UK Biobank
83 papers · 264 extracted observations · phenotype prediction · Markdown · CSV · JSON API
Also indexed as: uk-biobank
Tasks on UK BiobankAll tasks (83)Phenotype Prediction (7)Genome Wide Association Study (4)Image Generation (4)Bmi Prediction (3)Disease Classification (3)Brain Tissue Segmentation (2)Cardiovascular Risk Prediction (2)Disease Detection (2)
TaskPhenotype Prediction (34)Genome Wide Association Study (10)Image Generation (7)Disease Classification (7)Risk Prediction (7)Time to Event Prediction (6)Dementia Risk Prediction (6)
Metricauroc (27)auc (24)mae (22)accuracy (16)concordance index c index (6)average relative efficiency re (6)error rate (6)
Regimefine-tuned (10)5-fold-cross-validation (8)age-conditioned (6)gwas (6)transfer-learning (5)linear-probe (4)
Showing 7 of 7 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2024 | Net1D + Dist Loss (paper's “Ours”) proposed non-standard slice | MAE | 9.495 | Vascular Age Estimation · split: test · few-shot · subset=labels with occurrence probability below one-third of the maximum | Deep Imbalanced Regression to Estimate Vascular Age from PPG Data: a Novel Digital Biomarker for Cardiovascular HealthSource quoteL171: + Ours │ \textbf{\textcolor{red}{0.686}} │ \textbf{\textcolor{red}{9.495}} │ \textbf{\textcolor{red}{12.029}} │ \textbf{\textcolor{red}{0.158}} │ \textbf{\textcolor{red}{4.963}} │ 6.851 │ \textbf{\textcolor{red}{59.846}} │ \textbf{\textcolor{red}{75.815}} |
| 2024 | Plain Net1D baseline non-standard slice | MAE | 12.820 | Vascular Age Estimation · split: test · few-shot · subset=labels with occurrence probability below one-third of the maximum | Deep Imbalanced Regression to Estimate Vascular Age from PPG Data: a Novel Digital Biomarker for Cardiovascular HealthSource quoteL165: Plain │ 0.637 │ 12.820 │ 13.786 │ 0.015 │ 6.522 │ 7.524 │ 865.377 │ 930.543 |
| 2020 | Proposed deep generative model-based quality control proposed non-standard slice | Mean absolute error (MAE) | 0.07 | Segmentation Quality Estimation · split: test · n=500 · subset=attacked segmentations · perturbation=white noise at varying variance levels | Deep Generative Model-Based Quality Control for Cardiac MRI SegmentationSource quoteL99: Quality control performance is assessed in terms of Dice metric prediction accuracy. Pearson correlation coefficient r and mean absolute error (MAE) between predicted Dice and real Dice are calculated. Table 1 compares the quantitative performance of the methods and Fig.\ref{figure3} visualises the predictions. On UK Biobank dataset, the hand-crafted feature method performed the worst. The proposed method achieved a similar performance (r=0.96, MAE=0.07) as the CNN regression method (r=0.97, MAE=0.06). However, on ACDC dataset, the proposed method (r=0.97, MAE=0.03) outperformed the CNN regression method (r=0.97, MAE=0.17) with a smaller MAE. As shown in Fig. \ref{figure3}, on ACDC dataset, the prediction of the proposed method aligns well with the identity line, whereas the CNN regression method clearly deviates from the line, even though the r coefficient is still high. |
| 2020 | Best single-patch network proposed | MAE | 2.46 years | Brain Age Estimation · split: test · resolution=64x64 · input=3D T1-weighted MRI · backbone=3D ResNet · selection=best of 27 patch models · patch_size=64×64×64 voxels | Patch-Based Brain Age Estimation from MR ImagesSource quoteL44: Best single-patch network │ 2.46 │ 0.80 |
| 2020 | All-patch linear-regression ensemble proposed | MAE | 2.13 years | Brain Age Estimation · split: test · input=3D T1-weighted MRI · ensemble=all-patch linear regression · bias_correction=uncorrected | Patch-Based Brain Age Estimation from MR ImagesSource quoteL100: The use of linear regression works better. Specifically, we achieve a MAE of 2.13 years when all the single-patch models are used. Furthermore, when we use only the models of the patches with the most important information for the age of the brain, we achieve a MAE of 2.16 years. Regarding R^2 score, it is 0.85 in both cases. In this case, bias correction is applied as well and we achieve a MAE of 1.96 years, and an R^2 score of 0.87. The scatter plots of the real over predicted ages, before and after bias correction is applied, are shown in Figure \ref{fig4}. |
| 2020 | All-patch linear-regression ensemble proposed | MAE | 1.96 years | Brain Age Estimation · split: test · input=3D T1-weighted MRI · ensemble=all-patch linear regression · bias_correction=corrected | Patch-Based Brain Age Estimation from MR ImagesSource quoteL100: The use of linear regression works better. Specifically, we achieve a MAE of 2.13 years when all the single-patch models are used. Furthermore, when we use only the models of the patches with the most important information for the age of the brain, we achieve a MAE of 2.16 years. Regarding R^2 score, it is 0.85 in both cases. In this case, bias correction is applied as well and we achieve a MAE of 1.96 years, and an R^2 score of 0.87. The scatter plots of the real over predicted ages, before and after bias correction is applied, are shown in Figure \ref{fig4}. |
| 2020 | Baseline model (3D ResNet) baseline | MAE | 2.64 years | Brain Age Estimation · split: test · input=3D T1-weighted MRI · backbone=3D ResNet · bias_correction=uncorrected | Patch-Based Brain Age Estimation from MR ImagesSource quoteL42: Baseline model (uncorrected) │ 2.64 │ 0.77 |