=physical activity · imputation=SoftImpute · labeled-fraction=10% | Assumption-lean and data-adaptive post-prediction inferenceSource quoteL493: \widehat{\text{SE}} │ 3.74E-03 │ 3.74E-03 │ 3.74E-03 │ 3.82E-03 │ 3.80E-03 │ 3.81E-03 |
| 2023 | Proposed method (adaptive graph learning) proposed | MAE | 3.61 | Age Regression · runs=10 | Multimodal brain age estimation using interpretable adaptive population-graph learningSource quoteL149: For the evaluation of the pipeline in the regression task, we use Mean Absolute Error (MAE), and the Pearson Correlation Coefficient (r score). A summary of the performance of the proposed and competing methods is available at Table \ref{tab1:regr}. Linear regression (MAE=3.82) outperforms GCNs trained on static graphs whether these are based on the node features (MAE=3.87) or leverage the phenotypes (MAE=3.98). The DGM outperforms the baselines (MAE=3.72). The proposed method outperforms all others (MAE=3.61). |
| 2023 | 2D-Slice model with pretrained encoder proposed | MAE | 2.715 | Brain Age Prediction · encoder=pretrained | Transferring Models Trained on Natural Images to 3D MRI via Position Encoded Slice ModelsSource quoteL152: Our main goal with these experiments is to demonstrate improvement in performance due to natural image pretraining. Nevertheless, another interesting outcome is that 2D-Slice models with pretrained encoders are the best for both tasks, outperforming the 3D-CNN as well. For the AD task, we observe that 3D-CNN has a balanced accuracy of 88.40. In contrast, models with pretrained ResNet-18 encoder model have a balanced accuracy of 88.6 when using slices along the axial direction (both with and without position encodings). Similarly, the best MAE with the pretrained model for brain age prediction is 2.715 compared to 2.792 MAE with 3D-CNN. Finally, We also evaluated if increasing the size of the pretrained encoder may lead to more gain by employing ResNet-50 as the encoder for brain age prediction. |
| 2023 | Gene-SGAN proposed | Discovery-set associations significant after Bonferroni correction | 7 associations | Genetic Association · split: replication | Gene-SGAN: a method for discovering disease subtypes with imaging and genetic signatures via multi-view weakly-supervised deep clusteringSource quoteL271: 7 and Supplementary eMethod 4) to test the replicability rate of the SNP-subtype associations in two independent splits. Specifically, we equally split the patient data into the discovery set (N=8207) and the replication set (N=8207). Using the discovery set, we re-derived 5 subtypes related to hypertension using Gene-SGAN and further found 15 significant SNP-subtype associations (Method 8) after Bonferroni correction. Among these, 10 SNP-subtype associations (66.7%) were replicated in the replication set at B-H corrected significance, and 7 (46.7%) were significant after Bonferroni corrections for multiple comparisons (Supplementary eMethod 4). |
| 2023 | IB2 (β̂_ib2) proposed | ASE of the BMI coefficient | 0.114 | Regression · sample-size=295 · external-data=ARIC summary information | Integrative data analysis where partial covariates have complex non-linear effects by using summary information from an external dataSource quoteL368: BMI │ 0.656 │ 0.114 │ 5.763 │ <0.001 |
| 2022 | Weight2+CLFA (cross-laterality feature alignment pre-training) proposed | R^2_CVD (WHO-CVD regression) | 0.5703 | Cvd Risk Estimation · pretraining=Weight2+CLFA | Camera Adaptation for Fundus-Image-Based CVD Risk EstimationSource quoteL107: Weight2+CLFA │ 0.5703 │ 0.2144 │ 0.4937 │ 0.3741 │ 0.3557 │ 0.1597 |
| 2022 | Proposed conditional generative model proposed | KL divergence | 0.0248 | Synthetic Data Generation · split: test · age-conditioned · clinical-measure=LVM | Generative Modelling of the Ageing Heart with Cross-Sectional Imaging and Clinical DataSource quoteL135: 0.0248 |
| 2022 | Proposed conditional generative model proposed | Wasserstein distance | 15.2829 | Synthetic Data Generation · split: test · age-conditioned · clinical-measure=LVM | Generative Modelling of the Ageing Heart with Cross-Sectional Imaging and Clinical DataSource quoteL136: 15.2829 |
| 2022 | Proposed conditional generative model proposed | KL divergence | 0.0334 | Synthetic Data Generation · split: test · age-conditioned · clinical-measure=LVEDV | Generative Modelling of the Ageing Heart with Cross-Sectional Imaging and Clinical DataSource quoteL137: 0.0334 |
| 2022 | Causal Shape Model, f_X(z_X^i,u_X;\cdot) proposed | Median VED | 0.8900 mm | 3D Shape Reconstruction · split: test · latent-dimension=16 | Deep Structural Causal Shape ModelsSource quoteL380: 16 │ 0.9006 ± 0.10 │ 0.8900 │ 2.0421 |
| 2022 | Causal Shape Model, f_X(z_X^i,u_X;\cdot) proposed | Chamfer Distance | 2.0421 mm | 3D Shape Reconstruction · split: test · latent-dimension=16 | Deep Structural Causal Shape ModelsSource quoteL380: 16 │ 0.9006 ± 0.10 │ 0.8900 │ 2.0421 |
| 2022 | POPDx proposed | AUROC | 0.71 | Phenotype Recognition · few-shot · sampling-ratio=positive:negative 1:10 · training-samples=0–10 per phenotype | POPDx: An Automated Framework for Patient Phenotyping across 392,246 Individuals in the UK Biobank StudySource quoteL155: Under the Receiver Operating Characteristic Curve) scores of 0.71 and 0.74 for phenotypes with |
| 2022 | POPDx proposed | AUROC | 0.74 | Phenotype Recognition · few-shot · sampling-ratio=positive:negative 1:10 · training-samples=10–100 per phenotype | POPDx: An Automated Framework for Patient Phenotyping across 392,246 Individuals in the UK Biobank StudySource quoteL155: Under the Receiver Operating Characteristic Curve) scores of 0.71 and 0.74 for phenotypes with |
| 2022 | POPDx proposed | AUROC | 0.68 | Phenotype Recognition · 0-shot · sampling-ratio=positive:negative 1:10 · training-samples=0 per phenotype | POPDx: An Automated Framework for Patient Phenotyping across 392,246 Individuals in the UK Biobank StudySource quoteL157: Curve) scores improve with training size. We also investigated performance for phenotypes with no patient sample in the training dataset. For these, POPDx achieves an AUROC score of 0.68 and an AUPRC score of 0.24, which are 74% and 218% higher than those of the logistic regression baseline. A sampling ratio of positive to negative patients of 1:10 is consistently used to report the |
| 2022 | POPDx proposed | AUPRC | 0.24 | Phenotype Recognition · 0-shot · sampling-ratio=positive:negative 1:10 · training-samples=0 per phenotype | POPDx: An Automated Framework for Patient Phenotyping across 392,246 Individuals in the UK Biobank StudySource quoteL157: Curve) scores improve with training size. We also investigated performance for phenotypes with no patient sample in the training dataset. For these, POPDx achieves an AUROC score of 0.68 and an AUPRC score of 0.24, which are 74% and 218% higher than those of the logistic regression baseline. A sampling ratio of positive to negative patients of 1:10 is consistently used to report the |
| 2022 | POPDx proposed | AUROC (Mean) | 0.8141 | Phenotype Recognition · phenotypes=131 · sampling-ratio=positive:negative 1:10 · phenotype-category=circulatory system | POPDx: An Automated Framework for Patient Phenotyping across 392,246 Individuals in the UK Biobank StudySource quoteL175: 0.8141 0.0725 0.3695 0.1238 (GI) Diseases of the digestive system |
| 2022 | POPDx proposed | AUPRC (Mean) | 0.3695 | Phenotype Recognition · phenotypes=131 · sampling-ratio=positive:negative 1:10 · phenotype-category=circulatory system | POPDx: An Automated Framework for Patient Phenotyping across 392,246 Individuals in the UK Biobank StudySource quoteL175: 0.8141 0.0725 0.3695 0.1238 (GI) Diseases of the digestive system |
| 2022 | DART (Deep Approximation of Retinal Traits) proposed | Pearson r | 0.9572 | Fractal Dimension Estimation · split: test · degradation=none | Robust and efficient computation of retinal fractal dimension through deep approximationSource quoteL83: None │ 0.9160 │ 0.9572 (0.0000) │ 0.9561 (0.0000) │ y=0.01 + 1.00x |
| 2022 | DART (Deep Approximation of Retinal Traits) proposed | Pearson r | 0.8817 | Fractal Dimension Estimation · split: test · degradation=severity-5 | Robust and efficient computation of retinal fractal dimension through deep approximationSource quoteL88: Severity 5 │ 0.7773 │ 0.8817 (0.0000) │ 0.8840 (0.0000) │ y=0.02 + 0.99x |
| 2022 | BLESS-VI proposed non-standard slice | Detected effects | 8,257 voxels | Lesion Effect Detection · subset=white-matter lesions · threshold=posterior inclusion probability 0.5 · sample-size=2000 | Bayesian Lesion Estimation with a Structured Spike-and-Slab PriorSource quoteL380: For inference, we threshold the test statistics of BB-BLESS at a significance level of 5%. In contrast, for BLESS-VI we threshold the posterior probability of inclusion at 0.5 in order to acquire its respective binary significance map. Hence, we exploit variable selection as a means to conduct inference. On the other hand, the mass-univariate approach Firth regression ignores any form of spatial dependence and hence requires the application of a multiple testing correction where we adjust the p-values with a FDR correction \citep{benjamini1995} at a significance level of 5%. The results in Figure \ref{fig: ukbb_bless_firth} indicate a slightly larger extent of spatial activation for BB-BLESS and BLESS-VI compared to Firth regression for a sample size of N=2,000. For the covariate age, in the regression model estimated via Firth regression 10,171 voxels are deemed active based on uncorrected p-values. On the other hand, only 6,278 voxels pass the FDR adjusted threshold whereas in BB-BLESS 8,385 effect locations are detected by utilizing the full posterior to derive test statistics and similarly in BLESS-VI 8,257 effects are detected via simply thresholding the posterior inclusion probabilities. |
| 2022 | DistGP-Seg proposed | DICE WM | 0.867 | Brain Tissue Segmentation · split: test · input=FLAIR · cohort=normal subjects · architecture=three-hidden-layer | Distributional Gaussian Processes Layers for Out-of-Distribution DetectionSource quoteL841: DistGP-Seg (ours) │ 3 │ 0.829 │ 0.823 │ 0.867 |
| 2021 | VR-Net (R-L2-6×1) proposed non-standard slice | Dice (LV) | 0.948 | Image Registration · split: test · slices=basal, mid-ventricular, apical · subset=100 test subjects · structure=LV | Learning a Model-Driven Variational Network for Deformable Image RegistrationSource quoteL326: In Table \ref{tab:ukbb} and \ref{tab:acdc}, we show the quantitative results obtained by using different methods on UK Biobank and ACDC. In the tables, one can see that VR-Net outperforms iterative methods and data-driven methods on both datasets for almost all anatomical structures. On UK Biobank, RC-Net achieves the best result on RV in terms of both Dice and HD of 0.005 and 0.42mm respectively compared to that obtained by our best configuration of (R-\rm{L}_2-6×1). However, in terms of Dice, VR-Net achieves 0.948 on LV and 0.764 on Myo, outperforming 3×RC-Net by 0.004 and by 0.028, respectively. In terms of HD for LV and Myo, our VR-Net improves 3×RC-Net from 4.28mm to 3.90mm and from 7.39mm to 6.49mm, respectively. On average, the proposed VR-Net achieves a better Dice and HD score than 3×RC-Net, making our VR-Net the best method on this dataset. |
| 2021 | 3D-StyleGAN (2mm-fd64) proposed non-standard slice | FID-Sag | 106.9 | Image Generation · split: test · resolution=2mm · feature-dim=64 | 3D-StyleGAN: A Style-Based Generative Adversarial Network for Generative Modeling of Three-Dimensional Medical ImagesSource quoteL131: 2mm-fd64 │ 4497 (898.53) │ 0.93 (0.12) │ 106.9 │ 71.3 │ 90.2 |
| 2021 | 3D-StyleGAN (2mm-fd64) proposed non-standard slice | FID-Ax | 71.3 | Image Generation · split: test · resolution=2mm · feature-dim=64 | 3D-StyleGAN: A Style-Based Generative Adversarial Network for Generative Modeling of Three-Dimensional Medical ImagesSource quoteL131: 2mm-fd64 │ 4497 (898.53) │ 0.93 (0.12) │ 106.9 │ 71.3 │ 90.2 |
| 2021 | 3D-StyleGAN (2mm-fd96) proposed non-standard slice | FID-Cor | 88.5 | Image Generation · split: test · resolution=2mm · feature-dim=96 | 3D-StyleGAN: A Style-Based Generative Adversarial Network for Generative Modeling of Three-Dimensional Medical ImagesSource quoteL132: 2mm-fd96 │ 4475 (539.38) │ 0.96 (0.04) │ 138.3 │ 83.2 │ 88.5 |
| 2021 | DistGP-Seg proposed non-standard slice | Dice (CSF) | 0.829 | Brain Tissue Segmentation · split: test · subset=healthy subjects, bottom 10th percentile for white-matter hypointensities · modality=FLAIR · split-protocol=equal train/test split | Distributional Gaussian Process Layers for Outlier Detection in Image SegmentationSource quoteL254: DistGP-Seg (ours) │ 3 │ 0.829 │ 0.823 │ 0.867 |
| 2021 | DistGP-Seg proposed non-standard slice | Dice (GM) | 0.823 | Brain Tissue Segmentation · split: test · subset=healthy subjects, bottom 10th percentile for white-matter hypointensities · modality=FLAIR · split-protocol=equal train/test split | Distributional Gaussian Process Layers for Outlier Detection in Image SegmentationSource quoteL254: DistGP-Seg (ours) │ 3 │ 0.829 │ 0.823 │ 0.867 |
| 2021 | DistGP-Seg proposed non-standard slice | Dice (WM) | 0.867 | Brain Tissue Segmentation · split: test · subset=healthy subjects, bottom 10th percentile for white-matter hypointensities · modality=FLAIR · split-protocol=equal train/test split | Distributional Gaussian Process Layers for Outlier Detection in Image SegmentationSource quoteL254: DistGP-Seg (ours) │ 3 │ 0.829 │ 0.823 │ 0.867 |
| 2021 | VQ-VAE + Transformer + Masked Residuals + Different Orderings proposed | best possible DICE-score (⌈DICE⌉) | 0.232 | Anomaly Segmentation | Unsupervised Brain Anomaly Detection and Segmentation with TransformersSource quoteL133: VQ-VAE + Transformer + Masked Residuals + Different Orderings (Ours) │ \bfseries 0.232 |
| 2021 | Transfer - weighted-lasso proposed | Numbers of discoveries | 24 discoveries | Genome Wide Association · transfer-learning · phenotype=height · population=African · resolution=425 kb | Transfer Learning in Genome-Wide Association Studies with KnockoffsSource quoteL492: \multirow{-6}{*}{\raggedright\arraybackslash African} │ 425 │ 2 │ 3 │ 0 │ 24 |
| 2021 | Transfer - weighted-lasso proposed | Numbers of discoveries | 8 discoveries | Genome Wide Association · transfer-learning · phenotype=BMI · population=African · resolution=425 kb | Transfer Learning in Genome-Wide Association Studies with KnockoffsSource quoteL530: \multirow{-6}{*}{\raggedright\arraybackslash African} │ 425 │ 1 │ 1 │ 0 │ 8 |
| 2021 | Transfer - adaptive (gam) proposed | Numbers of discoveries | 5 discoveries | Genome Wide Association · transfer-learning · phenotype=diabetes · population=African · resolution=425 | Transfer Learning in Genome-Wide Association Studies with KnockoffsSource quoteL607: \multirow{-6}{*}{\raggedright\arraybackslash African} │ 425 │ 1 │ 5 │ 2 │ 2 |
| 2021 | ContIG (PGS; H1) proposed | ROC-AUC | 72.72 | Cardiovascular Risk Prediction · split: test · fine-tuned | ContIG: Self-supervised Multimodal Contrastive Learning for Medical Imaging with GeneticsSource quoteL209: ContIG (PGS) │ H1 │ 85.93 │ 93.31 │ 78.47 │ 3.176 │ 72.72 |
| 2021 | Multi-environment knockoff filter (MEKF), accumulation test (Acc.) proposed | number of consistent discoveries | 13 discoveries | Genetic Association · resolution=single-SNP · consistent-environments=2 | Searching for consistent associations with a multi-environment knockoff filterSource quoteL1194: single-SNP │ 13 │ 0 │ 0 │ 2 │ 0 │ 0 │ 0 │ 0 │ 0 │ 0 │ 0 │ 0 |
| 2021 | Multi-environment knockoff filter (MEKF), accumulation test (Acc.) proposed | number of consistent discoveries | 9 discoveries | Genetic Association · resolution=single-SNP · consistent-environments=2 | Searching for consistent associations with a multi-environment knockoff filterSource quoteL1222: single-SNP │ 9 │ 0 │ 0 │ 3 │ 0 │ 0 │ 0 │ 0 │ 0 │ 0 │ 0 │ 0 |
| 2021 | Multi-environment knockoff filter (MEKF), accumulation test (Acc.) proposed | number of consistent discoveries | 33 discoveries | Genetic Association · resolution=20-kb · consistent-environments=2 | Searching for consistent associations with a multi-environment knockoff filterSource quoteL1198: 20 │ 33 │ 29 │ 25 │ 0 │ 0 │ 0 │ 0 │ 0 │ 0 │ 0 │ 0 │ 0 |
| 2021 | Multi-environment knockoff filter (MEKF), accumulation test (Acc.) proposed | number of consistent discoveries | 27 discoveries | Genetic Association · resolution=20-kb · consistent-environments=2 | Searching for consistent associations with a multi-environment knockoff filterSource quoteL1226: 20 │ 27 │ 20 │ 26 │ 16 │ 0 │ 0 │ 2 │ 0 │ 0 │ 0 │ 0 │ 0 |
| 2021 | R-Split proposed non-standard slice | 95%-coverage confidence-interval lower bound | -1.20 mm Hg | Subgroup Analysis · subset=857 unrelated white British participants from top or bottom 0.2% of genetic risk · adjustment=612 genetic variants and other covariates · comparison=smoking cessation; low- vs high-genetic-risk groups | Sharp Inference on Selected Subgroups in Observational StudiesSource quoteL466: Lower bound │ -2.29 │ -1.20 │ 1.27 │ -3.78 |
| 2020 | Step2Heart embeddings (input variant unspecified in the score sentence) proposed | AUC | 0.93 | Sex Prediction · linear-probe | Self-supervised transfer learning of physiological representations from free-living wearable dataSource quoteL388: Generalizing in downstream tasks. Quantitatively, the embeddings achieved strong results in predicting variables like users' sex, height, PAEE and weight (0.93, 0.82, 0.80 and 0.77 AUC respectively). Also, BMI, VO_2max and age are moderately predictable (0.70 AUC). The pure acceleration model (A/T) moderately predicts Resting HR (0.62 AUC), but this does not apply to the (A/R/T) since it already includes the RHR as input. Generally, the A/R/T model outperforms the A/T model showing that using the RHR as input is helpful, as discussed in the previous sections. |
| 2020 | Step2Heart embeddings (input variant unspecified in the score sentence) proposed | AUC | 0.82 | Height Prediction · linear-probe | Self-supervised transfer learning of physiological representations from free-living wearable dataSource quoteL388: Generalizing in downstream tasks. Quantitatively, the embeddings achieved strong results in predicting variables like users' sex, height, PAEE and weight (0.93, 0.82, 0.80 and 0.77 AUC respectively). Also, BMI, VO_2max and age are moderately predictable (0.70 AUC). The pure acceleration model (A/T) moderately predicts Resting HR (0.62 AUC), but this does not apply to the (A/R/T) since it already includes the RHR as input. Generally, the A/R/T model outperforms the A/T model showing that using the RHR as input is helpful, as discussed in the previous sections. |
| 2020 | Step2Heart embeddings (input variant unspecified in the score sentence) proposed | AUC | 0.80 | Paee Prediction · linear-probe | Self-supervised transfer learning of physiological representations from free-living wearable dataSource quoteL388: Generalizing in downstream tasks. Quantitatively, the embeddings achieved strong results in predicting variables like users' sex, height, PAEE and weight (0.93, 0.82, 0.80 and 0.77 AUC respectively). Also, BMI, VO_2max and age are moderately predictable (0.70 AUC). The pure acceleration model (A/T) moderately predicts Resting HR (0.62 AUC), but this does not apply to the (A/R/T) since it already includes the RHR as input. Generally, the A/R/T model outperforms the A/T model showing that using the RHR as input is helpful, as discussed in the previous sections. |
| 2020 | Step2Heart embeddings (input variant unspecified in the score sentence) proposed | AUC | 0.70 | Bmi Prediction · linear-probe | Self-supervised transfer learning of physiological representations from free-living wearable dataSource quoteL388: Generalizing in downstream tasks. Quantitatively, the embeddings achieved strong results in predicting variables like users' sex, height, PAEE and weight (0.93, 0.82, 0.80 and 0.77 AUC respectively). Also, BMI, VO_2max and age are moderately predictable (0.70 AUC). The pure acceleration model (A/T) moderately predicts Resting HR (0.62 AUC), but this does not apply to the (A/R/T) since it already includes the RHR as input. Generally, the A/R/T model outperforms the A/T model showing that using the RHR as input is helpful, as discussed in the previous sections. |
| 2020 | Proposed deep generative model-based quality control proposed non-standard slice | Pearson correlation coefficient r | 0.96 | Segmentation Quality Estimation · split: test · n=500 · subset=attacked segmentations · perturbation=white noise at varying variance levels | Deep Generative Model-Based Quality Control for Cardiac MRI SegmentationSource quoteL99: Quality control performance is assessed in terms of Dice metric prediction accuracy. Pearson correlation coefficient r and mean absolute error (MAE) between predicted Dice and real Dice are calculated. Table 1 compares the quantitative performance of the methods and Fig.\ref{figure3} visualises the predictions. On UK Biobank dataset, the hand-crafted feature method performed the worst. The proposed method achieved a similar performance (r=0.96, MAE=0.07) as the CNN regression method (r=0.97, MAE=0.06). However, on ACDC dataset, the proposed method (r=0.97, MAE=0.03) outperformed the CNN regression method (r=0.97, MAE=0.17) with a smaller MAE. As shown in Fig. \ref{figure3}, on ACDC dataset, the prediction of the proposed method aligns well with the identity line, whereas the CNN regression method clearly deviates from the line, even though the r coefficient is still high. |
| 2020 | Proposed deep generative model-based quality control proposed non-standard slice | Mean absolute error (MAE) | 0.07 | Segmentation Quality Estimation · split: test · n=500 · subset=attacked segmentations · perturbation=white noise at varying variance levels | Deep Generative Model-Based Quality Control for Cardiac MRI SegmentationSource quoteL99: Quality control performance is assessed in terms of Dice metric prediction accuracy. Pearson correlation coefficient r and mean absolute error (MAE) between predicted Dice and real Dice are calculated. Table 1 compares the quantitative performance of the methods and Fig.\ref{figure3} visualises the predictions. On UK Biobank dataset, the hand-crafted feature method performed the worst. The proposed method achieved a similar performance (r=0.96, MAE=0.07) as the CNN regression method (r=0.97, MAE=0.06). However, on ACDC dataset, the proposed method (r=0.97, MAE=0.03) outperformed the CNN regression method (r=0.97, MAE=0.17) with a smaller MAE. As shown in Fig. \ref{figure3}, on ACDC dataset, the prediction of the proposed method aligns well with the identity line, whereas the CNN regression method clearly deviates from the line, even though the r coefficient is still high. |
| 2020 | PIF-A proposed non-standard slice | balanced accuracy (Bal. acc.) | 88.41% | Disease Classification · subset=small data set; 371 samples | Harnessing spatial homogeneity of neuroimaging data: patch individual filter layers for CNNsSource quoteL132: UK Biobank │ PIF-A │ 93.75% (1.09) │ 48.9 │ 88.41% (3.52) │ 72.7 |
| 2020 | ICAM proposed | Accuracy | 0.943 | Age Classification · split: test · classes=ages 45–60 vs 70–80 | ICAM: Interpretable Classification via Disentangled Representations and Feature Attribution MappingSource quoteL177: We achieved 0.943 accuracy on the test dataset with ICAM on age classification, but cannot compare to VA-GAN, as it cannot perform class prediction. We compare the feature attribution maps and translated images against VA-GAN (Fig.~\ref{fig:biobank_comparison}, and Fig.~\ref{fig:biobank_very_old_young}). While we do not have ground truth maps for a comparison in Biobank, it is commonly described within the neuroscience domain that hippocampal atrophy \cite{o2016cognitive}, decrease in cortical thickness, and the enlargement of the ventricles are often observed with ageing, and are indicative of neurodegeneration \cite{guo2017mri, pacheco2015greater}. We looked for this phenotypic variation in our qualitative analysis. For ICAM we plot variance, and mean FA maps (computed through multiple sampling of the attribute latent space in test time); for VA-GAN we show only FA as it can only generate a single deterministic output. We found that VA-GAN was able to detect some variation in the ventricles and cortex, but that ICAM was able to detect more variability in the ventricles (blue arrows), cortex (green arrows), and in the hippocampus (purple arrow). Interestingly, the variance map detects higher variability in the ventricles and the cortex, which may reflect heterogeneity in the ageing process. We also note that while ICAM is able to change the shape of different brain regions in translation (e.g. shrinking the ventricles, or enlarging the cortical folds), VA-GAN is only able to change the pixel intensities, and does not appear to change the shape. This is a significant advantage for ICAM compared to previous methods, as shape is an important phenotype in many other medical datasets \cite{garcia2018dynamic, kapellou2006abnormal}, and thus is likely to generalise well. |
| 2020 | Best single-patch network proposed | MAE | 2.46 years | Brain Age Estimation · split: test · resolution=64x64 · input=3D T1-weighted MRI · backbone=3D ResNet · selection=best of 27 patch models · patch_size=64×64×64 voxels | Patch-Based Brain Age Estimation from MR ImagesSource quoteL44: Best single-patch network │ 2.46 │ 0.80 |
| 2020 | All-patch linear-regression ensemble proposed | MAE | 2.13 years | Brain Age Estimation · split: test · input=3D T1-weighted MRI · ensemble=all-patch linear regression · bias_correction=uncorrected | Patch-Based Brain Age Estimation from MR ImagesSource quoteL100: The use of linear regression works better. Specifically, we achieve a MAE of 2.13 years when all the single-patch models are used. Furthermore, when we use only the models of the patches with the most important information for the age of the brain, we achieve a MAE of 2.16 years. Regarding R^2 score, it is 0.85 in both cases. In this case, bias correction is applied as well and we achieve a MAE of 1.96 years, and an R^2 score of 0.87. The scatter plots of the real over predicted ages, before and after bias correction is applied, are shown in Figure \ref{fig4}. |
| 2020 | All-patch linear-regression ensemble proposed | MAE | 1.96 years | Brain Age Estimation · split: test · input=3D T1-weighted MRI · ensemble=all-patch linear regression · bias_correction=corrected | Patch-Based Brain Age Estimation from MR ImagesSource quoteL100: The use of linear regression works better. Specifically, we achieve a MAE of 2.13 years when all the single-patch models are used. Furthermore, when we use only the models of the patches with the most important information for the age of the brain, we achieve a MAE of 2.16 years. Regarding R^2 score, it is 0.85 in both cases. In this case, bias correction is applied as well and we achieve a MAE of 1.96 years, and an R^2 score of 0.87. The scatter plots of the real over predicted ages, before and after bias correction is applied, are shown in Figure \ref{fig4}. |
| 2020 | All-patch linear-regression ensemble proposed | R^2 score | 0.85 | Brain Age Estimation · split: test · input=3D T1-weighted MRI · ensemble=all-patch linear regression · bias_correction=uncorrected | Patch-Based Brain Age Estimation from MR ImagesSource quoteL100: The use of linear regression works better. Specifically, we achieve a MAE of 2.13 years when all the single-patch models are used. Furthermore, when we use only the models of the patches with the most important information for the age of the brain, we achieve a MAE of 2.16 years. Regarding R^2 score, it is 0.85 in both cases. In this case, bias correction is applied as well and we achieve a MAE of 1.96 years, and an R^2 score of 0.87. The scatter plots of the real over predicted ages, before and after bias correction is applied, are shown in Figure \ref{fig4}. |
| 2020 | All-patch linear-regression ensemble proposed | R^2 score | 0.87 | Brain Age Estimation · split: test · input=3D T1-weighted MRI · ensemble=all-patch linear regression · bias_correction=corrected | Patch-Based Brain Age Estimation from MR ImagesSource quoteL100: The use of linear regression works better. Specifically, we achieve a MAE of 2.13 years when all the single-patch models are used. Furthermore, when we use only the models of the patches with the most important information for the age of the brain, we achieve a MAE of 2.16 years. Regarding R^2 score, it is 0.85 in both cases. In this case, bias correction is applied as well and we achieve a MAE of 1.96 years, and an R^2 score of 0.87. The scatter plots of the real over predicted ages, before and after bias correction is applied, are shown in Figure \ref{fig4}. |
| 2019 | Monotone rate-of-aging model proposed | Mean correlation between true and reconstructed feature values | 0.88 | Feature Reconstruction · split: test · model=monotone rate-of-aging model | Inferring Multidimensional Rates of Aging from Cross-Sectional DataSource quoteL155: xt against the reconstructed posterior mean of xt given (ˆr,ˆb). On a held-out test set, reconstruction was largely accurate, with a mean correlation between true and reconstructed feature values of 0.88 ( Figure G.6). The other baselines performed similarly: PCA, mcPCA, and cPCA did slightly worse, with mean correlations of 0.86, |
| 2019 | Formula-corrected cross-trait PRS R² proposed | Corrected R² (×100%) | 7.2696% | Phenotype Prediction · traits=ADHD-PLIC-RD | On Genetic Correlation Estimation With Summary Statistics From Genome-Wide Association StudiesSource quoteL1580: ADHD-PLIC-RD │ -0.0444 │ 0.0112 │ 0.0001 │ 0.1974 │ 7.2696 |
| 2019 | Formula-corrected cross-trait PRS R² proposed | Corrected R² (×100%) | 6.6136% | Phenotype Prediction · traits=ADHD-PLIC-L2 | On Genetic Correlation Estimation With Summary Statistics From Genome-Wide Association StudiesSource quoteL1577: ADHD-PLIC-L2 │ -0.0431 │ 0.0113 │ 0.0001 │ 0.1862 │ 6.6136 |
| 2019 | Formula-corrected cross-trait PRS R² proposed | Corrected R² (×100%) | 5.9635% | Phenotype Prediction · traits=ADHD-FXST-L1 | On Genetic Correlation Estimation With Summary Statistics From Genome-Wide Association StudiesSource quoteL1572: ADHD-FXST-L1 │ -0.0373 │ 0.0110 │ 0.0007 │ 0.1392 │ 5.9635 |
| 2019 | Reverse Classification Accuracy (RCA) proposed | binary classification accuracy | 0.988 | Segmentation Quality Control · split: val · segmenter=random-forest · sample-size=400 · segmentation=whole-heart | Automated Quality Control in Image Segmentation: Application to the UK Biobank Cardiac MR Imaging StudySource quoteL188: WH │ 0.988 │ 0.979 │ 0.000 │ \multirow{2}{*}{0.029} │ \multirow{2}{*}{4.445} │ \multirow{2}{*}{5.504} │ \multirow{2}{*}{15.11} |
| 2019 | Reverse Classification Accuracy (RCA) proposed | MAE of predicted DSC | 0.029 | Segmentation Quality Control · split: val · segmenter=random-forest · sample-size=400 · segmentation=whole-heart | Automated Quality Control in Image Segmentation: Application to the UK Biobank Cardiac MR Imaging StudySource quoteL188: WH │ 0.988 │ 0.979 │ 0.000 │ \multirow{2}{*}{0.029} │ \multirow{2}{*}{4.445} │ \multirow{2}{*}{5.504} │ \multirow{2}{*}{15.11} |
| 2019 | Reverse Classification Accuracy (RCA) proposed non-standard slice | binary classification accuracy | 0.954 | Segmentation Quality Control · trees=500 · depths=5, 40 · segmenter=random-forest · sample-size=4800 · segmentation=whole-heart | Automated Quality Control in Image Segmentation: Application to the UK Biobank Cardiac MR Imaging StudySource quoteL222: WH │ 0.954 │ 0.966 │ 0.148 │ \multirow{2}{*}{0.035} │ \multirow{2}{*}{1.156} │ \multirow{2}{*}{2.762} │ \multirow{2}{*}{12.52} |
| 2019 | Reverse Classification Accuracy (RCA) proposed non-standard slice | MAE of predicted DSC | 0.035 | Segmentation Quality Control · trees=500 · depths=5, 40 · segmenter=random-forest · sample-size=4800 · segmentation=whole-heart | Automated Quality Control in Image Segmentation: Application to the UK Biobank Cardiac MR Imaging StudySource quoteL222: WH │ 0.954 │ 0.966 │ 0.148 │ \multirow{2}{*}{0.035} │ \multirow{2}{*}{1.156} │ \multirow{2}{*}{2.762} │ \multirow{2}{*}{12.52} |
| 2019 | Reverse Classification Accuracy (RCA) proposed non-standard slice | binary classification accuracy | 0.978 | Segmentation Quality Control · trees=500 · depths=5, 40 · segmenter=random-forest · sample-size=4800 · segmentation=whole-heart | Automated Quality Control in Image Segmentation: Application to the UK Biobank Cardiac MR Imaging StudySource quoteL223: 0.978 │ 0.984 │ 0.027 |
| 2019 | Reverse Classification Accuracy (RCA) proposed non-standard slice | binary classification accuracy | 0.998 | Segmentation Quality Control · segmenter=cnn · sample-size=900 · segmentation=whole-heart | Automated Quality Control in Image Segmentation: Application to the UK Biobank Cardiac MR Imaging StudySource quoteL244: WH │ 0.998 │ 1.000 │ 0.000 │ \multirow{2}{*}{0.089} │ \multirow{2}{*}{0.460} │ \multirow{2}{*}{0.509} │ \multirow{2}{*}{1.698} |
| 2019 | PFGT (optimal tuning parameter selected per SNP) proposed | association p-value for rs6663450 | 5.15E-07 | Genome Wide Association Study · split: test · tuning=optimal parameter selected per SNP · phenotype=whole-brain FA | A Powerful Global Test Statistic for Functional Statistical InferenceSource quoteL295: 5.15E-07 |
| 2019 | PFGT (optimal tuning parameter selected per SNP) proposed | association p-value for rs11158764 | 5.37E-07 | Genome Wide Association Study · split: test · tuning=optimal parameter selected per SNP · phenotype=whole-brain FA | A Powerful Global Test Statistic for Functional Statistical InferenceSource quoteL298: 5.37E-07 |
| 2018 | Proposed CNN, Experiment 1 (manual-GT DSC supervision) proposed | Binary classification accuracy | 0.965 | Segmentation Quality Prediction · modality=CMR · experiment=1 · segmentation=whole-heart · DSC-threshold=0.70 · quality-supervision=manual-GT DSC | Real-Time Prediction of Segmentation QualitySource quoteL83: \multicolumn{1}{c}{} │ \multicolumn{1}{|c}{TPR 0.975} │ \multicolumn{1}{c}{FPR 0.060} │ \multicolumn{1}{c|}{Acc. 0.965} │ \multicolumn{1}{c}{TPR 0.879} │ \multicolumn{1}{c}{FPR 0.000} │ \multicolumn{1}{c|}{Acc. 0.906} |
| 2018 | Proposed CNN, Experiment 2 (reverse-testing/RCA-derived quality supervision) proposed | Binary classification accuracy | 0.906 | Segmentation Quality Prediction · split: test · modality=CMR · experiment=2 · segmentation=whole-heart · quality-supervision=reverse-testing/RCA-derived | Real-Time Prediction of Segmentation QualitySource quoteL83: \multicolumn{1}{c}{} │ \multicolumn{1}{|c}{TPR 0.975} │ \multicolumn{1}{c}{FPR 0.060} │ \multicolumn{1}{c|}{Acc. 0.965} │ \multicolumn{1}{c}{TPR 0.879} │ \multicolumn{1}{c}{FPR 0.000} │ \multicolumn{1}{c|}{Acc. 0.906} |
| 2018 | Proposed quality-prediction CNN (each network) proposed | Average inference time per network | 600 ms | Segmentation Quality Prediction · unit=ms per network · modality=CMR · inference-device=CPU | Real-Time Prediction of Segmentation QualitySource quoteL62: On average, the inference time for each network was of the order 600 ms on CPU and 40 ms on GPU. This is over 10,000 times faster than with RCA (660 seconds) whilst maintaining good accuracy. In an automated image analysis pipeline, this method would deliver excellent performance at high-speed and at large-scale. When paired with a real-time segmentation method it would be possible provide real-time feedback during image acquisition whether an acquired image is of sufficient quality for the downstream segmentation task. |
| 2018 | Proposed quality-prediction CNN (each network) proposed | Average inference time per network | 40 ms | Segmentation Quality Prediction · unit=ms per network · modality=CMR · inference-device=GPU | Real-Time Prediction of Segmentation QualitySource quoteL62: On average, the inference time for each network was of the order 600 ms on CPU and 40 ms on GPU. This is over 10,000 times faster than with RCA (660 seconds) whilst maintaining good accuracy. In an automated image analysis pipeline, this method would deliver excellent performance at high-speed and at large-scale. When paired with a real-time segmentation method it would be possible provide real-time feedback during image acquisition whether an acquired image is of sufficient quality for the downstream segmentation task. |
| 2018 | Proposed spatio-temporal CNN, real data only without data augmentation proposed non-standard slice | recall | 0.466 | Motion Artifact Detection · split: test · subset=3,465 2D+time CMR sequences · augmentation=none | Deep Learning using K-space Based Data Augmentation for Automated Cardiac MR Motion Artefact DetectionSource quoteL74: We used a 10-fold stratified cross validation strategy to test all algorithms, in which each image appears once in the test set over all folds. Due to the high class imbalance, over 0.9 accuracy is achieved by most of the techniques in Table \ref{table:1}. We do not rely only on accuracy in our results due to the bias introduced by the imbalanced classes. The interesting comparison for the methods lies in the recall numbers, which quantify the capability of the methods to identify images with artefacts. The results show that the CNN-based technique is capable of identifying the presence of motion artefacts with high recall compared to other techniques. Note in particular that introducing the data with k-space corruption increases the recall number from 0.466 to 0.642. Additional data augmentation improves the recall further to 0.652. All state-of-the-art classification methods reach high accuracy, but Adaboost is capable to reach comparable recall to CNNs without data augmentation. However, the precision of Adaboost is lower compared to the CNN results. Moreover, the F1-score illustrates the improvement of performance using CNN-based methods compared to state-of-the-art machine learning approaches. The F1-score reaches 0.704 with k-space corrupted data and achieves 0.722 with additional data augmentation. |
| 2018 | Proposed spatio-temporal CNN, real data with k-space-corrupted data augmentation proposed non-standard slice | recall | 0.642 | Motion Artifact Detection · split: test · subset=3,465 2D+time CMR sequences · augmentation=k-space-corrupted data | Deep Learning using K-space Based Data Augmentation for Automated Cardiac MR Motion Artefact DetectionSource quoteL74: We used a 10-fold stratified cross validation strategy to test all algorithms, in which each image appears once in the test set over all folds. Due to the high class imbalance, over 0.9 accuracy is achieved by most of the techniques in Table \ref{table:1}. We do not rely only on accuracy in our results due to the bias introduced by the imbalanced classes. The interesting comparison for the methods lies in the recall numbers, which quantify the capability of the methods to identify images with artefacts. The results show that the CNN-based technique is capable of identifying the presence of motion artefacts with high recall compared to other techniques. Note in particular that introducing the data with k-space corruption increases the recall number from 0.466 to 0.642. Additional data augmentation improves the recall further to 0.652. All state-of-the-art classification methods reach high accuracy, but Adaboost is capable to reach comparable recall to CNNs without data augmentation. However, the precision of Adaboost is lower compared to the CNN results. Moreover, the F1-score illustrates the improvement of performance using CNN-based methods compared to state-of-the-art machine learning approaches. The F1-score reaches 0.704 with k-space corrupted data and achieves 0.722 with additional data augmentation. |
| 2018 | Proposed spatio-temporal CNN, real data with k-space-corrupted data and additional translation augmentation proposed non-standard slice | recall | 0.652 | Motion Artifact Detection · split: test · subset=3,465 2D+time CMR sequences · augmentation=k-space-corrupted data and translation | Deep Learning using K-space Based Data Augmentation for Automated Cardiac MR Motion Artefact DetectionSource quoteL74: We used a 10-fold stratified cross validation strategy to test all algorithms, in which each image appears once in the test set over all folds. Due to the high class imbalance, over 0.9 accuracy is achieved by most of the techniques in Table \ref{table:1}. We do not rely only on accuracy in our results due to the bias introduced by the imbalanced classes. The interesting comparison for the methods lies in the recall numbers, which quantify the capability of the methods to identify images with artefacts. The results show that the CNN-based technique is capable of identifying the presence of motion artefacts with high recall compared to other techniques. Note in particular that introducing the data with k-space corruption increases the recall number from 0.466 to 0.642. Additional data augmentation improves the recall further to 0.652. All state-of-the-art classification methods reach high accuracy, but Adaboost is capable to reach comparable recall to CNNs without data augmentation. However, the precision of Adaboost is lower compared to the CNN results. Moreover, the F1-score illustrates the improvement of performance using CNN-based methods compared to state-of-the-art machine learning approaches. The F1-score reaches 0.704 with k-space corrupted data and achieves 0.722 with additional data augmentation. |