UK Biobank
83 papers · 264 extracted observations · phenotype prediction · Markdown · CSV · JSON API
Also indexed as: uk-biobank
Tasks on UK BiobankAll tasks (83)Phenotype Prediction (7)Genome Wide Association Study (4)Image Generation (4)Bmi Prediction (3)Disease Classification (3)Brain Tissue Segmentation (2)Cardiovascular Risk Prediction (2)Disease Detection (2)
TaskPhenotype Prediction (34)Genome Wide Association Study (10)Image Generation (7)Disease Classification (7)Risk Prediction (7)Time to Event Prediction (6)Dementia Risk Prediction (6)
Metricauroc (27)auc (24)mae (22)accuracy (16)concordance index c index (6)average relative efficiency re (6)error rate (6)
Regimefine-tuned (10)5-fold-cross-validation (8)age-conditioned (6)gwas (6)transfer-learning (5)linear-probe (4)
Showing 66 of 66 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2026 | PiLA (proposed physiology-guided self-supervised framework) proposed non-standard slice | AUROC | 0.7645 | Aortic Stenosis Screening · split: test · fine-tuned · input=single-beat PPG · pretraining=over 170,000 unlabeled PPG samples · waveform-length=100 points | Aortic Valve Disease Screening from PPG via Physiology-Guided Self-Supervised LearningSource quoteL109: PiLA (Ours) │ 0.7645 │ 0.7755 │ 0.7072 |
| 2026 | PiLA (proposed physiology-guided self-supervised framework) proposed non-standard slice | AUROC | 0.7756 | Aortic Regurgitation Screening · split: test · fine-tuned · input=single-beat PPG · pretraining=over 170,000 unlabeled PPG samples · waveform-length=100 points | Aortic Valve Disease Screening from PPG via Physiology-Guided Self-Supervised LearningSource quoteL122: PiLA (Ours) │ 0.7756 │ 0.7857 │ 0.7490 |
| 2025 | GNN+RV proposed | F1 | 0.716 | Dementia Risk Prediction · split: test · cohort-size=9537 · representation=randomly initialized diagnosis vectors · prediction-horizon=5 years | Predicting Dementia Risk Using Longitudinal Electronic Health Records DataSource quoteL97: 0.716 |
| 2025 | GNN+RV proposed | Sensitivity | 0.761 | Dementia Risk Prediction · split: test · cohort-size=9537 · representation=randomly initialized diagnosis vectors · prediction-horizon=5 years | Predicting Dementia Risk Using Longitudinal Electronic Health Records DataSource quoteL98: 0.761 |
| 2025 | GNN+RV proposed | Specificity | 0.673 | Dementia Risk Prediction · split: test · cohort-size=9537 · representation=randomly initialized diagnosis vectors · prediction-horizon=5 years | Predicting Dementia Risk Using Longitudinal Electronic Health Records DataSource quoteL99: 0.673 |
| 2025 | GNN+RV proposed | J | 0.434 | Dementia Risk Prediction · split: test · cohort-size=9537 · representation=randomly initialized diagnosis vectors · prediction-horizon=5 years | Predicting Dementia Risk Using Longitudinal Electronic Health Records DataSource quoteL100: 0.434 |
| 2025 | GNN+RV proposed | AUCROC | 0.777 | Dementia Risk Prediction · split: test · cohort-size=9537 · representation=randomly initialized diagnosis vectors · prediction-horizon=5 years | Predicting Dementia Risk Using Longitudinal Electronic Health Records DataSource quoteL101: 0.777 |
| 2025 | LoRA fine-tuned Mistral-7B-Instruct proposed | AUROC | 0.738 | Clinical Risk Prediction · split: test · fine-tuned · params=7B · backbone=Mistral-7B-Instruct · fine-tuning=LoRA · prediction-horizon=10-year | From Structured Data to Clinical Notes: Robust Clinical Decision Support with Fine-Tuned LLMsSource quoteL78: Figure 2 shows the performance using only the base risk factors as inputs. Both the LLM-based model and LGBM achieved state-of-the-art performance for CVD risk prediction, with an area under the receiver operating characteristic curve (AUROC) of 0.738. |
| 2025 | SLSE (VAE-encoder spirogram embedding fused with demographic information; CatBoost classifier) proposed non-standard slice | AUROC | 0.7501 | Disease Detection · split: test · subset=selected cohort | Artificial Intelligence-Enabled Spirometry for Early Detection of Right Heart FailureSource quoteL137: We choose area under the receiver operating characteristic curve (AUROC) as the indicator to evaluate model performance. For our task, AUROC is suitable for evaluating the performance of the model in a dataset with an imbalance of positive and negative samples. As shown in the Table \ref{tab:Demographic}, the number of healthy people in the dataset is much higher than that of patients with RHF, which is also in line with the actual clinical situation. Our model finally achieved AUROC=0.7501 on the test set, which shows that the model has good performance in predicting patients with RHF. |
| 2025 | SLSE (VAE-encoder spirogram embedding fused with demographic information; CatBoost classifier) proposed non-standard slice | AUROC | 0.8194 | Disease Detection · split: test · subset=CKD | Artificial Intelligence-Enabled Spirometry for Early Detection of Right Heart FailureSource quoteL142: Ultimately, we find that the model achieves better AUROC performance on VHD, CKD, CHD, diabetes, and smoking subsets than when tested on the entire test set (Figure \ref{fig:subgroup}a), particularly achieving an AUROC=0.8194 on the CKD subset, and an AUROC=0.8413 on the VHD subset. This demonstrates the potential of our model for predicting RHF in CKD and VHD patients. For a excellent AUROC performance on this two subsets, it is possibly because CKD and VHD will increase circulatory load, which significantly exacerbates the symptoms of RHF when combined with it. As for the differences in subgroup distribution, Figure \ref{fig:subgroup}c CKD group shows that the RHF prediction probability distribution for patients with CKD is significantly broader than that for those without CKD, and the median prediction probability is also larger; the same applies to VHD subgroup (Figure \ref{fig:subgroup}c VHD group). The p-values indicate that the model has strong classification ability for the CKD subgroup but weaker classification ability for the VHD subgroup, suggesting that further validation with more VHD patient samples may be needed. |
| 2025 | SLSE (VAE-encoder spirogram embedding fused with demographic information; CatBoost classifier) proposed non-standard slice | AUROC | 0.8413 | Disease Detection · split: test · subset=VHD | Artificial Intelligence-Enabled Spirometry for Early Detection of Right Heart FailureSource quoteL142: Ultimately, we find that the model achieves better AUROC performance on VHD, CKD, CHD, diabetes, and smoking subsets than when tested on the entire test set (Figure \ref{fig:subgroup}a), particularly achieving an AUROC=0.8194 on the CKD subset, and an AUROC=0.8413 on the VHD subset. This demonstrates the potential of our model for predicting RHF in CKD and VHD patients. For a excellent AUROC performance on this two subsets, it is possibly because CKD and VHD will increase circulatory load, which significantly exacerbates the symptoms of RHF when combined with it. As for the differences in subgroup distribution, Figure \ref{fig:subgroup}c CKD group shows that the RHF prediction probability distribution for patients with CKD is significantly broader than that for those without CKD, and the median prediction probability is also larger; the same applies to VHD subgroup (Figure \ref{fig:subgroup}c VHD group). The p-values indicate that the model has strong classification ability for the CKD subgroup but weaker classification ability for the VHD subgroup, suggesting that further validation with more VHD patient samples may be needed. |
| 2024 | PSPS proposed | Significant genetic variants | 108 variants | Vqtl Discovery · split: test · fdr=<0.05 · trait=total-body DXA-BMD · labeled-samples=36971 · unlabeled-samples=319548 | Task-Agnostic Machine-Learning-Assisted InferenceSource quoteL348: No genetic variants reached statistical significance under the classical method with only labeled data. \PSPS~identified 108 significant variants with FDR \(< 0.05\) spanning 5 independent loci, showcasing the superior statistical power of \PSPS~(\cref{fig:vqtl.man} and \cref{table:vQTL}). Notably, these significant vQTL cannot be identified by linear regression \citep{miao2024valid}, indicating the different genetic mechanisms controlling outcome levels and variability for DXA-BMD. |
| 2024 | PSPS proposed | Independent loci spanning significant vQTLs | 5 loci | Vqtl Discovery · split: test · fdr=<0.05 · trait=total-body DXA-BMD · labeled-samples=36971 · unlabeled-samples=319548 | Task-Agnostic Machine-Learning-Assisted InferenceSource quoteL348: No genetic variants reached statistical significance under the classical method with only labeled data. \PSPS~identified 108 significant variants with FDR \(< 0.05\) spanning 5 independent loci, showcasing the superior statistical power of \PSPS~(\cref{fig:vqtl.man} and \cref{table:vQTL}). Notably, these significant vQTL cannot be identified by linear regression \citep{miao2024valid}, indicating the different genetic mechanisms controlling outcome levels and variability for DXA-BMD. |
| 2024 | Med-Gemini-Polygenic proposed non-standard slice | AUC | 82.5 | Disease Risk Prediction · split: test · subset=balanced: 200 cases and 200 controls | Advancing Multimodal Medical Capabilities of GeminiSource quoteL1154: Coronary artery disease │ AUC │ 82.5 │ N/A │ 78.5 │ \multirow{14}{*}{\begin{tabular}[c]{@{}c@{}}Ensemble of PRSs and Demographics} |
| 2024 | KRR-FP16 proposed non-standard slice | Pearson correlation | 0.8652 | Phenotype Prediction · split: test · phenotype=Allergic Rhinitis · precision=FP16 | Toward Capturing Genetic Epistasis From Multivariate Genome-Wide Association Studies Using Mixed-Precision Kernel Ridge RegressionSource quoteL406: \texttt{Allergic Rhinitis} │ 0.2008 │ 0.8652 │ N/A |
| 2024 | KRR-FP16 proposed non-standard slice | Pearson correlation | 0.8071 | Phenotype Prediction · split: test · phenotype=Hypertension · precision=FP16 | Toward Capturing Genetic Epistasis From Multivariate Genome-Wide Association Studies Using Mixed-Precision Kernel Ridge RegressionSource quoteL403: \texttt{Hypertension} │ 0.2983 │ 0.8071 │ N/A |
| 2024 | IdenBAT proposed non-standard slice | PAD (↓), All | 3.52 | Brain Age Transformation · split: test · slice=97th axial · subset=longitudinal pairs; age gap >2 years · target-ages=48–80 · input-dimension=2D | IdenBAT: Disentangled representation learning for identity-preserved brain age transformationSource quoteL217: IdenBAT (Ours) │ 26.314 │ 0.924 │ 0.0026 │ 3.52 │ 3.27 │ 3.05 │ 3.56 │ 3.14 │ 4.72 |
| 2024 | IdenBAT proposed non-standard slice | PAD (↓), All | 4.68 | Brain Age Transformation · split: test · subset=longitudinal pairs; age gap >2 years · target-ages=48–80 · input-dimension=3D | IdenBAT: Disentangled representation learning for identity-preserved brain age transformationSource quoteL219: IdenBAT (Ours) │ 29.653 │ 0.958 │ 0.0020 │ 4.68 │ 5.24 │ 3.47 │ 4.26 │ 5.27 │ 5.35 |
| 2024 | IdenBAT proposed non-standard slice | SSIM (↑) | 0.958 | Brain Age Transformation · split: test · subset=longitudinal pairs; age gap >2 years · input-dimension=3D | IdenBAT: Disentangled representation learning for identity-preserved brain age transformationSource quoteL219: IdenBAT (Ours) │ 29.653 │ 0.958 │ 0.0020 │ 4.68 │ 5.24 │ 3.47 │ 4.26 │ 5.27 │ 5.35 |
| 2024 | Net1D + Dist Loss (paper's “Ours”) proposed | Pearson correlation coefficient | 0.474 | Vascular Age Estimation · split: test · held-out-fraction=40% | Deep Imbalanced Regression to Estimate Vascular Age from PPG Data: a Novel Digital Biomarker for Cardiovascular HealthSource quoteL154: + Ours │ \textbf{\textcolor{red}{0.474}} |
| 2024 | Net1D + Dist Loss (paper's “Ours”) proposed non-standard slice | MAE | 9.495 | Vascular Age Estimation · split: test · few-shot · subset=labels with occurrence probability below one-third of the maximum | Deep Imbalanced Regression to Estimate Vascular Age from PPG Data: a Novel Digital Biomarker for Cardiovascular HealthSource quoteL171: + Ours │ \textbf{\textcolor{red}{0.686}} │ \textbf{\textcolor{red}{9.495}} │ \textbf{\textcolor{red}{12.029}} │ \textbf{\textcolor{red}{0.158}} │ \textbf{\textcolor{red}{4.963}} │ 6.851 │ \textbf{\textcolor{red}{59.846}} │ \textbf{\textcolor{red}{75.815}} |
| 2024 | BrainLM proposed | R2 | 0.464 | Masked Patch Prediction · split: test | BrainLM: A foundation model for brain activity recordingsSource quoteL70: On the UKB test data, BrainLM achieved an average R2 score of 0.464 on the prediction of masked patches, indicating strong generalization on unseen recordings from the same distribution. Critically, BrainLM also generalized well to the HCP dataset, achieving a R2 score of 0.278. Despite differences in cohort and acquisition details, BrainLM could effectively model brain dynamics in this entirely new distribution. Figure 3 shows sample reconstructions on both UKB and HCP recordings. We found that the model generalization scales with data size and model size, showing strong model scaling (see Figure 4). Overall, these results demonstrate BrainLM’s ability to learn robust representations of fMRI recordings that generalize across datasets. This highlights the advantages of large-scale pretraining for learning widely applicable models of brain activity. |
| 2024 | X-Diffusion (1-slice input) proposed | Test 3D PSNR | 22.42 | 3D Reconstruction · split: test · input-slices=1 | X-Diffusion: Generating Detailed 3D MRI Volumes From a Single Image Using Cross-Sectional Diffusion ModelsSource quoteL131: X-Diffusion (ours) │ 23.10 │ 22.42 │ 25.20 │ 23.04 │ 29.43 │ 25.26 │ 31.25 │ 26.85 │ 33.27 │ 27.44 │ 35.48 │ 29.01 |
| 2023 | DisPred proposed | AUC | 0.6692 | Disease Risk Prediction · split: test · phenotype=Alzheimer's disease family-history proxy · population=admixed | Improving genetic risk prediction across diverse population by disentangling ancestry representationsSource quoteL91: South Asians (SAS), East Asians (EAS), Americans (AMR), Africans (AFR), and Europeans (EUR), and an admixed group composed of individuals not passing cut-off in any ancestry. Since UKB primarily comprises European participants, we set the threshold low to obtain enough admixed and non-EUR participants for our analysis. In both datasets, EUR ancestry individuals correspond to the largest proportion (48% for the ADSP and 92% for the UKB). Admixed individuals are the second largest group (44% for the ADSP and 6% for the UKB). For both cohorts, we consider four test datasets: i) all test participants, ii) European participants, iii) admixed participants, and iv) non-European participants, primarily AFR for the ADSP and primarily SAS for the UKB. Panel B presents the result for all the test participants, and the proposed DisPred leads to the best result for ADSP and the joint best result for UKB (Lasso-EUR being marginally better than DisPred). The analysis restricted to European participants is shown in panel C. In this case, Lasso-EUR achieves the best result, and the proposed method produces the second-best result for both datasets. In admixed individuals, DisPred produces the best result for both UKB and ADSP (Panel D). In UKB, the performance on admixed individuals (best AUC: 0.6692 by DisPred) is equivalent to the one |
| 2023 | proposed pairwise pseudolikelihood proposed non-standard slice | number of SNPs significantly associated with increased UBC risk | 11 SNPs | Risk Association Analysis · split: test · subset=31 previously associated SNPs · disease=urinary bladder cancer · significance-threshold=BH-adjusted p < 0.05 | Unlocking Retrospective Prevalent Information in EHRs -- a Pairwise Pseudolikelihood ApproachSource quoteL30: Employing a Cox model \citep{cox1972regression}, we observe higher statistical power with the proposed approach compared to the standard partial-likelihood (PL) estimator, adjusted for left truncation and excluding prevalent observations. Of 31 tested SNPs, 11 were significantly associated with increased UBC risk using the proposed approach, compared to six SNPs detected by the standard PL estimator. The Benjamini-Hochberg (BH) \citep{benjamini1995controlling} procedure for multiple-testing was used, with significance threshold set at 0.05. |
| 2023 | Genetic InfoMax (GIM) proposed | Estimated MI | 1.3681 | Mutual Information Estimation · split: test · estimator=JSE · representation=first 10 principal components | Genetic InfoMax: Exploring Mutual Information Maximization in High-Dimensional Imaging Genetics StudiesSource quoteL186: 40 │ 15 │ 1.3681 │ 0.3723~\textpm~0.0305 |
| 2023 | Latent Diffusion Models proposed | FID | 2.1986 | Image Generation · split: test · resolution=160×224 | Generative AI for Medical Imaging: extending the MONAI FrameworkSource quoteL62: UK Biobank │ 2D Brain Slice MRI │ 160 × 224 │ 2.1986 │ 0.5368 │ 0.9876 |
| 2023 | Bernoulli-sigmoid model with uniform unobservables (α=1) and prevalence constraint p(Y=1)=0.02 proposed | AUC | 0.63 | Risk Prediction · split: test · alpha=1 · outcome=breast cancer · population=tested (T=1) · prevalence-constraint=p(Y=1)=0.02 | Domain constraints improve risk prediction when outcome data is missingSource quoteL415: We also consider a baseline model which treats the untested group as negative; this is equivalent to predicting p(T_i=1, Y_i=1|X_i), an approach used in prior selective labels work \citep{shen2021artificial, ko2020detection, rastogi2023learn}. We find that, though this baseline no longer learns an implausible age trend, it underperforms our model in terms of AUC (AUC is 0.60 on the tested population vs. 0.63 for our model; AUC is 0.60 on the untested population vs. 0.63 for our model) and quintile ratio (quintile ratio on the tested population is 2.4 vs. 3.3 for our model; quintile ratio for both models is 2.5 on the untested population). This baseline is a special case of our model with the prevalence constraint set to p(Y=1|T=0) = 0, an implausibly low prevalence constraint. In light of this, it makes sense that this baseline learns a more plausible age trend, but underperforms our model overall. |
| 2023 | Bernoulli-sigmoid model with uniform unobservables (α=1) and prevalence constraint p(Y=1)=0.02 proposed | AUC | 0.63 | Risk Prediction · split: test · alpha=1 · outcome=breast cancer · population=untested (T=0) · prevalence-constraint=p(Y=1)=0.02 | Domain constraints improve risk prediction when outcome data is missingSource quoteL415: We also consider a baseline model which treats the untested group as negative; this is equivalent to predicting p(T_i=1, Y_i=1|X_i), an approach used in prior selective labels work \citep{shen2021artificial, ko2020detection, rastogi2023learn}. We find that, though this baseline no longer learns an implausible age trend, it underperforms our model in terms of AUC (AUC is 0.60 on the tested population vs. 0.63 for our model; AUC is 0.60 on the untested population vs. 0.63 for our model) and quintile ratio (quintile ratio on the tested population is 2.4 vs. 3.3 for our model; quintile ratio for both models is 2.5 on the untested population). This baseline is a special case of our model with the prevalence constraint set to p(Y=1|T=0) = 0, an implausibly low prevalence constraint. In light of this, it makes sense that this baseline learns a more plausible age trend, but underperforms our model overall. |
| 2023 | Bernoulli-sigmoid model with uniform unobservables (α=1) and prevalence constraint p(Y=1)=0.02 proposed non-standard slice | quintile ratio | 3.3 | Risk Prediction · split: test · alpha=1 · outcome=breast cancer · population=tested (T=1) · prevalence-constraint=p(Y=1)=0.02 | Domain constraints improve risk prediction when outcome data is missingSource quoteL415: We also consider a baseline model which treats the untested group as negative; this is equivalent to predicting p(T_i=1, Y_i=1|X_i), an approach used in prior selective labels work \citep{shen2021artificial, ko2020detection, rastogi2023learn}. We find that, though this baseline no longer learns an implausible age trend, it underperforms our model in terms of AUC (AUC is 0.60 on the tested population vs. 0.63 for our model; AUC is 0.60 on the untested population vs. 0.63 for our model) and quintile ratio (quintile ratio on the tested population is 2.4 vs. 3.3 for our model; quintile ratio for both models is 2.5 on the untested population). This baseline is a special case of our model with the prevalence constraint set to p(Y=1|T=0) = 0, an implausibly low prevalence constraint. In light of this, it makes sense that this baseline learns a more plausible age trend, but underperforms our model overall. |
| 2022 | Proposed conditional generative model proposed | KL divergence | 0.0248 | Synthetic Data Generation · split: test · age-conditioned · clinical-measure=LVM | Generative Modelling of the Ageing Heart with Cross-Sectional Imaging and Clinical DataSource quoteL135: 0.0248 |
| 2022 | Proposed conditional generative model proposed | Wasserstein distance | 15.2829 | Synthetic Data Generation · split: test · age-conditioned · clinical-measure=LVM | Generative Modelling of the Ageing Heart with Cross-Sectional Imaging and Clinical DataSource quoteL136: 15.2829 |
| 2022 | Proposed conditional generative model proposed | KL divergence | 0.0334 | Synthetic Data Generation · split: test · age-conditioned · clinical-measure=LVEDV | Generative Modelling of the Ageing Heart with Cross-Sectional Imaging and Clinical DataSource quoteL137: 0.0334 |
| 2022 | Causal Shape Model, f_X(z_X^i,u_X;\cdot) proposed | Median VED | 0.8900 mm | 3D Shape Reconstruction · split: test · latent-dimension=16 | Deep Structural Causal Shape ModelsSource quoteL380: 16 │ 0.9006 ± 0.10 │ 0.8900 │ 2.0421 |
| 2022 | Causal Shape Model, f_X(z_X^i,u_X;\cdot) proposed | Chamfer Distance | 2.0421 mm | 3D Shape Reconstruction · split: test · latent-dimension=16 | Deep Structural Causal Shape ModelsSource quoteL380: 16 │ 0.9006 ± 0.10 │ 0.8900 │ 2.0421 |
| 2022 | DART (Deep Approximation of Retinal Traits) proposed | Pearson r | 0.9572 | Fractal Dimension Estimation · split: test · degradation=none | Robust and efficient computation of retinal fractal dimension through deep approximationSource quoteL83: None │ 0.9160 │ 0.9572 (0.0000) │ 0.9561 (0.0000) │ y=0.01 + 1.00x |
| 2022 | DART (Deep Approximation of Retinal Traits) proposed | Pearson r | 0.8817 | Fractal Dimension Estimation · split: test · degradation=severity-5 | Robust and efficient computation of retinal fractal dimension through deep approximationSource quoteL88: Severity 5 │ 0.7773 │ 0.8817 (0.0000) │ 0.8840 (0.0000) │ y=0.02 + 0.99x |
| 2022 | DistGP-Seg proposed | DICE WM | 0.867 | Brain Tissue Segmentation · split: test · input=FLAIR · cohort=normal subjects · architecture=three-hidden-layer | Distributional Gaussian Processes Layers for Out-of-Distribution DetectionSource quoteL841: DistGP-Seg (ours) │ 3 │ 0.829 │ 0.823 │ 0.867 |
| 2021 | VR-Net (R-L2-6×1) proposed non-standard slice | Dice (LV) | 0.948 | Image Registration · split: test · slices=basal, mid-ventricular, apical · subset=100 test subjects · structure=LV | Learning a Model-Driven Variational Network for Deformable Image RegistrationSource quoteL326: In Table \ref{tab:ukbb} and \ref{tab:acdc}, we show the quantitative results obtained by using different methods on UK Biobank and ACDC. In the tables, one can see that VR-Net outperforms iterative methods and data-driven methods on both datasets for almost all anatomical structures. On UK Biobank, RC-Net achieves the best result on RV in terms of both Dice and HD of 0.005 and 0.42mm respectively compared to that obtained by our best configuration of (R-\rm{L}_2-6×1). However, in terms of Dice, VR-Net achieves 0.948 on LV and 0.764 on Myo, outperforming 3×RC-Net by 0.004 and by 0.028, respectively. In terms of HD for LV and Myo, our VR-Net improves 3×RC-Net from 4.28mm to 3.90mm and from 7.39mm to 6.49mm, respectively. On average, the proposed VR-Net achieves a better Dice and HD score than 3×RC-Net, making our VR-Net the best method on this dataset. |
| 2021 | 3D-StyleGAN (2mm-fd64) proposed non-standard slice | FID-Sag | 106.9 | Image Generation · split: test · resolution=2mm · feature-dim=64 | 3D-StyleGAN: A Style-Based Generative Adversarial Network for Generative Modeling of Three-Dimensional Medical ImagesSource quoteL131: 2mm-fd64 │ 4497 (898.53) │ 0.93 (0.12) │ 106.9 │ 71.3 │ 90.2 |
| 2021 | 3D-StyleGAN (2mm-fd64) proposed non-standard slice | FID-Ax | 71.3 | Image Generation · split: test · resolution=2mm · feature-dim=64 | 3D-StyleGAN: A Style-Based Generative Adversarial Network for Generative Modeling of Three-Dimensional Medical ImagesSource quoteL131: 2mm-fd64 │ 4497 (898.53) │ 0.93 (0.12) │ 106.9 │ 71.3 │ 90.2 |
| 2021 | 3D-StyleGAN (2mm-fd96) proposed non-standard slice | FID-Cor | 88.5 | Image Generation · split: test · resolution=2mm · feature-dim=96 | 3D-StyleGAN: A Style-Based Generative Adversarial Network for Generative Modeling of Three-Dimensional Medical ImagesSource quoteL132: 2mm-fd96 │ 4475 (539.38) │ 0.96 (0.04) │ 138.3 │ 83.2 │ 88.5 |
| 2021 | DistGP-Seg proposed non-standard slice | Dice (CSF) | 0.829 | Brain Tissue Segmentation · split: test · subset=healthy subjects, bottom 10th percentile for white-matter hypointensities · modality=FLAIR · split-protocol=equal train/test split | Distributional Gaussian Process Layers for Outlier Detection in Image SegmentationSource quoteL254: DistGP-Seg (ours) │ 3 │ 0.829 │ 0.823 │ 0.867 |
| 2021 | DistGP-Seg proposed non-standard slice | Dice (GM) | 0.823 | Brain Tissue Segmentation · split: test · subset=healthy subjects, bottom 10th percentile for white-matter hypointensities · modality=FLAIR · split-protocol=equal train/test split | Distributional Gaussian Process Layers for Outlier Detection in Image SegmentationSource quoteL254: DistGP-Seg (ours) │ 3 │ 0.829 │ 0.823 │ 0.867 |
| 2021 | DistGP-Seg proposed non-standard slice | Dice (WM) | 0.867 | Brain Tissue Segmentation · split: test · subset=healthy subjects, bottom 10th percentile for white-matter hypointensities · modality=FLAIR · split-protocol=equal train/test split | Distributional Gaussian Process Layers for Outlier Detection in Image SegmentationSource quoteL254: DistGP-Seg (ours) │ 3 │ 0.829 │ 0.823 │ 0.867 |
| 2021 | ContIG (PGS; H1) proposed | ROC-AUC | 72.72 | Cardiovascular Risk Prediction · split: test · fine-tuned | ContIG: Self-supervised Multimodal Contrastive Learning for Medical Imaging with GeneticsSource quoteL209: ContIG (PGS) │ H1 │ 85.93 │ 93.31 │ 78.47 │ 3.176 │ 72.72 |
| 2020 | Proposed deep generative model-based quality control proposed non-standard slice | Pearson correlation coefficient r | 0.96 | Segmentation Quality Estimation · split: test · n=500 · subset=attacked segmentations · perturbation=white noise at varying variance levels | Deep Generative Model-Based Quality Control for Cardiac MRI SegmentationSource quoteL99: Quality control performance is assessed in terms of Dice metric prediction accuracy. Pearson correlation coefficient r and mean absolute error (MAE) between predicted Dice and real Dice are calculated. Table 1 compares the quantitative performance of the methods and Fig.\ref{figure3} visualises the predictions. On UK Biobank dataset, the hand-crafted feature method performed the worst. The proposed method achieved a similar performance (r=0.96, MAE=0.07) as the CNN regression method (r=0.97, MAE=0.06). However, on ACDC dataset, the proposed method (r=0.97, MAE=0.03) outperformed the CNN regression method (r=0.97, MAE=0.17) with a smaller MAE. As shown in Fig. \ref{figure3}, on ACDC dataset, the prediction of the proposed method aligns well with the identity line, whereas the CNN regression method clearly deviates from the line, even though the r coefficient is still high. |
| 2020 | Proposed deep generative model-based quality control proposed non-standard slice | Mean absolute error (MAE) | 0.07 | Segmentation Quality Estimation · split: test · n=500 · subset=attacked segmentations · perturbation=white noise at varying variance levels | Deep Generative Model-Based Quality Control for Cardiac MRI SegmentationSource quoteL99: Quality control performance is assessed in terms of Dice metric prediction accuracy. Pearson correlation coefficient r and mean absolute error (MAE) between predicted Dice and real Dice are calculated. Table 1 compares the quantitative performance of the methods and Fig.\ref{figure3} visualises the predictions. On UK Biobank dataset, the hand-crafted feature method performed the worst. The proposed method achieved a similar performance (r=0.96, MAE=0.07) as the CNN regression method (r=0.97, MAE=0.06). However, on ACDC dataset, the proposed method (r=0.97, MAE=0.03) outperformed the CNN regression method (r=0.97, MAE=0.17) with a smaller MAE. As shown in Fig. \ref{figure3}, on ACDC dataset, the prediction of the proposed method aligns well with the identity line, whereas the CNN regression method clearly deviates from the line, even though the r coefficient is still high. |
| 2020 | ICAM proposed | Accuracy | 0.943 | Age Classification · split: test · classes=ages 45–60 vs 70–80 | ICAM: Interpretable Classification via Disentangled Representations and Feature Attribution MappingSource quoteL177: We achieved 0.943 accuracy on the test dataset with ICAM on age classification, but cannot compare to VA-GAN, as it cannot perform class prediction. We compare the feature attribution maps and translated images against VA-GAN (Fig.~\ref{fig:biobank_comparison}, and Fig.~\ref{fig:biobank_very_old_young}). While we do not have ground truth maps for a comparison in Biobank, it is commonly described within the neuroscience domain that hippocampal atrophy \cite{o2016cognitive}, decrease in cortical thickness, and the enlargement of the ventricles are often observed with ageing, and are indicative of neurodegeneration \cite{guo2017mri, pacheco2015greater}. We looked for this phenotypic variation in our qualitative analysis. For ICAM we plot variance, and mean FA maps (computed through multiple sampling of the attribute latent space in test time); for VA-GAN we show only FA as it can only generate a single deterministic output. We found that VA-GAN was able to detect some variation in the ventricles and cortex, but that ICAM was able to detect more variability in the ventricles (blue arrows), cortex (green arrows), and in the hippocampus (purple arrow). Interestingly, the variance map detects higher variability in the ventricles and the cortex, which may reflect heterogeneity in the ageing process. We also note that while ICAM is able to change the shape of different brain regions in translation (e.g. shrinking the ventricles, or enlarging the cortical folds), VA-GAN is only able to change the pixel intensities, and does not appear to change the shape. This is a significant advantage for ICAM compared to previous methods, as shape is an important phenotype in many other medical datasets \cite{garcia2018dynamic, kapellou2006abnormal}, and thus is likely to generalise well. |
| 2020 | Best single-patch network proposed | MAE | 2.46 years | Brain Age Estimation · split: test · resolution=64x64 · input=3D T1-weighted MRI · backbone=3D ResNet · selection=best of 27 patch models · patch_size=64×64×64 voxels | Patch-Based Brain Age Estimation from MR ImagesSource quoteL44: Best single-patch network │ 2.46 │ 0.80 |
| 2020 | All-patch linear-regression ensemble proposed | MAE | 2.13 years | Brain Age Estimation · split: test · input=3D T1-weighted MRI · ensemble=all-patch linear regression · bias_correction=uncorrected | Patch-Based Brain Age Estimation from MR ImagesSource quoteL100: The use of linear regression works better. Specifically, we achieve a MAE of 2.13 years when all the single-patch models are used. Furthermore, when we use only the models of the patches with the most important information for the age of the brain, we achieve a MAE of 2.16 years. Regarding R^2 score, it is 0.85 in both cases. In this case, bias correction is applied as well and we achieve a MAE of 1.96 years, and an R^2 score of 0.87. The scatter plots of the real over predicted ages, before and after bias correction is applied, are shown in Figure \ref{fig4}. |
| 2020 | All-patch linear-regression ensemble proposed | MAE | 1.96 years | Brain Age Estimation · split: test · input=3D T1-weighted MRI · ensemble=all-patch linear regression · bias_correction=corrected | Patch-Based Brain Age Estimation from MR ImagesSource quoteL100: The use of linear regression works better. Specifically, we achieve a MAE of 2.13 years when all the single-patch models are used. Furthermore, when we use only the models of the patches with the most important information for the age of the brain, we achieve a MAE of 2.16 years. Regarding R^2 score, it is 0.85 in both cases. In this case, bias correction is applied as well and we achieve a MAE of 1.96 years, and an R^2 score of 0.87. The scatter plots of the real over predicted ages, before and after bias correction is applied, are shown in Figure \ref{fig4}. |
| 2020 | All-patch linear-regression ensemble proposed | R^2 score | 0.85 | Brain Age Estimation · split: test · input=3D T1-weighted MRI · ensemble=all-patch linear regression · bias_correction=uncorrected | Patch-Based Brain Age Estimation from MR ImagesSource quoteL100: The use of linear regression works better. Specifically, we achieve a MAE of 2.13 years when all the single-patch models are used. Furthermore, when we use only the models of the patches with the most important information for the age of the brain, we achieve a MAE of 2.16 years. Regarding R^2 score, it is 0.85 in both cases. In this case, bias correction is applied as well and we achieve a MAE of 1.96 years, and an R^2 score of 0.87. The scatter plots of the real over predicted ages, before and after bias correction is applied, are shown in Figure \ref{fig4}. |
| 2020 | All-patch linear-regression ensemble proposed | R^2 score | 0.87 | Brain Age Estimation · split: test · input=3D T1-weighted MRI · ensemble=all-patch linear regression · bias_correction=corrected | Patch-Based Brain Age Estimation from MR ImagesSource quoteL100: The use of linear regression works better. Specifically, we achieve a MAE of 2.13 years when all the single-patch models are used. Furthermore, when we use only the models of the patches with the most important information for the age of the brain, we achieve a MAE of 2.16 years. Regarding R^2 score, it is 0.85 in both cases. In this case, bias correction is applied as well and we achieve a MAE of 1.96 years, and an R^2 score of 0.87. The scatter plots of the real over predicted ages, before and after bias correction is applied, are shown in Figure \ref{fig4}. |
| 2019 | Monotone rate-of-aging model proposed | Mean correlation between true and reconstructed feature values | 0.88 | Feature Reconstruction · split: test · model=monotone rate-of-aging model | Inferring Multidimensional Rates of Aging from Cross-Sectional DataSource quoteL155: xt against the reconstructed posterior mean of xt given (ˆr,ˆb). On a held-out test set, reconstruction was largely accurate, with a mean correlation between true and reconstructed feature values of 0.88 ( Figure G.6). The other baselines performed similarly: PCA, mcPCA, and cPCA did slightly worse, with mean correlations of 0.86, |
| 2019 | PFGT (optimal tuning parameter selected per SNP) proposed | association p-value for rs6663450 | 5.15E-07 | Genome Wide Association Study · split: test · tuning=optimal parameter selected per SNP · phenotype=whole-brain FA | A Powerful Global Test Statistic for Functional Statistical InferenceSource quoteL295: 5.15E-07 |
| 2019 | PFGT (optimal tuning parameter selected per SNP) proposed | association p-value for rs11158764 | 5.37E-07 | Genome Wide Association Study · split: test · tuning=optimal parameter selected per SNP · phenotype=whole-brain FA | A Powerful Global Test Statistic for Functional Statistical InferenceSource quoteL298: 5.37E-07 |
| 2018 | Proposed CNN, Experiment 2 (reverse-testing/RCA-derived quality supervision) proposed | Binary classification accuracy | 0.906 | Segmentation Quality Prediction · split: test · modality=CMR · experiment=2 · segmentation=whole-heart · quality-supervision=reverse-testing/RCA-derived | Real-Time Prediction of Segmentation QualitySource quoteL83: \multicolumn{1}{c}{} │ \multicolumn{1}{|c}{TPR 0.975} │ \multicolumn{1}{c}{FPR 0.060} │ \multicolumn{1}{c|}{Acc. 0.965} │ \multicolumn{1}{c}{TPR 0.879} │ \multicolumn{1}{c}{FPR 0.000} │ \multicolumn{1}{c|}{Acc. 0.906} |
| 2018 | Proposed spatio-temporal CNN, real data only without data augmentation proposed non-standard slice | recall | 0.466 | Motion Artifact Detection · split: test · subset=3,465 2D+time CMR sequences · augmentation=none | Deep Learning using K-space Based Data Augmentation for Automated Cardiac MR Motion Artefact DetectionSource quoteL74: We used a 10-fold stratified cross validation strategy to test all algorithms, in which each image appears once in the test set over all folds. Due to the high class imbalance, over 0.9 accuracy is achieved by most of the techniques in Table \ref{table:1}. We do not rely only on accuracy in our results due to the bias introduced by the imbalanced classes. The interesting comparison for the methods lies in the recall numbers, which quantify the capability of the methods to identify images with artefacts. The results show that the CNN-based technique is capable of identifying the presence of motion artefacts with high recall compared to other techniques. Note in particular that introducing the data with k-space corruption increases the recall number from 0.466 to 0.642. Additional data augmentation improves the recall further to 0.652. All state-of-the-art classification methods reach high accuracy, but Adaboost is capable to reach comparable recall to CNNs without data augmentation. However, the precision of Adaboost is lower compared to the CNN results. Moreover, the F1-score illustrates the improvement of performance using CNN-based methods compared to state-of-the-art machine learning approaches. The F1-score reaches 0.704 with k-space corrupted data and achieves 0.722 with additional data augmentation. |
| 2018 | Proposed spatio-temporal CNN, real data with k-space-corrupted data augmentation proposed non-standard slice | recall | 0.642 | Motion Artifact Detection · split: test · subset=3,465 2D+time CMR sequences · augmentation=k-space-corrupted data | Deep Learning using K-space Based Data Augmentation for Automated Cardiac MR Motion Artefact DetectionSource quoteL74: We used a 10-fold stratified cross validation strategy to test all algorithms, in which each image appears once in the test set over all folds. Due to the high class imbalance, over 0.9 accuracy is achieved by most of the techniques in Table \ref{table:1}. We do not rely only on accuracy in our results due to the bias introduced by the imbalanced classes. The interesting comparison for the methods lies in the recall numbers, which quantify the capability of the methods to identify images with artefacts. The results show that the CNN-based technique is capable of identifying the presence of motion artefacts with high recall compared to other techniques. Note in particular that introducing the data with k-space corruption increases the recall number from 0.466 to 0.642. Additional data augmentation improves the recall further to 0.652. All state-of-the-art classification methods reach high accuracy, but Adaboost is capable to reach comparable recall to CNNs without data augmentation. However, the precision of Adaboost is lower compared to the CNN results. Moreover, the F1-score illustrates the improvement of performance using CNN-based methods compared to state-of-the-art machine learning approaches. The F1-score reaches 0.704 with k-space corrupted data and achieves 0.722 with additional data augmentation. |
| 2018 | Proposed spatio-temporal CNN, real data with k-space-corrupted data and additional translation augmentation proposed non-standard slice | recall | 0.652 | Motion Artifact Detection · split: test · subset=3,465 2D+time CMR sequences · augmentation=k-space-corrupted data and translation | Deep Learning using K-space Based Data Augmentation for Automated Cardiac MR Motion Artefact DetectionSource quoteL74: We used a 10-fold stratified cross validation strategy to test all algorithms, in which each image appears once in the test set over all folds. Due to the high class imbalance, over 0.9 accuracy is achieved by most of the techniques in Table \ref{table:1}. We do not rely only on accuracy in our results due to the bias introduced by the imbalanced classes. The interesting comparison for the methods lies in the recall numbers, which quantify the capability of the methods to identify images with artefacts. The results show that the CNN-based technique is capable of identifying the presence of motion artefacts with high recall compared to other techniques. Note in particular that introducing the data with k-space corruption increases the recall number from 0.466 to 0.642. Additional data augmentation improves the recall further to 0.652. All state-of-the-art classification methods reach high accuracy, but Adaboost is capable to reach comparable recall to CNNs without data augmentation. However, the precision of Adaboost is lower compared to the CNN results. Moreover, the F1-score illustrates the improvement of performance using CNN-based methods compared to state-of-the-art machine learning approaches. The F1-score reaches 0.704 with k-space corrupted data and achieves 0.722 with additional data augmentation. |
| 2018 | Proposed spatio-temporal CNN, real data with k-space-corrupted data augmentation proposed non-standard slice | F1-score | 0.704 | Motion Artifact Detection · split: test · subset=3,465 2D+time CMR sequences · augmentation=k-space-corrupted data | Deep Learning using K-space Based Data Augmentation for Automated Cardiac MR Motion Artefact DetectionSource quoteL74: We used a 10-fold stratified cross validation strategy to test all algorithms, in which each image appears once in the test set over all folds. Due to the high class imbalance, over 0.9 accuracy is achieved by most of the techniques in Table \ref{table:1}. We do not rely only on accuracy in our results due to the bias introduced by the imbalanced classes. The interesting comparison for the methods lies in the recall numbers, which quantify the capability of the methods to identify images with artefacts. The results show that the CNN-based technique is capable of identifying the presence of motion artefacts with high recall compared to other techniques. Note in particular that introducing the data with k-space corruption increases the recall number from 0.466 to 0.642. Additional data augmentation improves the recall further to 0.652. All state-of-the-art classification methods reach high accuracy, but Adaboost is capable to reach comparable recall to CNNs without data augmentation. However, the precision of Adaboost is lower compared to the CNN results. Moreover, the F1-score illustrates the improvement of performance using CNN-based methods compared to state-of-the-art machine learning approaches. The F1-score reaches 0.704 with k-space corrupted data and achieves 0.722 with additional data augmentation. |
| 2018 | Proposed spatio-temporal CNN, real data with k-space-corrupted data and additional translation augmentation proposed non-standard slice | F1-score | 0.722 | Motion Artifact Detection · split: test · subset=3,465 2D+time CMR sequences · augmentation=k-space-corrupted data and translation | Deep Learning using K-space Based Data Augmentation for Automated Cardiac MR Motion Artefact DetectionSource quoteL74: We used a 10-fold stratified cross validation strategy to test all algorithms, in which each image appears once in the test set over all folds. Due to the high class imbalance, over 0.9 accuracy is achieved by most of the techniques in Table \ref{table:1}. We do not rely only on accuracy in our results due to the bias introduced by the imbalanced classes. The interesting comparison for the methods lies in the recall numbers, which quantify the capability of the methods to identify images with artefacts. The results show that the CNN-based technique is capable of identifying the presence of motion artefacts with high recall compared to other techniques. Note in particular that introducing the data with k-space corruption increases the recall number from 0.466 to 0.642. Additional data augmentation improves the recall further to 0.652. All state-of-the-art classification methods reach high accuracy, but Adaboost is capable to reach comparable recall to CNNs without data augmentation. However, the precision of Adaboost is lower compared to the CNN results. Moreover, the F1-score illustrates the improvement of performance using CNN-based methods compared to state-of-the-art machine learning approaches. The F1-score reaches 0.704 with k-space corrupted data and achieves 0.722 with additional data augmentation. |
| 2017 | Proposed fully convolutional network (FCN; VGG-16-adapted) proposed non-standard slice | Average Dice metric | 0.94 | Image Segmentation · split: test · subset=short-axis CMR; LV cavity · backbone=VGG-16-adapted · test-subjects=600 | Human-level CMR image analysis with deep fully convolutional networksSource quoteL18: By combining FCN with a large-scale annotated dataset, the proposed automated method achieves a high performance in segmenting the LV and RV on short-axis CMR images and the left atrium (LA) and right atrium (RA) on long-axis CMR images. On a short-axis image test set of 600 subjects, it achieves an average Dice metric of 0.94 for the LV cavity, 0.88 for the LV myocardium and 0.90 for the RV cavity. The mean absolute difference between automated measurement and manual measurement was 6.1 mL for LVEDV, 5.3 mL for LVESV, 6.9 gram for LVM, 8.5 mL for RVEDV and 7.2 mL for RVESV. On long-axis image test sets, the average Dice metric was 0.93 for the LA cavity (2-chamber view), 0.95 for the LA cavity (4-chamber view) and 0.96 for the RA cavity (4-chamber view). The performance is comparable to human inter-observer variability. |
| 2017 | Proposed fully convolutional network (FCN; VGG-16-adapted) proposed non-standard slice | Average Dice metric | 0.88 | Image Segmentation · split: test · subset=short-axis CMR; LV myocardium · backbone=VGG-16-adapted · test-subjects=600 | Human-level CMR image analysis with deep fully convolutional networksSource quoteL18: By combining FCN with a large-scale annotated dataset, the proposed automated method achieves a high performance in segmenting the LV and RV on short-axis CMR images and the left atrium (LA) and right atrium (RA) on long-axis CMR images. On a short-axis image test set of 600 subjects, it achieves an average Dice metric of 0.94 for the LV cavity, 0.88 for the LV myocardium and 0.90 for the RV cavity. The mean absolute difference between automated measurement and manual measurement was 6.1 mL for LVEDV, 5.3 mL for LVESV, 6.9 gram for LVM, 8.5 mL for RVEDV and 7.2 mL for RVESV. On long-axis image test sets, the average Dice metric was 0.93 for the LA cavity (2-chamber view), 0.95 for the LA cavity (4-chamber view) and 0.96 for the RA cavity (4-chamber view). The performance is comparable to human inter-observer variability. |
| 2017 | Proposed fully convolutional network (FCN; VGG-16-adapted) proposed non-standard slice | Average Dice metric | 0.90 | Image Segmentation · split: test · subset=short-axis CMR; RV cavity · backbone=VGG-16-adapted · test-subjects=600 | Human-level CMR image analysis with deep fully convolutional networksSource quoteL18: By combining FCN with a large-scale annotated dataset, the proposed automated method achieves a high performance in segmenting the LV and RV on short-axis CMR images and the left atrium (LA) and right atrium (RA) on long-axis CMR images. On a short-axis image test set of 600 subjects, it achieves an average Dice metric of 0.94 for the LV cavity, 0.88 for the LV myocardium and 0.90 for the RV cavity. The mean absolute difference between automated measurement and manual measurement was 6.1 mL for LVEDV, 5.3 mL for LVESV, 6.9 gram for LVM, 8.5 mL for RVEDV and 7.2 mL for RVESV. On long-axis image test sets, the average Dice metric was 0.93 for the LA cavity (2-chamber view), 0.95 for the LA cavity (4-chamber view) and 0.96 for the RA cavity (4-chamber view). The performance is comparable to human inter-observer variability. |