UK Biobank

83 papers · 264 extracted observations · phenotype prediction · Markdown · CSV · JSON API

Also indexed as: uk-biobank

Showing 9 of 9 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2024Net1D + Dist Loss (paper's “Ours”) proposed non-standard sliceMAE9.495Vascular Age Estimation · split: test · few-shot · subset=labels with occurrence probability below one-third of the maximumDeep Imbalanced Regression to Estimate Vascular Age from PPG Data: a Novel Digital Biomarker for Cardiovascular Health
Source quote
L171: + Ours │ \textbf{\textcolor{red}{0.686}} │ \textbf{\textcolor{red}{9.495}} │ \textbf{\textcolor{red}{12.029}} │ \textbf{\textcolor{red}{0.158}} │ \textbf{\textcolor{red}{4.963}} │ 6.851 │ \textbf{\textcolor{red}{59.846}} │ \textbf{\textcolor{red}{75.815}}
2023Proposed method (adaptive graph learning) proposedMAE3.61Age Regression · runs=10Multimodal brain age estimation using interpretable adaptive population-graph learning
Source quote
L149: For the evaluation of the pipeline in the regression task, we use Mean Absolute Error (MAE), and the Pearson Correlation Coefficient (r score). A summary of the performance of the proposed and competing methods is available at Table \ref{tab1:regr}. Linear regression (MAE=3.82) outperforms GCNs trained on static graphs whether these are based on the node features (MAE=3.87) or leverage the phenotypes (MAE=3.98). The DGM outperforms the baselines (MAE=3.72). The proposed method outperforms all others (MAE=3.61).
20232D-Slice model with pretrained encoder proposedMAE2.715Brain Age Prediction · encoder=pretrainedTransferring Models Trained on Natural Images to 3D MRI via Position Encoded Slice Models
Source quote
L152: Our main goal with these experiments is to demonstrate improvement in performance due to natural image pretraining. Nevertheless, another interesting outcome is that 2D-Slice models with pretrained encoders are the best for both tasks, outperforming the 3D-CNN as well. For the AD task, we observe that 3D-CNN has a balanced accuracy of 88.40. In contrast, models with pretrained ResNet-18 encoder model have a balanced accuracy of 88.6 when using slices along the axial direction (both with and without position encodings). Similarly, the best MAE with the pretrained model for brain age prediction is 2.715 compared to 2.792 MAE with 3D-CNN. Finally, We also evaluated if increasing the size of the pretrained encoder may lead to more gain by employing ResNet-50 as the encoder for brain age prediction.
2020Proposed deep generative model-based quality control proposed non-standard sliceMean absolute error (MAE)0.07Segmentation Quality Estimation · split: test · n=500 · subset=attacked segmentations · perturbation=white noise at varying variance levelsDeep Generative Model-Based Quality Control for Cardiac MRI Segmentation
Source quote
L99: Quality control performance is assessed in terms of Dice metric prediction accuracy. Pearson correlation coefficient r and mean absolute error (MAE) between predicted Dice and real Dice are calculated. Table 1 compares the quantitative performance of the methods and Fig.\ref{figure3} visualises the predictions. On UK Biobank dataset, the hand-crafted feature method performed the worst. The proposed method achieved a similar performance (r=0.96, MAE=0.07) as the CNN regression method (r=0.97, MAE=0.06). However, on ACDC dataset, the proposed method (r=0.97, MAE=0.03) outperformed the CNN regression method (r=0.97, MAE=0.17) with a smaller MAE. As shown in Fig. \ref{figure3}, on ACDC dataset, the prediction of the proposed method aligns well with the identity line, whereas the CNN regression method clearly deviates from the line, even though the r coefficient is still high.
2020Best single-patch network proposedMAE2.46 yearsBrain Age Estimation · split: test · resolution=64x64 · input=3D T1-weighted MRI · backbone=3D ResNet · selection=best of 27 patch models · patch_size=64×64×64 voxelsPatch-Based Brain Age Estimation from MR Images
Source quote
L44: Best single-patch network │ 2.46 │ 0.80
2020All-patch linear-regression ensemble proposedMAE2.13 yearsBrain Age Estimation · split: test · input=3D T1-weighted MRI · ensemble=all-patch linear regression · bias_correction=uncorrectedPatch-Based Brain Age Estimation from MR Images
Source quote
L100: The use of linear regression works better. Specifically, we achieve a MAE of 2.13 years when all the single-patch models are used. Furthermore, when we use only the models of the patches with the most important information for the age of the brain, we achieve a MAE of 2.16 years. Regarding R^2 score, it is 0.85 in both cases. In this case, bias correction is applied as well and we achieve a MAE of 1.96 years, and an R^2 score of 0.87. The scatter plots of the real over predicted ages, before and after bias correction is applied, are shown in Figure \ref{fig4}.
2020All-patch linear-regression ensemble proposedMAE1.96 yearsBrain Age Estimation · split: test · input=3D T1-weighted MRI · ensemble=all-patch linear regression · bias_correction=correctedPatch-Based Brain Age Estimation from MR Images
Source quote
L100: The use of linear regression works better. Specifically, we achieve a MAE of 2.13 years when all the single-patch models are used. Furthermore, when we use only the models of the patches with the most important information for the age of the brain, we achieve a MAE of 2.16 years. Regarding R^2 score, it is 0.85 in both cases. In this case, bias correction is applied as well and we achieve a MAE of 1.96 years, and an R^2 score of 0.87. The scatter plots of the real over predicted ages, before and after bias correction is applied, are shown in Figure \ref{fig4}.
2019Reverse Classification Accuracy (RCA) proposedMAE of predicted DSC0.029Segmentation Quality Control · split: val · segmenter=random-forest · sample-size=400 · segmentation=whole-heartAutomated Quality Control in Image Segmentation: Application to the UK Biobank Cardiac MR Imaging Study
Source quote
L188: WH │ 0.988 │ 0.979 │ 0.000 │ \multirow{2}{*}{0.029} │ \multirow{2}{*}{4.445} │ \multirow{2}{*}{5.504} │ \multirow{2}{*}{15.11}
2019Reverse Classification Accuracy (RCA) proposed non-standard sliceMAE of predicted DSC0.035Segmentation Quality Control · trees=500 · depths=5, 40 · segmenter=random-forest · sample-size=4800 · segmentation=whole-heartAutomated Quality Control in Image Segmentation: Application to the UK Biobank Cardiac MR Imaging Study
Source quote
L222: WH │ 0.954 │ 0.966 │ 0.148 │ \multirow{2}{*}{0.035} │ \multirow{2}{*}{1.156} │ \multirow{2}{*}{2.762} │ \multirow{2}{*}{12.52}